• 제목/요약/키워드: Pull-out behavior

검색결과 192건 처리시간 0.025초

철근 콘크리트 보-기둥 외측 접합부에 적용된 강섬유의 효과에 관한 실험연구 (An Experimental Study on the Effects of Steel Fibers used at R/C Exterior Joints)

  • 최기봉;오종한;김재
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제2권3호
    • /
    • pp.188-193
    • /
    • 1998
  • An experimental study was performed on the pull-out behavior of 90-deg standard hooks from exterior beam-column connections. The effects of lateral confinement and fiber reinforcement of joint area were investigated. It was concluded ; (1) Substitution of the transverse column (confining) reinforcement with steel fibers at the joint region effectively reduces the extent of cracking in exterior joints caused by pull-out of hooked bars; and (2) The strength and ductility of hooked bars under pull-out forces are positively influenced by substituting the conventional confining reinforcement of exterior joints with steel fibers. Application of steel fibers to exterior joints seems to be an effective technique for improving the anchorage conditions of hooked bars, and also for reducing the congestion of reinforcement in exterior beam-column connections.

  • PDF

콘크리트 표면처리와 가열조건에 따른 섬유쉬트와 콘크리트의 부착강도에 관한 연구 (A Study on Bond Strength between Fiber Sheet and Concrete for Concrete Surface Preparation and Heating Condition)

  • 안상호
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제6권4호
    • /
    • pp.201-207
    • /
    • 2002
  • An advanced fiber sheet has been widely used for strengthening of the concrete structures due to its excellent properties such as high strength and light weight. Bond strength is very important in strengthening the concrete structures using an advanced fiber sheet. This research examines the bond behavior between fiber sheet and concrete, investigates the bond strength by the direct pull-out test and the tensile-shear test. To obtain the tensile-shear strength a double-face shear type bond test is conducted. The primary test variables are the types of concrete surface roughness (disk-grinding/chipping) and retrofitting methods (bonding/injection). Thirty specimens were tested to evaluate the bond strength. It is shown that the average bond strength between fiber sheet and concrete by the direct pull-out test and the tensile-shear test is $22.3{\sim}23.1kgf/cm^2$ $17.92{\sim}19.75kgf/cm^2$, respectively.

강섬유보강 시멘트 복합체의 섬유인발거동에 따른 인장성능 평가에 관한 실험적 연구 (An experimental study on the tensile performance evaluation of steel fiber reinforced cementitious composites according to fiber pull-out behabior)

  • 이예찬;김규용;남정수;이상규;서동균;유하민
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2020년도 가을 학술논문 발표대회
    • /
    • pp.155-156
    • /
    • 2020
  • The purpose of this study is to evaluate tensile performance of cementitious composites reinforced with steel fiber. The tensile performance of steel fiber reinforced cementitious composites is related to the tensile performance of reinforced fiber, and depends on the fracture or pull-out of fiber. Therefore, the tensile performance was compared and analyzed by conducting a direct tensile test on the tensile specimens of cementitious composites reinforced with hook-type steel fiber and amorphous steel fiber.

  • PDF

고성능 팽창재를 이용한 FRP 긴장재의 정착에 관한 연구 (A Study on the Behavior of Non-Metallic Anchoring System for FRP Tendons)

  • 김덕현;조병완;이계삼;김영진
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2001년도 춘계학술발표대회 논문집
    • /
    • pp.23-28
    • /
    • 2001
  • Since non-corrosive Fiber Reinforced Polymer(FRP) tendons have been in increasing use for underground and coastal structures constantly contacted with fresh water or sea water because of their superiority to metallic ones in corrosion-resistance, new non-metallic anchoring system for FRP tendons has been developed and investigated to verify the effectiveness of tendon force, which consist of mainly FRP pipes and Highly Expansive Mortar(HEM). The major factors considered in this experiment were expansive pressures of HEM during its hydration, sleeve lengths and types, and anchoring methods of tendon. New anchoring system were investigated from the pull-out tests. The pull-out procedures of the FRP tendons in the various pipe filled with HEM were analyzed and improved ideas were suggested to develop novel non-metallic anchoring system for FRP tendons The pull-out tests for the FRP tendon and new non-metallic anchoring system were conducted. The results show that non-metallic anchoring system for the FRP tendon has been more stablized due to the gradual expansive pressrure of HEM, as tims goes. Since tile lower stiffness of FRP pipes causes the weakness of anchoring force, it requires the increase of stiffness using a carbon fiber or an increased section area.

