• Title/Summary/Keyword: Pulse Accumulation

Search Result 53, Processing Time 0.027 seconds

Voltammetric Behavior and Determination of Rubeanic acid at Mercury (수은 전극에서 루비안산의 전압-전류 거동 및 정량)

  • Kwon, Young-Soon;Koo, Hee-Jin
    • Analytical Science and Technology
    • /
    • v.10 no.3
    • /
    • pp.216-224
    • /
    • 1997
  • In the study of cyclic voltammogram of rubeanic acid, rubeanic acid has two reduction peaks; first peak is similar with that of $S^{2-}$ and thiourea, which is conceded to by HgS, second peak is very weak and unidentified. The study also describes the differential pulse cathodic stripping voltammetric method for the determination of rubeanic acid. The followings were optimal conditions of rubeanic acid for the study : 0.05M borate buffer solution(pH 10.0) ; an accumulation potential of -0.30V(vs. Ag/AgCl); accumulation time of 120sec. : scan rate of 10mV/sec. The detection limit of trace analysis shows $2.7{\times}10^{-8}M$ of rubeanic and at optimal conditions.

  • PDF

Adaptive Control of Machined Surface Using Current of the Feed Motor at Rest (정지상태 모터의 전류 신호를 이용한 피삭재의 가공면 적응제어)

  • 정영훈;윤승현;조동우
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.10a
    • /
    • pp.79-82
    • /
    • 1997
  • The current from the feed motor of a machine tool contains substantial information about the machining state. There have been many researches that investigated the current as a measure for the cutting forces. However it has not been reported that indirect measurement of the cutting forces from the current of the feed motor at rest is possible. The cutting force normal to the machined surface influences the machined surface of the workpiece, which makes it necessary to estimate this force to control the roughness of the machined surface. But the unpredictable behavior of the current prevents applying the current to prediction of the cutting state. In this paper, empirical approach was conducted to resolve the problem. Also parametric adaptive and fuzzy logic control strategies are applied to the force regulation problem. As a result, the current is shown to be related to the accumulation of the infinitesimal rotation of the motor, and besides the unpredictable behavior of the current is shown to be caused by the relationship. Subsequently the relationship between the current and the cutting force is identified, and it is presented that control of machined surface using the current of the feed motor at rest is possible.

  • PDF

Analysis of the Characteristics of the Feed motor Current for the Estimation of the Cutting Force in General Cutting Environment (일반적 상황에서 2차원 절삭력 추정을 위한 이송모터 전류의 거동분석)

  • Jeong, Young-Hun;Yun, Seong-Hyun;Cho, Dong-Woo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.19 no.4
    • /
    • pp.93-100
    • /
    • 2002
  • The current from the feed motor of a machine tool contains substantial information about the machining state. There have been many researches that investigated the current as a measure for the cutting farces. However it has been reported that this indirect measurement of the cutting farces from the feed motor current is only feasible in low frequency. In this research, it was presented that the bandwidth of the current monitoring can be expanded to 130 Hz. And the unusual behavior of the current was examined in this bandwidth. The cross-feed directional cutting force influences the machined surface of the workpiece, which makes it necessary to estimate this force to control the roughness of the machined sulfate. The current exists in the stationary feed motor, and it can give the useful information on the quality of the machined surface. But the unpredictable behavior of the current prevents applying the current to prediction of the cutting state. Empirical approach was conducted to resolve the problem. As a result, the current was shown to be related to the accumulation of the accumulation of the infinitesimal rotation of the motor. rotation of the motor. Subsequently the relationship between the current and the cutting force was identified.

Improved Production of Medium-Chain-Length Polyhydroxyalkanoates in Glucose-Based Fed-Batch Cultivations of Metabolically Engineered Pseudomonas putida Strains

  • Poblete-Castro, Ignacio;Rodriguez, Andre Luis;Lam, Carolyn Ming Chi;Kessler, Wolfgang
    • Journal of Microbiology and Biotechnology
    • /
    • v.24 no.1
    • /
    • pp.59-69
    • /
    • 2014
  • One of the major challenges in metabolic engineering for enhanced synthesis of value-added chemicals is to design and develop new strains that can be translated into well-controlled fermentation processes using bioreactors. The aim of this study was to assess the influence of various fed-batch strategies in the performance of metabolically engineered Pseudomonas putida strains, ${\Delta}gcd$ and ${\Delta}gcd-pgl$, for improving production of medium-chain-length polyhydroxyalkanoates (mcl-PHAs) using glucose as the only carbon source. First we developed a fed-batch process that comprised an initial phase of biomass accumulation based on an exponential feeding carbon-limited strategy. For the mcl-PHA accumulation stage, three induction techniques were tested under nitrogen limitation. The substrate-pulse feeding was more efficient than the constant-feeding approach to promote the accumulation of the desirable product. Nonetheless, the most efficient approach for maximum PHA synthesis was the application of a dissolved-oxygen-stat feeding strategy (DO-stat), where P. putida ${\Delta}gcd$ mutant strain showed a final PHA content and specific PHA productivity of 67% and $0.83g{\cdot}l^{-1}{\cdot}h^{-1}$, respectively. To our knowledge, this mcl-PHA titer is the highest value that has been ever reported using glucose as the sole carbon and energy source. Our results also highlighted the effect of different fed-batch strategies upon the extent of realization of the intended metabolic modification of the mutant strains.

