• Title/Summary/Keyword: Public sewage treatment facilities

Search Result 34, Processing Time 0.027 seconds

A study on the management status of public small-scale sewage treatment facilities and the improvement (마을하수도 운영실태 및 개선방안)

  • Shin, Dae-Yewn;Bae, Chul-Ho
    • Journal of environmental and Sanitary engineering
    • /
    • v.23 no.4
    • /
    • pp.55-64
    • /
    • 2008
  • In this study, the management and improvement of public small-scale sewage treatment facilities was investigated. In order to improve the effective management of the operation of small-scale sewage treatment facilities, treatment methods and the problems associated with sewage treatment were carefully addressed based on the data and literature. The investigation results showed that sewer pipes in rural areas should be repaired to prevent sewage from leaking and small-scale operations should be required to have effective management for pollutant loads less than 50%. Also, new methods should be developed for low concentrations of sewage. A law associated with FRP treatment facilities should be established and local governments need to supervise these operations to avoid insufficient and faulty construction. It is recommended that new facilities are built with advanced treatment techniques when the old facility can not comply with nitrogen and phosphorous discharge limits. Moreover, the study shows that nutrient and coliform treatment efficiency improves when abandoned facilities are renovated with the installation of nitrification/denitrification and disinfection processes or another advanced process.

A Study on the Role of Public Sewage Treatment Facilities using Wastewater-based Epidemiology (하수기반역학을 적용한 공공하수처리시설 역할 재정립)

  • Park Yoonkyung;Yun Sang-Lean;Yoon Younghan;Kim Reeho;Nishimura Fumitake;Sturat L. Simpson;Kim Ilho
    • Journal of Korean Society on Water Environment
    • /
    • v.39 no.3
    • /
    • pp.231-239
    • /
    • 2023
  • Public sewage treatment facilities are a necessary infrastructure for public health that treat sewage generated in cities and basin living areas and discharge it into rivers or seas. Recently, the role of public sewage treatment is receiving attention as a place of use of wastewater-based epidemiology (WBE), which analyzes human specific metabolic emissions or biomarkers present in sewage to investigate the environment to which the population is exposed in the water drain. WBE is mainly applied to investigate legal and water-law drug use or to predict and analyze the lifestyle of local residents. WBE has also been applied to predict and analyze the degree of infectious diseases that are prevalent worldwide, such as COVID-19. Since sewage flowing into public sewage treatment facilities includes living information of the population living in the drainage area, it is easy to collect basic data to predict the confirmation and spread of infectious diseases. Therefore, it is necessary to establish a new role of public sewage treatment facilities as an infrastructure necessary for WBE that can obtain information on the confirmation and spread of infectious diseases other than the traditional role of public sewage treatment. In South Korea, the sewerage supply rate is about 95.5% and the number of public sewage treatment facility is 4,209. This means that the infrastructure of sewerage is fully established. However, to successfully drive for WBE , research on monitoring and big-data analysis is needed.

A study on the risk assessment of climate crisis adaptation measures in public sewage treatment facilities (공공하수처리시설의 기후위기 적응대책 위험도 평가 연구)

  • Jaekyung Choi;Younsun Lee;Sunghwan Hwang
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.38 no.2
    • /
    • pp.61-68
    • /
    • 2024
  • In the context of the Ministry of Environment's 2022 Climate Change Adaptation Plan for Public Institutions, public sewage treatment plants are one of the important targets for climate change response aimed at sustainable water management. In this study, it is applied a modified methodology to four water regeneration centers (public sewage treatment facilities) in charge of sewage treatment in Seoul to analyze the impacts and risks of climate change and discuss priorities for adaptation measures. The results of the study showed that heavy rains, heat waves, and droughts will be the key impacts of climate change, and highlighted the need for measures to mitigate these risks, especially for facility managers.

Analysis of the cost effectiveness according to T-P standard enforcement of public sewage treatment facilities (공공하수처리시설의 총인기준 강화에 따른 비용효과분석)

  • Jeong, Won-Gu;Rim, Jay-Myung
    • Journal of Industrial Technology
    • /
    • v.31 no.A
    • /
    • pp.135-145
    • /
    • 2011
  • This study was conducted to analyze the cost effectiveness in line with total phosphorus standard enforcement of public sewage treatment facilities. The additional cost for the total phosphorus removal process was calculated to analyze the cost effectiveness of the advanced water purification process. The analysis results showed that the T-P removal by coagulation sedimentation was more efficient than the advanced water purification facilities in terms of facilities investment cost, and if the coagulation filteration was used for T-P removal, the activated carbon process among the advanced water purification techniques was more efficient in terms of facilities investment cost. In this study, the effects of the T-P removal process that will be additionally introduced according to the tightening of the effluent T-P standard were analyzed within a limit. The actual benefits of improved T-P concentration in the water source will provide diverse values, including the leisure water, environment improvement water, eco-system in the water source and industrial water, in addition to the advanced water purification.

