• 제목/요약/키워드: Pulsatile flow

검색결과 159건 처리시간 0.029초

원형관에서의 음해법을 이용한 차원 3차원 비압축성 부정류 흐름에 관한 수치모의 (Three Dimensional Incompressible Unsteady Flows in a Circular Tube Using the Navier-Stokes Equations With Beam and Warming Method)

  • 박기두;이길성;성진영
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2008년도 학술발표회 논문집
    • /
    • pp.1624-1629
    • /
    • 2008
  • The governing equations in generalized curvilinear coordinates for a 3D pulsatile flow are the Incompressible Navier-Stokes (INS) equations with the artificial dissipative terms and continuity equation discretized using a second-order accurate, finite volume method on the nonstaggered computational grid. This method adopts a dual or pseudo time-stepping Artificial Compressibility (AC) method integrated in pseudo-time. The computational technique implements the implicit approximate factorization method of the Beam and Warming method (1978), which is the extension of the Alternate Direction Implicit (ADI) method. The algorithm yields practically identical velocity profiles and secondary flows that are in excellent overall agreement with an experimental measurement (Rindt & Steenhoven, 1991).

  • PDF

Hemodynamically Isolated Intracranial Aneurysms on DSA and CEMRA: Clinical and Experimental Data

  • 정태섭;강원석;심용운;임윤철;이승구;주진양
    • 대한자기공명의과학회:학술대회논문집
    • /
    • 대한자기공명의과학회 2001년도 제6차 학술대회 초록집
    • /
    • pp.134-134
    • /
    • 2001
  • Purpose: To evaluate the physiologic background of poorly visualized aneurysms during DSA a contrast-enhanced MRA(CEMRA) due to hemodynamical isolation on clinical and experiment data. Method: Two cases of intracranial aneurysm which were poorly visualized on DSA a CEMRA and one case of intracranial aneurysm which had poor turnover of contrast mediu during DSA were selected for this clinical study. We evaluated the turnover of blood in t terminal aneurysm of handmade elastic silicon phantoms for comparative experiment. Flo experiments with DSA and contrast enhanced MRA were performed in elastic phantoms aneurysm with 3 different diameters (2, 5 and 10 mm) of neck mimicking basilar ti aneurysm, attached to pulsatile pump similar to that of human physiologic parameters. W compared the results with those of computational flow dynamics(CFD).

  • PDF

두개 외 경동맥류의 외과적 치료;1례 치험 (Surgical Treatment of Extracranial Carotid Aneurysm - One case report -)

  • 이만복
    • Journal of Chest Surgery
    • /
    • 제24권1호
    • /
    • pp.106-112
    • /
    • 1991
  • A 37-year old man was admitted due to the left subauricular mass of 6 month duration which was 3 x 4cm sized, pulsatile and slowly growing He was suffered from the intermittent left facial and auricular pain radiating to the occipital area. The carotid angiography revealed 3x4cm sized saccular aneurysm of the left internal carotid artery just above the carotid bifurcation, extending to the mandibular angle level. He was planned to be operated under the direct clamp of internal carotid artery or shunting procedure. But, the back pressure of the internal carotid was 35mmHg, which suggested adequate cerebral collateral. Thereby, aneurysmectomy and restoration of cerebral blood flow with saphenous vein graft was done under the direct clamp of internal carotid artery for 25 minutes. Although mild transient neurologic sequelae such as mydriasis, tongue deviation for 10 days, he recovered completely without any complication. The aneurysmal sac had no thrombus and pathologic finding was compatible with congenital origin.

  • PDF

생리식염수의 재료표면에의 분출에 의한 이중튜브의 응혈 방지 (PREVENTION OF MURAL THROMBUS IN POROUS INNER TUBE OF DOUBLE-LAYERED TUBE BY SALINE PERFUSION)

  • 김승수;박준부
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1993년도 추계학술대회
    • /
    • pp.110-113
    • /
    • 1993
  • An in vitro experiment under laminar non-pulsatile blood flow and an acute canine ex vivo femoral A-V series shunt experiment were undertaken to investigate the effectiveness of saline perfusion through pores of porous tubes to prevent formation of mural thrombus. PS/SBR porous tubes were used for the in vitro experiment. Commercially obtained ePTFE porous tubes were etched by sodium naphthalenide, and the etched tubes were used for the ex vivo experiment. According to the results of the in vitro experiment, mural thrombus on the surface of the porous tribe could be prevented by the saline perfusion. Adhered blood cells decreased semi-logarithmically with increased perfusion rate (up to $0.022\;ml/min-cm^2$) of isotonic saline solution. According to results of the ex vivo experiment, mural thrombus decreased with increased perfusion rate (upto $0.060\;ml/min-cm^2$).

