• Title/Summary/Keyword: Pulse characterization

Search Result 147, Processing Time 0.028 seconds

A Study on Arterial Characterization using Finger-Toe Index (FTI) (지첨-족지 지수에 의한 동맥 혈관 특성화 연구)

  • Byeon, M.K.;Han, S.W.;Huh, W.
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.6
    • /
    • pp.777-785
    • /
    • 2007
  • In this paper, Finger-Toe Index (FTI) is proposed as an analytic parameter for the characterization of arterial vessel. Different from the currently being employed pulse wave velocity (PWV) information of the volume pulse wave measured from 4 arterial channels, the proposed FTI uses the ratio of the shorter of the two up-stroke time of PPG from fingers ($UT_{finger}$) and that of PPG (Photoplethysmography) from toes ($UT_{toe}$). To verify the usefulness of the proposed method, Finger-Toe Indexes were derived from the volume pulse waves acquired from 50 people under examination aged from 12 to 81 years old, and they were then compared with blood pressure ankle-brachial index (ABI). It was successfully demonstrated that the arterial stiffness can be estimated with respect to age and FTI is more strongly correlated with the pulse transit time than ABI. From the regression analysis, we also found that FTI has significant correlation PWV for a quantitative index of arterial stiffness and provides more accurate information than ABI for the characterization of arterial vessel.

Temporal characterization of femtosecond laser pulses using spectral phase interferometry for direct electric-field reconstuction (주파수 위상 간섭계를 이용한 펨토초 레이저 펄스의 시간적 특성연구)

  • 강용훈;홍경한;남창희
    • Korean Journal of Optics and Photonics
    • /
    • v.12 no.3
    • /
    • pp.219-224
    • /
    • 2001
  • Spectral phase interferometry for direct electric-field reconstruction (SPIDER) was fabricated and used to characterize pulses from a Ti:sapphire oscillator. In the SPIDER apparatus, two replicas of the input pulse were generated with a time delay of 200 fs and were upconverted by use of sum-frequency generation with a strongly chirped pulse using a 8-cm-long SFIO glass block at a 30-11m-thick type II BBO (p-BaBz04) crystal. The resulting interferogram was recorded with a UV-enhanced CCD array in the spectrometer. The spectral phase was retrieved by SPIDER algorithm in combination with independently measured pulse spectrum and the corresponding temporal intensity profile was reconstructed with a duration of 19 fs. As an independent cross-check of the accuracy of the method, we compared the interferometric autocorrelation (lAC) signal calculated from the SPIDER data with a separately measured lAC. The conventional, but unjustified, method of fitting a sechz pulse to the autocorrelation deceivingly yielded a pulse duration of 15 fs. This systematic underestimation of the pulse duration affirms the need for a complete characterization method. From the consideration in this paper, we concluded that the SPIDER could provide an accurate characterization of femtosecond pulses. ulses.

  • PDF

Principles and Comparative Studies of Various Power Measurement Methods for Lithium Secondary Batteries (리튬이차전지 출력측정법의 원리 및 측정법간 비교 연구)

  • Lee, Hye-Won;Lee, Yong-Min
    • Journal of the Korean Electrochemical Society
    • /
    • v.15 no.3
    • /
    • pp.115-123
    • /
    • 2012
  • As the market of lithium secondary batteries moves from mobile IT devices to large-format electric vehicles or energy storage systems, the strengthened battery specifications such as long-term reliability longer than 10 years, pack-level safety and tough competitive price have been required. Moreover, even though high power properties should also be achieved for hybrid electric vehicles, it is not easy to measure accurate power values at various conditions. Because it is difficult to choose a proper measurement method and its experimental condition is more complex comparing to capacity measurement. In addition, the power values are very sensitive to power duration time, state-of-charge (SOC) of cells, cut-off voltages, and temperatures, whereas capacity values are not. In this paper, we introduce three kinds of power measurement methods, hybrid pulse power characterization (HPPC) suggested by US FreedomCar, so-called J-pulse by Japan electric vehicle association standards (JEVS) and constant power measurement, respectively. Moreover, with pouch-type unit cells for HEV, experimental power data are discussed in order to compare each power measurement.

