• 제목/요약/키워드: Pulse Delay Time

검색결과 189건 처리시간 0.026초

고속 고분해 테라헤르츠 시간영역 분광기 (High-Speed High-Resolution Terahertz Time-Domain Spectrometer)

  • 김영찬;김기복;이대수;이민우;안재욱
    • 한국광학회지
    • /
    • 제19권5호
    • /
    • pp.370-375
    • /
    • 2008
  • 본 논문에서 비동시성 광샘플링(asynchronous optical sampling; AOS) 방식을 이용하는 고속 고분해 테라헤르츠 시간영역 분광(terahertz time domain spectroscopy; THz-TDS)을 시연한다. 모터로 구동되는 선형 스테이지를 사용하지 않고, 약간 다른 반복 주파수를 갖는 두 대의 펨토초 레이저를 각각 테라헤르츠파 발생과 검출에 사용하여 고속으로 10 ns의 시간축 상의 신호를 획득하고 fast Fourier transformation(FFT)을 통하여 100 MHz의 주파수 분해능을 갖는 고분해 분광을 구현한다. Cross-correlation 방법에 의해 시간 분해능은 278 fs으로 측정되었다. 또한, 본 분광기를 이용하여 수증기의 투과 스펙트럼을 측정하고 흡수선들을 분석하였다.

초음파센서를 이용한 변량제어 스프레이어 (Ultrasonic Sensor Controlled Sprayer for Variable Rate Liner Applications)

  • 전홍영;주허핑
    • Journal of Biosystems Engineering
    • /
    • 제36권1호
    • /
    • pp.15-22
    • /
    • 2011
  • An experimental variable rate nursery sprayer was developed to adjust application rates for canopy volume in real time. The sprayer consisted of two vertical booms integrated with ultrasonic sensors, and variable rate nozzles coupled with pulse width modulation (PMW) based solenoid valves. A custom-designed microcontroller instructed the sensors to detect canopy size and occurrence and then controlled nozzles to achieve variable application rates. A spray delivery system, which consisted of diaphragm pump, pressure regulator and 4-cycle gasoline engine, offered the spray discharge function. Spray delay time, time adjustment in spray trigger for the leading distance of the sensor, was measured with a high-speed camera, and it was from 50 to 140 ms earlier than the desired time (398 ms) at 3.2 km/h under indoor conditions. Consequently, the sprayer triggered 4.5 to 12.5 cm prior to detected targets. Duty cycles of the sprayer were from 20 to 34 ms for senor-to-canopy (STC) distance from 0.30 to 0.76 m. Outdoor test confirmed that the nozzles were triggered from 290 to 380 ms after detecting tree canopy at 3.2 km/h. The spray rate of the new sprayer was 58.4 to 85.2% of the constant application rate (935 L/ha). Spray coverage was collected at four areas of evergreen canopy by water sensitive papers (WSP), and ranged from 1.9 to 41.1% and 1.8 to 34.7% for variable and constant rate applications, respectively. One WSP area had significant (P < 0.05) difference in mean spray coverage between two application conditions.

레이저유도 플라즈마분광법을 이용한 방사성폐기물 유리의 현장분석 시스템 개발 (Development of in-situ Analysis System for Radwaste Glass Using Laser Induced Breakdown Spectroscopy)

  • 김천우;박종길;신상운;하종현;송명재;이계호
    • 한국방사성폐기물학회:학술대회논문집
    • /
    • 한국방사성폐기물학회 2004년도 학술논문집
    • /
    • pp.137-146
    • /
    • 2004
  • 방사성폐기물 유리화 공전 중 용융로 내에서 유리시료를 직접분석 하기 위한 레이저유도 플라즈마분광법(LIBS: Laser Induced Breakdown Spectroscopy)을 개발 중이다. LIBS 시스템을 구성하기 위하여 분광기, 검출기, 레이저 등의 장비들을 구축하였다. 분광기는 CCD(charge coupled device)가 보정되어 내장되어있는 ESA 3000을 레이저는 Q-switched Nd-YAG인 Brilliant로 구매하여 분석시스템을 구축하였다. 구축된 분석시스템 분야별 성능들을 확인하였으며 최적화 연구를 수행하였다. 첫 번째 단계로 Fe가 함유된 시료에 레이저를 주사하였을 때 발광스펙트럼을 측정하였으며 검출기의 지연시간을 변화시켰을 때의 발광스펙트럼의 특성과 이를 이용한 여기온도를 Einstein-Boltzmann 식을 이용하여 계산하였다. 시료에 532nm Nd-YAG 레이저를 주사하고 검출기의 지연시간을 500, 1000, 1500, 2000ns로 변화시켰을 때의 분광선의 intensity 및 여기온도 변화를 분석하였다. 그 결과 검출시간이 1500㎱ 일 때 여기온도는 7820k로 가장 최적의 상태를 확인하였다. 향후 이 시스템은 유리화 실증시설에 적용되어 용융로 외부로의 유리시료 이송 없이 현장에서 유리성분들의 정량분석을 수행할 예정이다.

