• 제목/요약/키워드: Pulse analyzer

검색결과 153건 처리시간 0.03초

적혈구 용적이 요골 동맥의 맥파에 미치는 영향 (Effect of Hematocrit Level on the Radial Pulse Wave)

  • 유현희;전영주;김재욱;이혜정;우영재;이유정;김종열
    • 동의생리병리학회지
    • /
    • 제23권5호
    • /
    • pp.1035-1040
    • /
    • 2009
  • In this work, we investigate the effect of blood hematocrit level on the radial pulse wave to study the clinical application of the pulse analyzer. For this purpose, we measured the radial pulse wave at the left Gwan for 15 males with abnormal high hematocrit level and 47 males with normal hematocrit level at the age of thirties and forties. Various variables of the radial pulse wave between two groups were analyzed by Student's T test. We found significant differences in several characteristic variables in the amplitude, time-span and the integrated area of the amplitude and time of the pulse wave. The systolic peak in the amplitude of the radial pulse wave was higher in abnormal high hematocrit group. In contrast, the third peak from the second incisure was higher and longer in normal hematocrit group. Our study suggests that the radial pulse wave can be useful in distinguishing the patient group with high hematocrit level and thus with high blood viscosity. Our finding may motivate research activities towards diverse clinical applications of the pulse wave.

피부전기저항측정기(ABR-2000)의 맥진기(3D-MAC) 및 한방진단시스템(DSOM)과의 상관성 연구 (Study for Correlation of 3D-MAC and DSOM with ABR-2000)

  • 송정오;김민애;이인선
    • 대한한방부인과학회지
    • /
    • 제31권1호
    • /
    • pp.57-83
    • /
    • 2018
  • Purpose: This research has been carried out to find out correlation between test results of ABR-2000 and other diagnostic equipments to enhance significance of accurate diagnosis and clinical usage of ABR-2000. Methods: Duration of the 31 months from December 2012 to June 2015, records of 564 outpatients at gynecology department have been selected. The 564 patients were tested, using all 3 different test equipments of ABR-2000, DSOM, and 3D Blood Pressure Pulse Analyzer (3D-MAC) without test errors or mis-recordings. Correlation between 3D Blood pressure Pulse Analyzer, DSOM and ABR-2000 were analyzed by frequency & ratio factor of statistic data records of patients groups devided by 8 different disease symptom and by comparison of the groups in the form of Regulation and Graph presented on ABR-2000 equipment. Results: 1. The indicator L in all 1, 2, and 3 quadrant in the graph means the activity and reactivity of the upper body biodynamics detection rate is low and which result is very common symptom among gynecological patients. 2. The portion of patients with hypermenorrhea, endometritis, and menstrual pain symptom among the indicator L group in the reactivity 1-3 quadrantin is significantly high. 3. When 3D Mac analyzer indicates H, diastole decreases while systole increases and tachycardia increases then the blood circulation is expected to increase. In case of indication L, diastole increases and systole decreases then, the blood circulation is expected to decrease.

설문지와 의료기기 자료 분석을 통한 사상체질별 피로 특성 연구 (Characteristics of Fatigue in Sasang Constitution by Analyzing Questionnaire and Medical Devices Data)

  • 김구;하예진;박수정;최나래;이영섭;주종천
    • 사상체질의학회지
    • /
    • 제25권4호
    • /
    • pp.306-319
    • /
    • 2013
  • Objectives The purpose of this study was to find correlations between gastrointestinal disorders, pain, sleep disorder, fatigue, and to figure out characteristics of fatigue in Sasang Constitution using medical devices data. Methods Sixty three subjects were divided into fatigue group and non-fatigue group, both groups had to undergo blood tests, questionnaire, Sasang constitutional analysis tool (SCAT), pulse wave analyzer examination, heart rate variability examination, nail fold capillary microscopic examination. Results 1) The results of questionnaire about fatigue, gastrointestinal disorder, pain, sleep disorder, quality of life had significant differences between fatigue and non-fatigue groups. 2) Soeumin had more serious gastrointestinal problem and Soyangin had more serious sleep disorder in fatigue groups than non-fatigue groups. 3) According to blood test results, there was no difference between fatigue and non-fatigue groups. 4) Elastic parameter of pulse wave analyzer and nail fold capillary microscopic examination showed significant differences between fatigue and non-fatigue groups in Soyangin. Conclusions We reach the conclusion that fatigue is usually accompanied by gastrointestinal disorder, pain, sleep disorder, deterioration in the quality of life. In Soeumin, treating gastrointestinal disorders can be helpful for treatment of fatigue. In Soyangin, improving sleep disorder may be more effective way to treat fatigue.

