• 제목/요약/키워드: Pulse Energy

검색결과 1,308건 처리시간 0.028초

상한론(傷寒論)과 사상의학(四象醫學)의 병기(病機)에 대한 비교연구(比較硏究) - 동의수세보원(東醫壽世保元) 변증론(辨證論)을 중심(中心)으로 - (A comparative study on between Shanghanlun(傷寒論) and Sa-sang constitutional medicine(四象醫學) in Pathogenesis)

  • 이광영;박찬국
    • 대한한의학원전학회지
    • /
    • 제11권1호
    • /
    • pp.676-718
    • /
    • 1998
  • After a comparative study on between Shanghanlun(傷寒論) and Sa-sang constitutional medicine(四象醫學) in Pathogenesis, I got a conclusion like this. Sa-sang consitutional medicine(四象醫學) changed the directions to the medicine in the center of personality from the medicine in the center of Shanghanlun(傷寒論)'s demonstration, devided the personality of people by the size of Organ system(臟腑) into 4types of Tae-eum, Yo-yang, Tae-yang, Yo-eum(太少陰陽), and explains all the course of physiology, pathology, diagnosis, therapy of the body on the point of constitutional view. Comparing the features of two medicines, Shanghanlun(傷寒論) and Sa-sang constitutional medicine(四象醫學), Shanghanlun(傷寒論) devided the diseases into the three type of eum-yang based on eight principal syndroms(八綱原理), in accordance with evidence of illness, pulse and studied the therapy, Shanghanlun(傷寒論) set up the basis of medicine which is based on overall of symptoms and signg(辨證論治醫學). Sa-sang constitutional medicine(四象醫學) distinguished the image(象) which is devided by the size of inherited Organ system(臟腑), refered to the symptom of diseases(病症) and decided the therapic directions. So Sa-sang constitutional medicine(四象醫學) gave more accuracy to the therapy by subdeviding the process of differenciation of case(辨證) into 2 steps of differenciation of image(辨象) and differenciation of case(辨證). In view of etiologic factor, Shanghanlun(傷寒論) regarded it as a invading of pathogenic factors(邪氣), so Shanghanlun(傷寒論) has the medical theory of pathogenic factors(邪氣). But Sa-sang constitutional medicine(四象醫學) regarded it as a disorder of the genuine energy(正氣)'s movements(升降緩速), so Sa-sang constitutional medicine(四象醫學) has the medical theory putting first of genuine energy(正氣). But Shanghanlun(傷寒論) also recognized the constitutional difference basically and Sa-sang consitutional medicine(四象醫學) devided the constitution into Tae-eum, Yo-yang, Tae-yang, Yo-eum(太少陰陽) and explained the food-air-fluid metabolism(飮食-氣液之氣病證) as cold-hot, cool-warm and devided the the symptom of diseases(病症) into the interior and the exterior(表裏) as the up-down, slow-fast movements of eum-yang and insufficiency and excessiveness is between them. In the end, Sa-sang constitutional medicine(四象醫學) has the theory of eight principal syndroms(八綱原理) faithfully which is the theory of differenciation of case(辨證理論) of Shanghanlun(傷寒論). Therefore Shanghanlun(傷寒論) made a lot of influence on originating Sa-sang constitutional medicine(四象醫學), Sa-sang constitutional medicine(四象醫學) is the theory which is based on existing medical theory including Shanghanlun(傷寒論) and composed the new medical theory to the constitutional point of view. Sa-sang constitutional medicine(四象醫學) enriched the medical theory and developed the clinical medicine so it has the historical value in the medicine.

  • PDF

만성전립선염환자(慢性前立腺炎患者) 40예(例)에 대(對)한 임상적(臨床的) 고찰(考察) (The Clinical Study on 40 Cases of Patient with Chronic Prostatitis)

