• 제목/요약/키워드: Pulse corona

검색결과 108건 처리시간 0.032초

기중방전의 방전원별 특성분석 및 패턴분류 (Properties and Classification of Patterns of Air Discharges)

  • 박영국;이광우;장동욱;강성화;정광호;김완수;이용희;임기조
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제49권1호
    • /
    • pp.19-23
    • /
    • 2000
  • Partial discharges(PD)in air insulated electric power apparatus often lead to deterioration of solid insulation by electron bombardments and electrochemical reaction. The PD caused to reduce the life time of power apparatus and to increase power losses. Thus understanding and classification of PD patterns in air are very important to discern sources of PD. In this paper, PD in air by using statistical methods was investigated. We classified air discharges, corona, surface discharges and cavity discharges by Kohonen network. For classification of PD patterns, we used statistical operators and parameters such as skewness$(S^+,\; S^-),\; kurtosis(K^+, K^-),\; mean phase(AP^+, AP^-)$, cross-correlation factor(CC) and asymmetry derived from the mean pulse-height phase distribution$(H_{avg}(\phi))$, the max pulse-height phase distribution $(H_{qmax}(\phi))$, the pulse count phase distribution $(H_n(\phi))$ and the pulse height vs. Repetition rate $(H_q(n))$.

  • PDF

피에조를 이용한 코로나 방전과 펄스교류 코로나 방전을 이용한 정전기 제거장치의 비교 연구 (A Comparative Study on the Electrostatic Eliminator of Piezo Type Ionizer and Pulse AC Corona Type Ionizer)

  • 권승열;이동훈;최재욱
    • 한국안전학회지
    • /
    • 제24권6호
    • /
    • pp.50-54
    • /
    • 2009
  • Ionizer is used for improving manufacturing process and reducing inferior goods in the clean room. As a general rule, neutralization of the electrostatic charge is most important to make TFT-LCD, PDP and OLED. Pulse AC-static eliminator with output voltage of about 10.5kV has been used these days as neutralization device. But this device has a problem with lower performance which was caused by particles-adhesion on the electrode when it has been used for a long time. So we studied to solve the problem with lower performance using high Frequency(72kHz) static eliminator which was produced by Piezo transformer device, and compared Pulse-AC type with Piezo-electronic device such as decay time and ion balance for 10 weeks periods. As a result of this study, we found that Piezo transformer device has been maintained normal condition for 10 weeks. Also, we made the rule by this study, normally Piezo transformer device has to clean the electrode during every 11th weeks.

기중방전의 특성분석과 Kohonen network에 의한 방전원의 패턴분류 (Properties and classification of air discharge by Kohonen network)

  • 강성화;박영국;이광우;김완수;이용희;임기조
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1999년도 춘계학술대회 논문집
    • /
    • pp.704-707
    • /
    • 1999
  • Partial discharge(PD) in air insulated electric power systems is responsible for considerable power lossesfrom high voltage transmission lines. PD in air often leads to deterioration of insulation by the combined action of the discharge ions bombarding the surface and the action of chemical compounds that are formed by the discharge and may give rise to interference in ommunication systems. PD can indicate incipient failure. Thus understanding and classification of PD in air is very important to discern source of PD. In this paper, we investigated PD in air by using statical method. We classified air discharge with corona, surface discharge and cavity discharge by source of discharge. we used the mean pulse-height phase distribution $H_{qmean}(\psi)$, the max pulse-height phase distribution $H_{qmax}(\psi)$ , the pulse count phase distribution $H_n(\psi)$ and the max pulse height vs. repetition rate $H_{q}(n)$ for analysis PD pattern. We used statistical operators, such as skewness(S+. S-1, kurtosis(K+, K-), mean phase(AP+. AP-), cross-correlation factor(CC) and asymmetry from the distribution.

