• 제목/요약/키워드: Proximity measure

검색결과 82건 처리시간 0.035초

A Study on Minimum Number of Ship-handling Simulation Required for Evaluating Vessel's Proximity Measure

  • Jeong, Tae-Gweon;Pan, Bao-Feng
    • 한국항해항만학회지
    • /
    • 제38권6호
    • /
    • pp.689-694
    • /
    • 2014
  • The Korean government has introduced and enforced maritime traffic safety assessment to secure traffic safety since 2010. The maritime traffic safety assessment is needed by law to design a new port or modify an existing one. According to Korea Maritime Safety Act, in the assessment the propriety of marine traffic system consists of the safety of channel transit and berthing/unberthing maneuver, safety of mooring, and safety of marine traffic flow. The safety of channel transit and berthing/unberthing maneuver can be evaluated only by ship-handling simulation. The ship-handling simulation is carried out by sea pilots working with the port concerned. The vessel's proximity measure is an important factor to evaluate traffic safety. The proximity measure is composed of vessel's closest distance to channel boundary and probability of grounding/collision. What is more, the probability of grounding becomes important. According to central limit theorem, a sample has a normal distribution on condition that its size is more than 30. However, more than 30 simulation runs bring about the increase of assessment period and difficulty of employing sea pilots. Therefore this paper is to find out minimum sample size for evaluating vessel's proximity. First sample sets of size of 3, 5, 7, 9 etc. are selected randomly on the basis of normal distribution. And then KS test for goodness of fit and t-test for confidence interval are applied to each sample set. Finally this paper decides the minimum sample size. As a result this paper suggests the minimum sample size of 5, that is, the simulation of more than five times.

태그 궤적 색인을 위한 인식공간 근접성 기법 (The Proximity Scheme of the Perceptual Space for Indexing The Trajectories of Tags)

  • 김동현;안성우
    • 한국정보통신학회논문지
    • /
    • 제13권10호
    • /
    • pp.2140-2146
    • /
    • 2009
  • 태그는 위치정보가 없기 때문에 리더의 식별자를 위치정보로 사용하지만 비연속적인 심볼형 정보이다. 따라서 태그 이동 궤적간의 근접성을 정의하는 것이 어려우며 사용자 질의 처리시 비효율적이다. 본 논문에서는 태그 위치를 표현하기 위하여 인식공간을 정의하고 인식공간 근접성을 제안한다. 인식공간 근접성은 정적 인식공간 근접성과 동적 인식공간 근접성으로 구성되며 이를 이용하여 태그 궤적 간의 근접성을 측정하고 효율적인 색인을 구축할 수 있다. 제안한 태그 이동 궤적 근접성 함수를 평가하기 위해 태그 색인 기법인 IR-tree와 이동체 색인 기법인 $R^*$-tree를 대상으로 성능평가 실험을 수행하였다.

A FULL-NEWTON STEP INFEASIBLE INTERIOR-POINT ALGORITHM FOR LINEAR PROGRAMMING BASED ON A SELF-REGULAR PROXIMITY

  • Liu, Zhongyi;Chen, Yue
    • Journal of applied mathematics & informatics
    • /
    • 제29권1_2호
    • /
    • pp.119-133
    • /
    • 2011
  • This paper proposes an infeasible interior-point algorithm with full-Newton step for linear programming. We introduce a special self-regular proximity to induce the feasibility step and also to measure proximity to the central path. The result of polynomial complexity coincides with the best-known iteration bound for infeasible interior-point methods, namely, O(n log n/${\varepsilon}$).

An Efficient Collision Queries in Parallel Close Proximity Situations

  • Kim, Dae-Hyun;Choi, Han-Soo;Kim, Yeong-Dong
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.2402-2406
    • /
    • 2005
  • A collision query determines the intersection between given objects, and is used in computer-aided design and manufacturing, animation and simulation systems, and physically-based modeling. Bounding volume hierarchies are one of the simplest and most widely used data structures for performing collision detection on complex models. In this paper, we present hierarchy of oriented rounded bounding volume for fast proximity queries. Designing hierarchies of new bounding volumes, we use to combine multiple bounding volume types in a single hierarchy. The new bounding volume corresponds to geometric shape composed of a core primitive shape grown outward by some offset such as the Minkowski sum of rectangular box and a sphere shape. In the experiment of parallel close proximity, a number of benchmarks to measure the performance of the new bounding box and compare to that of other bounding volumes.

  • PDF

삶의 질과 의복의 자아근접도 (Quality of Life and Proximity of Clothing to Self Scale)

  • 전경숙;박혜정
    • 한국의류학회지
    • /
    • 제32권7호
    • /
    • pp.1065-1074
    • /
    • 2008
  • The purpose of this paper was to present the proximity of clothing to self(PCS) which is a subjective measure developed by Sontag and Lee(2004). PCS is the scale to examine the relationship between self and clothing. Since PCS scale was prepared for American consumers, it is necessary to verify the validity as a measure to Korean consumers. Consumers' quality of life are functionally related to satisfaction with all of life's domain and subdomains. Clothing in life facilitates the creativity and expressiveness to the wearer, especially to adolescent. The concept of bottom-up spillover effect developed by Lee et al.(2002) was adopted as research model. Data were gathered by surveying university students using convenient sampling, 419 questionnaires were used in the statistical analysis. It was proved that PCS scale was effective measure to Korean consumers. And also PCS scale could be a proxy indicator in view of the fact that clothing was deeply related to consumers' quality of life.

