• Title/Summary/Keyword: Pulmonary angiography

Search Result 109, Processing Time 0.022 seconds

Surgical Intervention of the Complications of Cardiac Catheterization (외과적 치료가 필요했던 심도자 합병증에 대한 임상적 고찰)

  • Lee, Young;Park, Kyung-Sin;Park, Jin-Seog;Lim. Seung-Pyung;Kim, Eung-Joong
    • Journal of Chest Surgery
    • /
    • v.28 no.6
    • /
    • pp.606-609
    • /
    • 1995
  • We have experienced ten cases of emergent operation for the complications of cardiac catheterization during the period from 1985 to September 1994.Catheterization was done for the evaluation of the cardiac or vascular problem in 8 cases and 2 cases of neurosurgical problem. The extracardiac injection of contrast material have occurred in 3 cases[primum ASD,Trilogy,VSD . Six cases were unable to remove the catheter from femoral artery or vein. The catheters were knotted, coiled, impacted or broken. An embolectomy was done 40 years old man who suffered from chronic left subclavian artery obstruction a day after angiography. Open heart surgery was performed in 5 cases of cardiac perforation,impacted catheter in left inferior pulmonary vein and broken catheter of VSD. Arteriotomy was done in 4 cases to remove the knotted and coiled catheter. There was no complication or mortality for the emergent operation.

  • PDF

Concurrent Patent Ductus Arteriosus and Congenital Extrahepatic Portosystemic Shunt with Suspected Portal Vein Aplasia in a Dog

  • Chae, Soo-young;Cho, Yu-gyeong;Lee, Young-won;Choi, Ho-jung
    • Journal of Veterinary Clinics
    • /
    • v.34 no.4
    • /
    • pp.283-286
    • /
    • 2017
  • A 4-month-old, female Maltese dog was referred with continuous heart murmur. Patent ductus arteriosus was diagnosed via radiography and echocardiography. The patient was untreated because of client's refusal. After 13 months, the dog was referred again with seizure and salivation. Laboratory examination revealed increased liver enzymes, hyperammonemia and decreased total cholesterol and total protein. Microhepatica was identified on abdominal radiography. CT angiography showed a shunt vessel that originated from the portal trunk to the prehepatic caudal vena cava and patent ductus arteriosus connecting proximal descending aorta with the main pulmonary artery. No portal vasculature toward liver is observed after shunt vessel. The patient was diagnosed as concurrent patent ductus arteriosus and congenital extrahepatic portosystemic shunt with suspected portal vein aplasia. In human, cardiac malformations are frequently observed in patients with congenital extrahepatic portosystemic shunt with portal vein aplasia. This report described concurrent patent ductus arteriosus and congenital extrahepatic portosystemic shunt with suspected portal vein aplasia in a dog.

Surgical treatment of coarctation of aorta in infants -Four cases of subclavian flap aortoplasty- (유아에서의 대동맥 축착증 치험 4예)

  • 백광제
    • Journal of Chest Surgery
    • /
    • v.19 no.3
    • /
    • pp.506-514
    • /
    • 1986
  • Coarctation of aorta is rather common congenital cardiovascular defect in the western countries, but it is known to be rare in Korea. And no coarctation of Aorta has been reported and operated upon during early infancy in Korea. During 4 months period from May 1984 to September 1984, four small infants of coarctation of aorta were seen and treated surgically by subclavian flap aortoplasty in Guro Hospital, Korea University. All infants were male, ranging from 7 days to 54 days old [mean 29 days], weighing between 3.2 Kg and 5.0 Kg [mean 4.1 Kg], and all were in congestive heart failure. Examination of the femoral artery pulse gave in all cases clues to the diagnosis. By Two dimensional echocardiogram, detail anatomical features as well as the diagnosis were revealed and associated anomalies, for example, ventricular septal defect could be seen. Besides one case of isolated coarctation of aorta, other three infants had associated VSD. The 3 patients with VSD were treated by pulmonary artery banding in addition to aortoplasty. The postoperative course were smooth in all patients. In conclusion, coarctation of aorta may not be so rare in Korea as we thought previously. The importance of femoral pulse examination can not be overemphasized for the diagnosis. As we experienced, two-dimensional echocardiography in most cases can substitute those invasive examinations such as angiography and catheterization which carry difficulty and risk in infants.