  • 조충식;김철중
    • 혜화의학회지
    • /
    • 제8권2호
    • /
    • pp.245-257
    • /
    • 2000
  • A clinical study was done 40 patients of chronic prostatitis who was treated in Dept. of Internal Medicine, Oriental Medicine Hospital, Taejon University, from 1 Mar. 1999 to 31 Oct. 1999. The results were as follows. 1. In distribution of age, 30's and 40's were 57.5% the most, 20's and 60's were 35.0%, 50's was 7.5%. 2. In distribution of past history, the urethritis(45.0%) was the most. 3. In distribution of ocupation, a white-collar worker was 35.0%, a business man was 22.5%, a public servant was 12.5%, etc. 4. Sitting the mean time of day were distributed 5~7 hours, above 7 hours, 3~5 hours, under 3 hours, etc. 5. The resting interval of a long distance drive were distributed 2 hours(35.0%), 3 hours(32.5%), etc. 6. The habit of enduring ejaculation during sexual intercourse was showed 45.0%. 7. The habit of enduring urination was showed 20.0%. 8. Influency of mental stress was showed 90.0%. 9. Ten cases(25.0%) were showed riding horse or riding bicycle. 10. Four cases(10.0%) were showed wearing tight trousers. 11. The habit of put a wallet his hip pocket was showed 57.5%. 12. The most common symptom was distributed the others symp-tom(66.8%) and the voiding symptom(63.3%) more than pain-neuro-logical symptom(37.5%) and symptom related with sexual function (26.6%). 13. In distribution of palpation, lower abdominal pain, lumbar pain, perineal or parascrotal pain were mostly showed right side. Moreover diagnosis of pulsation was weakly showed chi pulse of right. 14. Duration of disease were distributed above 1 year(82.5%), under 1 year(17.5%). Degree of prostatitis was severe showed adove 1 year. 15. The distribution of WBC count of the prostatic secretion, com-paring with before therapy and after therapy, were showed from 5 cases to 0 case in very many/HPF, from 23 cases to 13 cases in many/HPF, from 12 cases to 13 cases in 10~30/HPF, from 0 case to 13 cases in under 10/HPF. 16. Therapeutic improvement of symptom were distributed pain-neurological symptom(94.8%), the others symptom(90.8%), the void-ing symptom(89.6%) and symptom related with sexual function(67.5%). 17. Differentiation of symptoms and signs were distributed dificiency of spleen-lung vital energy, wetness-heat of lower warmer, dificiency of spleen-kidney yang, dificiency of kidney yin, wetness-phlegm, dificiency of vital energy and blood. The prescriptions were Bojungikgitang(44.6%), Yukmijihwangtang(20.7%), Palmijihwangtang(12.0%), etc.

  • PDF

액체금속로 소듐내부 가시화를 위한 초음파 웨이브가이드 센서 개발 (Development of Ultrasonic Waveguide Sensor for Under=Sodium Viewing in Liquid Metal Reactor)

  • 주영상;이재한
    • 비파괴검사학회지
    • /
    • 제26권1호
    • /
    • pp.18-24
    • /
    • 2006
  • 액체금속로 원자로 노심과 내부구조물 들은 불투명한 소듐 내에 잠겨 있어 육안검사를 수행할 수 없다. 액체금속로 내부구조물의 육안검사를 수행하기 위해서는 초음파를 이용한 소듐내부 가시화가 적용되어야 한다. 본 연구에서는 소듐내부 가시화에 적용하기 위한 판형 초음파 웨이브가이드 센서를 개발하였다. 웨이브가이드 센서에서의 판파 전파특성을 분석하고 판파 적용모드로 제0차 반대칭 $A_0$ 모드를 선정하였다 웨이브가이드 센서에 액체 웨지를 적용하여 $A_0$ 모드의 저주파수 분산 영역에서 판파가 발진되도록 하였으며 입사펄스의 주파수 변조에 의하여 초음파 빔 방사각을 변환시킬 수 있는 새로운 방법을 제안하였다 본 방법은 웨이브가이드 센서를 기계적으로 구동하지 않고 빔 방사각을 조정할 수 있어 기존 웨이브가이드 센서의 구동 제한성을 극복할 수 있게 해 준다. 웨이브가이드 센서의 빔 방사각 변환 특성을 실험적으로 검증하였으며, 수중 C-스캔 시험을 수행하여 웨이브가이드 센서의 소듐내부 가시화 적용 가능성을 확인하였다.

