• 제목/요약/키워드: Pulse Analysis

검색결과 2,084건 처리시간 0.035초

맥솔(脈率)과 심박변이도(心搏變移度)의 상관성(相關性) 연구(硏究) (Correlation between Pulse-respiration Ratio and Heart Rate Variability)

  • 양동훈;박영배
    • 대한한의진단학회지
    • /
    • 제10권2호
    • /
    • pp.104-120
    • /
    • 2006
  • Background : Pulse-respiration ratio has been used for estimating subject's status in oriental medicine. Pulse and respiration is strongly associated with autonomic nerve system. But there is no research about correlation between pulse-respiration ratio and autonomic nerve system. Objectives : We performed this study to know correlation between pulse-respiration ratio and HRV(heart rate variability) that shows autonomic nerve system status well and to clarify clinical meaning of pulse-respiration ratio. Methods : After subject's 10 minutes rest, we measured subject's ECG, respiration pattern and HRV. In this research, subject's number is 95(Male 50/Female 45). We calculated pulse-respiration ratio from ECG and respiration pattern. Then, we analyzed correlation between pulse-respiration ratio and HRV parameters in all subjects, 2 group divided by Wan-Maek(P-R ratio 4.28). We tried to compare HRV parameters among Wan-Maek, Sak-Maek and Ji-Maek group. Correlation analysis between pulse-respiration Ratio and Pulse rate, respiration rate is performed. Finally correlation analysis between Respiration and HRV parameters in all subjects, 2 group divided by Wan-Maek(4.28) is studied. Results : 1. Mean pulse-respiration is 4.10${\pm}$0.67, Mean pulse rate is 68.06${\pm}$7.82bpm, Mean respiration rate is 16.81${\pm}$2.72 times per minute in all subjects. 2. Correlation analysis between pulse-respiration ratio and HRV parameters of high pulse-respiration ratio group is not significant. But, in low pulse-respiration ratio group, HFnorm(correlation coefficient 0.306, p= 0.018), lnHF (0.308, p=0.002) is significantly correlated with pulse-respiration ratio. 3. Comparison of HRV parameters among Wan-Maek, Sak-Maek and Ji-Maek Group is not significant. 4. Pulse-respiration ratio is more affected by respiration rate(correlation coefficient-0.17, p=0.000) than pulse rate (correlation coefficient 0.396, p=0.000). 5. Correlation analysis between respiration rate and HRV parameters of high pulse-respiration ratio group is not significant. But, in low pulse-respiration ratio group, HFnorm (correlation coefficient -0.327, p=0.011), LF/HF(0.346, p=0.007), lnHF (-0.355, p=0.006) are significantly correlated with respiration rate. Conclusion : Pulse-respiration ratio and parasympathetic index has positive correlation. The closer Wan-Maek, The higher parasympathetic index in low pulse-respiration ratio group. Respiration rate is more related with pulse-respiration ratio than pulse rate. Respiration is negatively correlated with autonomic parameters. And the slower respiration, the higher parasympathetic index in low pulse-respiration ratio group.

  • PDF

통계분석을 통한 한의 맥진에 유용한 파라미터 도출: 부침맥을 중심으로 한 예비연구 (Proposal of pulse parameter useful for pulse wave analysis in oriental medicine: Preliminary study on floating and sinking pulses)

  • 이전;이유정;이혜정;최은지;김종열
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년 학술대회 논문집 정보 및 제어부문
    • /
    • pp.244-246
    • /
    • 2006
  • In this study, we search some parameters well-related to floating-sinking pulse by statistical analysis, because these pulses are frequently used in clinic. Pulse signals were acquired by 3D pulse analyzer and 30 subjects consist of 15 people diagnosed as floating pulse and 15 people diagnosed as sinking pulse by oriental doctors who have over 5 years clinical experience. Then, we made a representative beat template for each subject and, through a peak detection algorithm, we calculated several pulse parameters. To find the parameters related to floating-sinking pulse, we performed statistical testing with 17 parameters through the independence sampling, t-test. As a result, there is the biggest difference between pressure, the maximum pulse pressure, diastolic area(Ad) and float-sink data. (p < .05).

