• Title/Summary/Keyword: Pulse current

Search Result 1,866, Processing Time 0.039 seconds

The Change of Composition and the Throwing Power of Pb-Sn Alloy Electrodeposits in Pulse Plating (파형전류전해에 의한 Pb-Sn합금의 조성변화 및 균일전착력)

  • 예길촌;김용웅
    • Journal of the Korean institute of surface engineering
    • /
    • v.22 no.4
    • /
    • pp.197-206
    • /
    • 1989
  • The Composition and throwing power-of Pb-Sn alloy deposits are investigated in tems of the pulse parameters in pulse plating. Microhardness and intermal srress of alloy deposots are measured. The current efficiency of pulse plating is lower than that of D.C.plating while cathode overpotential and macro-throwing power noticebly increase with increasing peak current density. The Pb content of P.C. plated alloy deposits with increasing average current density, is relatively lower than of D.C. plated deposits at the same average current density. The internal stress of Pb-Sn alloy is not detected and the microhardness are 9.0kg/mm2 and 11kg/mm2 for D.C. plated P.C. plated deposits, respectively.

  • PDF

Optimization of the Large Scale Magnetic Pulse Compression System of 100 ns-order (100 ns급 대용량 자기펄스 압축시스템의 최적화)

  • 이용우;이영우
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2003.10a
    • /
    • pp.442-445
    • /
    • 2003
  • In this study, we developed the 40 J-class MPC(magnetic pulse compression) system for exciting excimer laser and investigated the optimal conditions of each stage of MPC circuit. This system consists of a DC power supply, a pulse transformer and four saturable inductors. The number of turns of saturable inductors at each stage of MPC circuit are 140, 25, 5, 1 and the optimal storage capacitance of each stage are 34 nF, 28.9 nF, 22.1 nF, respectively. In the improvement MPC system, we have obtained an output voltage of 43 kV, a current of 8.25 kA and a pulse duration of 360 ns. Also, the maximum pulse compression ratio of 77.7 and the current gain of 71.7 were obtained.

  • PDF

Influence on EDM Surface with the Copper and Graphite Electrode According to the Discharge Energy (방전에너지에 따라 동전극과 흑연전극이 방전가공면에 미치는 영향)

  • Choi, Jae-Yong;Jeon, Eon-Chan;Jeong, Jae-Hyun
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.14 no.5
    • /
    • pp.53-59
    • /
    • 1997
  • This study has been performed to inmvestigate MRR(metal removal rate), REW(relative electrode wear), surface roughness, heat transumutation layer and microhardness distribution in cross-section of the machined surface with various pulse-on duration and peak pulse current, using the copper and graphite electrode on the heat treated STD11 which is extensively used for metallic molding steel with the EDM. The results obtained are as follows; a) There exists critical pulse-on duration(If Ip equals 5A, .tau. on is 50 .mu. s) which shows the the maximum MRR in accordance with peak oulse current and the MRR decreases when the pulse-on duration exceeds the critical pulse-on during because of the abnormal electric discharge. b) Safe discharge is needed to make maximum of MRR and the metalic organization must be complicated for discharge induction. c) Graphite has much more benefits than copper electrode when rapid machining is done without electrode wear. d) The most external surface has the highest microhardness because of car- burizing from heat analysis of the dielectric fluid and the lower layar of the white covered layer has lower microhar dness than base matal because of softening.

  • PDF

The Controller Design of a 2.4MJ Pulse Power Supply for a Electro-Thermal-Chemical Gun (전열화학포용 2.4MJ 펄스 파워 전원의 제어기 설계)

  • Kim, Jong-Soo;Jin, Y.S.;Lee, H.S.;Rim, Geun-Hie;Kim, J.S.
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.55 no.12
    • /
    • pp.511-517
    • /
    • 2006
  • The key issues in high power, high energy applications such as electromagnetic launchers include safety, reliability, flexibility, efficiency, compactness, and cost. To explore some of the issues, a control scheme for a large current wave-forming was designed, built and experimentally verified using a 2.4MJ pulse power system (PPS). The PPS was made up of eight capacitors bank unit, each containing six capacitors connected in parallel. Therefore there were 48 capacitors in total, with ratings of 22kV and 50kJ each. Each unit is charged through a charging switch that is operated by air pressure. For discharging each unit has a triggered vacuum switch (TVS) with ratings of 200kA and 250kV. Hence, flexibility of a large current wave-forming can be obtained by controlling the charging voltage and the discharging times. The whole control system includes a personal computer(PC), RS232 and RS485 pseudo converter, electric/optical signal converters and eight 80C196KC micro-controller based capacitor-bank module(CBM) controllers. Hence, the PC based controller can set the capacitor charging voltages and the TVS trigger timings of each CBM controller for the current wave-forming. It also monitors and records the system status data. We illustrated that our control scheme was able to generate the large current pulse flexibly and safely by experiments. The our control scheme minimize the use of optical cables without reducing EMI noise immunity and reliability, this is resulting in cost reduction. Also, the reliability was increased by isolating ground doubly, it reduced drastically the interference of the large voltage pulse induced by the large current pulse. This paper contains the complete control scheme and details of each subsystem unit.

