• Title/Summary/Keyword: Pulse Transformer

Search Result 260, Processing Time 0.027 seconds

Overload Characteristics Analysis of Phase Controlled Rectifier for Plasma Application (플라즈마 응용을 위한 위상제어 정류기의 과부하 특성해석)

  • 노의철;정규범;김용진;최정완
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1996.11a
    • /
    • pp.104-108
    • /
    • 1996
  • This paper deals with the design considerations and characteristics analysis of a SCR rectifier in pulsed over load operation. The Pulse repetition rate is one every 150 seconds and each current pulse width is 10 seconds. Therefore the characteristics of the transformer and SCR rectifier which consist the pulsed DC power supply are different from those of the conventional AC/DC power converters having continuous load. The variations of the DC output voltage drop, PF and THD versus the %Z of the transformer is analyzed through simulations and the experimental results thought to be useful in design high power pulsed DC power suppler.

  • PDF

A Novel Quasi-Resonant ZCS-PFM DC-DC Switching Regulator with Loosely-Coupled Flyback Inductors

  • Chu E.H.;Chandhaket S.;Moisseev S.;Hiraki E.;Nakaoka M.;Kifune H.
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.266-270
    • /
    • 2001
  • This paper presents a novel topological prototype of voltage source series quasi-resonant zero current soft-switching pulse frequency modulated dc-dc power converter circuit using IGBTs which incorporates a high-frequency flyback transformer link. Its steady-state operating principle is described on the basis of simulation analysis, along with the open loop controlled power regulation characteristics of the multi-functional coupled inductors linked dc-dc power converter operating under a principle of zero current soft switching commutation.

  • PDF

The Quantitative Analysis of the Superposed Ultrasonic Signal by PD Sources in a Transformer (부분방전원에 의해 중첩된 초음파신호의 정량적분석)

  • 송현석;구교선;이동준;곽희로
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2001.11a
    • /
    • pp.163-166
    • /
    • 2001
  • In this paper, the superposition of ultrasonic signals which were generated by multi-source in a transformer was presented. For analysis of ultrasonic superposition, V$_{peak-peak}$ and pulse number of ultra-sonic signal were used. As a result, the wave form of ultrasonic superposition was classified into three types ; First type was the wave form whose V$_{peak-peak}$ was increased by the superposition of each signal's V$_{peak-peak}$. Second type was wave form whose V$_{peak-peak}$ was decreased by the superposition of each signal's V$_{peak-peak}$. And the other type was wave form whose peals were two or mere. And V$_{peak-peak}$ of superposed ultrasonic wave wads mostlv increased or decreased and pulse number of supe게osed u1trasonic wave was mostly increased.y increased.

  • PDF

Mitigation of Voltage Sag and Swell Using Direct Converters with Minimum Switch Count

  • Abuthahir, Abdul Rahman Syed;Periasamy, Somasundaram;Arumugam, Janakiraman Panapakkam
    • Journal of Power Electronics
    • /
    • v.14 no.6
    • /
    • pp.1314-1321
    • /
    • 2014
  • A new simplified topology for a dynamic voltage restorer (DVR) based on direct converter with a reduced number of switches is presented. The direct converter is fabricated using only three bi-directional controlled switches. The direct converter is connected between the grid and center-tapped series transformer. The center-tapped series transformer is used to inject the compensating voltage synthesized by the direct converter. The DVR can properly compensate for long-duration, balanced, and unbalanced voltage sag and swell by taking power from the grid. The switches are driven by ordinary pulse width modulation signals. Simulation and hardware results validate the idea that the proposed topology can mitigate sag of 50% and swell of unlimited quantity.

A Tightly Regulated Triple Output Asymmetrical Half Bridge Flyback Converter

  • Hyeon, Byeong-Cheol;Cho, Bo-Hyung
    • Journal of Power Electronics
    • /
    • v.10 no.1
    • /
    • pp.14-20
    • /
    • 2010
  • In this paper, a tightly regulated triple output asymmetrical half bridge flyback (ASHF) converter is proposed. In order to regulate all output voltages, pulse frequency modulation (PFM), pulse width modulation (PWM) and phase delay (PD) are used simultaneously. In comparison with the conventional PWM-PD method, the interactions among the control variables are minimized and the operating range is increased. By the utilization of a multi winding transformer, the auxiliary transformer and the blocking capacitor are eliminated and the size and cost of the proposed converter is reduced. The operation principle of the converter is explained and the modes of operation are investigated. Based on the results, the steady state characteristics of the converter are explored. A 24V/10A, 12V/5A, 5V/10A hardware prototype is built and tested to verify the analysis results and the voltage regulation of the triple outputs of the proposed converter.