  • PDF

Determination of Optimal Livestock Wastewater Treatment Process for Linked Treatment in Sewage Treatment Plant (하수처리장 연계처리를 위한 가축분뇨 최적 처리공정 선정에 관한 연구)

  • Kim, Choong Gon;Shin, Hyun Gon
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.20 no.3
    • /
    • pp.52-59
    • /
    • 2012
  • As the result of reviewing the linked treatment of water quality for treating process at public livestock wastewater treatment facilities for fair selection of the proper linked process in case of linking sewage treatment plant for livestock wastewater, in case of wastewater processed by bio-reactor that is only biologically-treated, the load factor showed relatively high as 1.67%(base on design quality), 2.59%(base on operation quality) regarding COD and 3.69%(base on design quality), 7.67%(base on operation quality) regarding $COD_{Mn}$ but it is judged that there is nearly no influence on the operation of sewage treatment plan. And, in case of oxidized flotation-treated water & biofiltlation-treated water that are the advanced wastewater treatment, the load factor is approximately 1% and there is concern about the installation of excessive facilities in case of installing the advanced wastewater treatment. So, in case of considering the economic efficiency & stable operation of sewage treatment plant S, it is judged to be desirable to link with wastewater processed by bio-reactor that is biologically-treated.

Implementations of Geographic Information Systems on Sewage Management for Water Resources Protection

  • Wu, Mu-Lin;Chen, Chiou-Hsiung;Chou, Wen-Shang;Huang, Hsiu-Lan
    • Proceedings of the KSRS Conference
    • /
    • 2003.11a
    • /
    • pp.1188-1190
    • /
    • 2003
  • Taipei Watershed Management Bureau (WRATB) is a government agency entitled for water resources protection at two major watersheds in order to provide drinking water for about four millions population in Taipei on a sustainable basis. At WRATB, there are two major public sewage treatment facilities which can convert sewage in each watershed into an acceptable state before they were discharged into rivers. More than 82% of household wastewater have been collected and treated by the two public sewage systems. However, households at remote area still need more effective sewage management prescriptions. The objective of this paper is to implement geographic information systems in order to provide more effective approaches that sewage management can be easier and cost effective. ArcIMS was implemented for Internet browsing and map server of those sewage facilities on personal computers, laptop computers. In the open field, ArcPAD was implemented with personal digital assistant (PDA) such that compact flash type's global positioning systems (GPS) and digital camera can be utilized with PDA. All sewage facilities digital files were convert into ArcMap format files. MapObjects and visual BASIC were used to create sewage application modules to meet every single technician personal flavor. ASP.NET was implemented for Internet database manipulations of all sewage databases. Mobile GIS was the key component of GIS applications in the open field for sewage management on a basis of house by house. Houses at remote area, which can not cover by the two public sewage systems, were managed by PDA and laptop computers with GPS and digital camera. Sewage management at Taipei Watershed Management Bureau is easier both in the open field and in the office. Integration of GPS, GIS, and PDA makes sewage management in the open field much easier. ArcIMS, MapObjects, ASP.NET and visual BASIC make sewage management can be done in the office and over Internet.

  • PDF

The Case Study on Performance Measurement Weighting for Efficient Value Engineering Study of Sewage Treatment Facliity (하수처리시설의 효율적인 VE수행을 위한 다단계성능평가 분석)

  • Kim, Dongjin;Park, Jaeil;Lee, Jaehun;Lee, Minjae
    • Korean Journal of Construction Engineering and Management
    • /
    • v.17 no.1
    • /
    • pp.40-47
    • /
    • 2016
  • Recently, the demand of sewage treatment facilities have increased by growing the population growth of city and industrialization. However, most of public sewage treatment facilities lack the preparations of design criteria by increasing sewage water amount in the future. In order to respond to this situation, the government has consistently promoted the sewage treatment construction project. This study conducted a survey targeting residents and sewage treatment facilities, civil engineering a VE project professionals for effectively operating the sewage treatment facilities and improving its value to be built in the future. Based on this survey, this study will introduce the list of performance measurements which can not only save cost but also reflect opinion of users and residents. In addition, using Multi-Level Performance Measurement and AHP analyzed the weights of performance measurement which is more objective than existing things for applying efficient VE process

The Assessment on the Effect of Discharge and Variation of Water Quality from the Sewage Treatment Plants in Seoul (서울시 하수처리장 수질의 변동 및 방류수의 영향 평가)

