• Title/Summary/Keyword: Pulse Analysis

Search Result 2,086, Processing Time 0.034 seconds

SVC Based Multi-channel Transmission of High Definition Multimedia and Its Improved Service Efficiency (SVC 적용에 의한 다매체 멀티미디어 지원 서비스 효율 향상 기법)

  • Kim, Dong-Hwan;Cho, Min-Kyu;Moon, Seong-Pil;Lee, Jae-Yeal;Jun, Jun-Gil;Chang, Tae-Gyu
    • Journal of IKEEE
    • /
    • v.15 no.2
    • /
    • pp.179-189
    • /
    • 2011
  • This paper presents an SVC based multi-channel transmission technique. Transmission of high definition multimedia and its service efficiency can be significantly improved by the proposed method. In this method, the HD stream is divided into the two layer streams, i.e., a base layer stream and an enhancement layer stream. The divided streams are transmitted through a primary channel and an auxiliary channel, respectively. The proposed technique provides a noble mode switching technique which enables a seamless service of HD multimedia even under the conditions of abrupt and intermittent deterioration of the auxiliary channel. When the enhancement layer stream is disrupted by the channel monitoring in the mode switching algorithm, the algorithm works further to maintain the spatial and time resolution of the HD multimedia by upsampling and interpolating the base layer stream, consequently serving for the non disrupted play of the media. Moreover, the adoption of an adaptive switching algorithm significantly reduces the frequency of channel disruption avoiding the unnecessary switching for the short period variations of the channel. The feasibility of the proposed technique is verified through the simulation study with an example application to the simultaneous utilization of both Ku and Ka bands for HD multimedia broadcasting service. The rainfall modeling and the analysis of the satellite channel attenuation characteristics are performed to simulate the quality of service performance of the proposed HD broadcasting method. The simulation results obtained under a relatively poor channel (weather) situations show that the average lasting period of enhancement layer service is extended from 9.48[min] to 23.12[min] and the average switching frequency is reduced from 3.84[times/hour] to 1.68[times/hour]. It is verified in the satellite example that the proposed SVC based transmission technique best utilizes the Ka band channel for the service of HD broadcasting, although it is characterized by its inherent weather related poor reliability causing severe limitations in its independent application.

Quantitative Analysis of Magnetization Transfer by Phase Sensitive Method in Knee Disorder (무릎 이상에 대한 자화전이 위상감각에 의한 정량분석법)

  • Yoon, Moon-Hyun;Sung, Mi-Sook;Yin, Chang-Sik;Lee, Heung-Kyu;Choe, Bo-Young
    • Investigative Magnetic Resonance Imaging
    • /
    • v.10 no.2
    • /
    • pp.98-107
    • /
    • 2006
  • Magnetization Transfer (MT) imaging generates contrast dependent on the phenomenon of magnetization exchange between free water proton and restricted proton in macromolecules. In biological materials in knee, MT or cross-relaxation is commonly modeled using two spin pools identified by their different T2 relaxation times. Two models for cross-relaxation emphasize the role of proton chemical exchange between protons of water and exchangeable protons on macromolecules, as well as through dipole-dipole interaction between the water and macromolecule protons. The most essential tool in medical image manipulation is the ability to adjust the contrast and intensity. Thus, it is desirable to adjust the contrast and intensity of an image interactively in the real time. The proton density (PD) and T2-weighted SE MR images allow the depiction of knee structures and can demonstrate defects and gross morphologic changes. The PD- and T2-weighted images also show the cartilage internal pathology due to the more intermediate signal of the knee joint in these sequences. Suppression of fat extends the dynamic range of tissue contrast, removes chemical shift artifacts, and decreases motion-related ghost artifacts. Like fat saturation, phase sensitive methods are also based on the difference in precession frequencies of water and fat. In this study, phase sensitive methods look at the phase difference that is accumulated in time as a result of Larmor frequency differences rather than using this difference directly. Although how MT work was given with clinical evidence that leads to quantitative model for MT in tissues, the mathematical formalism used to describe the MT effect applies to explaining to evaluate knee disorder, such as anterior cruciate ligament (ACL) tear and meniscal tear. Calculation of the effect of the effect of the MT saturation is given in the magnetization transfer ratio (MTR) which is a quantitative measure of the relative decrease in signal intensity due to the MT pulse.

