• Title/Summary/Keyword: Pulse Doppler

Search Result 125, Processing Time 0.023 seconds

CROSS-INTERFEROMETRY FOR DEM CONSTRUNTION WITH ERS-ENVISAT PAIR

  • Hong Sang-Hoon;Won Joong-Sun
    • Proceedings of the KSRS Conference
    • /
    • 2005.10a
    • /
    • pp.542-545
    • /
    • 2005
  • Spaceborne radar interferometry has been widely used to estimate the topography and deformation of the Earth. It is difficult to obtain coherent interferometric SAR pairs especially over coastal areas mainly because of variation of surface conditions. We carried out the experiment using a cross-interferometric pair with a perpendicular baseline of about 1.4 km, a 30 minutes temporal separation and the height sensitivity of about 6 meters. The temporal decorrelation can be reduced by the cross interferometric technique with a 30 minutes temporal separation. Accurate coregistration was performed through resampling of ENVISAT ASAR data to equivalent pixel spacing to the ERS SAR data, because of the differences of the pulse repetition frequency and range sampling rate between the two sensors. Then we estimated range and azimuth offset to a sub-pixel accuracy using image intensity cross correlation. A larger window chip size than a general case was used because it was difficult to distinguish typical features. As range bin increased, the difference of Doppler centroid also increased. It resulted in lower coherence in far range than in near range. Coherences over wetland in near and far range were about 0.8 and 0.5, respectively. The coherence was improved by applying azimuth and range common band filtering, but coherence gap still existed. ERS-ENVISAT cross-interferogram usually lost information in urban area. However, high coherence over a city in this pair was shown, because of less man-made structures than other major cities. Accuracy of the DEM constructed by the ERS-ENVISAT 30-minute pair in a coastal area is to be evaluated.

  • PDF

A Study on Analysis of Beat Spectra in a Radar System (레이다 시스템에서의 비트 스펙트럼 분석에 관한 연구)

  • Lee, Jong-Gil
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.10
    • /
    • pp.2187-2193
    • /
    • 2010
  • A specific radar system can be implemented more easily using the frequency modulated continuous wave comparing with the pulse Doppler radar. It also has the advantage of LPI (low probability of interception) because of the low power and wide bandwidth characteristics. These radars are usually used to cover the short range area and to obtain the high resolution measurements of the target range and velocity information. The transmitted waveform is used in the mixer to demodulate the received echo signal and the resulting beat signal can be obtained. This beat signal is analyzed using the FFT method for the purpose of clutter removal, detection of a target, extraction of velocity and range information, etc. However, for the case of short signal acquisition time, this FFT method can cause the serious leakage effect which disables the detection of weaker echo signals masked by strong side lobes of the clutter. Therefore, in this paper, the weighting window method is analyzed to suppress the strong side lobes while maintaining the proper main lobe width. Also, the results of FFT beat spectrum analysis are shown under various environments.

Microvascular Anastomosis of Hepatic Artery in Children Undergoing Liver Transplantation (소아 간이식에서 간동맥의 미세혈관 문합술)

  • Jin, Ung Sik;Chang, Hak;Minn, Kyung Won;Yi, Nam Joon;Suh, Kyung Suk
    • Archives of Plastic Surgery
    • /
    • v.33 no.4
    • /
    • pp.454-457
    • /
    • 2006
  • Purpose: The anastomosis of hepatic artery to recipient vessel has a major role in a liver transplantation, so its occlusion is the most important cause of failure of liver transplantations. We made the study to reveal the peculiarities in pediatric liver transplantations compared with adult cases. Methods: From January 1999 to September 2005, we performed 99 cases of pediatric liver transplantation. The mean age at operation was 4.17 years of age. The hepatic vein and portal vein are anastomosed by the general surgeons and then the hepatic artery is anastomosed by the plastic surgeons. The Doppler ultrasonography and computed tomography were used for postoperative checkup for hepatic artery patency. Results: There were no immediate complications, but hepatic arterial occlusion was developed in 3 cases (2.8%). In pediatric patients, the anastomosis of hepatic artery is more difficult than adults because of the rapid respiratory and pulse rate, the small vascular diameter, and the large gap of diameter difference between the recipient and the donor vessels. Conclusion: We could confirm that pediatric liver transplantations are relatively safe but long learning curve was needed.

Analysis of Performance for Entropy-Based ISAR Autofocus Technique (엔트로피 기반의 ISAR 자동 초점 기법에 대한 성능 분석)

  • Bae, Jun-Woo;Kim, Kyung-Tae;Lee, Jin-Ho;Im, Jeong-Heom
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.17 no.12 s.115
    • /
    • pp.1249-1258
    • /
    • 2006
  • Two-dimensional(2-D) radar images, namely, ISAR images from a maneuvering target include unwanted phase errors due to the target's motion. These phase errors make ISAR images to be blurred. The ISAR autofocus technique is required in order to remove these unwanted phase errors. Unless those unwanted phase errors produced by the target's motion are removed prior to target identification, we cannot expect a reliable target identification performance. In this paper, we use the entropy-based ISAR autofocus technique which consists of two steps: range alignment and phase adjustment. We analyze a relationship between the number of sampling point and a image quality in a range alignment algorithm and also analyze a technique for reducing computation time of the SSA(Stage-by-Stage Approachng) algorithm in a phase adjustment.

