• 제목/요약/키워드: Pulse Number

검색결과 720건 처리시간 0.024초

Stochastic 구조를 이용한 신경회로망의 구현 (VLSI implementation of neural network with stochastic architecture)

  • 정덕진;한상욱
    • 대한전기학회논문지
    • /
    • 제45권2호
    • /
    • pp.319-324
    • /
    • 1996
  • Using random pulse stream, a number can be transformed to the pulse stream with the probability value. So the digital value are computed by simple digital gates. Thus it will be possible to build a small and strong noise immunity processing element. We propose a faster convergence algorithm using a new methods for better performance of Random Number Generator(RNG) an the nonlinear transfer function(Sigmoid function)in this paper. And a feedback circuit were fitted for pulse stream in this paper. We proposed method is simulated with C program language and conformed by circuit implementation. Finally a system for hand written number recognition is constructed by FPGA and its performance verified.

  • PDF

과학로켓 탑재부 자세제어를 위한 펄스 진폭 변조 제어기 설계 (Design of Pulse Amplitude Modulation Controller for the Attitude Control of the Payload of a Sounding Rocket)

  • 공현철;전상운
    • 제어로봇시스템학회논문지
    • /
    • 제6권11호
    • /
    • pp.981-986
    • /
    • 2000
  • A pulse amplitude modulation(PAM) controller is designed for the 3 axis attitude control of a sounding rocket. a certain number of fixed level of thrust are used for the pulse amplitude modulation and the nonlinearity of the controller is considered to examine the existence of the limit cycles and the stability analysis is carried out with the aid of Nyquist plot.

  • PDF

Multiple consecutive-biphasic pulse stimulation improves spatially localized firing of retinal ganglion cells in the degenerate retina

  • Jungryul Ahn;Yongseok Yoo;Yong Sook Goo
    • The Korean Journal of Physiology and Pharmacology
    • /
    • 제27권6호
    • /
    • pp.541-553
    • /
    • 2023
  • Retinal prostheses have shown some clinical success in restoring vision in patients with retinitis pigmentosa. However, the post-implantation visual acuity does not exceed that of legal blindness. The reason for the poor visual acuity might be that (1) degenerate retinal ganglion cells (RGCs) are less responsive to electrical stimulation than normal RGCs, and (2) electrically-evoked RGC spikes show a more widespread not focal response. The single-biphasic pulse electrical stimulation, commonly used in artificial vision, has limitations in addressing these issues. In this study, we propose the benefit of multiple consecutive-biphasic pulse stimulation. We used C57BL/6J mice and C3H/HeJ (rd1) mice for the normal retina and retinal degeneration model. An 8 × 8 multi-electrode array was used to record electrically-evoked RGC spikes. We compared RGC responses when increasing the amplitude of a single biphasic pulse versus increasing the number of consecutive biphasic pulses at the same stimulus charge. Increasing the amplitude of a single biphasic pulse induced more RGC spike firing while the spatial resolution of RGC populations decreased. For multiple consecutive-biphasic pulse stimulation, RGC firing increased as the number of pulses increased, and the spatial resolution of RGC populations was well preserved even up to 5 pulses. Multiple consecutive-biphasic pulse stimulation using two or three pulses in degenerate retinas induced as much RGC spike firing as in normal retinas. These findings suggest that the newly proposed multiple consecutive-biphasic pulse stimulation can improve the visual acuity in prosthesis-implanted patients.

한의사 맥진 가압력 재현에 대한 고찰 (Considerations on an Oriental Medical Doctor like Indentation System)

