• Title/Summary/Keyword: Pulse Sampling

Search Result 139, Processing Time 0.04 seconds

An Effect of Sampling Rate to the Time and Frequency Domain Analysis of Pulse Rate Variability (샘플링율이 맥박변이도 시간 및 주파수 영역 분석에 미치는 영향)

  • Yang, Yoon La;Shin, Hangsik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.7
    • /
    • pp.1247-1251
    • /
    • 2016
  • This study aims to investigate the effect of sampling frequency to the time domain and frequency domain analysis of pulse rate variability (PRV). Typical time domain variables - AVNN, SDNN, SDSD, RMSSD, NN50 count and pNN50 - and frequency domain variables - VLF, LF, HF, LF/HF, Total Power, nLF and nHF - were derived from 7 down-sampled (250 Hz, 100 Hz, 50 Hz, 25 Hz, 20 Hz, 15 Hz, 10 Hz) PRVs and compared with the result of heart rate variability of 10 kHz-sampled electrocardiogram. Result showed that every variable of time domain analysis of PRV was significant at 25 Hz or higher sampling frequency. Also, in frequency domain analysis, every variable of PRV was significant at 15 Hz or higher sampling frequency.

Estimation of PTT (Pulse Transit Time) by Multirate Filtering Analysis (다중레이트 필터링 기법을 이용한 맥파전달시간 추정)

  • Kim, Hyun-Tae;Kim, Jeong-Hwan;Kim, Kyeong-Seop;Lee, Jae-Ho;Lee, Jeong-Whan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.7
    • /
    • pp.1020-1026
    • /
    • 2013
  • Multirate filtering process on the biological signals like Electrocardiogram (ECG) and Photoplethysmogram (PPG) can be defined as the digital signal processing algorithm in which the sampling rate varies to omit or interpolate the intermediate values between the sampled data. With this aim, we suggest a new multirate filtering algorithm by deleting the extraneous data to eliminate the unwanted degradations such as granular noise due to the usage of high sampling frequency and simultaneously to detect the fiducial features of ECG and PPG with reducing the complexity of resolving fiducial points such as R-peak, Pulse peak and Pulse Transit Time (PTT). After the experimental simulations performed, we can conclude the fact that we can detect the fiducial features of ECG and PPG signal in terms of R-peak, Pulse peak and PTT without the loss of accuracy even if we do not maintain the original sampling frequency.

Construction of a robust tracking system with N-th sampling delay

  • Inooka, Hikaru;Ichirou, Komatsu Ken
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.87.5-87
    • /
    • 2001
  • In the past, we presented the tracking system with one sampling delay. In this paper, first we propose a tracking system with N-th sampling delay, in the case where an input-output pulse transfer function of a plant Z$\_$-N/. Secondly we propose a system configuration converting an input-output pulse transfer function of a plant into Z$\_$-N/ with the inverse system of the plant. Moreover, the proposed tracking system configuration is applied to an actual Ball and Beam system and good results are obtained.

  • PDF

Pulse Dual Slope Modulation for VLC

  • Oh, Minseok
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.8 no.4
    • /
    • pp.1276-1291
    • /
    • 2014
  • In the field of visible light communication (VLC), light-emitting diodes (LEDs) are used for transmitting data via visible light. In this study, we analyze pulse dual slope modulation (PDSM) as a means of delivering information in VLC. PDSM involves the modulation of symmetrical slope pulses to encode binary 0s and 1s, and owing to the moderately increasing and decreasing pulse shapes that are created, this method enables more spectral efficiency than the variable pulse position modulation (VPPM) technique currently adopted in IEEE 802.15.7. In particular, PDSM allows for the avoidance of intra-frame flicker by providing idle pulses in a spectrum-efficient way. A simple detection scheme is proposed for PDSMsignals, and its bit error rate (BER) is analyzed mathematically at varying slopes to validate the process through simulation. The BER performance of PDSM detection using dual sampling is compared to the performances of PDSM and VPPM using correlation detection. It is found that, when the probability of idle pulse transmission is less than 0.08 and higher than 0, the BER of dual sampling PDSM is lower than that of PDSM using correlation detection over the entire light intensity range.

Proposal of pulse parameter useful for pulse wave analysis in oriental medicine: Preliminary study on floating and sinking pulses (통계분석을 통한 한의 맥진에 유용한 파라미터 도출: 부침맥을 중심으로 한 예비연구)

  • Lee, Jeon;Lee, Yu-Jung;Lee, Hae-Jung;Choi, Eun-Ji;Kim, Jong-Yeol
    • Proceedings of the KIEE Conference
    • /
    • 2006.10c
    • /
    • pp.244-246
    • /
    • 2006
  • In this study, we search some parameters well-related to floating-sinking pulse by statistical analysis, because these pulses are frequently used in clinic. Pulse signals were acquired by 3D pulse analyzer and 30 subjects consist of 15 people diagnosed as floating pulse and 15 people diagnosed as sinking pulse by oriental doctors who have over 5 years clinical experience. Then, we made a representative beat template for each subject and, through a peak detection algorithm, we calculated several pulse parameters. To find the parameters related to floating-sinking pulse, we performed statistical testing with 17 parameters through the independence sampling, t-test. As a result, there is the biggest difference between pressure, the maximum pulse pressure, diastolic area(Ad) and float-sink data. (p < .05).

