• Title/Summary/Keyword: Pulsation Ratio

Search Result 53, Processing Time 0.027 seconds

A Study on MR Cholangiography using Breathing Hold Target Techniqu by Prospective Acquisition Correction and Respiration Trigger Gating (Non Breathe Hold Technique를 이용한 MR 담도계조영술에 대한 고찰 : Prospective Acquisition Correction(PACE)기법과 Respiration Trigger Gating(RTG) 기법의 비교)

  • Goo, Eun-Hee;Jeong, Hong-Ryang;Im, Cheong-Hwan;Kweon, Dae-Cheol;Jo, Jeong-Keun;Lee, Man-Koo
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.10 no.1
    • /
    • pp.45-50
    • /
    • 2008
  • Recently, MR Cholangiography used mainly bu controlling of patient's breathing. There is breathing hold techniques to get images within shopt time and gating technique adjusted to respiration cycle for high resolution image. In this study, the aim of this experiment is to know on clinical usefulness compared with PACE and RTG thchniques. This study's period is from 2006 in November to 2007 in January. A total of 21 patients investigated at MAGNETOM Sonata 1.5T (SIEMENS Erlangen) with use of 12ch body coil. MR acquisition protocol used 3D turbo spin echo coronal sequence. Scan parameters applied to potimal setting in use as gating techniques, respectively. Analysis of consuming timing evaluated with rapidness. As analysis of quantity, the common bile duct, gall bladder measured in signal intensities, then these data were calculated by signal to noise ratio and contrast to noise ratio. Qualitative analysis, experienced 2radiologists and 3 RTs were evaluated into 3groups about artifact, accuracy of lesions, sharpness of the common bile duct or gall bladder. As a result of analysis, when compared to PACE, consuming time of the RTG took less than PACE, On both CNRs and SNRs, PACE technique was slightly high values than RTG(p<0.05). Qualitative analysis' results, discrimination of lesions in the common bile duct, gall bladder get a significance level in both RTG and PACE techniques but presence's artifact of breathing and pulsation highly demonstrate in PACE techniques. In conclusion, both PACE and RTG methods at MRCP provided prominently clinical information for the common bile duct, gall bladder. If machines have not limitation with performance, induction of breathing holding also will help getting diagnistic quality.

  • PDF

Flow-Turbine Interaction CFD Analysis for Performance Evaluation of Vertical Axis Tidal Current Turbines (I) (수직축 조류 터빈 발전효율 평가를 위한 유동-터빈 연동 CFD 해석 (I))

  • Yi, Jin-Hak;Oh, Sang-Ho;Park, Jin-Soon;Lee, Kwang-Soo;Lee, Sang-Yeol
    • Journal of Ocean Engineering and Technology
    • /
    • v.27 no.3
    • /
    • pp.67-72
    • /
    • 2013
  • In this study, numerical analyses that considered the dynamic interaction effects between the flow and a turbine were carried out to investigate the power output performance of an H-type Darrieus turbine rotor, which is one of the representative lifting-type vertical-axis tidal-current turbines. For this purpose, a commercial CFD code, Star-CCM+, was utilized for an example three-bladed turbine with a rotor diameter of 3.5 m, a solidity of 0.13, and the blade shape of an NACA0020 airfoil, and the optimal tip speed ratio (TSR) and corresponding maximum power coefficient were evaluated through exhaustive simulations with different sets of flow speed and external torque conditions. The optimal TSR and maximum power coefficient were found to be approximately 1.84 and 48%, respectively. The torque and angular velocity pulsations were also investigated, and it was found that the pulsation ratios for the torque and angular velocity were gradually increased and decreased with an increase in TSR, respectively.

Comparison research of HRV between Postpartum Women and Normal Women (산후 여성의 심박변이도 특성 연구)

  • Kang, Mun-Su;Park, Hyun-Chul;Kim, Lak-Hyung
    • Journal of Oriental Neuropsychiatry
    • /
    • v.17 no.2
    • /
    • pp.179-185
    • /
    • 2006
  • Objective : This research was designed to study the characteristics of heart rate variability in postpartum women compared with normal women. Method : HRV data of postpartum women were gathered from 255 women who was hospitalized for oriental postpartum treatments(Age : 25-35). HRV data of comparison group were gathered from 327 women who visited hospital to check up their health(Age : 25-35). The SPSS 12.0 for windows was used to analyze the date and the independent samples t-test was used to verify the result. Result : 1. Mean-RR and SDNN of postpartum women group significantly decreased compared with that of normal women group. But, Heart Rate of postpartum women group significantly increased compared with that of normal women group. 2. HRV-Index, RMSSD and SDSD of postpartum women group significantly decreased compared with that of normal women group. pNN50 of postpartum women group significantly increased compared with that of normal women group. 3. Ln(TP), Ln(VLF), Ln(LF) and Ln(HF) of postpartum women group significantly increased compared with that of normal women group. 4. There were no significant differences in Normal LF, Normal HF and LF/DF Ratio between postpartum women group and normal women group. Conclusion : The result suggest that the function of heart of postpartum women group significantly decreased compared with that of normal women group. Futhermore although the ANS maintained the balance in the range of normality, the sympathetic nervous system frequently revitalized which caused increasing the heart of pulsation.