The Properties of Na-Ca Exchange Current in Single Atrial Cells of ,The Rabbit (토끼 단일 심방근 세포에서 Na-Ca 교환전류의 특성에 관한 연구)

  • Youm, Wook;Ho, Won-Kyung;Suh, Kyung-Phill
    • Journal of Chest Surgery
    • /
    • v.22 no.4
    • /
    • pp.548-561
    • /
    • 1989
  • In single atrial cells isolated from the rabbit the properties of inward current of Na-Ca exchange were investigated using the whole cell voltage clamp technique. The current was recorded during repolarization following brief 2 ms depolarizing pulse to +40 mV from a holding potential of * 70 mV. Followings are the results obtained: 1. When stimulated every 30 seconds, the inward currents were activated and reached peak values 6-12 ms after the beginning of depolarizing pulse. The mean current amplitude was 342 pA/cell. 2. The current decayed spontaneously from the peak activation and the time course of the relaxation showed two different phases fast and slow phase. The time constants were 10-18 ms and 60-140 ms, respectively. 3. The recovery of inward current was tested by paired pulse of various intervals. The peak current recovered exponentially with time constant of 140 ms and 1 p M isoprenaline accelerated the recovery process. 4. Relaxation time course was also affected by pulse interval and time constant of the fast phase was reduced almost linearly according to the decrease of pulse interval between 30 sec and 1 sec. 5. The peak activation was increased in magnitude by long prepulse stimulation, 5 p M Bay K, 1 p M isoprenaline or internal and external application of c-AMP. 6. The relaxation time constant of the fast phase was prolonged by 5 p M Bay K or c-AMP, and shortened by isoprenaline. However the time course of the slow relaxation phase was not so much changed. From the above results, it could be concluded that increase of the calcium current by Bay K or c-AMP results in the potentiation and prolongation of intracellular calcium transient, and the facilitation of Ca uptake by SR might be a mechanism of shortening the time constant of current relaxation by short interval stimulation or isoprenaline.

  • PDF

Study on the Optimization of Pulse GTAW Process for Diaphragm with Thin Thickness (극박 다이아프램의 펄스 GTAW 공정 최적화에 관한 연구)

  • Park, Hyoung-Jin;Hwang, In-Sung;Kang, Mun-Jin;Rhee, Se-Hun
    • Journal of Welding and Joining
    • /
    • v.26 no.1
    • /
    • pp.63-68
    • /
    • 2008
  • This paper has aimed to prevent excessive heat input by controlling arc distribution and heat input capacity with pulse GTAW in order to improve weld quality in 0.08mm pressure gauge diaphragm and flange welding parts. A design of experiment was designed using Box-Behnken method to optimize a welding process. The pulse GTAW parameters such as pulse current, base current, pulse duty, frequency and welding speed were set to input variables while hydraulic pressure that represents welding characteristics in diaphragm and flange joint were set to output variables. Based on the test result, a second regression equation was obtained between input and output variables and turned out significant. Besides, an influence of parameters has been confirmed through response surface analysis using the second-order regression equation and optimum welding condition was obtained through a grid-search method. The optimum welding condition was set to pulse current 84.4(A), base current 29.6(A), pulse duty 58.8(%), frequency 10(%), and welding speed 596(mm/min). Then, decent bead shape was acquired with no excessive heat input under the $2.3kgf/cm^2$ of hydrostatic pressure.

A Basic Study on X-ray Controlled Semiconductor Switch for Pulse Power (펄스파워용 X선제어 무도체스위치의 기본연구)

  • Ko, Kwang-Cheol
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.41 no.9
    • /
    • pp.1013-1020
    • /
    • 1992
  • The conductivity variation of a high resistivity bulk silicon semiconductor, whose electrodes were deposited with aluminum vapor, was studied experimentally by measuring the X-ray intensity and current flow, which was developed by X-ray radiation while applying a pulse voltage to the silicon, in a load resistor connected to the semiconductor. The current flow observed immediately as the X-ray radiated, and when the X-ray decreased. It was found from the observation of switching current for the X-ray intensity and the voltage applied in the semiconductor that the switching current of the semiconductor increased as the intensity of the X-ray and the applied voltage increased. In case of lower applied voltage, the switching current for higher applied voltage depended on the intensity of the X-ray radiated due to the saturation of electron and hole.

  • PDF

A Study on Welding Process Algorithm through Real-time Current Waveform Analysis (실시간 공정신호를 통한 용접공정 알고리즘에 관한 연구)

  • Yoon, Jin Young;Lee, Young Min;Shin, Soon Cheol;Choi, Hae Woon
    • Journal of Welding and Joining
    • /
    • v.33 no.4
    • /
    • pp.24-29
    • /
    • 2015
  • The current waveform was analysed to monitor the weld quality in real time process. The acquired current waveform was discretely analysed for the top and bottom limits of peaks as well as the pulse frequency measurement. Fast Fourier Transform was implemented in the program to monitor the pulse frequency in real time. The developed algorithm or program was tested for the validation purpose. The cross-section of weld profile was compared to the current waveform profile to correlate the monitored signal and the actual parts. Pulse frequency was also used as auxiliary tool for the quality monitoring. Based on the results, it was possible to evaluate the quality of welding by measure the current waveform profile and frequency measurement.