• Title/Summary/Keyword: Pulse Rate

Search Result 1,682, Processing Time 0.046 seconds

Identification of an effective and safe bolus dose and lockout time for patient-controlled sedation (PCS) using dexmedetomidine in dental treatments: a randomized clinical trial

  • Seung-Hyun Rhee;Young-Seok Kweon;Dong-Ok Won;Seong-Whan Lee;Kwang-Suk Seo
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.24 no.1
    • /
    • pp.19-35
    • /
    • 2024
  • Background: This study investigated a safe and effective bolus dose and lockout time for patient-controlled sedation (PCS) with dexmedetomidine for dental treatments. The depth of sedation, vital signs, and patient satisfaction were investigated to demonstrate safety. Methods: Thirty patients requiring dental scaling were enrolled and randomly divided into three groups based on bolus doses and lockout times: group 1 (low dose group, bolus dose 0.05 ㎍/kg, 1-minute lockout time), group 2 (middle dose group, 0.1 ㎍/kg, 1-minute), and group 3 (high dose group, 0.2 ㎍/kg, 3-minute) (n = 10 each). ECG, pulse, oxygen saturation, blood pressure, end-tidal CO2, respiratory rate, and bispectral index scores (BIS) were measured and recorded. The study was conducted in two stages: the first involved sedation without dental treatment and the second included sedation with dental scaling. Patients were instructed to press the drug demand button every 10 s, and the process of falling asleep and waking up was repeated 1-5 times. In the second stage, during dental scaling, patients were instructed to press the drug demand button. Loss of responsiveness (LOR) was defined as failure to respond to auditory stimuli six times, determining sleep onset. Patient and dentist satisfaction were assessed before and after experimentation. Results: Thirty patients (22 males) participated in the study. Scaling was performed in 29 patients after excluding one who experienced dizziness during the first stage. The average number of drug administrations until first LOR was significantly lower in group 3 (2.8 times) than groups 1 and 2 (8.0 and 6.5 times, respectively). The time taken to reach the LOR showed no difference between groups. During the second stage, the average time required to reach the LOR during scaling was 583.4 seconds. The effect site concentrations (Ce) was significantly lower in group 1 than groups 2 and 3. In the participant survey on PCS, 8/10 in group 3 reported partial memory loss, whereas 17/20 in groups 1 and 2 recalled the procedure fully or partially. Conclusion: PCS with dexmedetomidine can provide a rapid onset of sedation, safe vital sign management, and minimal side effects, thus facilitating smooth dental sedation.

Pediatric Endoscopic Sedation in Korea: A Survey of the Korean Society of Pediatric Gastroenterology, Hepatology and Nutrition (소아청소년 진정내시경: 대한소아소화기영양학회 학술위원회 조사 보고)

  • Ryoo, Eell;Kim, Kyung-Mo
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.11 no.1
    • /
    • pp.21-27
    • /
    • 2008
  • Purpose: The aim of this survey was to analyze the choice of sedative drugs and their side effects during pediatric endoscopic sedation in Korea. We also evaluated doctors, caretakers and patient satisfaction with the procedures. Methods: Between June 2006 and July 2006, a 16-item survey regarding current sedation practices, during one month, was mailed to 28 hospitals in Korea. The results of the survey responses were then analyzed. Results: Endoscopy performed under conscious sedation was reported in 89.0% of the responders and endoscopy under general anesthesia in 0.9% of 465 endoscopic procedures. Endoscopy under conscious sedation was performed in 89.1% for upper gastrointestinal endoscopy (GFS) and 88.1% for lower GFS. Midazolam was used for conscious sedation during the endoscopy in 84.5% of cases and propofol was used in two cases (0.5%). In addition, a bezodiazepine/opioid combination was used iin 84.6% (44 cases) for lower GFS. Patients were monitored with pulse oxymetry, EKG (91.4%) as well as automatic BP (5.1%). Transient hypoxia was the only side effect noted and was treated with supplemental oxygen (4.6%). Flumazenil was used in 2.71% of cases. The choice of sedation was made by the endoscopist (84%). The satisfaction rate for endoscopists was 68%, and for the patients and caretakers was 84% (as reported by the endoscopists). Conclusion: Midazolam was used only for the upper GFS and benzodiazepine/opioid combination was used for the lower GFS in Korea. The rate of satisfaction was relatively high and there were no significant side effects noted during the endoscopy under conscious sedation.