  • PDF

Predicting Migration of a Heavy Metal in a Sandy Soil Using Time Domain Reflectometry (TDR을 이용한 사질토양에서의 중금속 이동 추정)

  • Dong-Ju Kim;Doo-Sung Baek;Min-Soo Park
    • Journal of Korea Soil Environment Society
    • /
    • v.4 no.1
    • /
    • pp.109-118
    • /
    • 1999
  • Recently, transport parameters of conservative solutes such as KCl in a porous medium have been successfully determined using time domain reflectometry (TDR) . This study was initiated to Investigate the applicability of TDR technique to monitoring the fate of a heavy metal ion in a sandy soil and the distribution of its concentration along travel distance with time. A column test was conducted in a laboratory that consists of monitoring both resident and flux concentrations of $ZnCl_2$in a sandy soil under a breakthrough condition. A tracer of $ZnCl_2$(10 g/L) was injected onto the top surface of the sample as pulse type as soon as a steady-state condition was achieved. Time-series measurements of resistance and electrical conductivity were performed at 10 cm and 20 cm of distances from the inlet boundary by horizontal-positioning of parallel TDR metallic rods and using an EC-meter for the effluent exiting the bottom boundary respectively. In addition. Zn ions of the effluent were analyzed by ICP-AES. Since the mode and position of concentration detected by TDR and effluent were different, comparison between ICP analysis and TDR-detected concentration was made by predicting flux concentration using CDE model accommodating a decay constant with the transport parameters obtained from the resident concentrations. The experimental results showed that the resident concentration resulted in earlier and higher peak than the flux concentration obtained by EC-meter, implying the homogeneity of the packed sandy soil. A close agreement was found between the predicted from the transport parameters obtained by TDR and the measured $ZnCl_2$concentration. This indicates that TDR technique can also be applied to monitoring heavy metal concentrations in the soil once that a decay constant is obtained for a given soil.

  • PDF

Structural Analysis of Class I Integron Gene Cassette and Assessment of Genetic Relationships by PFGE of Salmonella enterica Serovar Typhimurium Isolated in Gyeongbuk Area (경북지역에서 분리된 Salmonella enterica Serovar Typhimurium의 Class I Integron Gene Cassette 특성과 PEGE 유형분석)

  • Sohn, Chang-Kyu;Lee, Jung-A;Lee, Do-Young;Hun, Wan;Jung, Jung-Kyo
    • Korean Journal of Microbiology
    • /
    • v.42 no.1
    • /
    • pp.12-18
    • /
    • 2006
  • Thirty five Salmonella enterica serovar Typhimurium strains were isolated from diarrheic patients and pigs in Gyeongbuk area from 2003 to 2004. All 35 strains (17 strains from diarrheic patients and 18 from pigs) were resistant to more than one drug and most of strains isolated from pigs were resistant to ampicillin, ohloram-phenicol, streptomycin, sulfamethoxazole-trimethoprime, tetracyclin and nalidixic acid. Each isolate was also screened or the presence of class I, II and III integron gene cassettes. Among 35 strains,3 out of 17 strains isolated from diarrheic patients, carried dhfrX-orfF-aadA2 integron gene cassette and among 18 strains isolated from diseased pigs, 11 strains carried dhfrX-orfF-aadA2 integron gene cassette and 1 strain carried aadA2 integron only. But any class II and class II integron gene cassette were not detected in 35 strains. Thirty five strains were divided by five pulsotypes. Thirty one strains out of thirty five were pulsotype A. Among the remaining 4 strains, one each strain belonged to pulsotype B, C, D and pulsotype E. This data of pulsotypes showed that the widespread of pulsotype A, Salmonella enterica serovar Typhimurium in human and pigs in Gyeongbuk area may have been caused by the dissemination of a few epidemic strains in this area. Thirteen strains contain dhfrX-orfF-aadA2 integron gene cassette showed pulsotype A and one strain contains dhfrX-orfF-aadA2 integron gene cassette showed pulsotype B. One strain contains aadA2 integron showed pulsotype E. But fifteen strains do not contain any integron showed pulsotype A.

