• Title/Summary/Keyword: Pull-out technique

Search Result 61, Processing Time 0.029 seconds

A Kinematic Analysis of Snatch Technique in Weight-Lifting (역도 인상동작의 운동학적 분석)

  • Moon, Young-Jin;Song, Joo-Ho;Kim, Ji-Seob
    • Korean Journal of Applied Biomechanics
    • /
    • v.14 no.2
    • /
    • pp.41-55
    • /
    • 2004
  • This study analyzed snatch technique in weight-lifting performed by female gold, silver, and copper medalists at the 75kg level in the 2002 Pusan Asian Games and obtained the following conclusions. 1. KSH used more extensor in the waist than those in ankles, knees, or hip joints during the second pull, So further training is required to manifest both each of joints and waist extensor effectively and thus for the line from shoulders through barbell to hip joints to form a smooth vertical pattern. 2. Contrary to those in other countries, Korean athlete KSH tended to be swift in starting but slow in the second pull section, showing less effectiveness in movement during the second pull; therefore, they must try to exert a swift movement in lockout. 3. KSH showed slowdown in the speed, which was a factor interfering with performance during second pull, despite the great maximum speed of moving barbell. It is important to use barbell sufficiently not to reduce the speed of vertical movement but rather to keep the speed increasing. 4. KSH, who kept doing inefficient movements such as failure to perform swift lockout after lifting the heel at the maximum angle of lower limbs, needs to reduce this meaningless extension of ankles, knees, or hip joints to exert energy effectively.

Arthroscopic Pull-out Wire Fixation Using Cannulated Screw of Tibial Eminence Fractures (도관 나사못을 이용한 경골 과간 융기 골절의 관절경적 견인 봉합술)

  • Kim, Jong-Min;Kim, Hyung-Gyu;Park, Byeong-Mun;Song, Kyeong-Seop;Jung, Sung-Hoon;Noh, Haeng-Kee;Yoon, Jong-Joo
    • Journal of the Korean Arthroscopy Society
    • /
    • v.13 no.3
    • /
    • pp.254-258
    • /
    • 2009
  • Tibial eminence fracture is caused by distortion, excessive flexion and extension, varus and valgus injury of the knee joint in the form of avulsion fracture. A failure over the exact anatomical reduction of fragment can lead to instability and limitation of joint motion. Recently, a variety of arthroscopic assisted reduction and fixation technique have been used. In the tibial eminence fracture, we created an arthroscopic pull-out wire fixation technique using a cannulated screw that is easy and more convenient than in the conventional technique. So we report this technique with a review of current literatures.

  • PDF

Field Pullout Tests and Stability Evaluation of the Pretension Soil Nailing System (프리텐션 쏘일네일링 시스템의 현장인발시험 및 안정성 평가)

  • Kim, Hong-Taek;Choi, Young-Geun;Park, Si-Sam;Kim, Berm-Suk
    • Journal of the Korean GEO-environmental Society
    • /
    • v.4 no.3
    • /
    • pp.27-40
    • /
    • 2003
  • In the present study, a newly modified soil nailing technology named as the PSN(Pretension Soil Nailing) system is proposed. Effects of various factors related to the design of the pretension soil nailing system, such as the length of a sheathing pipe and the fixed cone, are examined throughout a series of the displacement-controlled field pull-out tests. 9 displacement-controlled field pull-out tests are performed in the present study and the pretension forces are also evaluated based on the measurements. In addition, both short-term and long-term characteristics of pull-out deformations of the newly proposed PSN system are analyzed and compared with those of the general soil nailing system by carrying out the stress-controlled field pull-out tests. A numerical approach is further made to determine a postulated failure surface as well as a minimum safety factors of the proposed PSN system using the shear strength reduction technique and the $FLAC^{2D}$ program. Global minimum safety factors and local safety factors at various excavation stages computed in case of the PSN system are analyzed throughout comparisons with the results expected in case of the general soil nailing system. An efficiency of the PSN system is also dealt with by analyzing the wall-facing deformations and the adjacent ground surface settlements.

  • PDF

The Treatment of Gynecomastia using Ultrasound-Assisted Liposuction with Pull-Out Method or Excision through Periareolar Incision (다양한 술식을 이용한 여성형 유방증의 치료: 초음파 지방흡입술과 풀아웃법 또는 유륜절개를 통한 절제술)