  • PDF

Clinical Usefulness of Phase-Contrast Cine MRI Evaluation in Patients with Cervical Myelopathy (경추 척수병증 환자에 있어서 Phase-Contrast Cine MRI 평가의 임상적 유용성)

  • Lim, Jeong-Hwan;Song, Jun-Hyeok;Shin, Kyu-Man;Kim, Sung-Hak
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.12
    • /
    • pp.1634-1641
    • /
    • 2000
  • Objective : The cerebrospinal fluid(CSF) pulsates within the craniospinal axis in response to rhythmic cerebral blood volume variation during the cardiac cycle. The aim of this study is to characterize the normal and abnormal CSF flow and its waveforms in the cervical spinal subarachnoid space. Methods : The magnetic resonance(MR) images were obtained with 1.5 T(GE Signa, GE Medical Systems, Milwaukee, USA) unit using the 2 dimensional cine PC(phase contrast) sequence with cardiac gating and gradient recalled echo imaging. This pulse sequence yielded 16 quantitative flow-encoded images per cardiac cycle. Sagittal and axial images of the cervical spinal CSF space were obtained, and target sites were analyzed for characteristic CSF flow (TR=50ms, TE=12.5-15ms). The region of interest(ROI) was 1mm 3 in volume. Twenty six persons were included in this study : 10 healthy volunteers and 16 patients with cervical myelopathy. The post-operative cine MR study were also done in five patients. Results : The normal CSF pulsation dynamics in the cervical spine showed discrete systolic and diastolic components. The CSF flow revealed a sine wave pattern, in which the systolic phase was shorter than the diastolic phase(ratio=2 : 3). The patient group revealed decreased amplitudes of the CSF flow and irregularly distored flow waves. The systolic phase was elongated in the ROI above the stenotic level, whereas the diastolic phase was lengthened below the level. In the postoperative images, the abnormal pattern and amplitude were found to be corrected. Conclusion : From these results, the authors believe that the CSF flow study provides valuable informations regarding the extent of cervical stenosis and may be useful for the surgical planning and post-operative evaluation.

  • PDF

Non-invasive hematocrit measurement (혈액중 non-invasive hematocrit 분석)

  • Yoon, Gil-Won;Jeon, Kye-Jin;Park, Kun-Kook;Lee, Jong-Youn;Hwang, Hyun-Tae;Yeo, Hyung-Seok;Kim, Hong-Sig
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2002.11a
    • /
    • pp.59-62
    • /
    • 2002
  • Wavelength selection and prediction algorithm for determining hematocrit are investigated. A model based on the difference in optical density induced by the pulsation of heart beat is developed by taking approximation of Twersky's theory on the assumption that the variation of blood vessel size is small during arterial pulsing[1]. A device is constructed with a five-wavelength LED array as light source. The selected wavelengths are two isobestic points and three in compensation for tissue scattering. Data are collected from 549 out-patients who are randomly grouped as calibration and prediction sets. The range of percent hematocrit was 19.3∼51.8. The ratio of the variations of optical density between systole and diastole at two different wavelengths is used as a variable. We selected several such variables that show high reproducibility among all variables. Multiple linear regression analysis is made. The relative percent error is 8% and the standard deviation is 3.67 for the calibration set. The relative % error and standard deviation of the prediction set are 8.2% and 3.69 respectively. We successfully demonstrate the possibility of non-invasive hematocrit measurement, particularly, using the wavelengths below 1000nm.