  • PDF

The Effects on Dose Distribution Characteristics by Changing Beam Tuning Parameters of Digital Linear Accelerator in Medicine (의료용 디지털 선형가속기의 빔조정 인자변화가 선량분포특성에 미치는 영향)

  • 박현주;이동훈;이동한;권수일;류성렬;지영훈
    • Progress in Medical Physics
    • /
    • v.10 no.1
    • /
    • pp.17-22
    • /
    • 1999
  • INJ-I, INJ-E, PFN, BMI, and PRF were selected among the various factors which constitute a digital linear accelerator to find effects on the dose distribution by changing current and voltage within the permitted scale which Mevatron automatically maintained. We measured the absorbed dose using an ion chamber, analyzed the waveform of beam output using an oscilloscope, and measured symmetry and flatness using a dosimetry system. An RFA plus (Scanditronix, Sweden) device was used as a dosimetry system. Then an 0.6cc ion chamber (PR06C, USA), an electrometer (Capintec192, USA), and an oscilloscope (Tektronix, USA) were employed to measure the changes on the dose distribution characteristics by changing the beam-tuning parameters. When the currents and the voltages of INJ-I, INJ-E, PFN, BMI, and PRF were modified, we were able to see the notable change on the dose rate by examining the change of the output pulse using the oscilloscope and by measuring them using the ion chamber. However, the results of energy and flatness graph from RF A plus were almost identical. The factors had fine differences: INJ-I, INJ-E, PFN, BMI, and PRF had 0.01∼0.02% differences in D10/D20, 0.1∼0.2 % differences in symmetry, and 0.1∼0.4% differences in flatness. Since Mevatron controlled itself automatically to keep the reference value of the factor, it was not able to see large differences in the dose distribution. There were fine differences on the dose rate distribution when the voltage and the currents of the digitized factors were modified Nonetheless, a basic operational management information was achieved.

  • PDF

Real-Time 3D Ultrasound Imaging Method Using a Cross Array Based on Synthetic Aperture Focusing: I. Spherical Wave Transmission Approach (합성구경 기반의 교차어레이를 이용한 실시간 3차원 초음파 영상화 기법 : I. 구형파 송신 방법)

  • 김강식;송태경
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.5
    • /
    • pp.391-401
    • /
    • 2004
  • 3D imaging systems using 2D phased arrays have a large number of active channels, compelling to use a very expensive and bulky beamforming hardware, and suffer from low volume rate because, in principle, at least one ultrasound transmit-receive event is necessary to construct each scanline. A high speed 3D imaging method using a cross array proposed previously to solve the above limitations can implement fast scanning and dynamic focusing in the lateral direction but suffer from low resolution except at the fixed transmit focusing along the elevational direction. To overcome these limitations, we propose a new real-time volumetric imaging method using a cross array based on the synthetic aperture technique. In the proposed method, ultrasound wave is transmitted successively using each elements of an 1D transmit array transducer, one at a time, which is placed along the elevational direction and for each firing, the returning pulse echoes are received using all elements of an 1D receive array transducer placed along the lateral direction. On receive, by employing the conventional dynamic focusing and synthetic aperture method along lateral and elevational directions, respectively, ultrasound waves can be focused effectively at all imaging points. In addition, in the proposed method, a volume of interest consisting of any required number of slice images, can be constructed with the same number of transmit-receive steps as the total number of transmit array elements. Computer simulation results show that the proposed method can provide the same and greatly improved resolutions in the lateral and elevational directions, respectively, compared with the 3D imaging method using a cross array based on the conventional fixed focusing. In the accompanying paper, we will also propose a new real-time 3D imaging method using a cross array for improving transmit power and elevational spatial resolution, which uses linear wave fronts on transmit.