Analysis of Experimental Researches in Korea on the Effects of Aromatherapy to Relieve Pain (아로마테라피의 통증 감소 효과에 관한 국내 실험논문 분석)

  • Park, Jeong-Sook;Park, Jeong-Eon;Yang, Jang-Soon;Kwak, Hye-Weon;Han, Jung-An
    • Journal of Hospice and Palliative Care
    • /
    • v.14 no.1
    • /
    • pp.8-19
    • /
    • 2011
  • Purpose: This study identifies research trends and provides fundamental data related to curative power of aromatherapy to relieve pain in Korea. Methods: The study analyzed 44 experimental studies on humans that were published in Korea before the end of December, 2009. The key words used for searching were: aroma, aromatherapy, hyang-yobeob, hyanggi-yobeob, hyanggichilyo, aromatherapy and pain, headache, scapulodynia, omodynia, feeling uncomfortable in the perineal region, sense of pain, labor pains, arm pain, menstrual pain, aches, and dysmenorrheal. Those words were found on websites, including those for Korea Education & Research Information Service, the National Assembly Library, KISS, KoreaMed, and NDSL. Collected data were analyzed using descriptive statistics. Results: The results showed that most of essential oils to relieve pain is composed of three to four kinds of oils, including Lavender, Roman chamomile, Rosemary, and Clarysage. Aromatherapy is applied usually by means of massage (50%), inhalation (13.6%), or a combination of the above two (13.6%). Measuring instruments as a dependent variable include VAS, questionnaire, GRS, blood pressure, pulse, and Algometer. Aromatherapy plays an important role in soothing headaches and arthralgia. However, when it comes to labor and menstrual pain, it doesn't seem to be effective. Conclusion: The study found that different kinds of oil, frequencies, and periods of time are used for the same symptoms. Further research should employ standardized oil blending, application, duration, and measuring instruments, and more systematically analyze the effects of aromatherapy to establish the effects on relieving pain.

The Effect of Low-Intensity Pulsed Ultrasound on Fracture Healing in the Rabbit Model (토끼모델에서 저강도 맥동초음파가 골절치유에 미치는 영향)

  • Kim, Jong-Man;Yi, Chung-Hwi;Cho, Sang-Hyun;Park, Jung-Mi;Kwon, Hyuk-Cheol;Hwang, Tae-Sun
    • Physical Therapy Korea
    • /
    • v.9 no.1
    • /
    • pp.81-96
    • /
    • 2002
  • The purpose of this research was to determine the effects on the healing of fibular fractures in rabbits of low-intensity pulsed ultrasound (50 $mW/cm^2$ and 500 $mW/cm^2$) applied for periods of 4, 14 and 24 days following fibular osteotomy. Thirty-six male Japanese white rabbits were randomly divided into three groups of twelve for three treatment protocols: (1) ultrasound treatment at intensities of 50 $mW/cm^2$ and 500 $mW/cm^2$ until the 4th day following fibular osteotomy, (2) ultrasound treatment at intensities of 50 $mW/cm^2$ and 500 $mW/cm^2$ until the 14th day following fibular osteotomy, and (3) ultrasound treatment at intensities of 50 $mW/cm^2$ and 500 $mW/cm^2$ until the 24th day following fibular osteotomy. The low-intensity pulsed ultrasound was applied to only one fibula of each rabbit (these served as the experimental group). The other fibula of each rabbit served as the control group. The selection of which fibula was to be treated was made randomly. The animals were sacrificed on the 4th, 14th and 24th day after the start of ultrasound treatments. Percent of trabecular bone area and fibular radiography were carried out to compare the degree of fibular bone healing. A microscope was also used to determine any histologic changes. For statistical differences in radiological changes due to length of treatment period (4, 14 and 24 days respectively), the Wilcoxon signed-ranks test was used to compare the experimental and control groups. For statistical differences in fracture healing due to differences in ultrasound intensity, radiological studies were compared using the Mann-Whitney Test. And, to compute percentage differences in areas of trabecular bone, Two-way analysis of variance (ultrasound intensity x each group) was used. Experiment results were as follows: 1. In animals sacrificed on the 4th day, no difference was found in the radiological studies of the fibulae in the experimental and control groups (p>.05). However, experimental groups showed more rapid bone repair than control group. 2. Both radiographic and percent of trabecular bone area studies showed significant differences in rabbits sacrificed after 14 days. Fracture healing was significantly increased in the experimental group (p<.05) 3. In the animals sacrificed on the 24th day, histologic study showed rapid bone repair but fibular radiologic studies did not show statistical differences between the two groups (p>.05). 4. On the 14th day, bone union on radiograph was significantly more rapid in the treatment group with pulsed ultrasound of 50 $mW/cm^2$ than the group with 500 $mW/cm^2$ (p<.05). Histologic studies showed that both the 14 and 24 days groups had more rapid bone repair in animals treated with 50 $mW/cm^2$ ultrasound intensity than those treated with 500 $mW/cm^2$ intensity. In conclusion, it has been shown that the low-intensity pulsed ultrasound has a positive effect on bone fracture healing in the early stage and the range of pulse ultrasound from 50 $mW/cm^2$ to 500 $mW/cm^2$ is effective for fracture healing. Further study is needed to investigate the influence of pulsed ultrasound on delayed union and non-union in bone fractures and also for the clinical use of low-intensity pulsed ultrasound for bone healing in humans.