  • PDF

PA Map(Pulse Analysis Map)을 이용한 새로운 부분방전 패턴인식에 관한 연구 (A Study on the New Partial Discharge Pattern Analysis System used by PA Map (Pulse Analysis Map))

  • 김지홍;김정태;김진기;구자윤
    • 전기학회논문지
    • /
    • 제56권6호
    • /
    • pp.1092-1098
    • /
    • 2007
  • Since one decade, the detection of HFPD (High frequency Partial Discharge) has been proposed as one of the effective method for the diagnosis of the power component under service in power grids. As a tool for HFPD detection, Metal Foil sensor based on the embedded technology has been commercialized for mainly power cable due to its advantages. Recently, for the on-site noise discrimination, several PA (Pulse analysis) methods have been reported and the related software, such as Neural Network and Fuzzy, have been proposed to separate the PD (Partial Discharge) signals from the noises since their wave shapes are completely different from each other. On the other hand, the relevant fundamental investigation has not yet clearly made while it is reported that the effectiveness of the current methods based on PA is dependant on the types of sensors. Moreover, regarding the identification of the vital defects introducible into the Power Cable, the direct identification of the nature of defects from the PD signals through Metal Foil coupler has not yet been realized. As a trial for solving above shortcomings, different types of software have been proposed and employed without any convincing probability of identification. In this regards, our novel algorithm 'PA Map' based on the pulse analysis is suggested to identify directly the defects inside the power cable from the HFPD signals which is output of the HFCT and metal foil sensors. This method enables to discriminate the noise and then to make the data analysis related to the PD signals. For the purpose, the HFPD detection and PA (Pulse Analysis) system have been developed and then the effect of noise discrimination has been investigated by use of the artificial defects using real scale mockup. Throughout these works, our system is proved to be capable of separating the small void discharges among the very large noises such as big air corona and ground floating discharges at the on-site as well as of identifying the concerned defects.

공기/석영관(空氣/石英管) 복합유전체(複合誘電體)장벽층(障壁層)의 고주파(高周波) 펄스 방전(放電) 특성(特性) (Air/Quartz Dielectric Double Barrier Pulse Discharge)

  • 이응관;우정욱;정석환;이동훈;문재덕
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 C
    • /
    • pp.1556-1558
    • /
    • 1994
  • An air/quartz dielectric double barrier pulse discharge has been investigated to develop a novel si lent type ozone generator. It is found that there are very active pulsed coronas occurred in the airgap which are very useful for ozone generation. And, the corona onset voltage of the airgap of the air/quartz double barrier was enfluenced greatly by the airgap of the air/quartz dielectric double barrier, and depended greatly upon the airgap ranged of $0.0{\sim}3.0mm$ and by the quartz tube thickness ranged of $1.75{\sim}2.25mm$.

  • PDF

고전압(高電壓) Nozzle 에서 유출(流出)하는 기체(氣體)의 방전특성(放電特性)에 관한 연구(硏究) (A Study on Discharge Characteristics in Flowing Gas at High Voltage Nozzle)

  • 송현직;김상구;전영주;이광식;이동인
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 하계학술대회 논문집 B
    • /
    • pp.563-565
    • /
    • 1993
  • This paper describes ozone concentration and discharge characteristics in flowing $O_2$ with variation of Re at high voltage nozzle(HVN). HVN type ozonizer is equipped with ten nozzle. The important conclusions obtained from this paper are as follows. For constant pulse width(Pw) and pulse frequency(Pf) the more Re increases, the higher corona onset voltage(Vc) rise. Vc is inversely proportional to Pw and Pf. Ozone concentration($O_{3con}$) increases with less Re for constant Pw and Pf. $O_{3con}$ increases with less Pw. $O_{3con}$ is proportional to Pf.