뇌경새(腦梗塞) 환자(患者)와 건강인(健康人)의 맥상(脈象)과 사상체질(四象體質)에 관(關)한 연구(硏究) (Comparative Study on the Pulse Wave Variables and Sasang Constitution in Cerebral Infarction Patients and Healthy Subjects)

  • 고기덕;김경요;김종열;이시우;주종천
    • 대한약침학회지
    • /
    • 제10권2호통권23호
    • /
    • pp.119-132
    • /
    • 2007
  • This study was performed to determine whether a pulse analyzer was useful 1) to characterize the variables of pulse wave of cerebral infarction patieno (CI), compared with those of healthy subjects, as well as 2) to determine Sasang Constitution in CI and healthy subjects. 1. Calibrated in Gwan, the amount of energy(Energy), height of main peak(H1), height of aorticvalley(H2), height of aortic peak(H3), total area of pulse wave(At), and area of main peak width(Aw) of the CI group were higher than those of the healthy group. 2. Calibrated in Cheek, Energy, H1, H2, H3, height of valve valley(H4), At, Aw, and main peak angle(MPA) of the CI group were higher than those of the healthy group. 3. Among the healthy (subjects) group, Taeumin showed the highest contact pressure(CP) and height of valve peak(H5) calibrated in Chon. The main peak width divided by whole time of pulse wave(MPW/T) calibrated in Gwan and Cheok, was highest in Soyangin and was lowest in Taeumin. The H3 divided by H1(H3/H1) and the time to valve valley minus the time to main peak and divided by T[(T4-T1)/T] calibrated in Cheek were highest in Soyangin. The time to main peak(T1) was longest in Soumin. 4. Among the CI group, At calibrated in Chon was widest in Taeumin and was narrowest in Soumin The time to aortic peak(T3) calibrated in Cheek was longest in Soumin and was shortest in Soyangin. The time to valve peak(T5) was shortest in Soyangin. 5. There were main effects of cerebral infarction in the area of systolic period(As) and area of diastolic period(Ad) calibrated in Chon, Energy calibrated in Cwan, and Energy, H1, H2, H3, (H4+H5)/Hl, and MPA calibrated in Cheek. 6. There were main effects of Sasang Constitution in (T4-T1)/T, area of systolic period(As), and Ad calibrated in Chon. 7. The interactions between the cerebral infarction and Sasang Constitution were observed in H5/H1 , T, At, As, Ad, and MPA calibrated in Chon, H4, T4, (T4-T1)/T, As, and Ad calibrated in Cwan, and 74,75, and MPW calibrated in Cheok. Therefore, we concluded that pulse analyzer was useful to determine the risk degree of cerebral infarction and Sasang Constitution.

PZT-고분자 3-3형 복합압전체 소자로 제작된 초음파 트랜스듀서의 펄스에코 응답특성 (Pulse-echo response of ultrasonic transducer fabricated with PZT-polymer 3-3 type composite)

  • 박정학;최헌일;손무현;사공건
    • E2M - 전기 전자와 첨단 소재
    • /
    • 제9권10호
    • /
    • pp.1053-1059
    • /
    • 1996
  • The pulse-echo response of the piezoceramics PZT-polymer 3-3 type composite transducers with various PVA additions were investigated. The PZT powder was prepared by the molten salt synthesis method. The porous PZT specimens will be used as a filler to make 3-3 type comosite were prepared from a mixture of PZT and polyvinylalcohol(PVA) sphere by utilizing BURPS(Bumout Plastic Sphere) technique. It was shown that the transmitting and receiving sensitivity of 3-3 type piezoelectric composite transducers could be improved than that of solid PZT transducers. The reason is that 3-3 type piezoelectric composite have low dielectric constant, density and acoustic impedance. The distance between transducer and reflector was in good agreement with the distance calculated from the longitudinal velocity of the specimens and receiving time observed pulse-echo responses on the ultrasonic transducer analyzer.

  • PDF

이동 형 산업용 단층측정 장치를 위한 감마선 검출시스템 개발 (Development of Measurement System for Industrial Transportable Gamma Ray CT)

  • 김종범;정성희;문진호
    • 방사선산업학회지
    • /
    • 제6권3호
    • /
    • pp.231-237
    • /
    • 2012
  • This paper introduces a gamma-ray measurement system for a transportable tomography which is applicable for an industrial process diagnosis. The gamma-ray measurement system consists of pulse mode operating 72 channel CsI detectors, main AMP-pulse shaper, single channel analyzer, counter and control PC. The CsI crystal is coupled with a PIN diode which is connected to an amplifier and pulse shaper. For a compact design, the amplifier and pulse shaping circuit are included in a single package. 36 sets of CsI detectors are connected to a multi-channel counter through single channel analyzers. A computer controls and collects data from two multi-channel counters. This configuration results in 72 channel counting system in total. The CT rotator and radiation measurement system are controlled by a PC with LabVIEW program. Tomographic data were measured for a phantom by the measurement system and transportable gamma-ray CT. From the experimental data image reconstructions were performed by ML-EM algorithm. The result showed that the CsI detector system can be a suitable component for transportable gamma-ray CT system.

