• Title/Summary/Keyword: Pulse Method

Search Result 3,146, Processing Time 0.03 seconds

Sleep Apnea Detection Using a Piezo Snoring Sensor: A Pilot study (코골이용 압전센서를 이용한 수면무호흡 검출에 관한 예비 연구)

  • Urtnasan, Erdenebayar;Lee, Hyo-Ki;Kim, Hojoong;Lee, Kyoung-Joung
    • Journal of Biomedical Engineering Research
    • /
    • v.35 no.4
    • /
    • pp.75-80
    • /
    • 2014
  • This paper proposed a method that can automatically classify sleep apnea by using features extracted from pulse rate variability(PRV) signals induced from piezo snoring sensor for patients with obstructive sleep apnea(OSA). We have extracted eight features(NN, SDNN, RMSSD, NN10, NN50, LF, HF and LF/HF ratio) based on time and frequency analyses of PRV. Sleep apnea was classified by a linear discriminant analysis(LDA). A performance was evaluated using snore recordings from 13 patients with OSA (ages: $54.5{\pm}10.5$ years, body mass index: $26.3{\pm}2.5kg/m^2$, apnea-hypopnea index: $19.2{\pm}6.0/h$). The sensitivity and specificity were $78.9{\pm}0.9%$ and $78.9{\pm}0.9%$ for training set and $77.7{\pm}10.9%$ and $79.0{\pm}2.8%$ for test set, respectively. Our study demonstrated the feasibility of implementing a piezo snoring sensor based on a portable device as a simple and cost-effective solution for contributing to the OSA screening.

The Kinetics of Hyperpolarization Activated Current$(i_f)$ in Sinoatrial Node of the Rabbit (토끼 동방결결에서 Pacemaker전류(과분극에 의해 활성화되는 내향전류, $i_f$)의 동력학적 특성에 관한 연구)

  • Earm, Yung-E
    • The Korean Journal of Physiology
    • /
    • v.17 no.1
    • /
    • pp.1-11
    • /
    • 1983
  • 1) The two microelectrode method was used to voltage clamp small preparations of rabbit sinoatrial node. The kinetics of hyperpolarization activated inward current, $i_f$ were analysed. 2) The hrperpolarization pulses activated $i_f$ current in the presence of $10^{-7}g/ml$ TTX and 2 mM $Mn^{2+}$. The activation range was in between -45 mV to -75 mV. The current magnitude was increased and time course was faster by strong hyperpolarization pulses. 3) Standard envelope tests indicated that this current is exponentially controlled by single gate. 4) Semilogarithmic plot of $i_f$ activation versus time was found to be linear in the activation range. The decrease in current magnitude and the shifts in activation curve and rate constants curve to the hyperpolarizing direction were obtained with $Ba^{2+}$, indicating that $Ba^{2+}$ shifts the voltage dependence of the gating kinetics, were partially reversed by 24 mM $K^+$.

  • PDF

Microleakage of class II posterior composite resin filling using various light curing methods (구치부 광중합 복합레진 수복시 여러 광조사 방법에 따른 미세변연누출에 관한 연구)

  • Jong-Uk Par;Byeong-Hoon Cho;Ho-Hyun Son;Chung-Moon Um;Hyuk-Choon Kwon
    • Restorative Dentistry and Endodontics
    • /
    • v.26 no.4
    • /
    • pp.326-331
    • /
    • 2001
  • 목적 - 최근 복합레진의 미세변연누출을 줄이기 위한 새로운 광중합 조사방법이 연구되고 있다. 또한 구치용 복합레진이 개발되면서 그 제조회사에서는 5mm 깊이까지 광중합이 가능하다고 소개하고 있다. 본 연구에서는 논리적 가설에 근거한 몇가지 광중합 조사방법이 구치부 class II 와동의 복합레진 충전시 미세변연누출에 어떠한 영향을 미치는지를 관찰하였다. 재료 및 방법 - 100개의 우식증이 없는 사람의 상하악 대구치를 사용했다. 각 치아에 교합-치은방향으로 4mm, 협설 4mm, 깊이 2mm의 class II 와동을 형성하여 인접치와 함께 베이스플레이트 왁스에 매몰하고 구치용 복합레진인 Surefil을 제조 회사의 지시대로 충전하였다. 이때 5가지의 광조사방법을 이용하여 5개의 군으로 나누어 중합하였다(Table 1). 수복된 치아들을 5$^{\circ}C$와 55$^{\circ}C$의 수조에서 번갈아 1분씩 총 500회의 온도변화를 주어 thermocycling을 실시한 후 근첨을 폐쇄하고 수복와동의 치은경계를 제외한 전 표면에 nail varnish를 2회 도포하였다. 2%의 methylene blue용액에 24시간 침적시키고 흐르는 물에 세척한 후 시편을 투명한 에폭시 레진에 매몰하였다. 매몰된 시편을 치아 장축에 평행하게 절단 연마하였다. 입체 현미경으로 미세변연누출을 관찰하고 Kruskal-Wallis One Way ANOVA 와 Dunn's Method로 통계처리 하였다. 결과 - 1. 미세누출은 1군, 4군과 5군, 2군 3군 순으로 증가였다. 이때 1군, 4군과 5군은 통계적 유의성이 없었다(P>0.05). 2. 2군의 경우 1군, 4군, 5군에 비교하여 유의성 있게 미세누출이 많았으며(P<0.05) 3군에 비하여 유의성 있게 적게 나타났다(P<0.05). 3. 3군의 경우 다른 방법들에 비교하여 통계적으로 유의성 있게 미세누출이 많았다(P<0.05).