  • PDF

Validity Test of Korean Pain Measurement Tool Using Normal Adult Individuals (정상성인에서의 한국어휘를 이용한 통증척도의 타당도 조사)

  • 이은옥;이숙희
    • Journal of Korean Academy of Nursing
    • /
    • v.16 no.2
    • /
    • pp.13-28
    • /
    • 1986
  • The main purpose of th study was to evaluate he validity of Korean Pain Measurement Tool composed of pain terms. The specific purposes of this study were 1. to examine whether pain intensities of pain terms are congruent with those classified in three previous studies. 2. to evaluate the relative intensity of each term by panel of judges. 3. to explore the difference of ranks of pain terms according to the sex, education, and ages. One hundred and sixty normal individuals were selected by 2$\times$2$\times$4 sampling design. Sex (male, female), education (high school, college), and age (20s, 30s, 40s, 50s) were matched. Each individual was asked to rate the ranks of 3~8 pain terms in each subclass. The data measured by ordinal scale were transformed to the interval scale to compare with the pain intensities gained from the previous study. The pain ranks different from previous results were finally rearranged or cancelled through the consultation of 4 panel of judges and sunmed up to 91 pain terms in the scale. As a result, the ranks of pain terms within each of eleven subclasses among the twenty subclasses completely were congruent with the Previous pain ranks, while the ranks of nine subclasses were different from the previous pain ranks. In addition, there was significant relation between sex and pain ranks in skin punctuate pressure pain and cavity pressure. (sp : $\chi$$^2$=5.18 ø=0.26; cp : $\chi$$^2$=5.83 ø=0.24) In conclusion, seven terms from subclasses of inflammatory repeated pain, traction pressure pain, fatigue-related pain, fear-related pain, dull pain, and pulsation. related pain were cancelled. The ranks of four terms in subclasses of incisive Pressure pain and constrictive pressure pain were tentatively rearranged. Ranks of two terms in the tract pain were left as shown in the third study. As a result, six terms must be studied repeatedly for obtaining exact scores from ratio scale.

  • PDF

KIC 6206751: the first R CMa-type eclipsing binary with ɣ Doradus pulsations

  • Lee, Jae Woo;Park, Jang-Ho
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.44 no.1
    • /
    • pp.84.2-84.2
    • /
    • 2019
  • We present the absolute properties of the double-lined eclipsing binary KIC 6206751 exhibiting multiperiodic pulsations. The Kepler light curve of this system was simultaneously solved with the previously published radial-velocity data. The results indicate that the binary star is a short-period semi-detached system with fundamental parameters of $M_1=1.66{\pm}0.04M_{\odot}$, $M_2=0.215{\pm}0.006M_{\odot}$, $R_1=1.53{\pm}0.02R_{\odot}$, $R_2=1.33{\pm}0.02R_{\odot}$, $L_1=5.0{\pm}0.6L_{\odot}$, and $L_2=0.96{\pm}0.09L_{\odot}$. We applied multiple frequency analyses to the eclipse-subtracted light residuals and detected the 42 frequencies below $2.5days^{-1}$. Among these, three independent frequencies of $f_2$, $f_3$, and $f_4$ can be identified as high-order ($38{\leq}n{\leq}40$) low-degree (l=2) gravity-mode oscillations, whereas the other frequencies may be orbital harmonics and combination terms. The ratios between the orbital frequency and the pulsation frequencies are $f_{orb}:f_{2-4}{\simeq}2:3$, which implies that the ${\gamma}$ Dor pulsations of the detached primary star may be excited by the tidal interaction of the secondary companion. The short orbital period, and the low mass ratio and $M_2$ demonstrate that KIC 6206751 is an R CMa-type star, which is most likely evolving into an EL CVn star. Of seven well-studied R CMa-type stars, our program target is the only eclipsing binary with a ${\gamma}$ Dor pulsating component.

  • PDF

Long-term simultaneous monitoring observations of SiO and H2O masers toward Mira variable WX Serpentis

