• 제목/요약/키워드: Pulse Magnetic Treatment

검색결과 36건 처리시간 0.024초

3 Stage 2 Switch Application for Transcranial Magnetic Stimulation

  • Ha, Dong-Ho;Kim, Whi-Young;Choi, Sun-Seob
    • Journal of Magnetics
    • /
    • 제16권3호
    • /
    • pp.234-239
    • /
    • 2011
  • Transcranial magnetic stimulation utilizes the method of controlling applied time and changing pulse by output pulse through power density control for diagnosis purposes. Transcranial magnetic stimulation can also be used in cases where diagnosis and treatment are difficult since output pulse shape can be changed. As intensity, pulse range, and pulse shape of the stimulation pulse must be changed according to lesion, the existing sine wave-shaped stimulation treatment pulse poses limitations in achieving various treatments and diagnosis. This study actualized a new method of transcranial magnetic stimulation that applies a 3 Stage 2 Switch( power semiconductor 2EA) for controlling pulse repetition rate by achieving numerous switching control of stimulation coil. Intensity, pulse range, and pulse shape of output can be freely changed to transform various treatment pulses in order to overcome limitations in stimulation treatment presented by the previous sine wave pulse shape. The method of freely changing pulse range by using 3 Stage 2 Switch discharge method is proposed. Pulse shape, composed of various pulse ranges, was created by grafting PFN (Pulsed Forming Network) through AVR AT80S8535 one-chip microprocessor technology, and application in transcranial magnetic stimulation was achieved to study the output characteristics of stimulation treatment pulse according to delaying time of the trigger signal applied in section switch.

펄스 자기장을 이용한 잔류 응력 완화 연구 (A Study on the Stress Relief by Pulse Magnetic Treatment)

  • 오주숙;양원존;이종훈;박용호
    • 열처리공학회지
    • /
    • 제24권3호
    • /
    • pp.149-155
    • /
    • 2011
  • Residual stress relief by pulse magnetic treatment is attractive because the process is carried out at room temperature and magnetic fields that are easy to produce and control can be used. This study shows that strong pulse magnetic treatment can lead to stress relaxation of structural steels instead of a conventional heat treatment process. And it makes a comparative study about pulse magnetic treatment and tempering by using Larson-Miller equation. When the specimen was subjected to a pulse magnetic treatment process the residual stress in the specimen was reduced by about 13.8%. It could be compared with tempering at $200^{\circ}C$ for 2hours by using thermal effect of Larson-Miller equation. As a result, it is considered that the pulsed magnetic treatment have an effect of the stress relation by tempering at $200^{\circ}C$ for 2 hours.

Design and embodiment of variableness band style magnetic field nerve stimulation system that apply $1^{trigger}$ $2^{mode}$ magnetic field treatment Probe for disease treatment

  • Kim, Whi-Young;Park, Sung-Joon
    • Journal of information and communication convergence engineering
    • /
    • 제6권4호
    • /
    • pp.411-416
    • /
    • 2008
  • When compose magnetic field curer by belt and band style and need by magnetic field ripple last month, produce self-discipline roof. Bred in muscle disease (lumbago, backbone disease, corpulence) back. Result that study, manufactured various variableness band style - magnetic field probe firstly. Can establish self-discipline treatment pulse price by disease secondly. Could seek correct variableness band punishment, - magnetic field probe relationship implementation and property in waist, and so on, shoulder, neck, arm, leg, ankle, wrist etc. by third. Could find variableness band style energy value that need in-magnetic field Probe's treatment by fourth. This research could design pulse of self-discipline in band form and apply each according to disease.

신경계 치료를 위한 루프 프로브형 자기자극기의 시뮬레이터 (The simulator loop probe style magnetic stimulation design for a nervous system treatment)

