• 제목/요약/키워드: Pulse Wave Variables

검색결과 46건 처리시간 0.031초

고혈압 환자의 맥상 연구 (A Study on the Pulse Wave Parameter in Hypertension Patients)

  • 정현정
    • 대한한의진단학회지
    • /
    • 제18권2호
    • /
    • pp.51-62
    • /
    • 2014
  • Objectives The purpose of this study was to determine whether a pulse analyzer was useful to characterize the variables of pulse wave of hypertension (HT), compared with those of normal blood pressure group (NP). Methods The subjects were 22,646 who worked at car manufacturing factory. The pulse wave variables and pulse types measured in Guan by DMP 1000. Results In the main and secondary pulse type, there were significant differences between HT and NP. Whereas, in the field of pulse wave variables, no specific differences were between HT and NP. Conclusion Although pulse wave variables were not statistically significant, pulse analyzer might have reliable diagnostic sensitivity between hypertension and non-hypertension population.

6시그마 기법을 통한 안정된 맥파측정 프로세스 설계 (A Case Study of Six Sigma Project for Improving method of measuring pulse wave)

  • 이전;이유정;이혜정;최은지;김종열
    • 한국한의학연구원논문집
    • /
    • 제12권2호통권17호
    • /
    • pp.85-92
    • /
    • 2006
  • Pulse is one of the basic diagnostic information of TKM(Traditional Korean Medicine). To quantify and standardize pulse diagnosis, we had collected an amount of clinical data from May 2005 by using newly developed pulse analyzer. But there were many noises in pulse wave according to measuring method, environment, operator and condition of patient. So some data can’t be included for analyzing diagnosis. To reduce noises from measuring pulse and to collect reliable pulse wave data, we made the process map of measuring method and applied six sigma project. With this we can improved the method of measuring pulse wave in collecting clinical data. The project follows a disciplined process of five macro phases: define, measure, analyze, improve and control (DMAIC). A process map and C-E diagram are used to identify process input and output variables. The major input variables are selected by using C&E matrix, and process map is developed by analyzing input variables. And the optimum process conditions are going to be controled to avoid in increasing loss of collecting pulse wave data.

  • PDF

당뇨병 환자와 건강인의 맥상과 사상체질에 관한 연구 (Comparative Study on the Pulse Wave Variables and Sasang Constitution in Diabetes Mellitus Patients and Healthy Subjects)

  • 박수정;김경요;이시우;권영미;길은영;주종천
    • 동의생리병리학회지
    • /
    • 제21권6호
    • /
    • pp.1601-1610
    • /
    • 2007
  • The purpose of this study was to determine whether a pulse analyzer was useful 1) to characterize the variables of pulse wave of diabetes mellitus group, compared with those of healthy subjects, and 2) to determine Sasang Constitution in diabetes mellitus group and healthy subjects. 1. The sum of pulse pressure (energy) and the ratio of systolic period area (As%), called pulse pressure-related variables, were higher in diabetes mellitus group than healthy group, while the height of dicrotic wave (h5) and the ratio of height of dicrotic wave to height of percussion wave (h5/h1), correlated with arterial compliance, were lower in diabetes mellitus group than healthy group. 2. Taeumin of diabetes mellitus group showed higher pressure-related variables than that of healthy group. 3. Soumin of diabetes mellitus group had shorter the time to dicrotic wave (t5) than that of healthy group. 4. Soyangin of diabetes mellitus group showed higher heart rates and lower values in pulse wave time-related variables, including time to dicrotic wave(t5), time to incisura (t4), total time minus time to incisura (t-t4), total time (t), width of percussion wave (w), and the ratio of width of percussion wave to total time (w/t), than that of healthy group. 5. Contact pressure (CP), sum of pulse pressure (energy), height of pre-incisura (h2), height of incisura (h4), width of percussion wave (w), time to incisura (t4), time to percussion wave (t1), variance of total time (Vt), variance of height of percussion wave(Vp) and the ratio of height of incisura to height of percussion wave (h4/h1) were used to develop the rules of Sasang Constitution Classification with about seventy five percents accuracy. These suggested that the pulse analyzer was useful to evaluate the risk degree of diabetes mellitus and to determine Sasang Constitution among either diabetes mellitus group or healthy group.