  • PDF

The Fabrication of Nickel-Diamond Composite Coating by Electroplating Method (전기도금방법을 이용한 Ni-Diamond 복합도금층 제조에 대한 연구)

  • Moon, Yun-Sung;Lee, Jae-Ho;Oh, Tae-Sung;Byun, Ji-Young
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.14 no.1
    • /
    • pp.55-60
    • /
    • 2007
  • The codeposition behavior of submicron sized diamond with nickel from nickel electrolytes has been investigated. Electroplating of diamond dispersed nickel composites was carried out on a rotating disk electrode (RDE). The effects of current type and current density on the electrodeposited Ni-diamond composite coating were investigated. The effects of surfactants on the composite coating were also investigated. The hardness of coating was measured with varying electroplating conditions using Micro Vickers. As diamond was incorporated into the coating, the hardness of coating as well as the wear resistance was improved. The hardness of the coating was increased as much as 100% and the wear resistance was improved as much as 27%. The hardness of composite coating layer increased slightly at the diamond content of above 20 gpl.

  • PDF

Inverse Scattering Technique with Series Expanded Field of Dielectric Cylinders in Angular Spectral Domain (각스펙트럼 영역에서 전개함수 전계를 이용한 유전체 실린더에서의 역산란)

  • Kim, Ha-Chul;Choi, Hyun-Chul;Son, Hyon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.9 no.5
    • /
    • pp.698-707
    • /
    • 1998
  • For inverse scattering problems reconstructing cross-sectional permittivity distributions of dielectric cylinders, the angular spectral inverse technique using the moment method with pulse basis function suffers from large reconstruction error even if very small noise due to requiring the higher spectral informations on the larger cross-section of the cylinder. To reduce the number of higher-order spectra, this paper presents an improved inverse technique in angular spectral domain applying the moment procedure with a series-expansion basis function for the induced field in each enlarged cross-sectional cell. By choosing adequate spectra and averaging over the enlarged cells with a suitable weighting function, the reconstruction profiles reveal fine enough to suppress the noise effect significantly.

  • PDF

A Study on Sandbag Management, vital sign, Pain and Hemorrhage after Kidney Biopsy in Children with Nephrotic Syndrome (신장증 환아의 신생검후 모래주머니 적용시간에 따른 활력징후, 통증 및 출혈에 관한 연구)

  • Cho Kyoul-Ja;Paik Seung-Nam;Park Soon-Hee
    • Child Health Nursing Research
    • /
    • v.9 no.1
    • /
    • pp.28-35
    • /
    • 2003
  • Purpose: The purpose of this study is to investigate correlations in vital sign changes, the severity of pain, signs of complications, and the duration of sandbag management in order to suggest a standardized practice related to sandbag management in children with Nephrotic Syndrome(NS). Method: From October 2000 to May 2001, seventy children with NS who underwent kidney biopsy were interviewed at one hospital in Seoul Korea, and participated in this study. Result: 1) The average sandbag applying time after kidney biopsy was 18.1 hours. 2) Systolic blood pressure and respiration increased until 15 minutes after kidney biopsy, after then, they decreased signifi- cantly (systolic BP, p= .006; respiration, p= .029). However, no significant changes were noted in diastolic blood pressure and pulse. 3) Pain was reported minimal for 1 hour after kidney biopsy. The severity of pain increased until 12 hours after the procedure, then, decreased significantly(p= .0001). 4) Reported complications were hematuria (74.7%) and abnormal sonogram (32.9%). No apparent bleeding on the biopsy region was reported in any children. Conclusion: From these findings, it is possible to change the protocols of the duration of absolute bed rest time and sandbag application management shortly after kidney biopsy. But it is needed to study the fit protocols for kidney biopsy. Several implications in nursing practice are suggested. 1) Replicated studies for more participants are needed. 2) Further research on the effect of sandbag application after kidney biopsy is required. 3) The best duration of sandbag application management after kidney biopsy need to be investigated.

