• Title/Summary/Keyword: Pulse Rate

Search Result 1,687, Processing Time 0.027 seconds

Exploring the Accuracy and Methods of Estimation on Base Physical Quantities (기본물리량 어림의 정확성 및 방법에 대한 탐색)

  • Song, Jin-Woong;Kim, Hae-Sun
    • Journal of The Korean Association For Science Education
    • /
    • v.21 no.1
    • /
    • pp.76-88
    • /
    • 2001
  • This study explored people's accuracy and methods of estimating some base physical quantities, i.e. length, mass, time and temperature. A total of 40 members, ranging from freshmen to professors, of a physics education department of a local university were asked to make two different kinds of estimations, intuitive and operational, on two sets of objects. For intuitive estimation, they were asked to make estimations on four given objects (length - wood chopsticks, mass - rubber eraser, time electric fan, temperature - water in a cup) as soon as they faced with the objects, usually within a few seconds of seeing. For operational estimation, they were allowed to make estimations on a different set of objects (length - plastic rod, mass - lock, time - simple pendulum, temperature - water in a cup) with enough time and they could apply various available methods (e.g. using pencil to estimate the object's length, counting their own pulse rate to estimate time) for the estimation. The findings of this study can be summarized as follows: (1) for length, mass and temperature the intuitive estimations were better performed while for the time estimation the result was the reverse; (2) there was no positive relationship between the amount of physics experience and the accuracy of the estimation; (3) in general, people's accuracy of the length estimation was best performed while their mass estimation was worst performed; (4) people used their own various methods for estimation, esp. using nearby objects around them and applying mental units which have convenient values (e.g. 30cm, 50cm, 1kg, 1 Keun, 1 second).

  • PDF

Effects of feeding different varieties of faba bean (Vicia faba L.) straws with concentrate supplement on feed intake, digestibility, body weight gain and carcass characteristics of Arsi-Bale sheep

  • Wegi, Teklu;Tolera, Adugna;Wamatu, Jane;Animut, Getachew;Rischkowsky, Barbara
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.31 no.8
    • /
    • pp.1221-1229
    • /
    • 2018
  • Objective: A study was conducted to evaluate the varietal differences among faba bean straws and also to assess the potentials of faba bean straws supplemented with concentrate fed at the rate 70% straws and 30% concentrate mixture on feed intake, digestibility, body weight gain and carcass characteristics of the animals. Methods: Forty yearling Arsi-Bale sheep with initial body weight of $19.85{\pm}0.29kg$ (mean${\pm}$standard deviation) were grouped in a randomized complete block design into eight blocks of five animals each based on their initial body weight. Straws included in the study were from Mosisa (T1M), Walki (T2W), Degaga (T3D), Shallo (T4S), and local (T5L) varieties of faba bean and concentrate (2:1 ratio of wheat bran to "noug" seed cake). The experiment consisted of seven days of digestibility and 90 days of feeding trials followed by evaluation of carcass parameters at the end. Results: Local variety had lower (p<0.05) in grain and straw yield compared to improved varieties but higher in crude protein, metabolizable energy contents and in vitro organic matter digestibility. The apparent digestibility of dry matter and crude protein of sheep fed Walki and Mosisa straws were higher than (p<0.05) straws from Shallo varieties. Sheep fed Walki straw had greater (p<0.05) dry matter intake, average daily gain and feed conversion efficiency than sheep fed local and Shallo straws. Slaughter body weight and empty body weight were higher (p<0.05) for sheep fed Mosisa and Walki straws as compared to sheep fed Shallo straws. Apart from this, the other carcass components were not affected (p>0.05) by variety of the faba bean straws. Conclusion: There is significant varietal differences between faba bean straws both in quality and quantity. Similarly, significant variation was observed in feed intake, digestibility, body weight gain and feed conversion efficiency among sheep fed different straws of faba bean varieties with concentrate supplement. Based on these results, Walki and Mosisa varieties could be recommended as pulse crop rotation with cereals in the study area.