  • 김휘영
    • 디지털산업정보학회논문지
    • /
    • 제5권3호
    • /
    • pp.29-37
    • /
    • 2009
  • It is as result that study to apply mini magnet nerve curer in peripheral nervous system disease treatment. Simulator and embodied action power and Control Unit in cylinder form of magnet roof object firstly. Yielded service area about special quality of probe of loop object cylinder style and treatment area dimension and distance of treatment pulse secondly. Embody pulse forming course energy value by Probe's form by third, could embody treatment pulse by disease. Specially, through a special quality experiment, saved Damping pulse form and treatment digital forming etc. variously. Lately, embodied this to aid a little in disease treatment that follow that there is no invasion that there is no stimulation by medicine development. Neuralgia, muscular disease and Altzheimer, with stroke etc. is becoming the matter of concern and interest which disease of adult etc. it is same is important. And the melancholia in compliance with the modern direction of a ceremony which is complicated and garrulous, trillion it will cry and symptoms, it is a tendency where the emotional obstacle etc. nervous psychiatric disorder patient is increasing at class speed. But currently the applicator it will be able to treat like this disease almost it is a condition which is wholly lacking. Consequently like this disease it used magnetic stimulation and it diagnosed and the equipment it will be able to treat plan and it embodied.

말초신경계 치료를 위한 미니 Loop - 코일 삽입형 자기치료기 (Mini loop coil magnetic curer for peripheral nervous system treatment)

  • 김휘영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.49-51
    • /
    • 2007
  • It is as result that study to apply mini magnet nerve curer in peripheral nervous system disease treatment. Design and embodied action power and Control Unit in cylinder form of magnet roof object firstly. Yielded service area about special quality of probe of roof object cylinder style and treatment area dimension and distance of treatment pulse secondly. Embody pulse forming course energy value by Probe's form by third, could embody treatment pulse by disease. Specially, through a special quality experiment, saved Damping pulse torn and treatment pulse form etc. variously. Lately, embodied this to aid a little in disease treatment that follow that there is no invasion that there is no stimulation by medicine development. Go amplitude treatment pulse (traditional magneto-therapy of greatly great that strong) does curative effect greatest at short time and becomes thought that demand is magnified greatly at the future in this research.

  • PDF

TreatmentWD Pulse Application for Transcranial Magnetic Stimulation

  • Ha, Dong-Ho;Kim, Jun-Il;Lee, Sun-Min;Bo, Gak-Hwang;Kim, Whi-Young;Choi, Sun-Seob
    • Journal of Magnetics
    • /
    • 제17권1호
    • /
    • pp.36-41
    • /
    • 2012
  • The transcranial magnetic stimulation recharges the energy storing condenser, and sends the stored energy in the condenser to the pulse shaping circuit, which then delivers it to the stimulating coil. The previous types of transcranial magnetic stimulation required a booster transformer, secondary rectifier for high voltages and a condenser for smooth type. The energy storing condenser is recharged by switching the high-voltage direct current power. Loss occurs due to the resistance in the recharging circuit, and the single-pulse output energy in the transcranial magnetic stimulation can be changed because the recharging voltage cannot be adjusted. In this study a booster transformer, which decreases the volume and weight, was not used. Instead, a current resonance inverter was applied to cut down the switching loss. A transcranial magnetic stimulation, which can simultaneously alter the recharging voltage and pulse repeats, was used to examine the output characteristics.

말초신경계 치료를 위한 미니 Loop - 코일 삽입형 자기치료시스템의 설계 및 제작 (Design and manufacture of mini loop coil magnetic curer for peripheral nervous system treatment)

  • 김휘영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.153-155
    • /
    • 2007
  • It is as result that study to apply mini magnet nerve curer in peripheral nervous system disease treatment. Design and embodied action power and Control Unit in cylinder form of magnet roof object firstly. Yielded service area about special quality of probe of roof object cylinder style and treatment area dimension and distance of treatment pulse secondly. Embody pulse forming course energy value by Probe's form by third, could embody treatment pulse by disease. Specially, through a special quality experiment, saved Damping pulse form and treatment pulse form etc. variously Lately, embodied this to aid a little in disease treatment that follow that there is no invasion that there is no stimulation by medicine development Go amplitude treatment pulse (traditional magneto-therapy of greatly great that strong.) does curative effect greatest at short time and becomes thought that demand is magnified greatly at the future in this research.