  • 이전;우영재;전영주;이유정;유현희;김종열
    • 한국한의학연구원논문집
    • /
    • 제14권3호
    • /
    • pp.113-119
    • /
    • 2008
  • In pulse diagnosis, the indentation pressure is one of the most important factors as well as the change of pulse shape and the distribution of pressure via time. But, on the oriental medical doctor's indentation pressure control, the understandings of the neurophysiological meanings and mechanisms have been lacked. So, in this paper, we considered on these issues and then proposed a proper system which can imitate the OMD's indentation pressure control mechanisms. As a result, both tactile information and kinesthetic information were found to be essential to the indentation pressure control so that a system, which can measure both the physical indent pressure and the displacement of an indentation arm, has been proposed. With this proposed system, while the indentation was being controlled through the moving step number of the step motor, the physical indentation pres sure and displacement of the indentation arm were measured. From these measured data, the relationships between the moving step number and both physical indentation pressure and displacement were revealed to have linear characteristics in early phase and to have nonlinear characteristics in latter phase. Additionally, three types of graph were generated whose X axis means the moving step number, the physical indentation pressure and the displacement respectively and Y axis means the pulse pressure. By comparing these graphs, we come to conclude that different concepts on indentation pressure control cause different diagnostic results on floating/sinking degrees for the same subject. Consequently, an indentation system for the pulse diagnosis should be able to provide both the tactile information and kinesthetic information, that is, the physical indentation pressure and the displacement of the indentation arm. In future, the proposed system should be optimized to the pulse diagnosis environment and how to combine the both information for more reliable diagnosis should be studied.

  • PDF

반사 지점의 개수와 조건이 맥파에 미치는 영향 (Effect of Number and Condition of Reflection Site on Pulse Wave)

  • 이민우;장민;신상훈
    • 대한의용생체공학회:의공학회지
    • /
    • 제41권1호
    • /
    • pp.8-13
    • /
    • 2020
  • To develop cardiovascular simulator capable of implementing pulse waves similar to the human body, accurate information about reflection wave is required. However, the conclusion is still not clear and various discussions are underway. In this study, the pulse wave velocity of the tube used in the experiment was first determined by measuring the pressure waves at two points in a single tube system with the experimental device to implement the pulse wave transmission of blood vessels, and the superposition time and characteristics of the reflection wave were confirmed. After that, an air chamber was set at the reflection site, and the effect of the change of air volume on the reflection wave was investigated. Finally, the effect of the number of branches connected to a single tube on the reflection wave was investigated. The superposition time of the reflection wave can be controlled by the air volume of the air chamber, and the magnitude of the reflection wave is influenced by the number of reflection sites that generate the reflection wave. The results of this study may be of practical assistance to simulator researchers who want to implement pulse wave similar to clinical data. It is expected that the more results similar to clinical are provided, the greater the scope of the simulator's contribution to clinical cardiovascular research.

맥 센서 어레이(array)의 실리콘(silicone) 코팅 두께에 따른 센서 간 간섭효과 (Interference Effects on the Thickness of a Pulse Pressure Sensor Array Coated with Silicone)

  • 전민호;전영주;김영민
    • 센서학회지
    • /
    • 제25권1호
    • /
    • pp.35-40
    • /
    • 2016
  • Pulse diagnosis is one of the representative diagnostic methods in Oriental medicine. In this study, a pulse pressure sensor array coated with silicone, which includes 6 piezo-resistive sensors and 1 thermistor, is fabricated for pulse measurement. It is necessary to coat the pulse sensor array with silicone to avoid the fracture or damage of pressure sensors when the sensor is in contact with the skin and a constant pressure is applied. However, the silicone coating on the pulse sensor array can cause signal interference among the sensors in the pulse sensor array. The interference number (IN), a calculation for expressing the degree of interference among channels, is changed according to the silicone thickness on the pulse sensor array. The IN is increased by a thick silicone coating, but the fabrication error, an important index for the mass production of the sensor array, is reduced by the thickness of the silicone coating. We propose that the thickness of the silicone on the pulse sensor array is an important consideration for the performance of the fabricated sensor and manufacturing repeatability.

Performance Evaluation of Various Bus Clamped Space Vector Pulse Width Modulation Techniques

  • Nair, Meenu D.;Biswas, Jayanta;Vivek, G.;Barai, Mukti
    • Journal of Power Electronics
    • /
    • 제17권5호
    • /
    • pp.1244-1255
    • /
    • 2017
  • The space vector pulse width modulation (SVPWM) technique is a popular PWM method for medium voltage drive applications. Conventional SVPWM (CSVPWM) and bus clamped SVPWM (BCSVPWM) are the most common SVPWM techniques. This paper evaluates the performance of various advanced BCSVPWM strategies in terms of their harmonic distortion and switching loss based on a uniform frame work. A uniform frame work, pulse number captures the performance parameter variations of different SVPWM strategies for various number of samples with heterogeneous pulse numbers. This work compares different advanced BCSVPWM techniques based on the modulation index and location of the clamping position (zero vector changing angle ) of a phase in a line cycle. The frame work provides a fixed fundamental frequency of 50Hz. The different BCSVPWM switching strategies are implemented and compared experimentally on a 415V, 2.2kW, 50Hz, 3-phase induction motor drive which is fed from an IGBT based 2 KVA voltage source inverter (VSI) with a DC bus voltage of 400 V. A low cost PIC microcontroller (PIC18F452) is used as the controller platform.