적혈구 용적이 요골 동맥의 맥파에 미치는 영향 (Effect of Hematocrit Level on the Radial Pulse Wave)

  • 유현희;전영주;김재욱;이혜정;우영재;이유정;김종열
    • 동의생리병리학회지
    • /
    • 제23권5호
    • /
    • pp.1035-1040
    • /
    • 2009
  • In this work, we investigate the effect of blood hematocrit level on the radial pulse wave to study the clinical application of the pulse analyzer. For this purpose, we measured the radial pulse wave at the left Gwan for 15 males with abnormal high hematocrit level and 47 males with normal hematocrit level at the age of thirties and forties. Various variables of the radial pulse wave between two groups were analyzed by Student's T test. We found significant differences in several characteristic variables in the amplitude, time-span and the integrated area of the amplitude and time of the pulse wave. The systolic peak in the amplitude of the radial pulse wave was higher in abnormal high hematocrit group. In contrast, the third peak from the second incisure was higher and longer in normal hematocrit group. Our study suggests that the radial pulse wave can be useful in distinguishing the patient group with high hematocrit level and thus with high blood viscosity. Our finding may motivate research activities towards diverse clinical applications of the pulse wave.

성인 남녀의 맥파 차이에 대한 연구 (Study on Sex Difference in the Pulse Wave of Healthy Adults)

  • 유현희;이시우;이전;이유정;김종열
    • 동의생리병리학회지
    • /
    • 제21권5호
    • /
    • pp.1337-1340
    • /
    • 2007
  • Pulse diagnosis is one of the typical examination methods in traditional oriental medicine. However, it is necessary to obtain the objectivity for the standardization of this diagnosis. For this purpose, the pulse analyzer has been devised and studied, and the tonometric pulse analyzer displaying the pulse wave and its variables was developed recently. In this study, we investigated the effect of the sexuality of the individuals on the differences of the pulse wave as well as the correlation between the weight and the pulse wave to interrogate whether the pulse difference is not caused by the difference of sex but the size of individual.

맥상파를 이용한 체질 판별방법에 관한 연구 (Study on the Discrimination of Constitution Using Pulse Wave)

  • 신상훈;김종열
    • 동의생리병리학회지
    • /
    • 제22권6호
    • /
    • pp.1403-1409
    • /
    • 2008
  • The purpose of this study is to develop the systematic process on the discrimination of Sasang constitution with the pulse diagnosis apparatus. The pulse waves were acquired at the right and the left Guan point with 1420 people who were apparently healthy. In order to minimize the effect of aging on the shape of pulse wave, the age groups of 30s, 40s, and 50s were used. Taeum group was the best to classify, Soyang group was the worst. With the same group size, the sensitivity of Soyang group was increased. Input variables were selected with the consideration of the floating-sink ratio, tests of equality of group means, multiple comparison, multicollinearity, and structure matrix. To increase the sensitivity of Soyang, the variables which could tell the difference between Soyang and Soeum were selected.

대사증후군을 동반한 허혈성 뇌혈관 질환 환자의 맥파속도에 관한 연구 (Determinants of the Brachial-ankle Pulse Wave Velocity in Patients with Metabolic Syndrome and Ischemic Stroke)

  • 김동웅;박보라
    • 동의생리병리학회지
    • /
    • 제25권3호
    • /
    • pp.551-557
    • /
    • 2011
  • The purpose of this study is to investigate the relation between brachial-ankle pulse wave velocity and the features of metabolic syndrome, and differences according to sex in patients diagnosed cerebral infarction. The study group comprised 61 patients over age 30 who were diagnosed cerebral infarction, accompanied with metabolic syndrome. The brachial-ankle pulse wave velocity, blood pressure, lipid profiles, fasting blood glucose, body mass index were measured. Also we checked past history of patients. Then we analyzed the association between brachial-ankle pulse wave velocity and the features of metabolic syndrome. Pearson correlation analysis reflected the variables affecting the brachial-ankle pulse wave velocity as follows : Age, SBP(systolic blood pressure), DBP(diastolic blood pressure), FBS(fasting blood glucose) were positively correlated. As a result of regression analysis, in patients with cerebral infarction accompanied with metabolic syndrome, the brachial-ankle pulse wave velocity is affected by age to men, SBP, FBS, DBP to women. The brachial-ankle pulse wave velocity is not affected by the components of metabolic syndrome, except blood pressure, FBS, in patients with ischemic stroke.

침자극이 좌관맥상과 심박수 미세변화에 미치는 영향 (Study on the Radial Pulse Wave Variables and Heart Rate Variability after Acupuncture Stimulation)