  • PDF

멤리스터의 전기적 특성 분석을 위한 PSPICE 회로 해석 (PSPICE circuit simulation for electrical characteristic analysis of the memristor)

  • 김부강;박호종;박용수;송한정
    • 한국산학기술학회논문지
    • /
    • 제15권2호
    • /
    • pp.1051-1058
    • /
    • 2014
  • 본 논문에서는 PSPICE 프로그램을 이용하여 멤리스터 소자의 전기적 특성을 해석하였다. 멤리스터의 PSPCE 회로해석을 위한 모델링을 제안하고, 멤리스터의 전류-전압 특성을 분석하였고, 멤리스터의 입력전압에 따른 비선형 저항의 변화를 DC해석과 과도해석을 통하여 확인하였다. 또한, 멤리스터 저항의 직렬과 병렬연결에 따른 특성변화를 보았다. 한편, 멤리스터와 커패시터로 이루어진 M-C 회로를 구성하여 충전과 방전특성의 변화를 종래의 R-C회로와 비교분석하였다. 250 Hz의 구형파 입력신호 인가 시, 멤리스터-커패시터 회로의 경우에, 상승시간(Tr) 0.58 ms, 하강 시간 (Tf) 1.6 ms, 지연시간 0.6ms를 나타내었다.

T-방식과 M-방식을 이용한 저궤도위성용 반작용 휠의 속도측정보드 설계 (The Implementation of the Speed Measurement Board for the Reaction Wheel on the LEO Satellite using the T, M-Method)

  • 이재녕;박성훈;허수진;이윤기
    • 한국항공우주학회지
    • /
    • 제40권9호
    • /
    • pp.827-832
    • /
    • 2012
  • 본 논문에서는 저궤도 위성의 반작용 휠 속도 측정을 위해 M-방식과 T-방식 모두 검출가능한 보드를 설계하여 두 방식의 장점을 이용할 수 있도록 하고, 실제 위성탑재컴퓨터에 장착하여 시험을 수행하고 이를 통하여 그 설계의 유용성을 검증한다. 위성에서 반작용 휠은 위성의 자세를 변화시킬 수 있는 대표적인 구동기의 하나로 반작용 휠 구동모터의 회전에 의해 발생하는 회전관성에 의해 자세 제어를 수행하게 된다. 반작용 휠의 회전속도를 검출하는 방법으로는 일정한 주기 T 동안 발생된 반작용 휠 내부 타코 펄스를 세어 휠의 속도를 검출하는 M-방식과 휠에서 발생되는 타코 펄스들 간의 시간을 측정해서 속도를 검출하는 T-방식으로 나눌 수 있다. M-방식은 구현이 간단하고 측정 시간이 일정하다는 장점이 있으나, 저속에서는 속도 측정 분해능이 떨어진다는 단점이 있다. 그에 반해, 타코 펄스간의 시간을 측정하는 T-방식은 저속에서 정밀한 속도를 측정할 수 있으며 측정에 따른 시간 지연이 작다는 장점이 있다. 그러나 이 방법 역시 실제 구현에 있어서 연산이 복잡하고 속도에 따라 연산 속도가 달라진다는 단점이 있다.

초음파 다이나믹 집속 시스템의 설계 (Design of Ultrasound Dynamic Focusing Systems)

  • 김진하;김청월
    • 대한전자공학회논문지
    • /
    • 제21권4호
    • /
    • pp.65-71
    • /
    • 1984
  • 초음파 B스캔너의 경우 광대역 펄스를 사용하기 때문에 광학에서 사용되는 집속 계산식으로는 초음파 집속 시스템을 정확하게 설계할 수 없다. 본 연구에서는 초음파 다중소자에 광대역 펄스가 여기될 때 초음파의 전파모양을 정확하게 계산할 수 있늘 방법이 연구되었다. 계간된 초음차의 전파 모양을 이용하여 고해상력을 갖는 다이나믹 집속(dynamic focusing)시스템의 구동소자수, 집속치로 지연값 및 집속점 위치등을 설계하도록 하였다. 저잡음 스튀칭 특성을 갖는 다이나믹 집속 시스템을 구성하여 실험에 의해 3.5MHz선형소자로써 18cm의 깊이까지 2∼3mm의 해상도가 얻어짐을 확인하였다.