UWB 안테나 링크 특성화를 위한 네트워크 분석기를 이용한 시간영역 측정 및 분석기술 연구 (Study of Time Domain Measurement and Analysis Technique Using Network Analyzer for UWB Antenna link Characterization)

  • 고영목;김민종;김근용;나극환
    • 전자공학회논문지
    • /
    • 제49권10호
    • /
    • pp.69-80
    • /
    • 2012
  • 본 논문에서는 임펄스 신호를 방사하는 UWB 안테나의 링크 특성을 분석하기 위해 주파수영역에서 안테나 특성을 측정하기 위해 사용하는 네트워크 분석기를 이용한 시간영역 측정 및 분석기술에 대해 연구하였다. 이를 위해 네트워크 분석기에서 획득한 데이터를 줌-인(Zoom-In)이 가능한 시간영역으로 변환하기 위한 CZT(Chirp z-Transform) 알고리즘을 개발하였다. 개발된 CZT 알고리즘을 이용하여 주파수영역에서 각 안테나 링크에 대한 파형분석을 통해 표준이산푸리에 변환(Discrete Fourier Transform)보다 고속으로 변환이 가능하고 임의의 원하는 구간을 줌-인 함으로서 효율적으로 파형분석이 가능함을 증명하였다.

500명 여성을 대상으로 한 팔강변증에 따른 맥파 특성 연구 (A Study on the Characteristics of Pulse Waves according to Eight Principle Pattern Identification in 500 Women)

  • 이인선;전수형;강창완;김종원
    • 동의생리병리학회지
    • /
    • 제35권6호
    • /
    • pp.274-279
    • /
    • 2021
  • This study was conducted to find objective diagnostic indicators for the Eight Principle Pattern Identification using a pulse wave analyzer. Typology Complexion Pulse and Symptom data from 500 women over the age of 18 were used. Five experts made a diagnosis of Eight Principle Pattern Identification and divided the subjects into 'Yin-Yang', 'Exterior-Interior', 'Cold-Heat', 'Deficiency-Excess' groups. Their pulse waves were measured in the left and right radial arteries, and it was investigated whether there was a significant difference between groups in the pulse wave parameter values. 'Yin' group showed a significantly lower value in the left radial artery for Ener, Emin, EIX, T4T, T4TT parameters and in the Right for T2, T2T, T5. The Vmag, As and Ad parameters were significantly different between the 'Exterior' and 'Interior' groups. 'Heat' group showed a significantly higher value in the right radial artery for RAI/t parameter. 'Deficiency' group showed a significantly higher value in the right radial artery for W, Angl parameters. Through this study, significant pulse wave parameters were found, and they can be used as objective diagnostic indicators for Eight Principle Pattern Identification.

정지중 및 운전중 고압전동기 고정자 권선의 절연열화 특성 (Insulation Aging Properties of Off-Line and On-Line High Voltage Motor Stator)

  • 김희동;이영준;주영호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 C
    • /
    • pp.1694-1696
    • /
    • 2001
  • Partial discharge(PD) tests are used to evaluate the insulation condition of stator windings in six 6.6kV motors. These tests were conducted using a conventional partial discharge detector (PDD), turbine generator analyzer(TGA) and partial discharge analyzer(PDA). Off-line PD measurements were performed on six 6.6kV motors. PD magnitudes ranged from 740 pC to 5,100 pC at the normal line-to-ground voltage. Six 6.6kV motors have been equipped with eighteen 80pF epoxy-mica couplers(one per phase) on the motor terminal boxs. The PD pulse from sensors were measured with the TGA and PDA instruments on a normally operating motors. The PDD, TGA and PDA test results showed that internal discharge was detected in voids of the groundwall insulation.

  • PDF

가스절연개폐장치용 UHF 부분방전검출장치의 새로운 감도 측정방법 (A Novel Sensitivity Verification Method for the UHF Partial Discharge Detection System in Gas Insulated Switchgear (GIS))

  • 구선근;박기준;윤진열
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제50권9호
    • /
    • pp.450-455
    • /
    • 2001
  • We proposed a new sensitivity verification method for the UHF partial discharge(PD) detection system. Initially, we measure the UHF power induced by 5 pC PD which takes place near UHF sensor. Subsequently, we inject the swept UHF signal from a network analyzer into the GIS and measure the attenuation of the signal along the 71S Both the UHF power by 5 pC PD and the attenuation make it possible to verify the sensitivity and spatial coverage of the PD detection system. This method doesn\`t require the calibration of injected pulse type UHF signal into the GIS and makes us precisely measure the attenuation in frequency domain.

  • PDF