Fabrication of Porous Alumina Ceramics by Spark Plasma Sintering (방전 플라즈마 소결법에 의한 다공성 알루미나 세라믹스의 제조)

  • Shin, Hyun-Cheol;Cho, Won-Seung;Shin, Seung-Yong;Kim, Jun-Gyu
    • Journal of the Korean Ceramic Society
    • /
    • v.39 no.12
    • /
    • pp.1183-1189
    • /
    • 2002
  • In order to develope the porous alumina ceramics with high strength, the pore characteristics and compressive strength were investigated in terms of relation to the conditions of spark-plasma sintering and the contents of graphite as a pore precursor. Porous alumina bodies were successfully prepared by spark-plasma sintering and burning out graphite in air. High porous bodies were fabricated by sintering at 1000${\circ}C$ for 3 min under a pressure of 30 MPa, heating rate of 80${\circ}C$/min and on-off pulse type of 12:2. For example, alumina bodies prepared by the addition of 10∼30 vol% graphite showed high porosity of 50∼57%. Also, the open porosity increased with graphite content. The relationship between pore characteristics and graphite contents could be explained by percolation model depending on cluster number and size. Porous alumina bodies prepared by the addition of 10∼30 vol% graphite showed the high compressive strength of 55∼200 MPa. This great improvement in strength was considered to be mainly due to the spark-plasma discharges and the self-heating action between particles.

Absorption Spectra of Standard Gases for Wavelength Reference in C-band using a Supercontinuum Source Based on a Mode-locked Cr4+:YAG Laser (모드 잠금 Cr4+:YAG 레이저로부터 발생된 초 광대역 광원을 이용한 광통신 파장 영역의 표준 가스의 흡수스펙트럼)

  • Lee, Jong-Min;Jeon, Min-Yong;Ryu, Han-Young;Suh, Ho-Suhng
    • Korean Journal of Optics and Photonics
    • /
    • v.19 no.1
    • /
    • pp.54-59
    • /
    • 2008
  • We report on the measurements of absorption spectra from acetylene ($^{12}C_2H_2$) and hydrogen cyanide ($H^{13}C^{14}N$) for wavelength reference in the C-band (conventional band) region using a supercontinuum optical source generated from a mode-locked $Cr^{4+}$:YAG laser. The center wavelength of the mode-locked $Cr^{4+}$:YAG laser was 1510 nm and the pulse duration was 75 fs at 100 MHz repetition rate. The supercontinuum source achieved a flatness of ${\pm}5dB$ over a wavelength range of more than 400 nm, using a 20 m long photonic crystal fiber. The measured absorption spectra from acetylene ($^{12}C_2H_2$) and hydrogen cyanide ($H^{13}C^{14}N$) had more than 50 lines and were analyzed for wavelength standardization.

Generation of Femtosecond Pulses in a Passively Mode-Locked 100 MHz Cr4+:YAG Laser (수동 모드 잠금된 100 MHz Cr4+:YAG 레이저에서의 펨토초 펄스 발생)

  • Cho, Won-Bae;Rotermund Fabian;Kim, Jong-Doo;Jeon, Min-Yong;Suh, Ho-Suhng
    • Korean Journal of Optics and Photonics
    • /
    • v.16 no.6
    • /
    • pp.535-541
    • /
    • 2005
  • We report on the development of a passively mode-locked near-infrared femtosecond laser with Cr:YAG crystal that operates near room temperature. The laser wavelength could easily be tuned by using only the internal prism pair over 110 nm from 1400 nm to 1510 nm in cw and over about 30 nm in mode-locked operation, respectively Maximum cw output powers of 810 mW were obtained with $1.5 \%$ output coupler for absorbed pump powers of 7.6 W. For compensation of the internal group velocity dispersion, an IR graded prism pair was used. The Cr:YAG laser delivered nearly Fourier-transform limited pulses with a pulse duration as short as 64 fs at 100 MHz repetition rate. In the mode-locked regime, the laser was operating at 1510 nm with a spectral bandwidth of 44 nm. In order to avoid unstable mode-locking and power instabilities, self-built tubes were inserted into the beam path in the resonator and purged with N2 gas. Finally, output powers of the Cr:YAG laser were optimized to 250 mW fer long time stable mode-locked operation.

Effect of Gastrodia Elata BL Water Extract on Human Cerebral Blood Flow using Transcranial Doppler (천마추출물이 정상인의 뇌혈류에 미치는 영향)