  • PDF

맥상기를 통한 요골동맥 맥진법의 맥파분석 - 좌관부위 맥파요인을 중심으로 - (Study on the Waveform Analysis of Radial Artery Pulse Diagnosis Using Pulse Meter and Analyzer - the Waveform Analysis of Left KWAN Pulse Dignosis -)

  • 김경철;이정원;류경호;박동일;신우진;강희정
    • 동의생리병리학회지
    • /
    • 제23권1호
    • /
    • pp.186-191
    • /
    • 2009
  • In the study on the waveform analysis of radial artery pulse diagnosis, we need to establish fundaments of contemporary pulse diagnosis research. As we will to do experimental research on the difference of pulse waveform on the radial artery with applied variations of pressure(5 stage-pressure) and measuring position(CHON, KWAN, CHEOG). First of all, in this research, we did the experiment of the study on the waveform analysis of radial artery(left KWAN) pulse dignosis by using 3 dimension pulse meter and analyzer (3D MAC). As a result. we extracted the seven measurement fluents : energy(E), size of cycle(h1), size of reflection cycle(h2), time of reflection cycle(t2), time of contraction (t4), width of cycle(w), area of waveform(A) by the statistically reasonable differences. We expect that the seven measurement fluents contribute to divide the situation through the results of waveform analysis of radial artery.

가변폭 Double-Pulse Generator에 관한 연구 (Research on the Variable-Width and Double-Pulse Generator)

  • 이병선
    • 대한전자공학회논문지
    • /
    • 제7권4호
    • /
    • pp.6-13
    • /
    • 1970
  • 여기에 기술된 가변폭 double-pulse generator는 완전 transistor화 되어서 소형이고 사용하기 간편하다 주파수는 1KHz까지 가변할 수 있으며 pulse의 폭은 0.4μsec에서 8μsec까지, pulse의 진폭은 1V에서 10V까지, double pulse 간의 간폭은 0μsec에서 12μsec까지 가별할 수 있다. 정 또는 부의 single 또는 double pulse를 얻을 수 있다. 각단마다의 해석을 하였으며 아울러 설계식을 유도하고 실험과 비교하였다.

  • PDF

독립 성분 분석과 비선형 자기상관을 이용한 동잡음이 포함된 PPG 신호에서의 맥박 검출 (Pulse Detection from PPG Signal with Motion Artifact using Independent Component Analysis and Nonlinear Auto-correlation)

  • 전학재;김정도;임승주
    • 센서학회지
    • /
    • 제25권1호
    • /
    • pp.71-78
    • /
    • 2016
  • PPG signal measured by pulse oximeter can measure pulse and the oxygen saturation of arterial blood. But the PPG signal is distorted by finger movement or other movement in the body. To detect pulse from the PPG signal with motion artifact, we use band pass filter(BPF), Independent component analysis(ICA) and nonlinear autocorrelation(NAC). BPF is used to remove DC component and high frequency noise in the PPG signal with motion artifacts. ICA is used to separate pulse signal and motion artifact. However, pulse signal separated by ICA have no choice but to accompany signal distortion because pulse signal and motion artifact are not completely independent. So, we use nonlinear autocorrelation to emphasize the pure pulse signal from the distorted signal.

모세관 맥동파 영상을 이용한 맥파 측정 시스템 (Pulse wave Measurement System by analyzing a Moving Pulse Image in the Capillary Tube)

  • 이우범;최창열;홍유식;이상석;남동현
    • 한국인터넷방송통신학회논문지
    • /
    • 제12권2호
    • /
    • pp.145-151
    • /
    • 2012
  • 심혈관계 질환의 발병 위험요인 분석이 가능한 맥진기는 한방 의료기기에서 대표적인 연구 분야 가운데 하나이다. 그러나 기존의 대부분의 센서 기반의 맥진기는 측정시의 맥박 박동처와 센서부의 접촉상태에 따른 편위, 검출된 파형의 부정확성 및 파형분석의 어려움 등에 있어서 문제점이 발생한다. 따라서 본 논문에는 특성 센서를 사용하지 않고 단지 맥동에 의해서 유발되는 모세관 시험액의 상태 변화를 촬영한 맥동영상을 분석하여 환자의 맥파의 측정이 가능한 맥진기를 제안한다. 제안한 방법에서는 맥동영상 분석을 위한 시약영역 추출, 이진화, 수정된 열림연산, 변위측정 등의 영상처리 방법들이 적용된다. 제안한 맥진기의 성능 평가를 위해서는 추출된 압맥파로부터 맥파분석에 필수적인 5가지 주요 특징점에 대한 추출률을 측정한 결과 성공적인 결과를 보였다.