  • PDF

ASSESSMENT OF VITAL SIGNS IN PEDIATRIC DENTAL SEDATION USING CHLORAL HYDRATE AND HYDROXYZINE (소아환자에서 chloral hydrate와 hydroxyzine을 사용한 진정치료 시 생징후 평가)

  • Lee, Ju-Hyun;Park, Ho-Won
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.29 no.3
    • /
    • pp.455-462
    • /
    • 2002
  • Currently, the ages of the patients visiting dental hospital for dental care are becoming younger and the interest in the treatment for the handicapped and incapable of cooperation children increases. As a method for treatment of these patients, the sedation treatment is considered. A dental sedation using chloral hydrate and hydroxyzine of them were used widely and for a long time. In this study, the samples were consisted of incapable of cooperation or very young children required treatment of restoration under local anesthesia. Then, the vital signs were accessed in pediatric dental sedation using the combination of chloral hydrate and hydroxyzine. As a result of this study, the vital signs were little different in pediatric dental sedation using the combination of chloral hydrate and hydroxyzine. Simply, the respiration rate and pulse rate decreased according to sleeping of patients. Therefore, the sedation using the combination of chloral hydrate and hydroxyzine induced to appropriate sedation in incapable of cooperation or very young children with little effects of vital signs.

  • PDF

A Study on the LCC Type High Frequency DC/DC Converter for Contactless Power Supply System (비접촉 전원장치에 적용한 LCC형 고주파 공진 DC/DC 컨버터에 관한 연구)

  • Kim, Dong-Hee;Hwang, Gye-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.6
    • /
    • pp.55-64
    • /
    • 2007
  • This paper represents characteristics and design example of series loaded LCC type high frequency resonant DC-DC converter with variable parallel capacitor in the secondary side of inductive power transformer. In this converter, ZVS(zero voltage switching) technique is applied to reduce turn-off switching losses, and the applied converter used the PFM switching pattern to control output voltage. The operating characteristics of the proposed converter is analyzed using nomalized parameter such as switching frequency and load factor with varing the secondary parallel resonant capacitor. The results of analysis show the operating characteristics and design method of the proposed converter using characteristic values. And the proposed converter can be applied for the contactless power supply with linear transfer system such as dean room facilities of semiconductor and Flat Panel Display.

A Spatio-Temporal Density Measurement of NO Molecules in Pulsed Barrier Discharge Using Laser Induced Fluorescence (레이져 유기형광법을 이용한 펄스 배리어 방전 공간에서의 NO분자에 대한 시·공간적 밀도변화 측정)

  • Han, Sang-Bo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.5
    • /
    • pp.160-168
    • /
    • 2010
  • This paper tried to find out NO generation and removal mechanisms in the space of the atmospheric pulsed barrier discharge using laser induced fluorescence method, which is a very effective approach to the measurement of spatio-temporal density of specific molecules. The propagation velocity of the primary streamer reaches about $2.7{\times}10^6$[m/s] and the secondary streamer is produced in the vicinity of positive electrode after the primary streamer finished. In this work, pulse Nd:Yag and Dye lasers are used for generating the specific wavelength of 226[nm], which is possible to excite NO molecules into $A^2{\Sigma}^+{\rightarrow}X^2{\prod}$(0,0) and fluorescence signals as the transition of $A^2{\Sigma}^+{\leftarrow}X^2$(0,2) is measured. For the effective removal of NO molecules in the plasma discharge process, the lower oxygen contents are needed and the influence of secondary streamer for the reduction mechanism of NO molecules is important

Development of Autonomous Navigation Algorithm for Very Small Unmanned Surface Vehicle based on GPS (GPS 기반의 초소형 무인선박을 위한 자율항법 알고리즘 개발)

  • Kim, Hyo-Il;Jun, Seung-Hwan
    • Journal of Navigation and Port Research
    • /
    • v.33 no.5
    • /
    • pp.303-308
    • /
    • 2009
  • Recently, unmanned systems have been studied and developed in various areas including aircrafts, automobiles and vessels. In addition, many researches about unmanned systems in Korea have been studying actively with the advancement of IT However, it is not satisfied with the result of the researches and developments. Bemuse of the reason we've here tried to make a very small USV which is a barge type. We applied the Great circle navigation calculation based on GPS to the autonomous navigation algorithm and used the LabVIEW 8.2 developed by NI corp. for programming The engine and rudder were controlled by pulse width modulation method. The engine system was composed of the DC motor and ESC(Electronic Speed Controller). It was also applied by the direct cooling system using DC motor pump. A very small USV was designed and made by ourself and it was verified the effectiveness of autonomous navigation algorithm through the tests at the sea.