  • Lim, Jang Ho;Kim, Jaeheon;Son, Seong Min;Suh, Kyung-Won;Cho, Se-Hyung;Yang, Haneul;Yoon, Dong-Hwan
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.46 no.2
    • /
    • pp.49.1-49.1
    • /
    • 2021
  • We carried out simultaneous monitoring observations of five maser lines, H2O (22 GHz), SiO 𝝊 =1, 2, J =1-0 (43.1, 42.8 GHz), and SiO 𝝊 =1, J=2-1, J =3-2 (86.2, 129.3 GHz), toward the Mira variable star WX Serpentis with the 21-m antennas of the Korean VLBI Network (KVN) in 2009-2021 (~12 years). Most spectra of the H2O maser are well separated into two parts of two blue- and one redshifted features within ± 10 km s-1 of the stellar velocity. All detected SiO masers are generally concentrated within ± 5 km s-1 of the stellar velocity, and sometimes appear split into two components. Overall, the profiles of SiO and H2O masers detected in WX Serpentis illustrate typical characteristics of the Mira variable. In addition, flux variations of both SiO and H2O masers are well correlated with the optical light curve of the central star, showing a phase lag of ~ 0.1 for SiO masers and ~ 0.2 for H2O maser. This phenomenon is considered to be the direct effect of propagating shock waves generated by the stellar pulsation, because SiO and H2O masers are sequentially distributed at different positions with respect to the central star. In addition, we analyzed long-term trends and characteristics of maser velocities, maser ratio, and the velocity extents (the full width at zero power; FWZP). We also investigated a spectral energy distribution (SED) ranging from 1.2 to 240 ㎛ obtained using several infrared data: 2MASS, WISE, IRAS, ISO, COBE DIBRE, RAFGL, and AKARI (IRC and FIS). From the IRAS LRS and ISO SWS spectra of this star, we identified 9.7 and 12 ㎛ silicate emission features consistent with the SE6 spectrum model, corresponding to the typical AGB phase.

  • PDF

Absolute Dimensions And Period Changes Of The Semi-Detached Algol Type Binary XZ Canis Minoris

  • Kim, Hye-Young;Kim, Chun-Hwey;Hong, Kyeongsoo;Jeong, Min-Ji;Park, Jang-Ho;Song, Mi-Hwa;Lee, Jae Woo;Lee, Chung-Uk
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.44 no.2
    • /
    • pp.64.1-64.1
    • /
    • 2019
  • The first high-resolution spectroscopic and new multiband photometric observations of the semi-detached Algol type binary XZ CMi were performed at the Bohyunsan Optical Astronomy Observatory (BOAO) and the Sobaeksan Optical Astronomy Observatory (SOAO), respectively. A total of 34 spectra were obtained using the 1.8 m reflector of the BOAO equipped with the Bohyunsan Optical Echelle Spectrograph to construct the radial velocity (RV) curves of the eclipsing pair. New BVRI photometric light curves were also covered by using the SOAO 61cm reflector and a CCD camera. A detailed analysis of all eclipse timings shows that the orbital period of XZ CMi has varied in an upward parabolic variation superposed on a sinusoidal oscillation with a period of 38.0 yr and a semi-amplitude of 0.0071 days. From the spectral analysis, the effective temperature and the projected rotational velocity of the primary component were determined to be Teff,1 = 7387±161 K and v1sini = 122±6 km s-1, respectively. Our simultaneous synthesis of the double-lined RV and BVRI light curves gives the reliable system parameters of XZ CMi with a mass ratio (q) of 0.314, an orbital inclination (i) of 81.9 deg and a large temperature difference (∆T) of 2481 K. The individual masses and radii of both components are M1 = 1.91±0.08M, M2 = 0.60±0.02M, R1 = 1.60±0.02R, R2 = 1.13±0.02R, respectively. Although the primary component is located inside the δ Sct and γ Dor instability strips, no evidence of pulsation in the system was detected. The possible evolutionary status of XZ CMi is discussed.

  • PDF

Structure and Evolution of a Numerically Simulated Thunderstorm Outflow (수치 모사된 뇌우 유출의 구조와 진화)

  • Kim, Yeon-Hee;Baik, Jong-Jin
    • Journal of the Korean earth science society
    • /
    • v.28 no.7
    • /
    • pp.857-870
    • /
    • 2007
  • The structure and evolution of a thunderstorm outflow in two dimensions with no environmental wind are investigated using a cloud-resolving model with explicit liquid-ice phase microphysical processes (ARPS: Advanced Regional Prediction System). The turbulence structure of the outflow is explicitly resolved with a high-resolution grid size of 50m. The simulated single-cell storm and its associated Kelvin-Helmholtz (KH) billows are found to have the lift stages of development maturity, and decay. The secondary pulsation and splitting of convective cells resulted from interactions between cloud dynamics and microphysics are observed. The cooled downdrafts caused by the evaporation of rain and hail in the relatively dry lower atmosphere result in thunderstorm cold-air outflow. The outflow head propagates with almost constant speed. The KH billows formed by the KH instability cause turbulence mixing from the top of the outflow and control the structure of the outflow. Ihe KH billows are initiated at the outflow head, and pow and decay as moving rearward relative to the gust front. The numerical simulation results of the ratio of the horizontal wavelength of the fastest growing perturbation to the critical shear-layer depth and the ratio of the horizontal wavelength of the billow to its maximum amplitude are matched well with the results of other studies.