Effect of aging toner type particles using pulse waveform (Pulse waveform을 이용한 Toner type particles의 Aging 효과)

  • Oh, Yoo-Mi;Kim, Kyung-Soo;Kim, Sung-Woon;Youn, Hae-Sang;Park, Sun-Woo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.142-142
    • /
    • 2010
  • This research proposed an advanced Electronic bead (EB) using MMA (Methy methacrylate) and CCA (Charge Control Agent). In the first, this paper presents about measurement method and characterization analysis of EB and nano-silica with pulse waveform in aging. Furthermore; this work presents the positive and negative EB fabrication procedure. As the experimental results, the proposed EB with square waveform is very attractive to Electronic paper driving characterization.

  • PDF

A Study on Arterial Characterization by using Up-stroke Time of Photoplethysmogram (용적맥파 상승시간에 의한 혈관 특성화 연구)

  • Byeon, M.K.;Han, S.W.;Huh, W.
    • Journal of IKEEE
    • /
    • v.11 no.3
    • /
    • pp.108-116
    • /
    • 2007
  • This paper proposed an analyzable parameter and its analytic method to provide more accurate information than currently employed 4 channels system which uses pulse wave velocity (PWV) information of the volume pulse wave measured from 4 arterial channels for the characterization of arterial vessel. In order to verify the volume pulse waves on 4 sites were simultaneously acquired subjects aged from 12 to 81 years old. and the proposed parameters were extracted from time (UT) was then compared with blood pressure. Then, the regression analyses were done relationships among the proposed parameter and others, such as aging, pulse transit time pressure (BP). The followings are the results of linear regression analysis of the proposed parameter for total 50 normal subjects. We selected any two subjects (58 years and 27 years) and measured PPG (photoplethysmogram) and BP of before and after exercise. The coefficient of correlations between BP and UT observed was -0.928 for 50 years subject, and -0.922 for 20 years subject. For total 50 normal subjects, in case of correlation between the pulse transit time and BP, the result showed -0.170 on left side and -0.233 on right side, and the coefficient value of correlation between the pulse transit time and UT was -0.607 on left side and -0.510 on right side. UI is strongly correlated with the pulse transit time than BP. Hence, we believe that the proposed parameter is related with the index of arterial stiffness.

  • PDF

Ultrashort Pulsed Laser Machining for Biomolecule Trapping

  • Choi, Hae-Woon;Farson, Dave F.;Lee, L.James;Lee, Ho
    • Journal of the Optical Society of Korea
    • /
    • v.13 no.3
    • /
    • pp.335-340
    • /
    • 2009
  • Ultrashort pulse laser drilling of polycarbonate track-etched membrane (pTEM) material was used to fabricate a mouse embryo cell trapping device. Holes with a diameter of $2{\mu}m$ to $5{\mu}m$ were fabricated on a $10{\mu}m$ thick membrane using a femtosecond laser with a 150 fs pulse width and 775 nm wavelength and multiple-pulse irradiation. In cell trapping tests, the overall cell occupancy of the machined holes in the fabricated pTEM was found to be more than 80%. The results of a single pulse and multiple pulse irradiation were compared in terms of the surface quality. It was generally found that a single pulse with high energy was less desirable than irradiation with multiple pulses of lower energy.

Characterization of sounds produced by 3 sciaenid species (민어과 어류의 명음에 관한 음향학적 특성)

  • Lee, Kyoung-Hoon;Yang, Yong-Soo;Kim, Jin-Ku;An, Heui-Chun;Shin, Jong-Keun
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.43 no.3
    • /
    • pp.206-211
    • /
    • 2007
  • The sciaenid species, which has swimbladder, generates sounds by vibrating in its length wards when spawning or getting stimulus from something else. This research analyzed on sound frequency characteristics relatives to their swimbladder length of three sciaenid species, yellow croaker(Larimichthys polyactis), brown croaker(Miichthys miiuy), and white flower croaker(Nibea albiflora). As results, the dominant frequency for yellow croaker ranged over 38.08 to 141.60Hz in wide frequency band, and the averaged pulse duration expressed in $280.3{\pm}156.0ms$. For brown croaker, the dominant frequency ranged in 49.80 to 59.57Hz, and the averaged pulse duration was $129.1{\pm}36.9ms$. Moreover, the dominant frequency of white flower croaker ranged in 73.24 to 86.91Hz, and the averaged pulse duration was $88.0{\pm}15.9ms$, it has shorter pulse duration than any two species. Therefore, the dominant frequency relatives to swimbladder length of sciaenidae showed that it had widely resonant characteristics and long pulse duration as in shorter swimbladder length. Additionally, for white flower croaker, we could confirm their behavior and sounds in response to production of recorded sounds using underwater speaker.