  • 원재균;정순관;김동은;임진영;권영달;염승룡;이수경;송용선
    • 동의생리병리학회지
    • /
    • 제23권1호
    • /
    • pp.237-244
    • /
    • 2009
  • We investigated the effects of acupuncture stimulation on pulse wave variables and heart rate variability (HRV) in healthy adults. To evaluate twenty healthy volunteers (10 men, 10 women) had acupuncture into both Hapkok (Ll4) and Taechung (Liv3) for 15 minutes. Radial pulse, Heart Rate Variability, body temperature and blood pressure were checked before and after acupuncture to evaluate Pulse Wave Variability and Autonomous Function. The results were as follows; Heart rate was significantly increased while systolic blood pressure (mmHg) and diastolic blood pressure (mmHg) were significantly increased after acupuncture treatment. Sixteen subjects didn't change representative pulse wave variables after acupuncture treatment. Energy, height of main peak (H1), height of pre-dicrotic valley (H2) and height of descending valley (H4) were decreased while height of dicrotic peak (H5) was significantly decreased after acupuncture treatment. Time to main peak (T1), time to pre-dicrotic valley (T2), time to dicrotic peak (T5), total time (T) and T-T4 were decreased while time to descending valley (T4) was increased after acupuncture treatment. Total area (At), area of main peak (Aw) and ratio of diastolic period area (Ad) were decreased while ratio of systolic period area (As) and angle of main peak (MPA) were increased after acupuncture treatment. The standard deviation of all normal RR intervals (SDNN) was increased while the root mean square of successive differences between the normal heart beats (RMSSD) was significantly increased after acupuncture treatment by time domain analysis. Low frequency power (LF) and LF/HF ratio were decreased while high frequency power (HF) was significantly increased after acupuncture treatment by frequency domain analysis. This study suggests that acupuncture treatment changes pulse wave variability and heart rate variability. Further study on various acupuncture treatment for pulse wave variability and heart rate variability is required.

펜타입 압저항 센서를 활용한 연령별 맥파 특성 및 맥파의 대사증후군에의 적용 가능성 평가 (Characteristics of Pulse Waves in Various Age Categories and Applicability of Pulse Wave to Metabolic Syndrome Using Pen-type Piezoresistive Sensor)

  • 하예진;조문영;윤종민;전규상;박수정;신선호
    • 대한한방내과학회지
    • /
    • 제33권3호
    • /
    • pp.257-271
    • /
    • 2012
  • Objectives : The purpose of this study was to confirm that the pulse analyzer is useful for analyzing characteristics of variables of pulse waves in age categories, evaluating pulse waves of the metabolic syndrome group, compared with those of the non-metabolic syndrome group in Korean adults. Methods : The pulse wave variables were measured in Guan of all 1,056 subjects by the pulse analyzer, using a pen-type piezoresistive sensor. The physical measurement, blood test and survey were also performed by each subject. Results : In the age categories, height of pre-incisura (h2), height of tidal wave (h3), area of percussion wave (Aw), and width of percussion wave (w) increased in accordance with increase in age. While ratio of systolic period area (As) went up according to the increase of age, ratio of diastolic period area (Ad) went down. Radial augmentation index (R-AI), h2/h1, h3/h1, w/t and angle of percussion wave went up by aging, generally. Aw rate (Aw/At) also increased. Among the metabolic syndrome group, in the ages of 19 and 44, ratio of systolic period area (As) was higher and ratio of diastolic period area (Ad) was lower than in the non-metabolic group. w/t, Aw/At, and angle of percussion wave were higher than in the non-metabolic syndrome group. Among the metabolic syndrome group over the age of 60, height of pre-incisura (h2), height of tidal wave (h3), total area (At), area of percussion wave (Aw), radial augmentation index (R-AI), h2/h1 and h3/h1 were higher than in the non-metabolic syndrome group. Conclusions : The pulse analyzer is useful to analyze arterial stiffness in the age categories and in the metabolic syndrome group by some measures.

식사가 정상인의 맥에 미치는 영향 분석 (Effect of Taking Meal on Pulse Diagnosis in Healthy Subjects)

  • 이유정;이전;이혜정;최은지;김종열
    • 동의생리병리학회지
    • /
    • 제21권6호
    • /
    • pp.1670-1675
    • /
    • 2007
  • The pulse diagnosis studies reported to date has mainly been performed to clinically reveal the pulse wave characteristics according to the specific diseases, whereas no attempts have been made to study the effects on the pulse wave characteristics of the daily activities such as taking meals, exercise, and sleep, etc. This work reports the effect of feeding stimulus on the healthy subjects on the pulse wave pattern which has quantitatively been analyzed using the objective model for the pulse diagnosis in oriental medicine. The pulse waves right before/after the meal and 30 minutes after the meal were measured using the pulse analyzing equipment (3D-Mac, Daeyo Medi, Korea) and at the same time oriental medicine doctors' diagnoses were given. The pulse parameters obtained from the equipment and clinical records on the subjects were statistically processed and the variables showing statistically significant differences were analyzed. The results indicate that the pulse pressure, the pulse rate, and the respiratory rate increase while the blood pressure decreases after the meal. For the floating/sinking and the deficient/excess coefficients characterizing the pulse states described in the oriental medicine, the floating/sinking coefficients were observed to decrease whereas the deficiency/excess coefficients increase after the meal. The results indicates that besides the standard bio-indicators like blood pressure and respiratory rate, etc., the pulse wave characterization in terms of the pulse classifications in the oriental medicine using the floating/sinking, deficient/excess pulse states provide an important piece of biomedical information.