  • Kwak Mi-Ae;Jung Jong-Heub;Eo Soo-Mi;Lee Hong-Keun
    • Journal of environmental and Sanitary engineering
    • /
    • v.19 no.3 s.53
    • /
    • pp.1-12
    • /
    • 2004
  • This study was conducted to evaluate the variation characteristics of influent and effluent quality from sewage treatment facilities using activated sludge processes and to assess the impact caused by discharge of treated sewage on the receiving water Monthly data of five water quality items (BOD, COD, SS, T-N, T-P) were used to understand the water quality at three sewage treatment plants in Seoul for five years from 1999 to 2003. Concentration differences of water quality parameters were observed between upstream and downstream site at the sewage treatment plant outfall to investigate the impact of discharge in Tan stream and Han river basin. 1. Due to the effect of continuous improvement in sewer system, the concentrations of influent went on increasing generally. 2. Effluent concentrations of BOD, COD and SS showed the trend of a little decreasing, but the trend of increasing in T-N and T-P. 3. In Tan stream basin, the impact of sewage treatment plant discharge was not observed directly, because concentration of discharge was lower than stream water's. But discharges from sewage treatment plants affected water quality at downstream site in Han river, concentration of T-P especially.

A Study on the Regulatory Effect of the Special Water Preservation Area of Lake Paldang Watershed Based on Long-Term Variation of Pollutant Source and Water Quality (수질과 오염원의 장기적 변화를 통한 팔당호 상수원수질보전 특별대책지역 규제효과 분석)

  • Kim, Ho-Sub;Park, Yun-Hee;Kim, Yong-Sam;Kim, Sang-Yong
    • Journal of Korean Society on Water Environment
    • /
    • v.35 no.1
    • /
    • pp.43-54
    • /
    • 2019
  • The objective of this study was to assess the effect of policies on water quality management based on the changes in pollutants and water quality in Special Water Preservation Area (SWPA) of Lake Paldang watershed from 1990 to 2016. The population, total sewage and flow rate of wastewater in SWPA continuously increased from 1990 to 2016, while the location of new facilities for industrial and livestock facilities has been restricted. However, unlike the buffer zone in which industrial and livestock facilities were continuously reduced after implementing of TMDL, it was found that the effect of land-use regulations on industrial and livestock facilities in SWPA were mitigated by the increase in the size of large facilities. Since 1999 when the emission standard of public sewage treatment plants (STP) was changed, the water quality of Lake Paldang has increased despite the increase of pollutant source. Since emission standard of STP changed in 2012 (BOD 5 mg/L, TP 0.2 mg/L), BOD concentration in Lake Paldang has also improved to the level of water quality in the early 1990s where as TP concentration has remained at its lowest since 1990. BOD and TP average discharge concentration of 43 STP (${\geq}500m^3/day$) in 2016 have been maintained $1.7{\pm}0.7mg/L$ and $0.06{\pm}0.02mg/L$ respectively. While the discharged load of STP in SWPA was decreased by the concentration management, the contribution rate to the total discharged load of non-point pollutants increased to 70 % in 2015, and the contribution rate to the point discharged load of individual treatment facilities increased to 80 %.

Combined Treatment of Livestock Wastewater with Sewage Using Phanerochaete chrysosporium PSBL-1 (Phanerochaete chrysosporium PSBL-1을 이용한 축산폐수와 하수의 연계처리)

  • Lee, Soon-Young;Cho, Hong-Sik;Won, Chan-Hee
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.3
    • /
    • pp.286-291
    • /
    • 2006
  • We studied possibility of mixing treatment of livestock wastewater and sewage using Phanerochaete chrysosporium PSBL-1. Our study showed that 97.6% of SS and 95% of T-P removal efficiency was achieved when 2 mL BF02(a coagulant) and 100 mL C-210EL(a cationic polymer) were added to the mixture(2:1, v/v) of livestock wastewater and sewage. We studied treatment characteristic of Phanerochaete chrysosporium PSBL-1, after were mixed pretreated wastewater and sewage by dillution ten times about livestock wastewater. The removal efficiency of NBDCOD(non-biodegradable COD), $NH_3-N$ and T-N was increased according to increase of pH. That is, T-N concentration of effluent was satisfied 60 mg/L by drain water waterqulity standard of livestock wastewater public treatment facilities with 35 mg/L from a lapse of five days at pH 6.7, 51 mg/L from a lapse of three days at pH 8 and 33 mg/L from a lapse of one day at pH 10. Moreover $COD_{Mn}$ concentration of effluent was satisfied 40 mg/L by drain water waterqulity standard of livestock wastewater public treatment facilities after a laps of one day at all pH. Organics and nitrogen concentrations of effluent were higher case with addition of V.A.(veratryl alcohol) than case without addition of V.A.(veratryl alcohol). $COD_{Mn}$ concentration of effluent satisfied drain water qulity standard of livestock wastewater public treatment facilities from a lapse of one day, when C/N rate(3:1) of influent was not controled. T-N satisfied that from a lapse of two days, when C/N rate was controled with $4{\sim}6$.