• Title/Summary/Keyword: Pulse Point

Search Result 512, Processing Time 0.027 seconds

A Study on Performance Enhancement of Period Detection in Pulse Wave (맥파의 주기 검출 성능 개선에 관한 연구)

  • Lee, Hyun-Min;Kim, Dong-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.6
    • /
    • pp.1194-1199
    • /
    • 2009
  • Heart rate may be a very important parameter in human health. To extract heart rate, the electrocardiogram(ECG) is commonly used. But the ECG acquisition procedure is very complex. On the other hand, the acquisition of pulse wave or photoplethysmogram(PPG) is very easy. However, the peak of PPG is not so sharp as ECG. This study tries to enhance the performance of peak detection in PPG signal. The method uses the average slopes around the main peak. The crossing point of the increasing and the decreasing slopes is selected as the peak point of heart rate period. The proposed method showed smoothed heart rate graph and reduced irregularity in heart rate values.

Flicker Prevention Through Edge-Pulse Modulation in a Visible Light Identification System (가시광 무선인식장치에서 가장자리 펄스변조를 이용한 플리커 방지)

  • Lee, Seong-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.29 no.3
    • /
    • pp.180-186
    • /
    • 2020
  • In this study, we applied edge-pulse modulation to prevent the flicker of light-emitting diode (LED) light in a visible light identification system. In the visible light transmitter, positive pulses were transmitted at the edges of the low-to-high transition points, and negative pulses were transmitted at the edges of the high-to-low transition points of the non-return-to-zero (NRZ) data waveforms. In the visible light receiver, the NRZ waveforms were regenerated by making low-to-high and high-to-low transitions at the point of the positive and negative pulses, respectively. This method has two advantages. First, it ensures that the LED light is flicker-free because the average optical power of the LED was kept constant during data transmission in the transmitter. Second, the 120 Hz optical noise from the adjacent lighting lamps was easily cut off using a simple RC-high pass filter in the receiver.

Estimation of the Central Aortic Pulse using Transfer Function and Improvement of an Augmentation Point Detection Algorithm (전달함수를 이용한 대동맥 맥파 추정 및 증강점 검출 알고리즘 개선에 관한 연구)

  • Im, Jae-Joong
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.45 no.3
    • /
    • pp.68-79
    • /
    • 2008
  • Aortic AIx(augmentation index) has been used to measure aortic stiffness quantitatively and even to evaluate ventricular load. However, in order to calculate aortic AIx catheters should be inserted to the subjects' artery, which hampers its clinical usage. To overcome such limitation, aortic AIx has been indirectly calculated by estimating aortic pressure wave from the peripheral arterial pulse by applying transfer functions. In this study, central aortic pressure waves using Millar catheter and radial artery pulse waves using tonometry pressure sensor were measured to establish transfer functions for an estimation of central aortic pressure waves from radial artery pulse waves. Also, an algorithm which detects augmentation point for the calculation of AIx were developed. Developed algorithm for the detection of augmentation point gradually increases the differential order to detect inflection point rather than detects the distinctive point that appears after a specific time. Transfer functions were established using 10th order ARX model and were verified for the stability of the transfer function through residual analysis. Evaluation of an algorithm for the detection of augmentation point were performed by comparing the augmentation points obtained from developed algorithm with the known augmentation points synthesized in various conditions. In addition, developed algorithm for the AIx is proved to provide more accurate results than the ones developed by previous studies. The significance of the study was in two folds. Firstly, the results could provide the basis for the measurement of aortic stiffness using easily-measurable radial artery pulse waves, and secondly, extension of the study may enable the early diagnosis of various vascular diseases.