Pulse electrodeposition and characterization of Ni-$TiO_2$ nano composite coatings

  • Cho, Sung-Hun;Gyawali, Gobinda;Woo, Dong-Jin;Lee, Soo-Wohn
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2011.05a
    • /
    • pp.153-153
    • /
    • 2011
  • Ni $TiO_2$ nano composite coatings were fabricated by using pulse current electrodeposition technique at 100 Hz pulse frequency with a constant 50% pulse duty cycles and reference was taken with respect to the direct current electrodeposition. The properties of the composite coatings were investigated by using SEM, XRD, Wear test and Vicker's microhardness test. XRD patterns of pulse deposited composite coatings were found to be changed from preferred (100) orientation to the random mixed orientations. The results demonstrated that the Vickers microhardness of composite coatings under pulse condition was significantly improved than that of pure nickel coating as well as direct current electrodeposited Ni-$TiO_2$ composite coatings. Wear tracks have shown the less plastic deformation at pulse condition with reduced coefficient of friction. Nickel matrix grain size was also found to be lower in pulse plated composite coatings as compared to direct current electrodeposited composite coatings.

  • PDF

Effect of Taking Meal on Pulse Diagnosis in Healthy Subjects (식사가 정상인의 맥에 미치는 영향 분석)

  • Lee, Yu-Jung;Lee, Jeon;Lee, Hae-Jung;Choi, Eun-Ji;Kim, Jong-Yeol
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.21 no.6
    • /
    • pp.1670-1675
    • /
    • 2007
  • The pulse diagnosis studies reported to date has mainly been performed to clinically reveal the pulse wave characteristics according to the specific diseases, whereas no attempts have been made to study the effects on the pulse wave characteristics of the daily activities such as taking meals, exercise, and sleep, etc. This work reports the effect of feeding stimulus on the healthy subjects on the pulse wave pattern which has quantitatively been analyzed using the objective model for the pulse diagnosis in oriental medicine. The pulse waves right before/after the meal and 30 minutes after the meal were measured using the pulse analyzing equipment (3D-Mac, Daeyo Medi, Korea) and at the same time oriental medicine doctors' diagnoses were given. The pulse parameters obtained from the equipment and clinical records on the subjects were statistically processed and the variables showing statistically significant differences were analyzed. The results indicate that the pulse pressure, the pulse rate, and the respiratory rate increase while the blood pressure decreases after the meal. For the floating/sinking and the deficient/excess coefficients characterizing the pulse states described in the oriental medicine, the floating/sinking coefficients were observed to decrease whereas the deficiency/excess coefficients increase after the meal. The results indicates that besides the standard bio-indicators like blood pressure and respiratory rate, etc., the pulse wave characterization in terms of the pulse classifications in the oriental medicine using the floating/sinking, deficient/excess pulse states provide an important piece of biomedical information.

Characterization of UV-damaged repair genes in cells

  • Choi, In-Soon
    • Journal of Life Science
    • /
    • v.10 no.2
    • /
    • pp.50-54
    • /
    • 2000
  • The RAD4 gene of Saccharomyces cerevisiae is essential for the incision step of UV-induced excision repair. A yeast RAD4 gene has been previously isolated by functional complementation. In order to identify the RAD4 homologous gene from fungus Coprinus cinereus, we have constructed cosmid libraries from electrophoretically separated chromosomes of the C. cinereus. The 13 C. cinereus chromosomes were resolved by pulse-field gel electrophoresis, hybridized with S. cerevisiae RAD4 DNA, and then isolated homologous C. cinereus chromosome. Here, we report the cloning and characterization of fungus C. cinereus homolog of yeast RAD4 gene. Southern blot analysis confirmed that C. cinereus contains the sequence homologous DNA to RAD4 gene and this gene exists as a single copy in C. cinereus genome. When total RNA isolated from C. cinereus cells was hybridized with the 3.4 kb BglII DNA fragment of the S. cerevisiae RAD4 gene, a 2.5 kb of transcript was detected. The isolated gene encodes a protein of 810 amino acids.

  • PDF