  • PDF

전교통동맥류 내부 유동 전산해석을 통한 낮은 벽면 전단 응력 영역 발달 분석 (Evolution of Low Wall-Shear Stress Area in Anterior Communicating Artery Aneurysm)

  • 국윤혁;권태호;문성득;김동민;황진율;배영오
    • 한국가시화정보학회지
    • /
    • 제20권2호
    • /
    • pp.45-54
    • /
    • 2022
  • We analyzed the low wall-shear stress area in the intracranial aneurysm that occurred at an anterior communicating artery with a special emphasis on vortical structures close to the wall. We reconstructed the aneurysm model from patient CTA data. We assumed blood as an incompressible Newtonian fluid and treated the blood vessel as a solid wall. The pulsatile boundary condition was applied at the inlet of the anterior cerebral artery. From the instantaneous flow field, we computed the histogram of the wall-shear stress over the aneurysm wall and found the low wall-shear stress event (< 0.4 Pa). This extreme event was due to the low wall-shear stress area that occurred at the daughter sac. We found that the merging of two vortices induced the low wall-shear stress area; one arises from the morphological characteristics of the daughter sac, and the other is formed by a jet flow into the aneurysm sac. The latter approaches the daughter sac, which ultimately leads to the strong ejection event near the daughter sac.

인공판막 후부 공동부가 판막의 수력학적 성능에 미치는 영향 (The Effects of Distal Sinus on the Hydrodynamic Performance of the Prosthetic Heart Valves)

  • 이계한;서종천
    • 대한의용생체공학회:의공학회지
    • /
    • 제19권3호
    • /
    • pp.297-303
    • /
    • 1998
  • 판막 후부의 공동부는 판막의 닫힘 거동과 판막 주위의 혈류 유동장을 변화시켜 인공 판막의 수력학적 성능에 영향을 미칠 수 있다. 계식 이엽 판막(SJMV), 폴리머 단엽 판막(MLPV), 폴리머 삼엽 판막(FTPV)을 판막 후부에 공동부가 있는 시험부와 공동부가 없는 직관형 시험부에 설치하여 모의 순환 장치에서 판막의 수력학적 성능을 평가하였다. 판막의 누수량은 공동부가 있는 시험부에서 약간 작았고, 수축기 평균 압력강하는 크게 나타났으나 통계적으로는 큰 차이가 없었다. 따라서 판막 후부의 공동부는 판막의 수력학적 성능에 큰 영향을 나타내지 않았다. 유량 파형의 해석 결과 판막 후부 공동부는 MLPV에서는 판막의 닫힘에 큰 영향을 주지 않았으나, SJMV에서는 판막의 닫힘이 일찍 시작하게 하였고 이 영향은 FTPV에서 더욱 크게 나타났다. FTPV는 공동부가 있는 시험부에서 역류 최대 유량이 감소하였으므로 판막 후두에 공동부는 판막의 급격한 닫힘에 의한 역류 제트의 발생을 감소시키리라 기대된다.

  • PDF

Correct Closure of the Left Atrial Appendage Reduces Stagnant Blood Flow and the Risk of Thrombus Formation: A Proof-of-Concept Experimental Study Using 4D Flow Magnetic Resonance Imaging