  • Moon Sang-Kwan;Kim Young-Suk;Park Seong-Uk;Jung Woo-Sang;Ko Chang-Nam;Cho Ki-Ho;Bae Hyung-Sup
    • The Journal of Korean Medicine
    • /
    • v.26 no.1 s.61
    • /
    • pp.115-122
    • /
    • 2005
  • Background and objective: Gastrodiae Rhizoma (GR), the rhizoma of Gastrodia elata BL., is one of the popular drugs to treat headache, dizziness, blackout, numbness of limbs, hemiplegia, facial paralysis, dysphrasia, and infantile convulsions. It has been reported that it provides an antihypertensive effect and lowers cerebrovascular resistance in animal experiments. However, there has been no data about these effects with human subjects. In this study, the author examined the effect of Gastrodiae water extracts on blood pressure and cerebrovascular reactivity in human subjects. Methods: We selected 16 normal volunteers, who were divided into 2 groups: Gastrodiae extract administration group and placebo (creamy powder) group. Using transcranial Doppler ultrasound, we monitored changes of mean flow velocity and breath-holding induced CO2 reactivity of middle cerebral artery in both groups. Mean blood pressure, heart rate and PETCO2 were measured using Compact Anesthesia Monitor. In both groups, all evaluation was performed during basal condition, and repeated at 30, 60, and 90 min after administration. Results: Gastrodiae extract decreased CO2 reactivity after administration, reaching the lowest level at 90 minutes $(-29.1\%\;vs.\;basal\;level)$, which showed significant difference compared with the placebo group (p = 0.004). In the placebo group, the pulse rates tended to decrease over time (at 90 minute, $-5.2\%$ vs. basal level) while in the Gastrodiae group the values showed nearly no change, which showed significant difference between both groups (p = 0.036). However, the changes of mean blood pressure and mean flow velocity did not show significant difference between both groups. Conclusion : This study demonstrated that Gastrodiae extract significantly decreased breath-holding induced CO2 reactivity. This result suggests that the clinical effect of Gastrodiae extract might be caused by increasing cerebral blood flow via dilation of cerebral resistant vessels instead of antihypertensive effect.

  • PDF

Clinical Efficacy of Transdermal Clonidine (St 155 BS) for Anesthetic Management in Hypertensive Patients (고혈압 환자 마취시 Transdermal Clonidine (St 155 BS)의 임상적 유용성)

  • Lee, Hyun-Hwa;Kim, Dong-Ok;Kim, Keon-Sik;Choi, Young-Kyoo;Shin, Ok-Young;Kwon, Moo-Il;Lee, Doo-Ik
    • The Korean Journal of Pain
    • /
    • v.6 no.2
    • /
    • pp.231-236
    • /
    • 1993
  • Clonidine, a centrally-acting antihypertensive agent known to reduce central sympathetic outflow and modulate presynaptic transmitter's release, has shown to suppress central noradrenergic hyperactivity induced by immobilization stress in animals, by decreasing the MAC of halothane and the dose of narcotics required to prevent reflex cardiovascular response to noxious stimuli, and to have potent analgesic properties in humans. These characteristics suggest that clonidine might be a useful adjunct to the anesthetic management of patients with preexisting hypertension. Accordingly, we determined the clinical efficacy and safety on analgesia, sedation and hemodynamic stability in the perioperative period. Thirty patients(ASA physical status II-III) with a history of arterial hypertension, scheduled for elective orthopedic surgery were randomly assigned to two groups. We applied CPA-clonidine patch($6.9\;mg/cm^2$, 0.2 mg delivered daily) or placebo patch to each groups, 48 hours prior to induction of anesthesia. Antihypertensive medication was continued until the morning of the scheduled surgery. All patients received premedication of atropine and lorazepam, and induced anesthesia with thiopental and succinylcholine, and maintained with enflurane and 50% nitrous oxide, while sustaining the BP and pulse rate at acceptable range. For the relief of pain postoperatively, diclofenac and fentanyl were administered intramuscularly on demand. The results were as follows: 1) The change of hemodynamic responses in clonidine group was less compared to the placebo group. 2) Intraoperative anesthetic requirement for enflurane in clonidine group were significantly lower than placebo group. 3) Postoperative analgetic requirement in clonidine group were significantly lower than placebo group. In clonidine group, 5 cases out of 15 cases were required no analgetics, and the incidence of administration of additional fentanyl was decreased to 5 cases, comparing with 10 cases in placebo group.

  • PDF

Reduction of Chattering Error of Reed Switch Sensor for Remote Measurement of Water Flow Meter (리드 스위치 센서를 이용한 원격 검침용 상수도 계량기에서 채터링 오차 감소 방안 연구)

  • Ayurzana, Odgerel;Kim, Hie-Sik
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.44 no.4 s.316
    • /
    • pp.42-47
    • /
    • 2007
  • To reduce the chattering errors of reed switch sensors in the automatic remote measurement of water meter a reed switch sensor was analyzed and improved. The operation of reed switch sensors can be described as a mechanical contact switch by approximation of permanent magnet piece to generate an electrical pulse. The reed switch sensors are used mostly in measurement application to detect the rotational or translational displacement. To apply for water flow measurement devices, the reed switch sensors should keep high reliability. They are applied for the electronic digital type of water flow meters. The reed switch sensor is just mounted simply on the conventional mechanical type flow meter. A small magnet is attached on a pointer of the water meter counter rotor. Inside the reed sensor two steel leaf springs make mechanical contact and apart repeatedly as rotation of flow meter counter. The counting electrical contact pulses can be converted as the water flow amount. The MCU sends the digital flow rate data to the server using the wireless communication network. But the digital data is occurred difference or won by chattering noise. The reed switch sensor contains chattering error by it self at the force equivalent position. The vibrations such as passing vehicle near to the switch sensor installed location causes chattering. In order to reduce chattering error, most system uses just software methods, for example using filter algorithm and also statistical calibration methods. The chattering errors were reduced by changing leaf spring structure using mechanical characteristics.