Power Supply for LCO Cleaning Plasma (LCD 세정용 상압 플라즈마 전원장치)

  • Cho, Hyung-Ki;Kim, Gyu-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2006.04a
    • /
    • pp.282-284
    • /
    • 2006
  • UV lamp systems have been used for cleaning of display pannels of TFT LCD or Plasma Display Pannel (PDP). However, the needs for high efficient cleaning and low cost made high voltage plasma cleaning techniques be developed and improved. In this paper, 3kW high voltage plasma power supply system was developed for LCD cleaning. The 3-phase input voltage is rectified and then inverter system is used to make a high frequency pulse train, which is rectified after passing through a high-power transformer. Finally, bi-directional high voltage pulse switching circuits are used to generate the high voltage plasma.

  • PDF

Detection and Location of Partial discharge in Transformers Using Logoski coil and Ultrasonic sensor (로고스키 코일과 초음파 센서를 이용한 변압기내 부분방전 탐지 및 위치검출)

  • Kwak, Hee-Ro;Kim, Jae-chul;Kim, Eung-Sang;Han, Min-Koo;Kwan, Tae-Won;Yoon, Young-Beum
    • Proceedings of the KIEE Conference
    • /
    • 1990.07a
    • /
    • pp.279-282
    • /
    • 1990
  • This paper describes an nstrument for the detection and geometric location of partial discharge(PD) sources in transformers. This instrument measures electric current pulses and ultrasonic pulses simultaneously, counts the number of electrical pulse and determines the geometric location of PD in transformers. It was found that there is a relationship between partial discharge magnitude and pulse repetition rate when the applied test voltage and oil temperature were varied. Through the laboratory test using model transformer, it was clarified that this detector could be used, satisfactory for detecting and locating of PD in the transformer.

  • PDF

A Design and Implementation of 30w class Er:YAG laser adopted skin and dental clinic. (치과 및 교부과용 30W급 Er:YAG 레이저 설계 및 구현)

  • 김휘영;신경애
    • Proceedings of the IEEK Conference
    • /
    • 2001.06e
    • /
    • pp.211-214
    • /
    • 2001
  • For general laser power supply, the secondary of the power transformer is connected to the rectifier and filter capacitor. The output of a rectifier is connected to a switching element in the secondary of the transformer. So the Dower supply is complicated and the loss of switching is considerably. In addition, according to increasing pulse repetition, charged energy of energy-storage capacitor is not transferred sufficiently to flashlamp, and laser output efficiency decreases. In this raper, to improve laser efficiency, we designed and fabricated the power supply in which the SCR was turned on in zero point by the methods of ZCC(zero crossing control), PFN(pulse forming network) in result, laser output efficiency increased by hte 4% other than conventional supply, when a repetition rate was increased by the 10[pps], In 20(pps), efficiency was increased by about 8%

  • PDF

A New High Efficiency Half Bridge Converter with Improved ZVS Performance

  • Lee Sung-Sae;Han Sang-Kyoo;Moon Gun-Woo
    • Journal of Power Electronics
    • /
    • v.6 no.3
    • /
    • pp.187-194
    • /
    • 2006
  • A new asymmetrical pulse width modulation (PWM) half bridge converter with improved ZVS performance is proposed. The ZVS operation of the proposed converter can be maintained from no load to full load conditions since the magnetizing current of the transformer contributes to the ZVS operation at light loads without considerable conduction loss of the transformer and switch. Synchronous rectification is employed to reduce the rectification loss. Operational principles, large signal modeling, ZVS analysis and design equations are presented. Experimental results demonstrate that the proposed converter can achieve a large ZVS range and significant improvement in efficiency for a 100W (5V, 20A) prototype converter.

The study of Pulse Transformer for a long-distance Serial Communication (원거리 직렬 통신을 위한 펄스트랜스포머에 관한 연구)

  • Seo, Yong-Won;Yeon, Jun-Sang;Yang, O
    • Proceedings of the KIEE Conference
    • /
    • 2003.11c
    • /
    • pp.975-978
    • /
    • 2003
  • 본 논문에서는 주변의 잡음에 의해 통신 환경이 나쁜 시스템에서 통신의 안정성과 고속성과 원거리 통신의 구현을 중점으로 연구하였다 전동차와 같이 Serial Communication을 이용해 차량사이 통신을 하는 경우 주변의 고전압, 고전류의 잡음에 의해 통신 Packet이 파손될 수 있으며 심지어 통신 모들이 파괴되는 현상도 발생한다. 이를 위해 펄스트랜스 포머를 사용해 Hardware의 보호 뿐아니라 고속의 안정적인 통신을 현 할 수 있다. 이는 펄스트랜스 포머의 특성상 하드웨어적으로 분리된 통신선과 통신모듈로 인한 안정성과 원거리 통신을 실현 하였으며 동기통신을 통한 빠른 속도와 FM0, FM1, Manchester 부호 방식에 의한 빠르고 안정한 통신을 제공하기 때문이다.

  • PDF