  • PDF

Automatic Detection of Pulmonary Embolism in Spiral CT Angiography (나선형 CT 혈관촬영의 폐색전증 자동 검출)

  • Han, Jae-Bok;Hong, Sung-Hoon;Kim, Soo-Hyung;Lee, Guee-Sang
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2004.05a
    • /
    • pp.703-706
    • /
    • 2004
  • 나선형 CT 혈관촬영에서 획득한 영상의 분석를 통해서 폐색전증이 의심되는 부위를 자동으로 검출하는 방법으로, 연구 대상은 20명의 환자를 대상으로 분석하였으며 CT 검사 후 방사선과 의사가 정상소견을 받은 환자 5명과 폐색전증이 있는 판독소견을 가진 15명을 대상으로 비교 분석하였다. CT 검사하는 동안에 조영제를 투입하면, 폐색전증이 발생한 부위는 조영제 양과 분포가 불균등하여 명암값이 낮게 검출된다. 검출방법으로는 전처리 작업으로 폐영역만을 분할하고, 분할된 폐영역에서 혈관을 찾기 위해 모폴로지기법를 적용하여 세선화(thinning) 작업을 진행한다. 다음 공정으로는 경계선을 찾아 local watershed를 적용하여 혈관을 검출하고, 검출된 혈관내에서 원형모델을 적용하여 모폴로지(morphology)을 통해 국소 부위의 미세한 농도변화를 인지하여 색전이 발생한 영역을 자동검출하였다. 본 논문의 자동검출시스템에서는 색전증이 있는 경우에 true positive의 발생빈도는 case 당 4.5개가 검출되었다. 정상인의 경우에도 혈류의 흐름, 혈류의 분기점, 노이즈로 인한 false positive의 빈도는 case 당 2.6개가 발생하여 전체적으로 false positive는 5.2개가 검출되었다. 본 논문은 false positive의 비율이 높게 검출되었지만 폐영역 CT 검사의 컴퓨터지원진단시스템(computer aided diagnosis)의 향후 연구과제에 방향을 제시할 수 있을 것이라 사료된다.

  • PDF

Assessment of Two Clinical Prediction Models for a Pulmonary Embolism in Patients with a Suspected Pulmonary Embolism (폐색전증이 의심된 환자에서 두 가지 폐색전증 진단 예측 모형의 평가)

  • Park, Jae Seok;Choi, Won-Il;Min, Bo Ram;Park, Jie Hae;Chae, Jin Nyeong;Jeon, Young June;Yu, Ho Jung;Kim, Ji-Young;Kim, Gyoung-Ju;Ko, Sung-Min
    • Tuberculosis and Respiratory Diseases
    • /
    • v.64 no.4
    • /
    • pp.266-271
    • /
    • 2008
  • Background: Estimation of the probability of a patient having an acute pulmonary embolism (PE) for patients with a suspected PE are well established in North America and Europe. However, an assessment of the prediction rules for a PE has not been clearly defined in Korea. The aim of this study is to assess the prediction rules for patients with a suspected PE in Korea. Methods: We performed a retrospective study of 210 inpatients or patients that visited the emergency ward with a suspected PE where computed tomography pulmonary angiography was performed at a single institution between January 2005 and March 2007. Simplified Wells rules and revised Geneva rules were used to estimate the clinical probability of a PE based on information from medical records. Results: Of the 210 patients with a suspected PE, 49 (19.5%) patients had an actual diagnosis of a PE. The proportion of patients classified by Wells rules and the Geneva rules had a low probability of 1% and 21%, an intermediate probability of 62.5% and 76.2%, and a high probability of 33.8% and 2.8%, respectively. The prevalence of PE patients with a low, intermediate and high probability categorized by the Wells rules and Geneva rules was 100% and 4.5% in the low range, 18.2% and 22.5% in the intermediate range, and 19.7% and 50% in the high range, respectively. Receiver operating characteristic curve analysis showed that the revised Geneva rules had a higher accuracy than the Wells rules in terms of detecting PE. Concordance between the two prediction rules was poor ($\kappa$ coefficient=0.06). Conclusion: In the present study, the two prediction rules had a different predictive accuracy for pulmonary embolisms. Applying the revised Geneva rules to inpatients and emergency ward patients suspected of having PE may allow a more effective diagnostic process than the use of the Wells rules.