  • Sim, Hyung Bo;Yoon, Sang Yub
    • Archives of Plastic Surgery
    • /
    • v.34 no.2
    • /
    • pp.237-242
    • /
    • 2007
  • Purpose: Gynecomastia is an abnormal increase in the volume of the male breast. Patients affected by gynecomastia with significant glandular enlargement may respond to suction alone and/or sharp dissection and excision. The purpose of this report is to introduce the indications and results of authors' two techniques. Methods: The diameter of parenchyme was determined by a pinch test after liposuction. For the parenchymal diameter less than 4 cm, ultrasound-assisted liposuction was performed, in conjunction with the "pull-out technique" to effectively remove the fibrofatty tissue of the male breast through a single 5-7 mm incision. For the parenchymal diameter more than 4 cm, ultrasound-assisted liposuction and excision were applied through 2.5 cm periareolar approach. Results: A total of 94 patients (185 breasts) underwent the operation from October 2000 to October 2003 and mean follow-up period was 12 months. The volume of aspirates ranged from 50 to 450 cc per breast. There were no major complications such as skin flap necrosis. Five reoperations were performed for 1 hypertrophic scar, 2 under-resected and 2 hematoma cases. The patient's satisfaction was high and most of them were pleased with the shape of the breasts and scars. Conclusion: These procedures can minimize scars and reduce the incidence of contour problem such as saucer deformity, and provides consistent results. Patients can return to full activities in 48 hours. It can be offered as an option for the treatment of gynecomastia.

Development of a Screw-Crane System for Pre-Lifting the Sternal Depression in Pectus Excavatum Repair: A Test of Mechanical Properties for the Feasibility of a New Concept

  • Park, Hyung Joo;Rim, Gongmin
    • Journal of Chest Surgery
    • /
    • v.54 no.3
    • /
    • pp.186-190
    • /
    • 2021
  • Background: Pre-lifting of the sternum marked a major turning point in pectus excavatum repair. The author developed the crane technique in 2002 and successfully applied it to more than 2,000 cases using sternal wire stitching. However, blind sternal suturing limited the use of the wire-stitch crane. We propose a novel screw for sternal lifting as a new tool for the crane technique. Methods: We developed a screw system strong enough to withstand the pressure needed for sternum lifting. The screw was designed to have a broader thread to hold the bony tissue securely. The screw's sustaining power was tested using the torsion, driving torque, and axial pull-out tests in a polyurethane block and ex-vivo porcine sternum. Results: The screws were easily driven into the sternum, and the head of the screw was connectable to the table-mounted retractor. In the torsion test, the 2° offset torsional yield was 4.53 N·m (reference value, 1 N·m). In the polyurethane block driving torque test, the maximum torque was 0.98 N·m (reference value, 0.70 N·m). The axial pull-out test was 446 N (reference value, 100 N). The maximum pull-out resistance in the ex-vivo porcine sternum model was 1,516 N. Conclusion: The screw crane was strong enough to sustain the chest wall weight to be lifted. Thus, the screws could effectively replace the sternal wire stitching in crane pre-lifting of the sternum. We expect that application of the screw-crane will be easy and that it will improve the safety and success rate of pectus repair surgery.

Arthroscopic Treatment of Tibial Spine Fracture using Suture Hook and pull-out PDS (Suture Hook과 pull-out PDS를 이용한 경골극 골절의 관절경적 치료)

  • Lee, Young Kuk;Kim, Joon Seok;Sohn, Sung Won
    • Journal of the Korean Arthroscopy Society
    • /
    • v.3 no.2
    • /
    • pp.132-137
    • /
    • 1999
  • Displaced tibial spine fractures need the anatomical reduction of the displaced bone fragment to achieve normal range of motion and anterior stability of the knee joint. The purpose of this paper is to describe details of arthroscopic technique using suture hook and pull-out PDS and to evaluate the clinical results. We report 7 cases who underwent arthroscopic reduction and internal fixation using suture hook and pull-out PDS. All cases had fresh fractures generated within 3 weeks. The follow up period was at average 16.6 months. The fracture union was achieved at average 7.4 weeks. Knee exercise was started 2 weeks after the operation. One of the patients, who had combined injury of posterior cruciate ligament and lateral meniscus, showed limitation of knee movement. But he was underwent the arthroscopic fibrolysis at one year later, he returned to normal range of motion. Arthroscopic treatment of displaced tibial spine fracture using suture hook and pull-out PDS showed good results including rigid fixation and early mobilization. Therefore it is thought to be one of the effective operative techniques in treatment of the tibial spine fractures.

  • PDF

Implementation of VGPO/VGPI Velocity Deception Jamming Technique using Phase Sampled DRFM (위상 샘플방식 DRFM을 이용한 VGPO/VGPI 속도기만 재밍기법 구현)

  • Kim, Yo-Han;Moon, Byung-Jin;Hong, Sang-Guen;Sung, Ki-Min;Jeon, Young-Il;Na, In-Seok
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.25 no.7
    • /
    • pp.955-961
    • /
    • 2021
  • In modern warfare, the importance of electronic warfare, which carries out a mission that using radio wave to find out enemy information or to protect ally information, has increased. Radar jamming technique is one of the most representative techniques of EA(Electronic Attack), it disturbs and deceives enemy radar system in order to secure ally location information. Velocity deception jamming technique, which is one of the radar jamming techniques, generally operate against pulse-doppler radar which use doppler effect in order to track target's velocity and location. Velocity Deception Jamming Technique can be implemented using DRFM(Digital Radio Frequency Memory) that performs Frequency Modulation. In this paper, I describe implementation method of VGPO/VGPI(Velocity Gate Pull-Off/Pull-In) velocity deception jamming technique using phase-sampled DRFM, and verify the operation of VGPO/VGPI velocity deception jamming technique with board test under signal injection condition.