  • PDF

Non-thermal Plasma Process for simultaneous removal of SO2/NOx from a Sintering Plant of Steel Works

  • 남창모;목영선;권기홍;서유덕;조병락
    • 한국산업융합학회 논문집
    • /
    • 제6권1호
    • /
    • pp.81-86
    • /
    • 2003
  • For the simultaneous removal of $SO_2$/NOx from an iron-ore sintering plant, industrial plasma experiments have been conducted with a flue gas flow rate of $5,000Nm^3/hr$. The maximum 40kW power using the magnetic pulse compression (MPC) system generates a peak value of 100-150kV pulse voltage with its risetime of 200nsec and full width at half maximum (FWHM) of 500nsec, and with a frequency <300Hz. The plasma reactor module adopts a wire-plate structure with a gap of 200-400mm ID between plates. Initial concentrations of $SO_2$ and NOx were around 100-150ppm, respectively in the presence of 15% $O_2$ and <10% $H_2O$. Various reaction parameters such as specific energy ($Whr/Nm^3$), $NH_3$ injection with corona discharge, flow rate and injection of hydrocarbons were investigated for $SO_2$/NOx removal characteristics. About 90/65% of $SO_2$/NOx were simultaneously removed with a specific energy of $3.0Whr/Nm^3$ when both $NH_3$ and hydrocarbons were injected. Practical implications that the pilot-scale plasma results provide are further discussed.

  • PDF

저온 플라즈마 공정에 의한 효율적인 탈황 및 탈질 (Efficient Desulfurization and Denitrification by Low Temperature Plasma Process)

  • 김성민;김동주;김교선
    • Korean Chemical Engineering Research
    • /
    • 제43권1호
    • /
    • pp.129-135
    • /
    • 2005
  • 본 연구에서는 펄스 코로나 방전 공정에 의해 $SO_2$$SO_2/NO$의 제거효율을 분석하였으며, 여러 공정변수가 제거효율에 끼치는 영향을 체계적으로 조사하였다. 공정변수로서 인가전압, 펄스 주파수, 체류시간, 반응물의 초기 농도(NO, $SO_2$, $NH_3$, $H_2O$, and $O_2$)의 영향을 분석하였다. 인가되는 전압, 펄스 주파수 또는 체류시간이 증가함에 따라 또는 $O_2$$H_2O$가 첨가됨에 따라 $SO_2$의 제거효율과 $SO_2/NO$의 동시 제거효율은 증가하였다. 또한, $NH_3$의 초기 농도가 증가할수록 $SO_2/NO$의 제거효율은 증가하였다. 이 실험적인 결과들은 $NO_x$$SO_x$를 제거하기 위한 펄스 코로나 방전 공정 장치 설계의 기초 자료로 사용될 수 있다.

유전체구 충진형 전극계의 코로나방전과 강전해수 발생특성 (Corona Discharge and Strong Electrolyzed Water Generation Characteristics of the Electrode System Bedded by Dielectric Pellets)

  • 김진규
    • 조명전기설비학회논문지
    • /
    • 제16권4호
    • /
    • pp.46-54
    • /
    • 2002
  • 본 논문은 전해수 발생장치내에 이온분리집속 격막을 설치하여 비유전율이 틀리는 유전체구를 충진한 구조로 함으로써 고효율의 강전해수 발생장치를 제안하였다. 염화나트륨이 용해된 수도수와 일반수도수를 원료수로서 본 강전해수 발생장치에 인입하였을 때 충진된 유전체구의 비유전율 변화가 수중 이온분리집속성능에 미치는 영향을 연구 검토하였다. 실험결과로서 본 강전해수 발생장치에 원료수로서 수도수의 유속을 0.5[LPM]으로 인입시키고 구형파 펄스전류를 1.0[A]로 인가하였을 때 pH 3.1과 10.6의 전해수를 얻을 수 있었다. 그리고 염화나트륨이 0.1[wt%]용해된 수도수의 경우 pH 2.8과 11.7의 전해수를 얻었다. 또한 비유전율이 가장 높은 BaTiO$_3$과 같은 유전체구를 전해수 발생장치에 충진한 경우 각각 PH 2.7, 11.7과 pH 2.4, 12.0의 전해수를 얻을 수 있었다.