Surgical Angioplasty of Left Main and Proximal Left Anterior Descending Coronary Artery (좌주관상동맥및 좌전하챙지기시부의 수술적 혈관 성형술)

  • 이원용;김응중
    • Journal of Chest Surgery
    • /
    • v.29 no.8
    • /
    • pp.861-866
    • /
    • 1996
  • Surgical angioplasty of isolated stenosis of the left main coronary artery(LMCA) restores a more physiologic flow to the myocardium, allows percutdneous transluminal coronary angioplasty (PTCA) of distal coronary stenoses at a later stage, and is a less time consuming and convenient procedure than the conventional coronary artery bypass grafting(CABG) . Between Jul. 1994 and Dec. 1995, 7 surgical angioplasty had been performed. LMCA stenoses involved ostium in 2 patients, middle third in 3, and dis- tal third in 2. In 2 patients, the origin of left anterior descending coronary artery was involved in conjunction with LMCA. T e additional coronary artery stenoses were found in 2 cases. One patient was emergently operated after coronary angiography following his cardiac arrest. LMCA was approached anteriorly in all patients. The pulmonary artery was transected in 3 patients for a better exposure. The onlay patch consisted or autologous or bovine pericardium. There was no postoperative myocardial infarction or mortality. Left ventricular functions were well preserved in all patients. Postoperative coronary angiography revealed widely patent LMCA in 5 cases, and mild narrowing of distal anastomotic sites in 2 cases. Provided that well defined indications are followed correctly, surgical angioplasty can be a safe alternative to conventional CABG.

  • PDF

Clinical Outcomes of Off-pump Coronary Artery Bypass Grafting (심폐바이패스 없는 관상동맥우회술의 임상성적)

  • Shin, Je-Kyoun;Kim, Jeong-Won;Jung, Jong-Pil;Park, Chang-Ryul;Park, Soon-Eun
    • Journal of Chest Surgery
    • /
    • v.41 no.1
    • /
    • pp.34-40
    • /
    • 2008
  • Background: Off-pump coronary artery bypass grafting (OPCAB) shows fewer side effects than cardiopulmonary by. pass, and other benefits include myocardial protection, pulmonary and renal protection, coagulation, inflammation, and cognitive function. We analyzed the clinical results of our cases of OPCAB. Material and Method: From May 1999 to August 2007, OPCAB was performed in 100 patients out of a total of 310 coronary artery bypass surgeries. There were 63 males and 37 females, from 29 to 82 years old, with a mean age of $62{\pm}10$ years. The preoperative diagnoses were unstable angina in 77 cases, stable angina in 16, and acute myocardial infarction in 7. The associated diseases were hypertension in 48 cases, diabetes in 42, chronic renal failure in 10, carotid artery disease in 6, and chronic obstructive pulmonary disease in 5. The preoperative cardiac ejection fraction ranged from 26% to 74% (mean $56.7{\pm}11.6%$). Preoperative angiograms showed three-vessel disease in 47 cases, two-vessel disease in 25, one-vessel disease in 24, and left main disease in 23. The internal thoracic artery was harvested by the pedicled technique through a median sternotomy in 97 cases. The radial artery and greater saphenous vein were harvested in 70 and 45 cases, respectively (endoscopic harvest in 53 and 41 cases, respectively). Result: The mean number of grafts was $2.7{\pm}1.2$ per patient, with grafts sourced from the unilateral internal thoracic artery in 95 (95%) cases, the radial artery in 62, the greater saphenous vein in 39, and the bilateral internal thoracic artery in 2. Sequential anastomoses were performed in 46 cases. The anastomosed vessels were the left anterior descending artery in 97 cases, the obtuse marginal branch in 63, the diagonal branch in 53, the right coronary artery in 30, the intermediate branch in 11, the posterior descending artery in 9 and the posterior lateral branch in 3. The conversion to cardiopulmonary bypass occurred in 4 cases. Graft patency was checked before discharge by coronary angiography or multi-slice coronary CT angiography in 72 cases, with a patency rate of 92.9% (184/198). There was one case of mortality due to sepsis. Postoperative arrhythmias or myocardial in-farctions were not observed. Postoperative complications were a cerebral stroke in 1 case and wound infection in 1. The mean time of respirator care was $20{\pm}35$ hours and the mean duration of stay in the intensive care unit was $68{\pm}47$ hours. The mean amounts of blood transfusion were $4.0{\pm}2.6$ packs/patient. Conclusion: We found good clinical outcomes after OPCAB, and suggest that OPCAB could be used to expand the use of coronary artery bypass grafting.