The effect of individualization of fiberglass posts using bulk-fill resin-based composites on cementation: an in vitro study

  • Lins, Rodrigo Barros Esteves;Cordeiro, Jairo Matozinho;Rangel, Carolina Perez;Antunes, Thiago Bessa Marconato;Martins, Luis Roberto Marcondes
    • Restorative Dentistry and Endodontics
    • /
    • v.44 no.4
    • /
    • pp.37.1-37.10
    • /
    • 2019
  • Objectives: This study evaluated the bond strength of various fiberglass post cementation techniques using different resin-based composites. Materials and Methods: The roots from a total of 100 bovine incisors were randomly assigned to 5 treatment groups: G1, post + Scotchbond Multi-Purpose (SBMP) + RelyX ARC luting agent; G2, relined post (Filtek Z250) + SBMP + RelyX ARC; G3, individualized post (Filtek Z250) + SBMP; G4, individualized post (Filtek Bulk-Fill) + SBMP; G5, individualized post (Filtek Bulk-Fill Flow) + SBMP. The samples were subjected to the push-out (n = 10) and pull-out (n = 10) bond strength tests. Data from the push-out bond strength test were analyzed using 2-way analysis of variance (ANOVA) with the Bonferroni post hoc test, and data from the pull-out bond strength test were analyzed using 1-way ANOVA. Results: The data for push-out bond strength presented higher values for G2 and G5, mainly in the cervical and middle thirds, and the data from the apical third showed a lower mean push-out bond strength in all groups. No significant difference was noted for pull-out bond strength among all groups. The most frequent failure modes observed were adhesive failure between dentine and resin and mixed failure. Conclusions: Fiberglass post cementation using restorative and flowable bulk-fill composites with the individualization technique may be a promising alternative to existing methods of post cementation.

The Effect of snatch technique improvement for men weightlifter of feedback support through quantity analysis by periods (주기적 정성적분석을 통한 훈련목표 제공이 남자 역도 인상기술 향상에 미치는 영향)

  • Moon, Young-Jin;Ryu, Jung-Hyun;Lee, Soon-Ho
    • Korean Journal of Applied Biomechanics
    • /
    • v.14 no.2
    • /
    • pp.69-83
    • /
    • 2004
  • The purpose of this study is searching for technical merits and demerits of each weight lifting player through qualitative motion analysis system. Moreover, It is also analysis the repeating the establishment of exercise purpose and studying for the effect of the field adaptation. The subject of this study was five male weight lifting players who have been engaged in Korean Delegation Team. The institution of exercise target was made through two times qualitative analysis and the result of studying for the effect of the field adaptation was produced before offering feedback. Moreover, two time analysis added after offering feedback. All analysis was based on 2-D visual analysis. The results of this study are as follows: 1. Maximal barbell moving speed in starting phase was decreased after offering feedback. This result implies advancement of technical skills after offering feedback. 2. From starting posture to 앉아받기, forward and backward moving distance of hip joint was decreased after offering feedback in all subjects. This result represents advancement of technical skills after offering feedback. 3. In terms of pull phase, forward and backward moving distance of hip and shoulder joint was decreased after offering feedback in all subjects. This result represents advancement of technical skills after offering feedback. 4. In terms of pull phase, the difference of horizontal value of coordinates was decreased after offering feedback in all subjects. This result represents advancement of technical skills after offering feedback. 5. In terms of pull phase, the motion range of hip joint was decreased after offering feedback in three of five subjects and this represents advancement of technical skills after offering feedback. However, the rest of them were not variable or narrow decreasing. This result represents that feedback system could not brought tremendous effects. 6. From apex point of barbell to 앉아받기, the difference of barbell height was decreased after offering feedback in three of five subjects and this represents advancement of technical skills after offering feedback. However, the rest of them weren't variable or narrow increasing. This result represents that feedback system could not brought tremendous effects. 7. In terms of last-pull phase, the angular velocity of knee joint was increased after offering feedback in four of five subjects and this represents advancement of technical skills after offering feedback. However, the rest of them, only one subject, decreased. This result represents that feedback system could not brought tremendous effects. 8. In terms of last-pull, the conversional tendency of maximal extension to flextion came out all but simultaneously without offering feedback in four of five subjects. This is well-performed technique. Only one subject, however, could not use power effectively because the fact that his maximal extension came out in serial, from ankle to knee and waist means dispersion of power. In addition to, after offering feedback, only one subject made increasing the maximal extension of knee in last-pull and this result represents advancement of skills after offering feedback. However, the rest of them could not make meaningful development after offering feedback. 9. It might be assumed that searching for technical merits and demerits of each weight lifting player through qualitative motion analysis system could improve player's skill.