  • PDF

정착판 GFRP 근(Rebar)의 모르타르 인발거동에 관한 시험연구 (An Experimental Study on the Pull-Out Behaviors of Headed GFRP Rebar in Mortar)

  • 지효선
    • 한국산학기술학회논문지
    • /
    • 제13권6호
    • /
    • pp.2797-2803
    • /
    • 2012
  • 본 논문은 모르타르에 근입되어 인발하중을 받는 정착판 GFRP 근의 인발거동을 기술하고 있다. 정착판 GFRP 근의 모르타르 시험체를 5개 제작하여 인발시험을 수행하였다. 시험 결과를 검증하기 위해 ANSYS 상용프로그램을 이용한 유한요소해석을 수행하였으며 시험결과와 비교되었다. 시험결과 모르타르에 매입된 정착판 GFRP 근의 파열 파괴강도식은 45도 콘(Cone)파괴 이론 보다는 CCD(Concrete Capacity Design)파괴이론을 적용하는 것이 타당한 것으로 나타났다.

NDB 쏘일네일링 시스템의 거동특성 평가에 관한 실험적 고찰 (An Experimental Study on the Analysis of Behavior Characteristics of the NDB Soil Nailing System)

  • 김홍택;정성필;박시삼;전경식
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.521-528
    • /
    • 2003
  • In this study, a newly modified soil nailing technology called as the NDB(New Down and Board) soil nailing system is introduced. To improve the trafficability, workability, and economical efficiency, SMC(Sheet Molding Compound) board is adopted instead of using the concrete block facing. The SMC board has a distinct advantage of showing a fine view by directly coating with any kind of environmental photos. Composite material properties of the SMC board and cement grout are distinguished features of the NDB soil nailing system. In the present study, both laboratory tests(bending and punching failure tests) and field pull-out tests are carried out to analyze the behavior characteristics of the NDB soil nailing system, including the stress and strain distribution.

  • PDF

프리캐스트 콘크리트 패널 분절 아치 시공을 위한 선설치 앵커의 인발 강도 평가 (Pull-out Capacity of Cast-in-place Anchor for Construction of Precast Concrete Segment Arch)

  • 안진희;임홍재;방진수;전석현
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제24권2호
    • /
    • pp.94-102
    • /
    • 2020
  • 프리캐스트 콘크리트의 장점과 및 석조 아치의 거동을 접목한 콘크리트 패널 분절 아치 시스템은 가설재가 불필요한 시공성을 확보할 수 있는 경제적 시공법이다. 분절된 프리캐스트 콘크리트 패널의 연속 배치로 구성된 아치는 인양 및 시공을 위한 V형-스트립 연결부의 선설치 앵커 설치가 필수적이다. 그러나 좁은 폭과 얇은 두께의 콘크리트 패널은 선설치 앵커의 충분한 묻힘 깊이 확보를 보장할 수 없고 앵커 인발 거동 시 패널의 휨변형을 동반하는 등 앵커 저항성능 확보를 위한 콘크리트 패널의 기하학적 영향이 고려되어야 한다. 따라서 본 연구에서는 프리캐스트 패널과 강재 아웃리거로 구성된 아치구조의 제작시 설치되는 선설치 앵커의 인발 강도 평가를 위한 실험 연구를 수행하였다. 이를 위해 실제 아치 시스템과 동일한 크기의 프리캐스트 콘크리트 패널을 제작하였으며, 선설 앵커의 직경, 앵커 묻힘 깊이, 와이어 매쉬 사용 등의 영향에 따라 총 24개 실험체의 선설치 앵커 인발 강도를 측정하였다. 또한 측정 변수에 따른 설계기준강도 확보 및 파괴 모드 평가를 통해 프리캐스트 콘크리트 패널 분절 아치 구조에 적용 가능한 선설치 앵커의 형태를 결정하였다.