  • Min Jae Cha;Don-Gwan An;Minsoo Kang;Hyue Mee Kim;Sang-Wook Kim;Iksung Cho;Joonhwa Hong;Hyewon Choi;Jee-Hyun Cho;Seung Yong Shin;Simon Song
    • Korean Journal of Radiology
    • /
    • 제24권7호
    • /
    • pp.647-659
    • /
    • 2023
  • Objective: The study was conducted to investigate the effect of correct occlusion of the left atrial appendage (LAA) on intracardiac blood flow and thrombus formation in patients with atrial fibrillation (AF) using four-dimensional (4D) flow magnetic resonance imaging (MRI) and three-dimensional (3D)-printed phantoms. Materials and Methods: Three life-sized 3D-printed left atrium (LA) phantoms, including a pre-occlusion (i.e., before the occlusion procedure) model and correctly and incorrectly occluded post-procedural models, were constructed based on cardiac computed tomography images from an 86-year-old male with long-standing persistent AF. A custom-made closed-loop flow circuit was set up, and pulsatile simulated pulmonary venous flow was delivered by a pump. 4D flow MRI was performed using a 3T scanner, and the images were analyzed using MATLAB-based software (R2020b; Mathworks). Flow metrics associated with blood stasis and thrombogenicity, such as the volume of stasis defined by the velocity threshold ($\left|\vec{V}\right|$ < 3 cm/s), surface-and-time-averaged wall shear stress (WSS), and endothelial cell activation potential (ECAP), were analyzed and compared among the three LA phantom models. Results: Different spatial distributions, orientations, and magnitudes of LA flow were directly visualized within the three LA phantoms using 4D flow MRI. The time-averaged volume and its ratio to the corresponding entire volume of LA flow stasis were consistently reduced in the correctly occluded model (70.82 mL and 39.0%, respectively), followed by the incorrectly occluded (73.17 mL and 39.0%, respectively) and pre-occlusion (79.11 mL and 39.7%, respectively) models. The surfaceand-time-averaged WSS and ECAP were also lowest in the correctly occluded model (0.048 Pa and 4.004 Pa-1, respectively), followed by the incorrectly occluded (0.059 Pa and 4.792 Pa-1, respectively) and pre-occlusion (0.072 Pa and 5.861 Pa-1, respectively) models. Conclusion: These findings suggest that a correctly occluded LAA leads to the greatest reduction in LA flow stasis and thrombogenicity, presenting a tentative procedural goal to maximize clinical benefits in patients with AF.

Rheogram으로 본 실혈시 신장혈액유통 변화 (Rheographic View of the Change in the Renal Blood Flow in Acute Hemorrhage)

  • 장세구;신동훈
    • The Korean Journal of Physiology
    • /
    • 제5권1호
    • /
    • pp.59-69
    • /
    • 1971
  • Studies were undertaken on the changes in the renal blood flow by relating them with the alterations in the amplitudes in the rheogram of rabbits. The changing pattern of the electrical conductivity was recorded by means of the needle electrodes inserted into the kidney and the surrounding aluminium foil which was grounded. The Impedance Rheograph manufactured by the Narco Company was used. The small artifact which persisted after ligation of the renal vessels was subtracted from the value obtained in each pulsatile wave in the rheogram. The animals were nembutalized intravenously, 30 mg/kg. A plastic canule was inserted into the carotid artery and the arterial blood pressure was monitored continuously with the pressure transducer connected to the physiograph. Stepwise bleedings were performed on the animal. The first bleeding was between 13 to 18 ml in the amount, and it was folowed by consecutive hemorrhages, 5 or 10 ml each time. The total amount of bleeding was summed as much as 1.5-2% of the body weight. Two minutes fter each bleeding th arterial blood pressure, ECG and the rheogram were taken. That was the necessary time to obtain the stabilized picture of each parameter. After closing the bleeding process, the shed blood was retransfused into the animal and the response in the renal blood flow was observed as well as the arterial blood pressure. Particularly the presence or absence of the autoregulatory mechanism in the situation of the hemorrhage was also studied. The results obtained were as follows: 1. In 7 cases out of 22, that was about one third of the total number of experiments, the autoregulatory mechanism of the renal blood flow persisted even in acute hemorrhage, and the decreases in the renal blood flow were less than 10% of the control values even when the arterial blood pressure dropped to 66-87% of the original value obtained before the bleeding. 2. Because of the stepwise bleeding the exact blood pressure at which the renal blood flow reduced as much as one third of the control value could not be obtained. However, the results revealed that the approximate pressure, expressed as percentage of the control value, was 50-60% in 3 cases, 61-70% in 4 cases and 71-80% in 8 cases. In one case the decrease in the renal blood flow exceeded one third of the control value before the pressure dropped to 80% of the control. 3. In 19 cases the decreases in the renal blood flow exceeded one half of the control values by hemorrhage. Then the arterial blood pressure revealed less than 40% of the control value in 6-cases. In 2 cases the pressure was 51-60% of the control pressure. In 5 cases the range of bleed pressure was 61-70%, and in e remaining 6 cases the pressure ranged from 71 to 80% of e control value. 4. Out of 15 cases of retransfusion after definite decreases in the renal blood flow loller·ing the hemorrhage, 9 cases restored their renal blood flow. On the contrary 6 cases showed low values even when the shed blood was retransfused. 5. Theories concerning the mechanism of the autoregulation of the renal blood flow were reviewed for the purpose of explanation of the results obtained. However, there are much to be done before greater satisfaction

