• 제목/요약/키워드: Puffer cylinder

검색결과 14건 처리시간 0.018초

대전류 영역에서의 가스차단기 내의 아크의 자발적인 흐름현상에 따른 에너지 전달의 수치적 해석 (The Study on the Self-Flow Generation Phenomena in a Gas Circuit Breaker)

  • 최재원;최승길;강형부
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 E
    • /
    • pp.1837-1839
    • /
    • 1997
  • This study presents the energy transfer of thermal arc in the circuit breaker with self-generation flow without puffer action. The phenomenon of pressure increase in the cylinder which encloses fixed contact was focused on and rising current stage was considered. Temperature and velocity of arc plasma were calculated by using energy balance equation and the amount of energy transfer due to convective flow was calculated.

  • PDF

이동격자를 이용한 72.5kV${\sim}$800kv 초고압 차단기 유동해석 (CFD Analysis of 72.5kV${\sim}$800kV GIS with Moving Grid)

  • 윤자홍;최병화;이기헉;윤치영;고경석;민병수;박일석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 B
    • /
    • pp.799-801
    • /
    • 2002
  • To develop GIS (Gas Insulated Switchgear), prediction of the flow field including pressure in GIS is very important. The transport phenomena in GIS including arc is also being studied in these days. In this study, to predict the arc behaviour for GIS with voltage rating up to 800kV developed by HHI (Hyundai Heavy Industries Co. Ltd.), the analysis of flow and electric field in GIS were investigated. To simulate the compressible flow in GIS, the CFX, commercial CFD code, was used. The movement of the piston and the electrode of the GIS was simulated with moving grid method, which was superior to the method of varying the property of cells in the aspect of accuracy and convergence of solution. The calculated maximum pressure within the puffer cylinder was matched with experimental data within 5% error. Also, the oscillation of pressure in GIS after the movement of electrode was well predicted.

  • PDF

신차단방식 SF$_{6}$ 가스 차단기의 소전류 차단성능 연구 (Investigation of Small Current Interruption Performance for New Type of Interrupting Chamber in SF$_{6}$ Gas Circuit Breaker)

  • 송원표;권기영;이재성;송기동;김맹헌;고희석
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제54권11호
    • /
    • pp.519-526
    • /
    • 2005
  • This paper presents computer simulation results for developing new type of SF$_{6}$ Circuit Breaker in terms of cold gas flow after small current interruption. This cold gas flows down a nozzle into the chamber of a circuit breaker. There are many difficult problems in analyzing the gas flow due to complex geometry, moving boundary, shock wave and so on. When predicting the dielectric capability of a gas circuit breaker after interruption, the gas pressure and density distributions due to the cold gas must be considered in addition to the electrical field imposed across the gas. A self-coded computational fluid dynamics (CFD) program is used for the simulation of cold gas flow in order to evaluate the electrical field characteristic across open contacts and transient characteristics of insulations after small current interruption.

$SF_6$ 가스절연개폐기의 냉가스유동해석과 전계해석을 기초로 한 차단성능평가 (Circuit Interruption Performance Evaluation of $SF_6$ GIS Based Results of Cold Flow and Electrical Field Analysis)

  • 배동진;송태헌;최영찬;이기주;김익모;강종호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 A
    • /
    • pp.89-91
    • /
    • 1999
  • The performance of circuit interruption of $SF_6$ puffer cylinder type gas circuit breaker(GCB) has been evaluated from the results of electrical insulation strength which is depend on material property, such as $SF_6$ gas density in circuit breaker tank. In order to determine circuit breaker dimension in the safety criteria. electrical field analysis has been done by finite element method. Gas density of concerned area in the circuit breaker has been calculated. In order to predict small current break performance, Electrical field analysis result must be calculated based the results of density from cold flow dynamics. The proposed method has been carried out and evaluated for 362kV class high voltage GIS.

  • PDF