Comparison of Treadmill and Cycle Ergometer in Male Korean College Students (한국 남자 대학생을 대상으로 시행한 Cardiopulmonary Exercise Test에서 Treadmill과 Cycle Ergometer의 비교 분석)

  • Chang, Yoon-Soo;Park, Jae-Min;Choi, Seung-Won;Ahn, Gang-Hyun;Lee, Jun-Gu;Yang, Dong-Kyu;Kim, Se-Kyu;Chang, Jun;Ahn, Chul-Min;Kim, Seong-Kyu;Lee, Won-Yong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.47 no.1
    • /
    • pp.26-34
    • /
    • 1999
  • Background : Generally $VO_2$ max is higher in treadmill exercise than cycle ergometer exercise. According to Hassen and Wasserman, $VO_2$ max with treadmill exercise is higher at ratio of 1.11 than that with cycle ergometer. $VO_2$ max also is influenced by race, sociocultural background, exercise habit In this study, $VO_2$ max and AT were evaluated between Treadmill and cycle exercise in male Korean college students. Method: Study subjects were 44 male college students. We randomized them into 2 groups; 24 students did treadmill exercise at first and 1 week later did cycle ergometer. Another 20 students did in opposite method. They made symptom limited maximal exercise. Author defined maximal exercise as followings: 1) respiratory exchange ratio(RER)> 1.1, 2) plateau>30 sec, 3) heart rate reserve(HRR) <15%, or 4) breathing reserve (BR)<30%. Otherwise their results are excluded as submaximal exercise. Anaerobic threshold(AT) was estimated by V-slope method. Results: $VO_2$ max and AT was $45.1{\pm}6.66m\ell$/kg/min and $26.0{\pm}6.78m\ell$/kg/min in treadmill and $34.9{\pm}5.89m\ell$/kg/min, $19.5{\pm}4.77m\ell$/kg/min in Cycle Ergometer. The measured-$VO_2max$/pred-$VO_2max$ was $98.8{\pm}13.24%$ in treadmill; $84.4{\pm}13.42%$ in cycle ergometer. Comparing $VO_2$ max in treadmill with that obtained by Hassen's method, there were significant differences.(p<0.01). At maximal exercise there were differences in HRR, $O_2$/pulse, BR, $V_E$/MVV, $V_E/VCO_2$ between treadmill and cycle but not in $V_E/VO_2$, Vd/Vt, Ti/Ttot. At AT there were differences in $O_2$/pulse, BR, $V_E$/MVV, Ti/Ttot between treadmill and cycle, otherwise not. Conclusion: According to the result of this study, there are larger gap between treadmill and cycle ergometer in normal Korean adults than foreign data, and it needs further study to obtain reference value of Korea.

  • PDF

The Respiratory and Hemodynamic Effect of Prone Position in Patients with ARDS (급성호흡부전증후군에서 Prone Position의 호흡 및 혈류역학적 효과)

  • Lim, Chae-Man;Koh, Youn-Suck;Jung, Bok-Hyun;Lee, Sang-Do;Kim, Woo-Sung;Kim, Dong-Soon;Kim, Won-Dong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.5
    • /
    • pp.1105-1113
    • /
    • 1997
  • Background : Prone position improves oxygenation in some patients with ARDS. According to some authors, prone position can also improve the deteriorated hemodynamics induced by PEEP. But these respiratory and hemodynamic effects of prone position has not yet been fully established. Methods : Twentythree consequtive patients with ARDS(M : F= 11 : 12, $62.1{\pm}20.8yrs$) were the subjects for this study. ABGA, static compliance of the respiratory system, mean arterial pressure and pulse rate were obtained in supine position and at 5min, 0.5h and 2h of prone position. Positive respiratory response was defined as 20mmHg or more increase in $PaO_2/FIO_2$ within 2h of prone position. Early of late respiratory responses were defined if the positive response was observed within of after 3 day of ARDS onset, respectively. Positive hemodynamic response was defined as 10mmHg or more increase in mean arterial pressure at 5min of prone position. Results : Fifteen patients (65%) showed positive respiratory response. In the respiratory responders, $PaO_2$ was $69.8{\pm}17.6mmHg$ in supine position, $83.2{\pm}22.6mmHg$ in prone position 0.5h, $96.8{\pm}22.7mmHg$ in prone position 2h(p<0.001), and $PaO_2/FIO_2$ was $108{\pm}41mmHg$, $137{\pm}57mmHg$, $158{\pm}50mmHg$, respectively(p=0.001). Age, sex, cause of ARDS, supine $PaO_2$ and $PaO_2/FIO_2$ were not different between the respiratory responders and the nonresponders. The respiratory responders, however, showed higher mean arterial pressure than the nonresponders($91.1{\pm}13.1mmHg$ vs. $76.0{\pm}18.7mmHg$, p=0.035), and tendency of higher survival rate(9/15 vs. 2/8, p=0.074). Static compliance of the respiratory system was decreased in prone position 0.5h($28.4{\pm}7.9ml/cm$ $H_2O$ vs. $23.8{\pm}7.6ml/cm$ $H_2O$, p=0.007). The overall rate of early response(n=23) and late response(n=11) were similar(14/23 vs. 7/11, p>0.05). But patient without early response showed late response only in 25%(1/4), while patient with early response showed late response in 85.7%(6/7)(p=0.072). Five patients(22%) showed positive hemodynamic response, two of them being respiratory nonresponders. There were no differences in the baseline mean arterial pressure or the level of PEEP applied in supine between the hemodynamic responders and the hemodynamic nonresponders. Conclusions : Prone position either improved oxygenation or increased arterial pressure in significant proportion of patients with ARDS. And the respiratory response to prone position was thought to be determined in the early stage of ARDS.