  • PDF

Hemodynamic Interpretation of Various Extraanatomical Bypasses: Clinical & Engineering Views

  • Lee, Byung-Boong;Kim, Young-Wook;Suh, Sang-Ho;Roh, Hyung-Woon;Kim, Dong-Ik;Yoo, Sang-Sin;Cho, Min-Tae;Huh, Sung
    • International Journal of Vascular Biomedical Engineering
    • /
    • 제1권1호
    • /
    • pp.32-40
    • /
    • 2003
  • Axillo-bifemoral (Ax-Fem) bypass are now well accepted for bilateral iliac artery occlusion as the second best option. This extra-anatomical (unnatural) bypasses, however, have various hemodynamic liabilities affecting the patency. Hemodynamic conditions of each different type of Ax-Fem bypass were assessed with computer simulation model to determine the hemodynamically more sound type. Simulation models of five different types of Ax-Fem bypass were constructed. Our investigation based on the computer simulation models have shown distinct differences between two most popular Lazy-S type and Inverted-C type on the distribution of flow volume, shear stress and recirculation zone, etc., though both types have shown similar clinical results. Lazy-S type has shown better hemodyanmic status than inverted-C type. The theoretical advantage of "Lazy-S" type has never been adequately proved for its superiority clinically over the inverted-C type. Inverted-C type is now in more favor with clinically better results in spite of many hemodynamic liabilities including retrograde flow to the branching graft. The improvement of over-all long-term patency rate of various extra-anatomical bypasses is still warranted through proper correction of the hemodynamic liability. Even though clinical outcome of the extra-anatomical bypass has been equal regardless of the type of crossover femoral graft configuration, there are distinct differences on the hemodynamic characteristics among various types of configuration. Further hemodynamic study in the pulsatile flow status is warranted to correct hemodynamic defects with proper modification of various hemodynamic factors of each model.

  • PDF

오메가 3 지방산이 뇌혈류 및 혈관저항에 미치는 영향: 예비연구 (The Effect of Omega-3 Fatty Acid Supplementation on Cerebral Blood Flow and Vascular Resistance: A Preliminary Study)

  • 허재혁;원혜연;임동규;김정희;김희태;안진영
    • Annals of Clinical Neurophysiology
    • /
    • 제17권2호
    • /
    • pp.68-72
    • /
    • 2015
  • Background: The effects of omega-3 polyunsaturated fatty acids (PUFAs) on cerebral vessels have not been clarified until now. Thus we investigated the efficacy of omega-3 PUFAs supplementation on cerebral blood flow velocity and vascular resistance via transcranial doppler (TCD). Methods: Consecutive twenty patients (13 male and 7 female) with at least 1 cerebrovascular risk factor or a known cerebrovascular disease were enrolled. Patients were treated with omega-3 PUFAs (1 g, two times per day) for 12 weeks. Cerebral blood flow velocity, resistance index, and pulsatile index were checked before and after 12 weeks of treatment using TCD. Results: The change of resistance index in right MCA (from $0.58{\pm}0.07$ to $0.55{\pm}0.07$, p = 0.042) and left PCA (from $0.56{\pm}0.07$ to $0.53{\pm}0.06$, p = 0.037) showed significant improvement after 12 weeks of omega-3 PUFAs treatment. The changes in other vessels, however, failed to show any significant changes compared to the baseline. Conclusions: Omega-3 PUFAs treatment showed feasible efficacies for cerebral vascular resistances in this open label trial. To confirm these results, larger samples of patients and longer period of follow-up is warranted.