A Study on the Correlation between Pulse Energy and Sasang Constitutional Syndromes (맥 Energy와 사상체질병증의 연계 연구)

  • Kim, Dal-Rae;Kim, Sun-Hyung
    • The Journal of Korean Medicine
    • /
    • v.30 no.1
    • /
    • pp.26-39
    • /
    • 2009
  • Objectives: Pulse energy values recorded with an add-pres sure-type pulse apparatus were correlated with Sasang constitutional syndromes in order to match pulse energy values with Sasang prescriptions. Methods: The pulse energy values were measured with Daeyo Pulse Apparatus at the Gwan pulse point of both wrists. Prescriptions were divided into two major categories of interior syndromes or exterior syndromes, and categorized according to major component herbs specific to each of the four Sasang constitutions, and the relationship between the pulse energy and each groups divided by their prescription was studied. Results: About 10% of all people had nonmal pulse energy values. 10% had values over normal range, and $70\sim80%$ had lower values than normal. The normal range of pulse energy was regarded as being between 450 and 700. Conclusions: 1. For patients of the Soeum constitution, prescriptions without Panax ginseng is suitable for patients with high pulse energy, and prescriptions containing Panax ginseng are suitable for patients who have lower pulse energy. 2. All prescriptions for the Soyang constitution containing Rehmannia radix preparata or Comus officinalis are suitable for patients who have lower pulse energy, and prescriptions containing Rehmannia radix or Gypsum fibrosum are applicable to patients with pulse energy values higher than normal. 3. Most prescriptions for the Taeum constitution containing Semen coicis or Semen castaneae are suitable for patients with lower pulse energy, and prescriptions containing Radix puerariae or Radix et rhizoma rhei can be prescribed for patients who have lower pulse energy levels. 4. The Taeyang constitutional prescription Ogapijangcuck-tang is suitable for patients who have higher pulse energy levels and Mihudeungsikjang-tang is better for patients with lower than normal pulse values. As described above, the pulse energy level of each patient can be matched with a specific Sasang constitutional prescription. If this relationship is taken into consideration with other conventional symptoms, it can be helpful in diagnosis, improving efficacy of treatment, and be used as objective evidence.

  • PDF

Multi-Point Radial Artery Pulse Wave Transducer using Pneumatic System (공압 방식에 의한 다지점 요골 맥파 검출 장치)

  • 이종진;정민석;황성하;이종현;이선규
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2001.04a
    • /
    • pp.243-248
    • /
    • 2001
  • A radial artery pulse wave is well known as a good mans to diagnose human body condition in th field of Chinese medical science. Information about constitution as well as organs can be obtained by detecting the artery pulse wave. Recently, the information about the human body constitution may be utilized in accelerating the recovery process of the patient on the basis of comprehensive diagnosis. A radial artery pulse wave is considered as one of promising means in examining the human body constitution. Since the examination has been conducted by the feeling of finger, the diagnosis may occasionally have uncertainty or fatal error. In this paper, a new measuring system is suggested and developed to examine the pattern of a pulse wave correctly. The system is composed of four pressure vessels, pressure sensors and air supplying pumps. One of them is utilized for appropriately pressing the radial artery, three of them for detecting pressure change in several mmHg level. The detected data is shown and discussed.

  • PDF

A Study on the Auto-diagnosis Plethysmograph by Novel Algorithm for Radial Pulse Detection (새로운 맥파 인식 알고리즘을 적용한 자동 맥파 시스템에 관한 연구)

  • 박승환;홍승홍
    • Journal of Biomedical Engineering Research
    • /
    • v.17 no.2
    • /
    • pp.241-246
    • /
    • 1996
  • This paper describes a new system that detects radial pulse wave and allows the diagnosis of malfunctions of cardiovascular system by analyzing the waveforms with the newly proposed algorithm. The system consists of a sensor part and a data processing part within which a new detection algorithm is incorporated In acquiring radial pulse signal noninvasively, the sensor used in this system is a new combinational fiber-optic sensor which has a detecting Part and a transmitting Part. Also, In order to analyze the characteristics of pulsation quantitatively, the algorithm proposed in this paper is a method that runs in parallel with both the data of ECG and differential pulse simultaneously. these concepts are based upon the idea that thfee Q points of ECG give obious discrimination of one entire period of pulse in any abnormal cases, and newly defined feature lines at the differential counterpart can be used to recogrlize sDme significant points in one period of pulses.