The Effects of Local Anesthetic Agent and Epinephrine on Blood Flow of Femoral Artery in Rabbit (가토에서 국소 마취제와 Epinephrine이 대퇴동맥이 혈류에 미치는 영향)

  • Oh, Soo-Won;Koo, Gil-Hoi;Lee, Choon-Hi
    • The Korean Journal of Pain
    • /
    • v.9 no.1
    • /
    • pp.46-56
    • /
    • 1996
  • Many surgeons and anesthesiologists prefer using vasoconstrictor mixed with local anesthetic agent to reduce the incidence of side effects and prolong the duration of analgesia because most local anesthetic agents, except cocaine, were believed to possess vasodilating effect. However, some investigators recently reported vasoconstricting effect of local anesthetic agents. There is still controversy on the vasoactive effect of local anesthetic agents. So this study is aimed to clarify the vasoactive effect of local anesthetics in the animal model resembling clinical settings. Rabbits were anesthesized with ketamine and haloghane, and respirations were controlled with Harvard animal ventilator. Lidocaine (0.5%, 1.0%, 1.5%) and bupivacaine (0.125%, 0.25% and 0.5%) with or without 1:100,000 epinephrine were subdermaly injected on the femoral bupivacaine of the femoral artery were measured with Doppler flow meter in vivo. The mean arterial pressure, pulse rate, arterial blood gases, pH and level of serum electrolytes were measured at every 2 minute interval for 30 minutes. Results were as follows: 1) There was no significant vasoconstriction with 0.5% lidocaine and 0.125% bupivacaine. 2) Statistically significant (p<0.05) vasodilations were observed with lidocaine (1.0~2.0%) and bupivacaine (0.25~0.5%). 3) There were no changes on the duration of vasodilation induced by local anesthetic agents of various concentrations. 4) Onset of vasodilation induced by local anesthetic agents of high concentration were faster than that of lower concentrations. 5) In the mixed injection group of epinephrine and local anesthetic agent, the vasoconstriction induced by epinephrine was completely reversed by local anesthetics, approximately 5 minutes later. In conclusion, local anesthetic agents at dose exceeding 1.0% lidocaine and 0.25% bupivacaine increase local blood flow significantly in animal study in vivo which is applicable in human clinical settings. The increase blood flow may be due to dilatation of blood vessel. Further study on the analysis of association between amount of absorbed local anesthetics in blood vessels and dilatation of blood vessels is needed.

  • PDF

Treatment of Experimental Hydronephrosis Using Renal Artery Embolization and Sclerotherapy in Beagle Dogs (신동맥색전술과 신우경화술을 이용한 비글견의 실험적 수신증 치료)

  • Chang Dong-woo;Lee Young-won;Shin Sang-tae
    • Journal of Veterinary Clinics
    • /
    • v.22 no.2
    • /
    • pp.119-124
    • /
    • 2005
  • This study was performed to validate the procedure of transarterial embolization of the renal artery (TAE-RA) and sclerotherapy of renal pelvis using iohexol-ethanol solution in dogs with unilateral experimental hydronephrosis. Experimental hydronephrosis was induced by unilateral ureter ligation for 20 days in five Beagle dogs. Renal artery embolization with iohexol-ethanol solution was performed using selective catheterization technique in the hydronephrotic kidney and sclerotherapy was done by injection of the iohexol-ethanol solution through percutaneously placed pig-tail catheter. EKG, $SpO_2$ body temperature, pulse, and respiratory rate were within normal ranges during procedures. Average pure ethanol dose for renal artery embolization was $1.1\pm0.3ml/kg$. Renal artery embolization was confirmed by the detection of no blood flow signal at the interlobar and arcuate artery using color Doppler ultrasonography. There were no dogs expired after TAE-RA and sclerotherapy and no side effects associated with regurgitation of iohexol-ethanol solution. The value of BUN, creatinine, ALT, AST, Ca, P in five dogs were within normal range during the experiment period. Ultrasonographically, the mean longitudinal and transverse length and the depth of the embolized kidney significantly decreased at 28 days after TAE-RA. We may conclude that TAE-RA and sclerotherapy with iohexol-ethanol solution is an effective methods for the treatment of unilateral hydronephrosis in dogs.