  • PDF

Kinetic Study on the Low-lying Excited States of Ga Atoms in Ar

  • Kuntack Lee;Ju Seon Goo;Ja Kang Ku
    • Bulletin of the Korean Chemical Society
    • /
    • 제15권8호
    • /
    • pp.663-669
    • /
    • 1994
  • Decay kinetics of Ga(5s), Ga(5p) and Ga(4d) atoms in Ar were studied by laser induced fluorescence technique. Theground state gallium atoms in the gas phase were generated by pulsed dc discharge of trimethyl gallium and argon mixtures. Both pulsed discharge and YAG-DYE laser system were controlled by a dual channel pulse generator and the delay time between the end of discharge and laser pulses was set 3.0-6.0 ms. The Ga(5s) and Ga(4d) atoms were generated by single photon excitation from the ground state Ga atoms and radiative lifetimes as well as the total quenching rate constants in Ar were obtained from the pressure dependence of the fluorescence decay rates. The Ga(5p) atoms were populated by a two-photon excitation method and the cascade fluorescence from Ga(5s) atoms were analyzed to extract quenching rate constant of Ga(5p) atoms by Ar in addition to radiative lifetimes of Ga(5p) state. The magnitudes of the quenching rate constants by Ar for the low-lying excited states of Ga atoms are 1.6-3$ {\times}10^{-11}cm^3$ molecul$e^{-1}s^{-1}$, which are much larger than those for alkali, alkaline earth and Group 12 metals. Based on the measured rate constants, kinetic simulations were done to assign state-to-state rate constants.

Assessment of the Purity of Emodin by Quantitative Nuclear Magnetic Resonance Spectroscopy and Mass Balance

  • Park, Sojung;Choi, Yu-Jin;Do, Giang Hoang;Seo, Eun Kyoung;Hyun, Seunghun;Lee, Dongho
    • Natural Product Sciences
    • /
    • 제25권3호
    • /
    • pp.222-227
    • /
    • 2019
  • Quantitative nuclear magnetic resonance (qNMR) is a well-established method adopted by international pharmacopoeia for quantitative and purity analyses. Emodin is a type of anthraquinone, well known as the main active component of Fabaceae, Polygonaceae and Rhamnaceae. Purity analysis of emodin is usually performed by using the high-performance liquid chromatography (HPLC)-UV method. However, it cannot detect impurities such as salts, volatile matter, and trace elements. Using the qNMR method, it is possible to determine the compound content as well as the nature of the impurities. Several experimental parameters were optimized for the quantification, such as relaxation delay, spectral width, number of scans, temperature, pulse width, and acquisition time. The method was validated, and the results of the qNMR method were compared with those obtained by the HPLC and mass balance analysis methods. The qNMR method is specific, rapid, simple, and therefore, a valuable and reliable method for the purity analysis of emodin.

Reinforcing effect of CFRP bar on concrete splitting behavior of headed stud shear connectors

  • Huawen Ye;Wenchao Wang;Ao Huang;Zhengyuan Wang
    • Steel and Composite Structures
    • /
    • 제48권2호
    • /
    • pp.131-143
    • /
    • 2023
  • The CFRP bar was used to achieve more ductile and durable headed-stud shear connectors in composite components. Three series of push-out tests were firstly conducted, including specimens reinforced with pure steel fibers, steel and CFRP bars. The distributed stress was measured by the commercial PPP-BOTDA (Pre-Pump-Pulse Brillouin optical time domain analysis) optical fiber sensor with high spatial resolution. A series of numerical analyses using non-linear FE models were also made to study the shear force transfer mechanism and crack response based on the test results. Test results show that the CFRP bar increases the shear strength and stiffness of the large diameter headed-stud shear connection, and it has equivalent reinforcing effects on the stud shear capacity as the commonly used steel bar. The embedded CFRP bar can also largely improve the shear force transfer mechanism and decrease the tensile stress in the transverse direction. The parametric study shows that low content steel fibers could delay the crack initiation of slab around the large diameter stud, and the CFRP bar with normal elastic modulus and the standard reinforcement ratio has good resistance to splitting crack growth in headed stud shear connectors.

최적화된 Flip Angle Pattern을 사용한 Turbo FLASH MRI: Inversion-Recovery T1-Weighted Imaging에의 응용 (Turbo FLASH NRI Using Optimized Flip Angle Pattern: Application to Inversion-Recovery T1-Weighted Imaging)

  • 오창현;최환준;양윤정;이덕래;류연철;현정호;김사라;이윤;정관진;안창범
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1998년도 추계학술대회
    • /
    • pp.55-56
    • /
    • 1998
  • The 3-D Fast Gradient Echo (Turbo FLASH, Turbo Fast Low Angle Shot) sequence is optimized to achieve a good T1 contrast using variable excitation flip angles. In Turbo FLASH sequence, depending on the contrast preparation scheme, various types of image contrast can be established. While proton density contrast is obtained when using a short repetition time with a short echo time and small flip angles, T1 or T2 weighting can be obtained with proper contrast preparation sequences applied before the above proton density Turbo FLASH sequence. To maximize the contrast to noise ratio while retaining a sharp impulse response (smooth frequency domain response), the excitation flip-angle pattern is optimized through simulation and experiments. The TI (the delay after the preparation sequence which is a 180 degree inversion RF pulse in the IR T1 weighted imaging case), TD (the delay time between the Turbo FLASH sequence and the next preparation), and TR are also optimized fur the best image quality. The proposed 3-D Turbo FLASH provides $1mm\times1mm\times1.5mm$ high resolution images within a reasonable 5-8 minutes of imaging time. The proposed imaging sequence has been implemented in a Medison's Magnum 1.0T system and verified through simulations as well as human volunteer imaging. The experimental results show the utility of the proposed method.

  • PDF