  • PDF

A Study on the Significant Point Detection Algorithm and Design of Hardware for Pulse Automatic Diagnosis (맥파자동진단을 위한 하드웨어의 설계 및 특성점 검출 알고리즘에 관한 연구)

  • Lee, J.Y.;Lee, J.W.;Lee, M.H.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07g
    • /
    • pp.2255-2258
    • /
    • 1998
  • Method of diagnosis in oriental medicine, the unbalance of the physiological function of the five viscers and six bowels of the human body is determined from time immemorial with the condition of blood circulation which is performed through blood vessels by the vitality of the heart. In oriental medicine, treatment is largely attempted by adjusting this unbalance. The analysis of pulse wave, which mainly measures the changes in blood flows, is to evaluate the shapes of a pulse wave rather than the quantitative changes like rates and strength of the pulse. This paper presents the development of Hardware System and Pulse Diagnosis Algorithm for automatic diagnosis of the pulse wave. This system makes the precise diagnosis and the objective recording possible.

  • PDF

Measurement of Arterial Pulse Wave at the Temple Using PZT Piezo Sensor

  • Kil Se Kee;Han Young Hwan;Lee Eung Hyuk;Park Young Bae;Cho Heung Ho;Min Hong Ki;Hong Seung Hong
    • Proceedings of the IEEK Conference
    • /
    • 2004.08c
    • /
    • pp.772-775
    • /
    • 2004
  • Generally, arterial pulse waves are measured at the radial arterial of wrist or carotid arterial of neck using a sensor such as pressure sensor, piezoelectric sensor or optic sensor. But in this paper, arterial pulse wave is measured at the temple using PZT piezo sensor which is attached on the temple in form of a hair-band. Arterial Pulse waves are generally measured when a reagent is in a static state. But in this paper, we implemented the arterial pulse wave measurement system, as a previous stage of the arterial pulse wave measurement system for running at outdoors or on a running machine, that measures arterial pulse waves at the temple, which is the least moving part when running. Thorough the continuous study, if the motion artifact when running is possible to be removed, the system will be able to perform monitoring of running men's states and especially emergency signals such as serious pulse waves of an/old and feeble persons and handicapped persons.

  • PDF

Peak Detection of Pulse Wave Based on Fuzzy Inference and Multi Sub-Band Filters for U-Healthcare (U-헬스케어를 위한 퍼지추론과 다중 하위대역 필터를 기반한 맥파 최대치 검출)

  • Lee, Ju-Won;Lee, Byeong-Ro
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.12 no.12
    • /
    • pp.2159-2164
    • /
    • 2008
  • Ubiquitous healthcare system is system that monitors and manages user's health information, and most important in the healthcare system is accuracy of the measured health data. But, the accuracy changes remarkably according to user's motion artifacts in real life. To elevate accuracy of health data, we proposed new algorithm to detect maximum point of pulse wave for heart rate extraction. and the proposed algorithm is to detect maximum points detect of pulse wave in photo-plethysmography signal included motion artifacts by fuzzy inference and multi sub-band filters. In results of experiment to evaluate the performance of the proposed algorithm, we could verify the proposed algorithm extracted maximum point of pulse wave in complex motion artifacts.

Pulse-Width Modulation Strategy for Common Mode Voltage Elimination with Reduced Common Mode Voltage Spikes in Multilevel Inverters with Extension to Over-Modulation Mode

  • Pham, Khoa-Dang;Nguyen, Nho-Van
    • Journal of Power Electronics
    • /
    • v.19 no.3
    • /
    • pp.727-743
    • /
    • 2019
  • This paper presents a pulse-width modulation strategy to eliminate the common mode voltage (CMV) with reduced CMV spikes in multilevel inverters since a high CMV magnitude and its fast variations dv/dt result in bearing failure of motors, overvoltage at motor terminals, and electromagnetic interference (EMI). The proposed method only utilizes the zero CMV states in a space vector diagram and it is implemented by a carrier-based pulse-width modulation (CBPWM) method. This method is generalized for odd number levels of inverters including neutral-point-clamped (NPC) and cascaded H-bridge inverters. Then it is extended to the over-modulation mode. The over-modulation mode is implemented by using the two-limit trajectory principle to maintain linear control and to avoid look-up tables. Even though the CMV is eliminated, CMV spikes that can cause EMI and bearing current problems still exist due to the deadtime effect. As a result, the deadtime effect is analyzed. By taking the deadtime effect into consideration, the proposed method is capable of reducing CMV spikes. Simulation and experimental results verify the effectiveness of the proposed strategy.