A Digital Signal Processing Circuit Design for Position Sensitive Detectors(PSD), using an FPGA

  • Bongsu Hahn;Park, Changhwan;Park, Kyihwan
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.107.1-107
    • /
    • 2001
  • In this paper, a digital signal processing circuit for Position Sensitive Detectors(PSDs) is introduced to substitute the conventional analog signal processing circuit and to compensate disadvantages of the PSD. In general, the analog circuits have the problems such as noise accumulation, sensitivity for environmental changes, and high cost for manufacturing. Moreover, the intrinsic nonlinearity problem of the PSD makes it hard to measure the position accurately because it is difficult to be overcome the problem by using the conventional analog circuits, which can be solved by using the digital signal processing circuit. The circuit is implemented by using a Field Programmable Gate Array (FPGA). The Pulse Amplitude Modulation(PAM) method is used for reducing the environmental noise effect, and a linear interpolation logic is used to compensate the ...

  • PDF

Precision microdrilling of alumina ceramic substrates by femtosecond laser ablation (펨토초 레이저 어블레이션을 이용한 알루미나 세라믹 기판의 정밀 마이크로 드릴링)

  • Kim, S.H.;Sohn, I.B.;Noh, Y.C.;Lee, J.M.;Jeong, S.H.
    • Laser Solutions
    • /
    • v.11 no.1
    • /
    • pp.25-31
    • /
    • 2008
  • The characteristics of femtosecond laser ablation of $Al_2O_3$ for prescision microfabrication are studied experimentally. Specifically, the process time during femtosecond laser drilling of microholes with $sub-100{\mu}m$ diameter are investigated for varying laser fluence, scan speed and beam path designs like trepanning with continuously changed start points. The accumulation of sub-micrometer size particles within the hole and the deterioration of edge clarity and roundness for decreasing hole diameter are examined and through process optimization the microdrilling with good hole quality is achieved using a femtosecond laser system (repetitionrate 1 kHz, wavelength 785 nm, pulse duration 185 fs)

  • PDF

WATER INDUCED MECHANICAL EFFECT ON THE DENTAL HARD TISSUE BY THE SHORT PULSED LASER

  • Kwon,Yong-Hoon;Kim, You-Young
    • Journal of Photoscience
    • /
    • v.5 no.1
    • /
    • pp.33-37
    • /
    • 1998
  • One macroscopic effect in the free-running Er:YAG laser is an accumulation of microscopic effects. Understanding of the exogenous water induced mechanical effect on the dental hard tissue by the Qswitched Er:YAG laser has an important impact on the further understanding of the free-running Er:YAG laser ablation on the dental hard tissue. The Q-switched Er:YAG laser (1-$\mu$s-long pulse width) was used in the recoil pressure measurement with an aid of water-jet system and a pressure transducer. The amplitude of the recoil pressure depends on the tooth surface conditions (dry and wet) and the volume of the water upon it. Wet surfaces yielded higher recoil pressure than that of dry, surface, and as the volume of the exogenous water drop increased, the amplitude of the recoil pressure increased also.

  • PDF

Determination of Memory Trap Distribution in Charge Trap Type SONOSFET NVSM Cells Using Single Junction Charge Pumping Method (Single Junction Charge Pumping 방법을 이용한 전하 트랩 형 SONOSFET NVSM 셀의 기억 트랩 분포 결정)

  • 양전우;흥순혁;박희정;김선주;서광열
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.453-456
    • /
    • 1999
  • The Si-SiO$_2$interface trap and nitride bulk trap distribution of SONOSFET(polysilicon-oxide-nitride-oxide-semiconductor)NVSM(nonvolatile semiconductor memory) cell were investigated by single charge pumping method. The used device was fabricated by 0.35 7m standard logic fabrication including the ONO cell process. This ONO dielectric thickness is tunnel oxide 24 $\AA$, nitride 74 $\AA$, blocking oxide 25 $\AA$, respectively. Keeping the pulse base level in accumulation and pulsing the surface into inversion with increasing amplitudes, the charge pumping current flow from the single junction. Using the obtained I$_{cp}$-V$_{h}$ curve, the local V$_{t}$ distribution, doping concentration, lateral interface trap distribution and lateral memory trap distribution were extracted. The maximum N$_{it}$($\chi$) of 1.62$\times$10$^{19}$ /cm$^2$were determined.mined.d.