Design Equation for Punching Shear Capacity of SFRC Slabs

  • Higashiyama, Hiroshi;Ota, Akari;Mizukoshi, Mutsumi
    • International Journal of Concrete Structures and Materials
    • /
    • 제5권1호
    • /
    • pp.35-42
    • /
    • 2011
  • In this paper, a design equation for the punching shear capacity of steel fiber reinforced concrete (SFRC) slabs is proposed based on the Japan Society of Civil Engineers (JSCE) standard specifications. Addition of steel fibers into concrete improves mechanical behavior, ductility, and fatigue strength of concrete. Previous studies have demonstrated the effectiveness of fiber reinforcement in improving the shear behavior of reinforced concrete slabs. In this study, twelve SFRC slabs using hooked-ends type steel fibers are tested with varying fiber dosage, slab thickness, steel reinforcement ratio, and compressive strength. Furthermore, test data conducted by earlier researchers are involved to verify the proposed design equation. The proposed design equation addresses the fiber pull-out strength and the critical shear perimeter changed by the fiber factor. Consequently, it is confirmed that the proposed design equation can predict the punching shear capacity of SFRC slabs with an applicable accuracy.

2차원 모형실험 및 수치해석을 통한 현수교 터널식 앵커리지의 인발거동 특성 분석 (Analysis of Pull-out Behavior of Tunnel-type Anchorage for Suspended Bridge Using 2-D Model Tests and Numerical Analysis)

  • 서승환;박재현;이성준;정문경
    • 한국지반공학회논문집
    • /
    • 제34권10호
    • /
    • pp.61-74
    • /
    • 2018
  • 본 연구에서는 케이블 인발하중이 작용하는 현수교의 앵커리지 종류 중 터널식 앵커리지의 인발거동 특성을 축소모형실험과 수치해석을 통하여 분석하였다. 터널식 앵커리지는 국내외 적용사례가 적고 파괴형태 및 안전율 등 설계기법이 명확히 정립되어 있지 않아 설계기법 개선과 관련한 연구가 필요한 실정이다. 이에 국내 최초로 터널식 앵커리지가 적용된 울산대교를 대상으로 형상 및 구조를 단순화하여 축소모형실험을 수행하였다. 모형실험에서 앵커리지 구체와 주변 암반을 석고혼합물로 구현하였고, 평면 변형률 조건에서 인발 거동 특성을 조사하였다. 모형실험결과 터널식 앵커리지의 최종 인발 파괴모드는 울산대교의 설계시 가정한 바와 달리 쐐기(wedge)형태로 나타났다. 이를 검증하기 위해 유한요소해석 프로그램인 ABAQUS를 사용하여 수치해석을 시행하였고, 모형실험결과와 동일한 인발 파괴 거동을 확인할 수 있었다. 수치해석에서는 추가적으로 모형재료의 포아송비 및 주변암반의 강도 변화에 따른 영향을 조사하였다. 그 결과 극한 인발상태까지는 포아송비에 따른 영향이 적은 것으로 나타났고, 주변암반의 강도가 앵커리지 구체의 강도보다 10배 이상 큰 특수한 경우에 한하여 앵커리지가 주변 암반의 경계면을 따라 빠져나오는 소위 플러그(plug)형태의 파괴모드가 발생할 수 있음을 확인하였다.

거친표면 GFRP 보강근의 쪼갬부착파괴강도 및 거동 고찰 (Bond Splitting Strength and Behavior of GFRP Reinforcement with Roughened Surface)

  • 문도영
    • 한국방재학회 논문집
    • /
    • 제11권2호
    • /
    • pp.23-29
    • /
    • 2011
  • 본 연구는 거친 표면을 갖는 GFRP 보강근의 쪼갬에 의한 부착파괴 거동과 파괴강도를 인발실험을 통해 규명하였다. 실험변수로서, 보강근의 직경, 콘크리트 피복 및 콘크리트 압축강도에 대하여 실험을 수행하였으며, 동일한 변수에 대하여 5개의 실험 결과를 평균하여 실험에 대한 오차를 최소화 하였다. 또한 쪼갬에 의한 부착파괴거동을 인발력과 변위결과로부터 고찰하였다. 쪼갬부착파괴강도 결과는 여러 연구자가 제안한 이형철근 및 FRP 보강근의 쪼갬부착파괴강도 평가모델식과 비교하였다. 분석결과, 거친표면을 갖는 GFRP 보강근의 쪼갬부착파괴강도는 Harajli 등(1995)이 제안한 모델을 이용하여 가장 근사하게 평가할 수 있는 것으로 나타났다.