  • PDF

The Comparative Study of on Pump CABG during Pulsatile $(T-PLS^{TM})$ and Nonpulsatile $(Bio-pump^{TM})$ Perfusion (관상동맥우회술 시 사용된 박동성펌프$(T-PLS^{TM})$와 비박동성펌프$(Bio-pump^{TM})$의 비교연구)

  • Park Young-Woo;Her Keun;Lim Jae-Ung;Shin Hwa-Kyun;Won Yong-Soon
    • Journal of Chest Surgery
    • /
    • v.39 no.5 s.262
    • /
    • pp.354-358
    • /
    • 2006
  • Background: Pulsatile pumps for extracorporeal circulation have been known to be better for tissue perfusion than non-pulsatile pumps but be detrimental to blood corpuscles. This study is intended to examine the risks and benefits of $T-PLS^{TM}$ through the comparison of clinical effects of $T-PLS^{TM}$ (pulsatile pump) and $Bio-pump^{TM}$ (non-pulsatile pump) used for coronary bypass surgery. Material and Method: The comparison was made on 40 patients who had coronary bypass using $T-PLS^{TM}\;and\;Bio-pump^{TM}$ (20 patients for each) from April 2003 to June 2005. All of the surgeries were operated on pump beating coronary artery bypass graft using cardiopulmonary extra-corporeal circulation. Risk factors before surgery and the condition during surgery and the results were compared. Result: There was no significant difference in age, gender ratio, and risk factors before surgery such as history of diabetes, hypertension, smoking, obstructive pulmonary disease, coronary infarction, and renal failure between the two groups. Surgery duration, hours of heart-lung machine operation, used shunt and grafted coronary branch were little different between the two groups. The two groups had a similar level of systolic arterial pressure, diastolic arterial pressure and mean arterial pressure, but pulse pressure was measured higher in the group with $T-PLS^{TM}\;(46{\pm}15\;mmHg\;in\;T-PLS^{TM}\;vs\;35{\pm}13\;mmHg\;in\;Bio-pump^{TM},\;p<0.05)$. The $T-PLS^{TM}$-operated patients tended to produce more urine volume during surgery, but the difference was not statistically significant $(9.7{\pm}3.9\;cc/min\;in\;T-PLS^{TM}\;vs\;8.9{\pm}3.6\;cc/min\;in\;Bio-pump^{TM},\;p=0.20)$. There was no significant difference in mean duration of respirator usage and 24-hour blood loss after surgery between the two groups. Plasma free Hb was measured lower in the group with $T-PLS^{TM}\;(24.5{\pm}21.7\;mg/dL\;in\;T-PLS^{TM}\;versus\;46.8{\pm}23.0mg/dL\;in\;Bio-pump^{TM},\;p<0.05)$. There was no significant difference in coronary infarction, arrhythmia, renal failure and morbidity rate of cerebrovascular disease. There was a case of death after surgery (death rate of 5%) in the group tested with $T-PLS^{TM}$, but the death rate was not statistically significant. Conclusion: Coronary bypass was operated with $T-PLS^{TM}$ (Pulsatile flow pump) using a heart-lung machine. There was no unexpected event caused by mechanical error during surgery, and the clinical process of the surgery was the same as the surgery for which $Bio-pump^{TM}$ was used. In addition, $T-PLS^{TM}$ used surgery was found to be less detrimental to blood corpuscles than the pulsatile flow has been known to be. Authors of this study could confirm the safety of $T-PLS^{TM}$.