Pharmaco-mechanical Thrombectomy and Stent Placement in Patients with May-Thurner Syndrome and Lower Extremity Deep Venous Thrombosis (May-Thurner 증후군과 동반된 하지 심부정맥혈전환자에서 혈전제거술과 스텐트삽입술)

  • Jeon, Yonh-Sun;Kim, Yong-Sam;Cho, Jung-Soo;Yoon, Yong-Han;Baek, Wan-Ki;Kim, Kwang-Ho;Kim, Joung-Taek
    • Journal of Chest Surgery
    • /
    • v.42 no.6
    • /
    • pp.757-762
    • /
    • 2009
  • Background: Compression of the left common iliac vein by the overriding common iliac artery is frequently combined with acute deep vein thrombosis in patients with May-Thurner Syndrome. We evaluate the results of treatment with thrombolysis and thrombectomy followed by stenting in 34 patients with May-Thurner Syndrome combined with lower extremity deep venous thrombosis. Material and Method: The authors retrospectively reviewed the records of 34 patients (mean age: $65{\pm}14$ year old) who had undergone stent insertion for acute deep vein thrombosis that was caused by May-Thurner syndrome. After thrombectomy and thrombolysis, insertion of a wall stent and balloon angioplasty were performed to relieve the compression of the left common iliac vein. Urokinase at a rate of 80,000 to 120,000 U/hour was infused into the thrombosed vein via a multi-side hole thrombolysis catheter. A retrieval inferior vena cava (IVC) filter was placed to protect against pulmonary embolism in 30 patients (88%). Oral anticoagulation with warfarin was maintained for 3 months, and follow-up Multi Detector Computerized Tomography (MDCT) angiography was done at the date of the patients' hospital discharge and at the 6 months follow-up. Result: The symptoms of deep venous thrombosis disappeared in two patients (4%), and there was clinical improvement within 48 hours in twenty eight patients (82%), but there was no improvement in four patients (8%). The MDCT angiography at discharge showed no thrombus in 9 patients (26%) and partial thrombus in 21 (62%), whereas the follow-up MDCT at $6.4{\pm}5.5$ months (32 patients) revealed no thrombus in 23 patients (72%), and partial thrombus in 9 patients (26%). Two patients (6%) had recurrence of DVT, so they underwent retreatment. Conclusion: Stent insertion with catheter-directed thrombolysis and thrombectomy is an effective treatment for May-Thurner syndrome combined with acute deep vein thrombosis in the lower extremity.