  • PDF

Status of Agrometeorological Information and Dissemination Networks (농업기상 정보 및 배분 네트워크 현황)

  • Jagtap, Shrikant;Li, Chunqiang
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.6 no.2
    • /
    • pp.71-84
    • /
    • 2004
  • There is a growing demand for agrometeorological information that end-users can use and not just interesting information. lo achieve this, each region/community needs to develop and provide localized climate and weather information for growers. Additionally, provide tools to help local users interpret climate forecasts issued by the National Weather Service in the country. Real time information should be provided for farmers, including some basic data. An ideal agrometeorological information system includes several components: an efficient data measuring and collection system; a modern telecommunication system; a standard data management processing and analysis system; and an advanced technological information dissemination system. While it is conventional wisdom that, Internet is and will play a major role in the delivery and dissemination of agrometeorological information, there are large gaps between the "information rich" and the "information poor" countries. Rural communities represent the "last mile of connectivity". For some time to come, TV broadcast, radio, phone, newspaper and fax will be used in many countries for communication. The differences in achieving this among countries arise from the human and financial resources available to implement this information and the methods of information dissemination. These differences must be considered in designing any information dissemination system. Experience shows that easy across to information more tailored to user needs would substantially increase use of climate information. Opportunities remain unexplored for applications of geographical information systems and remote sensing in agro meteorology.e sensing in agro meteorology.

Rainfall and Hydrological Comparative Analysis of Water Quality Variability in Euiam Reservoir, the North-Han River, Korea (북한강 의암호의 수질 변동성에 대한 강우·수문학적 비교분석)

  • Hwang, Soon-Jin;Sim, Yeon Bo;Choi, Bong-Geun;Kim, Keonhee;Park, Chaehong;Seo, Wanbum;Park, Myung-Hwan;Lee, Su-Woong;Shin, Jae-Ki
    • Korean Journal of Ecology and Environment
    • /
    • v.50 no.1
    • /
    • pp.29-45
    • /
    • 2017
  • This study explored spatiotemporal variability of water quality in correspondence with hydro-meteorological factors in the four stations of Euiam Reservoir located in the upstream region of the North-Han River from May 2012 to December 2015. Seasonal effect was apparent in the variation of water temperature, DO, electric conductivity and TSS during the study period. Stratification in the water column was observed in the near dam site every year and vanished between August and October. Increase of nitrogen nutrients was observed when inflowing discharge was low, while phosphorus increase was distinct both during the early season with increase of inflowing discharge and the period of severe draught persistent. Duration persisting high concentration of Chl-a (>$25mg\;m^{-3}$: the eutrophic status criterion, OECD, 1982) was 1~2 months of the whole year in 2014~2015, while it was almost 4 months in 2013. Water quality of Euiam Reservoir appeared to be affected basically by geomorphology and source of pollutants, such as longitudinally linked instream islands and Aggregate Island, inflowing urban stream, and wastewater treatment plant discharge. While inflowing discharge from the dams upstream and outflow pattern causing water level change seem to largely govern the variability of water quality in this particular system. In the process of spatiotemporal water quality change, factors related to climate (e.g. flood, typhoon, abruptly high rainfall, scorching heat of summer), hydrology (amount of flow and water level) might be attributed to water pulse, dilution, backflow, uptake, and sedimentation. This study showed that change of water quality in Euiam Reservoir was very dynamic and suggested that its effect could be delivered to downstream (Cheongpyeong and Paldang Reservoirs) through year-round discharge for hydropower generation.