Pulse-Sequence Analysis of Discharges in Air, Liquid and Solid Insulating Materials

  • Suwayno, Suwayno;Mizutani, Teruyoshi
    • Journal of Electrical Engineering and Technology
    • /
    • 제1권4호
    • /
    • pp.528-533
    • /
    • 2006
  • Electrical discharges may occur in gas, liquid as well as solid insulating materials. This paper describes the investigation results on the discharges in air, silicone oil and low density polyethylene (LDPE) using needle plane electrode system under AC voltage of 50 Hz. The experimental results showed that for discharge in air (corona), discharge pulses were concentrated around the peak of applied voltage at negative half cycle. For silicone oil positive as well as negative discharges were observed which concentrated around the peak of applied voltage. The positive pulse number was smaller but the magnitude was higher than that of negative discharge. Discharges in void took place at wider range of phase of applied voltage. The unbalance in pulse number and magnitude similar to that of oil discharges were observed. For electrical treeing in LDPE, the discharges were spread before the zero cross of the applied voltage up to the peak at both positive and negative half cycles. The discharge pulse sequence analysis indicated that the PD occurrence in air, oil and void were strongly affected by the magnitude of applied voltage. However, for electrical treeing it was observed that the discharge occurrence was strongly affected by the time derivative of the applied voltage (dv/dt).

Modeling of 18-Pulse STATCOM for Power System Applications

  • Singh, Bhim;Saha, R.
    • Journal of Power Electronics
    • /
    • 제7권2호
    • /
    • pp.146-158
    • /
    • 2007
  • A multi-pulse GTO based voltage source converter (VSC) topology together with a fundamental frequency switching mode of gate control is a mature technology being widely used in static synchronous compensators (STATCOMs). The present practice in utility/industry is to employ a high number of pulses in the STATCOM, preferably a 48-pulse along with matching components of magnetics for dynamic reactive power compensation, voltage regulation, etc. in electrical networks. With an increase in the pulse order, need of power electronic devices and inter-facing magnetic apparatus increases multi-fold to achieve a desired operating performance. In this paper, a competitive topology with a fewer number of devices and reduced magnetics is evolved to develop an 18-pulse, 2-level $\pm$ 100MVAR STATCOM in which a GTO-VSC device is operated at fundamental frequency switching gate control. The inter-facing magnetics topology is conceptualized in two stages and with this harmonics distortion in the network is minimized to permissible IEEE-519 standard limits. This compensator is modeled, designed and simulated by a SimPowerSystems tool box in MATLAB platform and is tested for voltage regulation and power factor correction in power systems. The operating characteristics corresponding to steady state and dynamic operating conditions show an acceptable performance.

원톱날 -원통 전극간의 오존 발생특성 (Ozone Generation of a Small Sawtooth-to-Cylinder Electrode Applied a Pulse Voltage)

  • 문재덕;김정호
    • 대한전기학회논문지
    • /
    • 제36권9호
    • /
    • pp.651-654
    • /
    • 1987
  • There are a number of small scale application fields of ozone, such as food conservation and/or storage in refrigerators, containers and storage rooms, deodorization in the production and living areas, protection against biohazards, bleaching of fabrics, etc. For these applications, miniaturization, ozone controllability and costdown of the ozonizer are the most essential points, whereas power efficiency is the most imporant factor in the case of a large scale ozonizer used in various industrial applications. It has been developed a novel sawtooth-to-cylinder type micro-ozonizer meeting above the three points by using a negative pulse corona discharge. As a result of the observations of pulse coronas affecting ozone generation, it is found that the maximum ozone concentration is generated at the pulse streamer coronas in both positive and negative case. The ozone concentration (20ppm/2l/min) generated by the negative pulse corona is about 2 times higher than that of the positive pulse corona, and could be controllable linearly by adjusting the dc input voltage of the [supply-inth ] cinventional small scale ozonizers. As a result, the present ozonizer is also very good to be used as a micro-ozonizer.

  • PDF