The Design of Feature Selection Classifier based on Physiological Signal for Emotion Detection (감성판별을 위한 생체신호기반 특징선택 분류기 설계)

  • Lee, JeeEun;Yoo, Sun K.
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.11
    • /
    • pp.206-216
    • /
    • 2013
  • The emotion plays a critical role in human's daily life including learning, action, decision and communication. In this paper, emotion discrimination classifier is designed to reduce system complexity through reduced selection of dominant features from biosignals. The photoplethysmography(PPG), skin temperature, skin conductance, fontal and parietal electroencephalography(EEG) signals were measured during 4 types of movie watching associated with the induction of neutral, sad, fear joy emotions. The genetic algorithm with support vector machine(SVM) based fitness function was designed to determine dominant features among 24 parameters extracted from measured biosignals. It shows maximum classification accuracy of 96.4%, which is 17% higher than that of SVM alone. The minimum error features selected are the mean and NN50 of heart rate variability from PPG signal, the mean of PPG induced pulse transit time, the mean of skin resistance, and ${\delta}$ and ${\beta}$ frequency band powers of parietal EEG. The combination of parietal EEG, PPG, and skin resistance is recommendable in high accuracy instrumentation, while the combinational use of PPG and skin conductance(79% accuracy) is affordable in simplified instrumentation.

The Efficacy and Safety of Moclobemide Twice Daily : An Open Trial in Patients with Major Depressive Disorder (1회 2회 분복 투여하는 Moclobemide의 효과와 안전성 : 주요우울장애 환자에서 개방 시험)

  • Yoon, Jin-Sang;Lee, Hyung-Young;Kook, Seung-Hee;Choi, Young
    • Korean Journal of Biological Psychiatry
    • /
    • v.3 no.1
    • /
    • pp.102-108
    • /
    • 1996
  • This was an open trial to evaluate the efficacy and safety of moclobemide twice daily for treatment of Korean patients with major depressive disorder(DSM-III-R). The duration of the trial was 6 weeks with the initial dose of moclobemide being fixed lor the first two weeks at 300mg/day(150mg twice daily, each token after morning and evening meals). Thereafter, when necessary, the dose was allowed to increase to 600mg/day or decrease to 150mg/day according to the seventy of the depression and/or the tolerability of the drug. Hypnotics and/or sedatives from a benzodiazepine group could be concomitantly administered at usual dosage. Patients were assessed at baseline and at days 14, 28 and 42. Efficacy was primarily judged on the Hamilton Rating Scale for Depression(HAM-D) and Beck Depression Inventory(BDI). Patients had to score at least 17 respectively an both scales to enter the trial. Secondary efficacy parameters included Clinical Global Impression(CGI) for severity of illness and improvement. Safety and tolerability were judged on reported adverse events, vital signs and laboratory parameters. In addition, there was a series of questions and assessments for the psychiatrists and patients to complete at the end of the trial Twenty nine patients completing trial were included in the analysis of efficacy : of thirty one patients participating in the safety and tolerability analysis, those who withdraw voluntarily without particular reasons or violated the treatment schedule were not included. The efficacies as determined by HAM-D, BDI or CGI were found to be significant compared to baseline. The number of responders defined as patients with a total score of 10 or less or with a total score of 50% or less of the baseline score on HAM-D and BDI were 17(59%) and 18(62%) respectively. Regarding safety and tolerability, nine patients(29%) reported mild adverse events probably related to moclobemide : of these one patient dropped out because of poor tolerability : however, there were no appreciable changes in blood pressure, pulse rate, body weight or laboratory parameters for all patients over the trial period. Furthermore, the physicians' and patients' opinions at final evaluation showed that moclabemide has a good antidepressant effect as well as a favorable tolerability. In conclusion, a twice-daily dosage schedule with maclobemide is recommendable for the treatment of Korean patients with major depressive disorder since its efficacy and safety were demonstrated in this study.

  • PDF