MOving Spread Target signal simulation (능동 표적신호 합성)

  • Seong, Nak-Jin;Kim, Jea-Soo;Lee, Snag-Young;Kim, Kang
    • The Journal of the Acoustical Society of Korea
    • /
    • v.13 no.2
    • /
    • pp.30-37
    • /
    • 1994
  • Since the morden targets are of high speed and getting quiet in both active and passive mode, the necessities of developing advanced SONAR system capable of performing target motion analysis (TMA) and target classification are evident. In order to develop such a system, the scattering mechanism of complex bodies needs to be, some extent, fully understood and modeled. In this paper, MOving Spread Target(MOST) signal simulation model is presented and discussed. The model is based on the highlight distribution method, and simulates pulse elongation of spread target, doppler effect due to kinematics of the target as well as SONAR platform, and distribution target strength of each highlight point (HL) with directivity. The model can be used in developing and evaluating advanced SONAR system through system simulation, and can also be used in the development of target state estimation algorithm.

  • PDF

A Development of the X-Band 63 Watt Pulsed SSPA for Radar (레이더용 X-대역 63 Watt Pulsed SSPA 개발)

  • Chong, Min-Kil;Na, Hyung-Gi
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.3
    • /
    • pp.380-388
    • /
    • 2011
  • In this paper, we developed the X-band 63 watt pulsed SSPA(Solid State Power Amplifier) by using HMIC(Hybrid Microwave Integrated Circuits). The pulsed SSPA consists of power supply and 3-stage amplifier modules : pre-amplifier stage, driver-amplifier stage, final-amplifier stage. The developed pulsed SSPA provides more than 63 watts of output power with a short pulse width and the duty cycle of up to 1.2 % at $70^{\circ}C$. The fabricated module offers great than 37 dB of saturated gain across the operating band. Input and output VSWR is <1.5:1. This module has an average current of 400 mA typical and operates at a +28 $V_{dc}$ supply. The developed SSPA in this paper can apply to pulsed Doppler radar with high speed operation.

Efficient Detection of Small Unmanned Aerial Vehicles in Cluttered Environment (클러터 환경을 고려한 효과적 소형 무인기 탐지에 관한 연구)

  • Choi, Jae-Ho;Kang, Ki-Bong;Sun, Sun-Gu;Lee, Jung-Soo;Cho, Byung-Lae;Kim, Kyung-Tae
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.30 no.5
    • /
    • pp.389-398
    • /
    • 2019
  • In this paper, we propose a method to detect small unmanned aerial vehicles(UAVs) flying in a real-world environment. Small UAV signals are frequently obscured by clutter signals because UAVs usually fly at low altitudes over urban or mountainous terrain. Therefore, to obtain a desirable detection performance, clutter signals must be considered in addition to noise, and thus, a performance analysis of each clutter removal technique is required. The proposed detection process uses clutter removal and pulse integration methods to suppress clutter and noise signals, and then detects small UAVs by utilizing a constant false alarm rate detector. After applying three clutter removal techniques, we analyzed the performance of each technique in detecting small UAVs. Based on experimental data acquired in a real-world outdoor environment, we found it was possible to derive a clutter removal method suitable for the detection of small UAVs.

An intelligent method for pregnancy diagnosis in breeding sows according to ultrasonography algorithms

  • Jung-woo Chae;Yo-han Choi;Jeong-nam Lee;Hyun-ju Park;Yong-dae Jeong;Eun-seok Cho;Young-sin, Kim;Tae-kyeong Kim;Soo-jin Sa;Hyun-chong Cho
    • Journal of Animal Science and Technology
    • /
    • v.65 no.2
    • /
    • pp.365-376
    • /
    • 2023
  • Pig breeding management directly contributes to the profitability of pig farms, and pregnancy diagnosis is an important factor in breeding management. Therefore, the need to diagnose pregnancy in sows is emphasized, and various studies have been conducted in this area. We propose a computer-aided diagnosis system to assist livestock farmers to diagnose sow pregnancy through ultrasound. Methods for diagnosing pregnancy in sows through ultrasound include the Doppler method, which measures the heart rate and pulse status, and the echo method, which diagnoses by amplitude depth technique. We propose a method that uses deep learning algorithms on ultrasonography, which is part of the echo method. As deep learning-based classification algorithms, Inception-v4, Xception, and EfficientNetV2 were used and compared to find the optimal algorithm for pregnancy diagnosis in sows. Gaussian and speckle noises were added to the ultrasound images according to the characteristics of the ultrasonography, which is easily affected by noise from the surrounding environments. Both the original and noise added ultrasound images of sows were tested together to determine the suitability of the proposed method on farms. The pregnancy diagnosis performance on the original ultrasound images achieved 0.99 in accuracy in the highest case and on the ultrasound images with noises, the performance achieved 0.98 in accuracy. The diagnosis performance achieved 0.96 in accuracy even when the intensity of noise was strong, proving its robustness against noise.