Empirical Study of Key Factors in Satisfaction with Subway Services (지하철 이용만족도 결정요인에 관한 실증적 연구 -서울지역을 중심으로-)

  • Shim, Jong-Seop;Jeon, Ki-Heung
    • Korean Business Review
    • /
    • v.13
    • /
    • pp.49-66
    • /
    • 2000
  • Despite the fact that understanding customers satisfaction with transportation services is a subject of great importance, authors, so far, found no systematic researches referred to that issue. From this point, studying the satisfaction with subways services can be extremely useful. Empirical study of key factors in the satisfaction with subway services is the departure point, which holds as objectives, and we believe, will contribute to overall increasing in the number of subways services used and in the amount of public benefits derived from that usage. In order to achieve these goals: First, several items referred to some key factors in the satisfaction of subway usage were systemized. Second, a research of specific weights attached to those key factors by subway passengers was conducted. Knowledge of the satisfaction variables system can provide deep insights into ones perceptual experience when using a subway. The results were as follows: Various interrelated factors compose a passengers satisfaction with subway services. People do not just use subway passively; a number of key factors, like physical and personal services, exact timing, easiness to access etc. determine the passengers satisfaction with subway. In order to find out specific weights of these key factors multiple regression analysis was employed. Results showed that satisfaction with subway is determined by (in order of importance) easiness to access, quality of physical services, friendliness of working stuff and timing exactness. According to the findings, passengers do not use subway as a simple mean of transportation, rather they perceive it as a complex combination of environmental elements and overall satisfaction depends on these various factors. Therefore, to learn passengers satisfaction with subways services, passengers subway experience must be thoroughly studied and analyzed, and this is where papers value resides.

  • PDF

Evaluating the Accuracy of Blood Pressure Measurement in General Hospital Nurses (종합병원 간호사의 혈압측정의 정확성 평가)

  • Kim Jong-Sook;Kim Sang-Soon
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.7 no.1
    • /
    • pp.7-15
    • /
    • 2000
  • To assess the accuracy of blood pressure measurement in general hospital nurses, 276 nurses at four hospital in Kyungju city and Pohang city were observed during the study period 20 December 1998 to 29 December 1998. The nurses measuring the blood pressure of simulated patient's were checked by the researcher or 20 items, that are recommended for consideration when doing a blood pressure measurement. Of the six items in the preparation step for measuring blood pressure, the accuracy of 'patients shouldn't talk during the procedure' had the lowest frequency(27.1%) and the other five items were above 80%. Of the ten items on blood pressure measuring technique, the accuracy of the frequency for 'inflating the cuff until the radial or brachial artery pulse is no longer palpable and then adding 30mmHg' was 0%, 'waiting $30{\sim}60$ seconds before reinflating the cuff' was alse 0%, 'rapidly deflating the cuff', 0.3%, 'rapidly and steadily inflating the cuff to the maximal level as per above-mentioned initial systolic pressure assessment step', 0.7%, 'reading the pressure to the nearest 2mmHg mark on the manometer', 10.8%, the remaining items were above 70%. Of the four items on blood pressure recording, the accuracy of 'recording the cuff size' had a frequency of 0.3%, 'recording the patient's position such as sitting, standing or lying position', 10.8%, 'recording the arm or leg which was used for measuring the blood pressure', 53.6%, and 'recording systolic/diastolic pressure', 100%. The variables significantly related to the accuracy of the blood pressure measurement were age, career position at hospital, and qualification education for blood pressure measurement(p<0.01). In the multiple regression analysis, position and qualification education were significant variables(p<0.01). In conclusion, the accuracy of blood pressure measurement was very low, thus, qualification education for blood pressure measurement should be done immediately to improve the accuracy of measurement by nurses in general hospitals.

  • PDF