손목의 피부특성을 고려한 맥상파 해석모델 개발 (Development of Pulse Wave Analysis Model with Skin Effect)

  • 신상훈
    • 대한한의진단학회지
    • /
    • 제15권2호
    • /
    • pp.159-168
    • /
    • 2011
  • Objectives: The purpose of this study is to develop the pulse wave analysis model with the palpation pressure and the skin effect. Methods: The position of pulse diagnosis was modeled with elastic string system. The skin was modeled with the elastic string, the palpation pressure with tension in the string, and the blood vessel pressure with external force on the string. Using the wave equation in the physics, the simplified pulse model was transformed to the mathematical model. Results: To the verification of the model, the effects of the palpation pressure and the skin effect were tested. Conclusions: There was optimal palpation pressure, describing the exact vessel pressure pattern and maximizing the amplitude of the skin displacement. For the optimal condition, the increased palpation pressure was needed with the increased skin thickness. Therefore, the developed pulse wave analysis model showed the good results.

펄스코로나 방전의 전극길이, 펄스반복율에 따른 부하 임피던스 변화 특성 및 EMTP 해석 (The EMTP Analysis and Characteristics of Load Impedance on Various Electrode length, Pulse Repetition in Pulse Corona Discharging)

  • 정종한;송우정;전진안;정현주;홍정환;김희제
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제51권4호
    • /
    • pp.158-163
    • /
    • 2002
  • The pulsed Power system has been widely used to many applications, such as E/P(Electrostatic Precipitator), DeNOx/DeSOx power system, often generator, etc. In this paper, we study EMTP analysis and characteristics of critical voltage and load in impedance on various electrode length of pulse corona. To obtain a stable pulse voltage, we designed a compact pulse generator switched MOSFET and tested their characteristics by adjusting electrode length and pulse repetition. As a re sult, critical voltage of pulse corona and load impedance on increasing electrode length were decreased. These results indicate we can control critical voltage of pulse corona and suppress arc discharging between two electrodes.

승객 상해를 최소화하는 충돌특성곡선의 결정 및 반응표면법을 이용한 충돌 부품의 최적설계 (Determination of Crash Pulse to Minimize Injuries of Occupants and Optimization of Crash Components Using Response Surface Method)

  • 홍을표;신문균;박경진
    • 한국자동차공학회논문집
    • /
    • 제9권2호
    • /
    • pp.116-129
    • /
    • 2001
  • Traditional occupant analysis has been performed with a pre-determined crash puse which is produced from a test and the involved components are designed based on the analysis resuls. The method has limitations in that the design does not have much freedom. Howrver, if a good crash pulse is proposed, the body structure can be modified to generate the crash pulse. Therefore, it is assumed that the crash pulse can be changed to imptove the occupant crash performance. A preferable crash pulse is determined to minimize the occupant injuty. A constraint is established to keep the phenomena of physics valid. The response surface method(RSM) is adopted for the optimization process. An RSM in a commercial code is utilzed by interfacing with an in-house occupant analysis program called SAFE(Safety Analysis For occupant crash Enviroment). Design of involved components called is carried out through optimization with the RSM. The advantages of the RSM are investigated as opposed to other methods, and the tesults are compared. Also, the design under the new crach pulse is compared with that trom the pre-detetmined pulse.

  • PDF

여성 불임환자의 맥진특성 연구 (A Study on Characteristics of Pulse Diagnosis in Infertile Women)

  • 유정은;장새별;유동열
    • 혜화의학회지
    • /
    • 제23권2호
    • /
    • pp.15-21
    • /
    • 2015
  • Objective : The purpose of this study is to demonstrate the characteristics of pulse diagnosis in infertile women. Methods : We have studied 38 women infertility patients in the Dunsan oriental hospital by using pulse diagnostic device. Pulsation and pulse types have been analyzed with variables of infertility factors. Statistical analysis was performed by adopting descriptive and inferential tests. Results : Both right and left chi parts were shown different from other parts. In small intestine and gall bladder showed significantly different pulsation according to the infertility factor. Short pulse, fine pulse, skipping pulse, shallow pulse and deep pulse were often representative pulse types for the main organs of woman infertility. In Triple energizers showed significantly different shallow pulse type according to the infertility factor. Conclusion : The results corresponded closely with previous literature on pulse diagnosis about infertile women.

  • PDF