Er : YAG 레이저 조사가 법랑질 표면 변화와 전단강도에 미치는 영향 (SEM EVALUATION AND SHEAR BOND STRENGTH OF ER : YAG LASER IRRADIATION ON ENAMEL SURFACE)

  • 임형수;이창섭;이상호
    • 대한소아치과학회지
    • /
    • 제28권3호
    • /
    • pp.374-382
    • /
    • 2001
  • Er : YAG 레이저는 치아 경조직 삭제에 효과적인 파장을 지니고 있어 근래에 와동형성의 목적으로 많이 사용되고 있다. 본 연구의 목적은 법랑질에 대한 Er : YAG 조사가 전단강도에 있어 산부식법을 대체할 수 있는 표면처리 방법인지를 알아보고자 함이다. 복합 레진과 법랑질 사이의 접착력을 향상하기 위한 표면 처리 목적의 레이저 에너지를 측정하기 위해 24개의 법랑질 시편에 각각 정촛점과 탈촛점 방식으로 30mJ부터 150mJ까지 1Hz로 조사하였다. 4개의 시편은 37% 인산을 15초간 적용하고 세척, 건조하였다. 30개의 시편은 주사전자현미경으로 관찰하였다. 복합 레진과의 전단강도를 측정하기 위해 90개의 법랑질 시편을 3군으로 나누었다. 대조군은 37% 인산을 15초간 적용 후 세척하고 건조하였으며, 제 1군은 60mJ, 10Hz로 조사하였다. 제 2군은 먼저 60mJ, 10Hz로 조사한 후 37% 인산으로 15 초간 적용 후 세척하고 건조하였다. 실험결과는 다음과 같다. 1. 주사전자현미경 관찰결과, 정촛점, 탈촛점 모두 60mJ, 1Hz 이상으로 조사했을 경우 제 3형의 산부식 양상과 유사한 법랑질 표면을 얻을 수 있었다. 2. 정촛점과 탈촛점 방식 모두 에너지가 증가할수록 균열 양상이 더 심해졌다. 3. 가장 높은 평균 전단강도를 보인 군은 산부식군(Control)이었고 60mJ, 10Hz의 pulse로 조사한 후 산부식한 군(Group 2), 레이저만 조사한 군(Group 1)순으로 나타났으며 3 군간에 통계학적으로 유의한 차이를 보였다.(p<0.001)

  • PDF

제병원후론(諸病源候論)의 중풍(中風)에 관한 고찰(考察) (A study on a term of "Jung Pung 中風" in 'Jae-Byoung-Won-Hu-Ron 諸病源候論')

  • 김선영;정승현;임성우;신길조;이원철
    • 동국한의학연구소논문집
    • /
    • 제5권
    • /
    • pp.209-229
    • /
    • 1996
  • The purpose of this study is to investigate the recognition of "Jung Pung(中風)" mentioned in "Jae-Byoung-Won-Hu-Ron(諸病源候論)" The conclusion would be summerized as follows. 1. "Pung Byoung(風病)" is a symptom that man was damaged by "Pung Chi(風氣)", which is a wide meaning inclusive of cloudiness of conscious, apasia and the limbs disorder of "Jung Pung(中風)", "Bi 痺symptom", "Yeuk Jeil Pung(歷節風)", the skin disease, psychopathy and leprosy. 2. In cause of "Jung Pung(中風)", this book was received the theory of invasion of "Pung Sa (風邪)" from outside claimed in "Nae Kyoung(內經)", "Kum Gaeu Yo Rak(金?要略)", but in a viewpoint of "Hyel Chi(血氣)", "Young Yui(營衛)" and "Bi Yui Heo Sil(脾胃虛實)", especially, insists on the weakness of "Bi Yui(脾胃)" function. 3. In the pathology of "Jung Pung(中風)", there was a recognition that symptoms appear following each "Jang Bu(臟腑)" invaided and changed by a way of "Kyoung Rak Jang Bu(經絡臟腑)", because "Pung Sa(風邪)" invades the space of the skin, disturbs the circulation of "Hyel Chi(血氣)" in a inner and isn't given out in a outer. 4. Thereare, , , , , in the symptoms of "Jung Pung(中風)" and ", , , , , , in the similar symptoms of "Jung Pung(中風)". 5. The principle of treatement is "getting sweating, helping the insufficent energy and diminishing the sufficent energy", but the presciption isn't mentioned and "Do-in Method(導引法)" was recorded after each symptom because of taking a serious view of "Bo-Yang-Sun-Do(補養宣導)" 6. The prognosis of "Jung Pung(中風)"is suggested in a view of pulse diganosis, symptoms and is bad in case of appearance of no sweating, rigidity, vomitting a bubble and apasia.