The National Survey of Acute Respiratory Distress Syndrome in Korea (급성호흡곤란증후군의 전국 실태조사 보고)

  • Scientific Subcommittee for National Survey of Acute Respiratory Distress Syndrome in Korean Academy of Tuberculosis and Respiratory Disease
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.1
    • /
    • pp.25-43
    • /
    • 1997
  • Introduction : The outcome and incidence of acute respiratory distress syndrome (ARDS) could be variable related to the varied definitions used for ARDS by researchers. The purpose of the national survey was to define the risk factors of ARDS and investigate the prognostic indicies related to mortality of ARDS in Korea according to the definition of ARDS determined by the American-European Concensus Conference on 1992 year. Methods : A Multicenter registry of 48 University or University-affliated hospital and 18 general hospital s equipped with more than 400 patient's beds conducted over 13 months of patients with acute respiratory distress syndrome using the same registry protocol. Results : 1. In the 12 months of the registry, 167 patients were enrolled at the 24 hospitals. 2. The mean age was 56.5 years (${\pm}17.2$ years) and there was a 1.9:1 ratio of males to females. 3. Sepsis was the most common risk factors (78.1%), followed by aspiration (16.6%), trauma (11.6%), and shock (8.5%). 4 The overall mortality rate was 71.9%. The mean duration was 11 days (${\pm}13.1$ days) from the diagnosis of ARDS to the death. Respiratory insufficiency appeared to be a major cause in 43.7% of the deaths followed by sepsis (36.1%), heart failure (7.6%) and hepatic failure (6.7%). 5. There were no significant differences in mortality based on sex or age. No significant difference in mortality in infectious versus noninfectious causes of ARDS was found. 6. There were significant differences in the pulse rate, platelet numbers, serum albumin and glucose levels, the amounts of 24 hour urine, arterial pH, $Pa0_2$, $PaCO_2$, $Sa0_2$, alveolar-arterial oxygen differences, $PaO_2/FIO_2$, and PEEP/$FI0_2$ between the survivors and the deaths on study days 1 through 6 of the first week after enrollment. 7. The survivors had significantly less organ failure and lower APACHE III scores at the time of diagnosis of ARDS (P<0.05). 8. The numbers of organ failure (odd ratio 1.95, 95% confidence intervals:1.05-3.61, P=0.03) and the score of APACHE III (odd ratio 1.59, 95% confidence interval:1.01-2.50, P=0.04) appeared to be independent risk factors of the mortality in the patients with ARDS. Conclusions : The mortality was 71.9% of total 167 patients in this investigation using the definition of American-European Consensus Conference on 1992 year, and the respiratory insufficiency was the leading cause of the death. In addition, the numbers of organ failure and the score of APACHE III at the time of diagnosis of ARDS appeared to be independent risk factors of the mortality in the patients with ARDS.

  • PDF

The Survey of Dentists: Updated Knowledge about Basic Life support and Experiences of Dental Emergency in Korea