  • PDF

A study on the method of Macjin(脈診) in The Whang Di Nei Qing(黃帝內徑) (황제내경(黃帝內徑)에 나타난 맥진법(脈診法)에 관한 연구(硏究))

  • Jang, Yong Woo;Lim, Jin Seok
    • Journal of Korean Medical classics
    • /
    • v.11 no.2
    • /
    • pp.146-168
    • /
    • 1998
  • This thesis is a study on the diagnostic theory and methods of Macjin(checking of pulse) as described in the Whang Di Nei Qing. There are four methods of Macjin in this text, namely: Dong Macjin(動脈法), Sam Bu Gu Who Macjin(三部九脈診). In Young Gi Gu Macjin(人迎氣口脈診法), Nei Qing's Gi Gu Macjin(內徑의 氣口脈法). Each method developed in it's own way, but they are all closely related and became the basis of today's Macjin. I examined the methods of Macjin in the Whang Di Nei Qing from a perspective of "change". The main questions of this study are: "What brought about the development of the different methods?". "How do the methods differ?", and "how did these methods evoke into today's Macjin?". The method of Macjin generated spontaneously from the observation and treatment of disease. Dong Macjin was the first method developed and became the basis of subsequent forms of Macjin. The accumulation of medical knowledge and the influence of oriental philosophy fueled the evolution of Macjin. Chronologically, Macjin methods developed starting with Dong Macjin and eventually into Sam Bu Gu Who Macjin. In Young Gi Gu Macjin, and Nei Qing's Gi Gu Macjin. The different methods of Macjin vary in how many pulse points are checked, and were established with simplicity and effectiveness in mind. Dong Macjin involves the checking the whole body. Sam Bu Gu Who Macjin involves nine points. In Young Gi Gu Macjin involves four points. and Nei Qing's Gi Gu Macjin involves two. In it's early development, the checking of a patient's pulse was used to diagnose only localized disorders in comparison with symptoms. It evolved with Oh Jang Mad(五臟脈, five main types of pulse) to be able to check internal organs with the introduction of Nei Qing's Gi Gu Macjin. After the division of Chon Kwan Chuck(寸關尺), it evolved further to be able to make a detailed diagnosis by using the result of pules checks. Nowadays, we can make 28 forms of diagnostic indices from these development. In conclusion, Macjin can be used practically and effectively in the diagnosis of disease. In using three methods of Macjin(In Young Gi Gu Macjin, Nei Qing's Gi Gu Macjin, and today's Gi Gu Macjin, which can determine the whole body's Siate of well-being) in conjunction with Dong Macjin(which helps pinpoint the localized disorder), an exact diagnosis can be obtained. I strongly feel that we should acquire objectivity by accommodating Macjin with modern methods of medicine.

  • PDF

A Tank Model Application to Soyanggang Dam and Chungju Dam with Snow Accumulation and Snow Melt (적설 및 융설 모의를 포함한 탱크모형의 소양강댐 및 충주댐에 대한 적용)

  • Lee, Sang-Ho;An, Tae-Jin;Yun, Byung-Man;Shim, Myung-Pil
    • Journal of Korea Water Resources Association
    • /
    • v.36 no.5
    • /
    • pp.851-861
    • /
    • 2003
  • Snow accumulation and snow melt was simulated and included in the computation of the watershed runoff for Soyanggang Dam and Chungju Dam. A modified Tank Model was used for the simulation, which has three serial tanks and a pulse response function. The model parameters were estimated through the global optimization method of Shuffled Complex Evolution-University of Arizona (SCE-UA). A watershed was divided into four zones of elevation. The temperature decrease of the zones was a rate of -0.6$^{\circ}C$/100m. Almost all precipitation from December to February become accumulated as snow, and then the snow melts and runs off from March to April. The average runoff with snow melt was greater than the average runoff without snow melt during the period from March to April. The improved amount from snow melt simulation was about one fifth of the observed one for Soyanggang Dam. The increased amount for Chungju Dam was about one fourth of the observed average runoff during the same period. Although the watershed runoff was simulated including snow melt, it was less than the observed one for both of the dams.