  • PDF

고 고도 전자기파(HEMP) 발생과 전파해석 및 방호실 최적 설계 Tool 개발 (Development of the HEMP Generation, Propagation Analysis, and Optimal Shelter Design Tool)

  • 김동일;민경찬
    • 한국정보통신학회논문지
    • /
    • 제18권10호
    • /
    • pp.2331-2338
    • /
    • 2014
  • 북한의 핵폭탄과 미사일 기술개발이 진전됨에 따라 고 고도 핵전자기파(HEMP)에 대한 위협이 새롭고 절박하게 인지되고 있는데, 일례로 이미 북한이 수개의 핵폭탄을 개발 보유하고 있으며 북한이 남한에 대한 핵탄두 운반 능력을 가지고 남한을 위협하고 있다. ITU K78, K81 그리고 IEC에서는 EMP/HEMP로부터 프로세서 내장 기기의 오동작을 줄이기 위해 항해 통신장비를 포함한 산업용 설비에 대한 대책을 권장하고 있으나, 이에 대한 의사시험은 1960-1990년대 미국공군무기연구소(USA/AFWL)의 논문들을 토대로 수행할 수 밖에 없다. 이 모의 시험결과는 모든 HEMP 관련 제품이 강력하게 수출을 통제하고 있기 때문에 북한의 위협에 직면한 남한으로서는 매우 중요한 연구 활동의 결과이다. 저자 등이 새롭게 개발한 HEMP cord는 HEMP의 발생과 전파현상 분석, 방호실 설계 툴, 흙과 암반으로 구성된 다충 구조에서 전자파 에너지의 감쇠량 그리고 HEMP 필터 설계 툴을 포함하고 있다. 특히 다층구조에서 전자파 감쇠량 연산 툴은 흙과 암반이 매우 다양한 특성을 가지고 있기 때문에 많은 실측 데이터를 바탕으로 최소자승법에 의하여 해석하였다.

중성자 모니터링을 위한 전도성 10B 박막 개발 (The development of conductive 10B thin film for neutron monitoring)

  • 임창휘;김종열;이수현;정용주;최영현;백철하;문명국
    • Journal of Radiation Protection and Research
    • /
    • 제39권4호
    • /
    • pp.199-205
    • /
    • 2014
  • 중성자 검출분야에서$^3He$는 높은 중성자 검출효율 때문에 아주 많이 사용되고 있다. 하지만 2009년 초반부터 발생하고 있는 전세계적인 $^3He$의 품귀현상으로 인하여 가격이 급등하고 수급이 어려워졌기 때문에 대체 중성자 검출물질에 대한 필요성이 높아졌다. 그러므로 중성자 검출물질로 사용될 수는 있지만 $^3He$에 비해 반응효율이 낮아 중성자 검출용으로 주로 사용되지 않던 물질들을 사용하여 검출기를 제작하는 연구가 다시 활발하게 진행되고 있다. $BF_3$, $^6Li$, $^{10}B$, $Gd_2O_2S$ 등과 같은 $^3He$ 대체 물질들 중 하나인 $^{10}B$은 손쉬운 감마선 구별, 무독성, 낮은 가격 등과 같은 여러 장점으로 인하여 여러 연구그룹에서 연구되고 있다. $^{10}B$ 박막을 이용한 중성자 검출은 중성자와 반응하여 발생되는 2차 방사선을 측정하여 간접적으로 중성자를 측정하는 검출기법이다. 반응을 통해 생성된 알파입자의 비정은 고체 내에서 아주 짧기 때문에 $^{10}B$ 층은 박막 형태로 얇게 제작해야 한다. 그러므로 중성자와 박막의 반응을 통해 발생되는 알파입자의 검출효율을 증가시키기 위해서는 $^{10}B$ 박막의 두께를 얇게 제작하는 것이 중요하다. 하지만 박막의 두께를 얇게 제작하는 것은 중성자와 반응하여 생성되는 알파입자의 수집효율을 증가시키는 장점이 있지만 또한 중성자와 반응할 단면적을 감소시키는 단점이 있다. 본 논문에서는 리튬이온전지에 사용되는 초박막 극판 제조 기술을 이용하여 중성자 검출을 위한 대략 $60{\mu}m$ 두께의 얇은 $^{10}B$ 박막을 제작하였다. 그리고 전도성, 분포, 점착력, 유연성와 같은 간단한 물리적 실험을 통해 제작된 $^{10}B$ 박막의 물성을 확인하였다. 또한, 제작된 $^{10}B$ 박막을 사용하여 중성자 모니터링을 위한 비례계수기 제작하고 이를 이용하여 한국원자력연구원의 중성자 조사시설의 중성자 파고 스펙트럼을 측정하였다. 또한, 중성자 검출효율을 증가시킬 수 있는 방법 중 하나인 다층 박막을 이용한 중성자 측정 방법을 이용하여 박막 층수에 따른 중성자 검출효율의 변화를 몬테칼로 전산모사 기법을 이용하여 계산하였고 실험을 통해 박막층의 증가에 따른 신호변화를 측정하였다.