  • Cho, Kyoung-Ah;Kim, Hyuk;Lee, Brian Seonghwa;Kwon, Woon-Yong;Kim, Mi-Seon;Seo, Kwang-Suk;Kim, Hyun-Jeong
    • Journal of The Korean Dental Society of Anesthesiology
    • /
    • v.14 no.1
    • /
    • pp.17-27
    • /
    • 2014
  • Background: Various medical emergency situations can occur during dental practices. Cardiac arrest is known to comprise approximately 1% of emergency situation. Thus, it is necessary for dentists to be able to perform cardiopulmonary resuscitation (CPR) to increase the chance of saving patient's life in emergency situation. In this paper, we conducted a survey study to evaluate to what extent dentists actually understood CPR practice and if they had experience in handling emergency situations in practice. Method: The survey was done for members of the Korean Dental Society of Anesthesiology (KDSA), who had great interest in CPR and for whom survey-by-mail was convenient. We had selected 472 members of the KDSA with a dental license and whose office address and contact information were appropriate, and sent them a survey questionnaire by mail asking about the degree of their CPR understanding and if they had experience of handling emergency questions before. Statistical analyses -frequency analysis, chi-square test, ANOVA, and so on- were performed by use of IBM SPSS Statistics 19 for each question. Result: Among 472 people, 181 responded (38.4% response rate). Among the respondents were 134 male and 47 female dentists. Their average age was $40.4{\pm}8.4$. In terms of practice type, there were 123 private practitioners (68.0%), 20 professors (11.0%), 16 dentists-in-service (8.8%), 13 residents (specialist training) (7.2%) and 9 military doctors (5%). There were 125 dentists (69.1%) who were specialists or receiving training to be specialist, most of whom were oral surgeon (57, 31.5%) and pediatric dentists (56, 30.9%). There were 153 people (85.0%) who received CPR training before, and 65 of them (35.9%) were receiving regular training. When asked about the ratio of chest pressure vs mouth-to-mouth respiration when conducting CPR, 107 people (59.1%) answered 30:2. However, only 27.1% of them answered correctly for a question regarding CPR stages, C(Circulation)- A(Airway)- B(Breathing)- D(Defibrillation), which was defined in revised 2010 CPR practice guideline. Dentists who had experience of handling emergency situations in their practice were 119 (65.6%). The kinds of emergency situations they experienced were syncope (68, 37.6%), allergic reactions to local anesthetic (44, 24.3%), hyperventilation (43, 23.8%), seizure (25, 13.8%), hypoglycemia (15, 8.3%), breathing difficulty (14, 7.8%), cardiac arrest (11, 6.1%), airway obstruction (6, 3.3%), intake of foreign material and angina pectoris (4, 2.2%), in order of frequency. Most respondents answered that they handled the situation appropriately under the given emergency situation. In terms of emergency equipment they had blood pressure device (70.2%), pulse oximetry (69.6%), Bag-Valve-Mask (56.9%), emergency medicine (41.4%), intubation kit (29.8%), automated external defibrillator (23.2%), suction kit (19.3%) and 12 people (6.6%) did not have any equipment. In terms of confidence in handling emergency situation, with 1-10 point scale, their response was $4.86{\pm}2.41$ points. The average point of those who received regular training was $5.92{\pm}2.20$, while those who did not was $4.29{\pm}2.29$ points (P<0.001) Conclusion: The result showed they had good knowledge of CPR but the information they had was not up-to-date. Also, they were frequently exposed to the risk of emergency situation during their dental practice but the level of confidence in handling the emergency situation was intermediate. Therefore, regular training of CPR to prepare them for handling emergency situation is deemed necessary.

Long-term oxygen therapy in patients with chronic respiratory failure in one university hospital (호흡부전환자의 재택산소치료 실태: 한 대학병원에서의 관찰)

  • Huh, Jin Won;Lee, Jung Yeon;Hong, Sang-Bum;Oh, Yeon Mok;Shim, Tae Sun;Lim, Chae-Man;Lee, Sang Do;Kim, Woo Sung;Kim, Dong Soon;Kim, Won Dong;Koh, Younsuck
    • Tuberculosis and Respiratory Diseases
    • /
    • v.58 no.2
    • /
    • pp.160-166
    • /
    • 2005
  • Background : Although home oxygen therapy in hypoxemic patients with chronic lung disease has been increasing over the decade in Korea, the present state has not been known well. This study was done to know the situation of home oxygen therapy in a Korean university hospital. Methods : Between January 1, 2000 and August 31, 2003, 86 patients prescribed home oxygen therapy by the pulmonary physicians of Asan Medical Center were investigated using their medical record and questionnaire. Results : Patients (52 men, mean age of 61 years) with home oxygen therapy were increasing by every year. Underlying diseases were COPD (n=29), tuberculous destroyed lung (n=18), bronchiectasis (n=15), ILD (n=12), and others. Baseline $FEV_1/FVC$, FVC, and $FEV_1$ of patients were $58.4{\pm}25.2%$, $54.5{\pm}17.1%$ of predicted, and $41.7{\pm}20.6%$ of pred. Mean oxygen flow was 1.5 L/min and mean duration per day was 14.5 hours. During therapy, mean $PaO_2$ values have increased from 51.2 to 77.7 mm Hg and $PaCO_2$ values have increased from 47.5 to 49.6 mm Hg. Only 16.5% of the subjects were monitored by visiting nurses or pulse oximeter. Three year survival rate was 56.6% and hypercapnic patients showed better prognosis. Conclusion : The patients with home oxygen therapy were increasing yearly and a part of them were monitored. The hypercapnea respiratory failure patients would have better prognosis.