  • PDF

Analysis of SNR gain of the Receiver Filter in WCDMA (WCDMA환경의 수신기 필터에 의한 SNR이득 분석과 최적구조 도출)

  • Jeon, Hyeon-Jin;Chang, Tae-Gyu
    • Proceedings of the KIEE Conference
    • /
    • 2007.04a
    • /
    • pp.283-285
    • /
    • 2007
  • 본 논문에서는 WCDMA 환경에서의 수신기 Filter에 의한 SNR개선에 대해 연구하였다 WCDMA환경에서 여러 사용자의 다중경로 신호들이 더해져서 수신되는데 원하는 사용자에 동기를 맞춰 chip rate의 정수배로 sampling하고 수신기 필터를 통과시킴으로써 배율 정도에 따른 이득을 얻게 된다. 하지만 송신 신호의 pulse shape에 따라 이득이 달라진다. pulse shape에 따라 필터에 대한 윈하는 사용자 신호와 AWCN의 아득이 서로 달라지고 SNR이득이 포화되는 시점도 다르기 때문이다. 따라서 pulse shape에 따라 최적의 SNR이득을 얻기 위한 최적의 sampling 배출을 구할 수 있다. 분 논문에서는 signal shape에 따른 SNR 이득에 대해 해석식 도출 및simulation을 통해 최적 수신기 구조를 도출하였다.

  • PDF

A Study on Factors Influencing P-wave Velocity of Concrete (콘크리트의 P파 속도에 영향을 주는 인자에 관한 연구)

  • 이광명;이회근;김동수;김지상
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1998.10b
    • /
    • pp.725-730
    • /
    • 1998
  • Recently, non-destructive tests are getting popular in evaluating concrete properties without braking specimens. Among several NDT methods, P-wave velocity measurement technique has been widely used to evaluate the stiffness and strength of concrete. The purpose of this study is to investigate factors influencing P-wave velocity measured by impact-resonant method and ultrasonic pulse velocity method, such as moisture content of concrete, existence and size of coarse aggregates, sensor and sampling rate. Test results show that rod-wave velocity measured by impact-resonant method and ultrasonic pulse velocity are significantly affected by the moisture content of concrete, i.e., the lower moisture content, the lower velocity. Moisture content influences rod-wave velocity stronger than ultrasonic pulse velocity. Rod-wave velocity is faster in concrete than in mortar and is also faster in concrete containing small size aggregates. Sensor and sampling rate have little influence on velocity.

  • PDF

A Study on Performance Improvement of Active Noise Control Using Synchronous Sampling Method (동기화한 이산화법을 이용한 능동소음제어의 성능향상에 관한 연구)

  • Kim, Heung-Seob;Oh, Jae-Eung;Shin, Joon
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.10
    • /
    • pp.2523-2532
    • /
    • 1994
  • In this paper, active noise control is performed in a duct system using the periodic pulse train which corresponds to the periodic component of noise source as a reference signal. Control algorithm applied in this study is possible to eliminate the acoustic feedback which occurs in the conventional filtered-x and filtered-u LMS algorithm by using electrical reference signal and has the fast adaptation speed with low filter orders by using synchronous sampling method is discussed via computer simulations and experiments of case studies such as frequency modulation, amplitude modulation and frequency differency between source signal and reference signal.

A Background Subtraction Algorithm for Fence Monitoring Surveillance Systems (담장 감시 시스템을 위한 배경 제거 알고리즘)

  • Lee, Bok Ju;Chu, Yeon Ho;Choi, Young Kyu
    • Journal of the Semiconductor & Display Technology
    • /
    • v.14 no.3
    • /
    • pp.37-43
    • /
    • 2015
  • In this paper, a new background subtraction algorithm for video based fence monitoring surveillance systems is proposed. We adopt the sampling based background subtraction technique and focus on the two main issues: handling highly dynamic environment and handling the flickering nature of pulse based IR (infrared) lamp. Natural scenes from fence monitoring system are usually composed of several dynamic entities such as swaying trees, moving water, waves and rain. To deal with such dynamic backgrounds, we utilize the confidence factor for each background value of the input image. For the flickering IR lamp, the original sampling based technique is extended to handle double background models. Experimental results revealed that our method works well in real fence monitoring surveillance systems.