Relation between Ablation Execution Time and Radiation Exposure Effect in the Treatment of Atrial-fibrillation using Cryo-balloon and 3D Radio-frequency Ablation (냉각 풍선 절제술과 3D 고주파 절제술을 이용한 심방세동 치료 시 절제술 시행 시간과 방사선 피폭 영향과의 연관성)

  • Seo, Young-Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.4
    • /
    • pp.427-434
    • /
    • 2022
  • Atrial fibrillation treatment includes 3D RFCA and Cryo-balloon ablation. Both procedures have in common that they enter after understanding the structure of the heart using angiography equipment. Therefore, there is a disadvantage that the effect of exposure according to the procedure time can be a threat to both the patient and the operator, so this study aims to confirm the relationship between the total ablation time and the effect of radiation exposure. We used follow-up data (retrospective) from 41 patients who underwent coronary angiography and arrhythmia at the same time from March 2019 to July 2022. The range for total ablation time was based on the recorded data from the start to the end of the total ablation. The end point of 3D RFCA was when the ablation was completed for 4 pulmonary veins, and in the case of Cryo-balloon ablation, the data that succeeded in electrical insulation were included. As a result of analyzing the total ablation time, the time taken for Cryo-balloon ablation was 1037.29±103.66 s, which was 2448.61 s faster than 3D RFCA using 3485.9±405.71 s, and was statistically significant. (p<0.05) As a result of analyzing the total fluoroscopy time, the exposure time for 3D RFCA was 2573.75±239.08 s, which was less by 1717.15 s than the exposure time for Cryo-balloon ablation, 4290.9±420.42 s, and was statistically significant. In the case of total area dose product, 3D RFCA was 59.04±13.1 uGy/m2, which was lower than Cryo-balloon ablation 980.6±658.07 uGy/m2 by 921.56 uGy/m2, which was statistically significant. As the insulation time of the Cryo-balloon ablation is shorter than that of the 3D RFCA, the method using the Cryo-balloon ablation is considered to be effective when the patient's condition is not good and a quick procedure is required. However, in patients with permanent Atrial fibrillation, there is a high probability of structural changes in the heart, so it is considered that 3D RFCA is better than Cryo-balloon ablation, which is difficult to manipulate.

Surgical Angioplasty of the Left Main Coronary Artery Stenosis (좌주관상동맥 협착에 대한 수술적 혈관 성형술)

  • Chung, Sung-Hyuk;Yang, Ji-Hyuk;Kim, Ki-Bong;Ahn, Hyuk
    • Journal of Chest Surgery
    • /
    • v.32 no.5
    • /
    • pp.433-437
    • /
    • 1999
  • Background: Left main coronary artery (LMCA) angioplasty is another option in the surgical treatment for LMCA disease because of its advantages over the conventional coronary artery bypass grafting (CABG). Material and Method: Between July 1994 and December 1997, 15 patients underwent left main coronary angioplasty for the stenoses of LMCA. There were 8 males and 7 females with the mean age of 53.3${\pm}$8.8 years. The locations of the LMCA stenoses were proximal one-third of the LMCA in 9, middle one-third in 1, distal one-third in 3, and the whole length of the LMCA in 2 cases. Nine patients had peripheral coronary lesions in addition to the LMCA stenosis. The LMCA was approached anteriorly with or without transsection of the main pulmonary artery. The angioplasty was performed with onlay patch widening using an autologous pericardium (14 cases) or saphenous vein (1 case). Additional graftings were required in 9 cases, and both LMCA angioplasty and right coronary ostial angioplasty were done in 1 case. Result: There was no operative mortality. One case needed redo CABG due to the stenosis of the angioplasty site which developed 4 months postoperatively. Coronary angiography was performed in 8 cases one year postoperatively, and revealed good patency of the angioplasty site except for one who showed 50% stenosis at the angioplasty site. No patient complained of angina with a mean follow up of 23${\pm}$11 months. Conclusion: Surgical angioplasty of the LMCA stenosis can be performed in selected cases with safety and good mid-term results.

  • PDF