  • PDF

Arm Cortex S3C2440 Microcontroller Application for Transcranial Magnetic Stimulation's Pulse Forming on Bax Reactive Cells and Cell Death in Ischemia Induced Rats

  • Tac, Han-Ho;Kim, Whi-Young
    • Journal of Magnetics
    • /
    • 제21권2호
    • /
    • pp.266-272
    • /
    • 2016
  • Transcranial magnetic stimulation devices has been used mainly for diagnostic purposes by measuring the functions of the nervous system rather than for treatment purposes, and has a problem of considerable energy fluctuations per repeated pulse. The majority of strokes are caused by ischemia and result in brain tissue damage, leading to problems of the central nervous system including hemiparesis, dysfunction of language and consciousness, and dysfunction of perception. Control is difficult and the size is large due to the difficulty of digitalizing the energy stored in a capacitor, and there are many heavy devices. In addition, there are many constraints when it is used for a range of purposes such as head and neck diagnosis, treatment and rehabilitation of nerve palsy, muscle strengthening, treatment of urinary incontinence etc. Output stabilization and minimization of the energy variation rate are required as the level of the transcranial magnetic stimulation device is dramatically improved and the demand for therapeutic purposes increases. This study developed a compact, low cost transcranial magnetic stimulation device with minimal energy variation of a high repeated pulse and output stabilization using a real time capacitor charge discharge voltage. Ischemia was induced in male SD rats by closing off the common carotid artery for 5 minutes, after which the blood was re-perfused. In the cerebrum, the number of PARP reactive cells after 24 hours significantly decreased (p < 0.05) in the TMS group compared to the GI group. As a result, TMS showed the greatest effect on necrosis-related PARP immuno-reactive cells 24 hours after ischemia, indicating necrosis inhibition, blocking of neural cell death, and protection of neural cells.

코크로프트-월톤회로와 반파공진인버터를 적용한 경두개 자기자극장치 (Transcranial Magnetic Stimulation using Cockroft-Walton Circuit and Half Bridge Resonant Inverter)

  • 김휘영;황보각
    • 한국콘텐츠학회논문지
    • /
    • 제10권4호
    • /
    • pp.257-264
    • /
    • 2010
  • 기존의 경두개 자극장치는 일정한 자극치료 펄스의 정현파 모양으로 다양한 치료 및 진단을 하는데 한계가 있다. 본 연구에서, 치료 및 진단마다 요구되는 세기, 폭, 펄스모양이 다른 코로로프트-월톤회로와 반파브리지 공진 인버터를 도입하여 주파수와 전압이 가변되는 새로운 장치를 제안하고자 한다. 기존장치 보다 많은 장점을 가진다. 첫째로 고압 변압기를 가지지 않는다. 둘째로 스위칭손실이 적고, 출력에너지를 정밀하게 제어할 수가 있다. 세째로 자극의 세기, 폭, 펄스모양이 다양하다. 결과적으로 변압기를 사용하지 않는 반파브리지 인버터와 코크로프트-월톤회로를 적용하여 개선된 특성과 실험을 구하였다.

Acceleration of Cell Proliferation and Gene Expression in Human Chondrosarcoma Cells Stimulated by Strong Pulse Magnetic Field

  • Shin, Sung Chul;Chung, Eui Ryong;Hwang, Do Guwn
    • Journal of Magnetics
    • /
    • 제18권1호
    • /
    • pp.14-20
    • /
    • 2013
  • For the treatment of osteoarthritis, pulsed electromagnetic field stimulus has been suggested as a useful therapeutic method in rehabilitative medicine. Most studies have been performed under low-frequency and low-energy to find out biological properties for stimulating chondrocyte with pulsed magnetic field. In this study, the effect of strong pulse magnetic field on the human chondrosarcoma cells (SW-1353) has been investigated by means of cell counting, morphologies, and gene expression of cartilage extracellular matrix genes. The SW-1353 cells were exposed under the field intensities of 270, 100, 55, 36, and 26 mTesla during 6 hours a day in 5 consecutive days. The pulse magnetic field with an LRC oscillating signal has the pulse width of 0.126 msec and stimulation period of 1 sec. For the 270 and 100 mTesla stimulation, the cell proliferation significantly increased in 21-24% as compared with the non-stimulated cells. Gene expression of cartilage extracellular matrix genes (ACAN, COMP and COL2A1) was assayed by quantitative real time-PCR method. The ACAN gene expression showed a significant brightness, which means the increase on gene expression, compared with the non-stimulated cells. Our results suggest that the strong pulse magnetic field stimulation can be utilized to accelerate cell proliferation and gene expression on human chondrosarcoma cells.