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF

Nd:YAG 레이저 조사와 불화물 도포가 탈회법랑질의 재광화에 미치는 영향 (EFFECTS OF ND:YAG LASER IRRADIATION AND FLUORIDE APPLICATION ON REMINERALIZATION OF THE ENAMEL)

  • 조현;김대업;이광희
    • 대한소아치과학회지
    • /
    • 제31권3호
    • /
    • pp.381-390
    • /
    • 2004
  • Normal pulsed Nd:YAG 레이저 조사와 불소화합물이 산성음료수에 의해 탈회된 법랑질의 표면 미세경도에 미치는 재광화 효과를 평가하고자 한다. 법랑질 시편을 제작하여 50ml 플라스틱 시험관 5개에 코카콜라를 채운 후 30개의 소구치를 6개씩 나누어 넣고 탈회시켰다. 법랑질 표면에 6W 출력하의 50mJ 에너지 밀도, 20Hz의 pulse rate로 레이저를 조사하였다. 레이저가 조사된 법랑질 표면에 각 군별로, 여러 형태의 불소화합물을 처리한 후 탈회 전, 후의 미세경도 및 Diagnodent를 측정하였다. 동일한 방법으로 탈회된 법랑질에 레이저를 조사했을 때와 레이저가 조사된 법랑질 표면에 불소화합물을 처치한 후에 미세경도 및 Diagnodent를 측정하였다. 법랑질 표면을 산성 음료에 탈회 후, 레이저 조사 후, 불소화합물 처치 후의 각각의 시편에 대하여, 주사전자현미경으로 1500배 확대하여 관찰하였다. 1. 산성 탈회된 법랑질 표면의 미세경도(VHN)가 레이저를 조사한 후와 불소 도포 후에 증가하였으나, 레이저 조사 후의 경도와 불소도포후의 경도간의 차이는 유의하지 않았다. 2. 초기 경도, 탈회 후 경도, 레이저 조사 후 경도, 불소 도포 후 경도에서 불소군 간의 차이는 모두 유의하지 않았고, 불소용액 군과 불소 젤 군에서는 레이저 조사 후의 경도와 불소 도포 후의 경도간에 유의한 차이가 없었으나, 불소 바니쉬 군에서는 유의한 차이가 있었다. 3. Diagnodent 측정치의 변화에서 초기 점수, 탈회 후 점수, 레이저 조사 후의 점수와 불소 도포 후의 점수간에는 유의한 차이가 있었고, 레이저 조사 후 점수와 불소 도포 후의 점수가 불소 도포 군 사이에서는 유의한 차이가 없었다. 4. 산성 음료수에 탈회된 법랑질 표면에의 Nd:YAG 레이저 조사는 재광화에 효과적이며, 불소화합물의 처치는 레이저의 효과를 증가시키는 부가적인 효과를 갖는다. 5. 주사 전자 현미경상에서 Nd:YAG 레이저가 조사된 법랑질 표면은 전체 표면이 법랑소주가 녹아내려 융합된 매끈한 바닥에 균열이 생기고 분화구가 퍼져 있는 양상을 보였으며 불소 도포 후에는 균열과 분화구 형태는 뚜렷하지 않으며 탈회된 후의 표면에 가까운 양상을 보였다.

  • PDF