종방향 전기장 근접 감지 방식 수액 주입 측정 센서 (Intravenous Infusion Monitoring Sensor Based on Longitudinal Electric Field Proximity Sensing Technique)

  • 김영철;세이크 파이잘 아마드;김현덕
    • 센서학회지
    • /
    • 제26권2호
    • /
    • pp.101-106
    • /
    • 2017
  • A novel intravenous (IV) infusion monitoring sensor is presented to measure the drop rate in the drip chamber of an IV infusion set. It is based on a capacitive proximity sensor and detects the variation of the longitudinal electric field induced by the drop falling into the drip chamber. Unlike the conventional capacitor sensor with two semi-cylindrical conductor plates, the proximity sensor for IV monitoring is composed of a pair of conductor rings which are mounted on the outer surface of the drip chamber with a specific gap between them. The characteristics of the proximity sensor for IV monitoring were investigated through three dimensional electrostatic simulations. It showed quite superior performances in comparison with the conventional capacitor sensor. Especially, the proposed proximity sensor exhibits consistent sensitivity regardless of its mounting position on the drip chamber, operates normally though the drip chamber is tilted and shows robustness to the changes of the drop size and the drip factor of the IV infusion set. Thus, the proximity sensor for IV monitoring is more suitable for use in actual environment of IV therapy compared with the conventional capacitor sensor.

Finding Top-k Answers in Node Proximity Search Using Distribution State Transition Graph

  • Park, Jaehui;Lee, Sang-Goo
    • ETRI Journal
    • /
    • 제38권4호
    • /
    • pp.714-723
    • /
    • 2016
  • Considerable attention has been given to processing graph data in recent years. An efficient method for computing the node proximity is one of the most challenging problems for many applications such as recommendation systems and social networks. Regarding large-scale, mutable datasets and user queries, top-k query processing has gained significant interest. This paper presents a novel method to find top-k answers in a node proximity search based on the well-known measure, Personalized PageRank (PPR). First, we introduce a distribution state transition graph (DSTG) to depict iterative steps for solving the PPR equation. Second, we propose a weight distribution model of a DSTG to capture the states of intermediate PPR scores and their distribution. Using a DSTG, we can selectively follow and compare multiple random paths with different lengths to find the most promising nodes. Moreover, we prove that the results of our method are equivalent to the PPR results. Comparative performance studies using two real datasets clearly show that our method is practical and accurate.

Modeling of Bank Asset Management System based on Intelligent Agent

  • Kim, Dae-Su;Kim, Chang-Suk
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • 제1권1호
    • /
    • pp.81-86
    • /
    • 2001
  • In this paper, we investigated the modeling of Bank Asset Management System(BAME) based on intelligent agent. To achieve this goal, we introduced several kinds of agents that show intelligent features. BAMS is a user friendly system and adopts fuzzy converting system and fuzzy matching system that returns reasonable similarity matching results. Generation function of the proximity degree is suggested. Fuzzification of investment type categories and feature values are defined, and generation of proximity degree is also derived. An example of bank asset management system is introduced and simulated. Investment type matching utilizing fuzzy measure is tested and it showed quite reasonable similarity matching results.

  • PDF

선박조종시뮬레이션의 근접도 평가에서 연속 분석과 목표선 분석에 관한 비교 연구 (Comparison of Goal-line and In-length Analyses in the Proximity Measures of Simulated Maneuvers)

  • 이동섭;정태권
    • 한국항해항만학회지
    • /
    • 제31권1호
    • /
    • pp.1-6
    • /
    • 2007
  • 우리나라의 경우 선박조종시뮬레이션을 이용한 선박 통항의 안전성 평가는 흔히 목표선 분석으로 이뤄지고 있다. 이 논문에서는 목표선 분석만으로 이뤄지는 통항 안전성 평가의 위험성을 경고할 목적으로 하나의 예로서 한국해양수산연수원의 선박조종시뮬레이터를 이용하여 15,000 TEU급 컨테이너 선박이 풍속 26노트 풍향 NW의 바람과 낙조류 2.2노트의 조류에서 광양항 항로를 따라 출항하는 시뮬레이션을 실시하고 그 결과에 대하여 목표선 분석과 연속분석을 실시하였다. 이들을 비교 분석한 결과 광양항 항로 중 굴곡부의 한곳에서는 목표선 분석에 의한 침범확률이 연속 분석에 의한 침범 확률보다 다소 크게 나타나고 있는데 이는 목표선 분석만으로도 통항 안전성 평가하는 것은 위험이 따를 수 있음을 제시하는 사례로 판단된다. 그 외에 이 논문에서는 현행의 연구의 항로중심에서 선박의 중심이 벗어난 값을 이용하지 않고 선측의 끝에서 항로경계까지를 최근접거리로 하는 근접도 평가를 제시하였다.

복부 움직임에 따른 초음파 근접센서를 이용한 호흡측정에 관한 연구 (Abdominal Wall Motion-Based Respiration Rate Measurement using An Ultrasonic Proximity Sensor)

  • 민세동;김진권;신항식;윤용현;이충근;이정환;이명호
    • 전기학회논문지
    • /
    • 제58권10호
    • /
    • pp.2071-2078
    • /
    • 2009
  • In this paper, we proposed a non-contact respiration measurement system with ultrasonic proximity sensor. Ultrasonic proximity sensor approach of respiration measurement which respiration signatures and rates can be derived in real-time for long-term monitoring is presented. 240 kHz ultrasonic sensor has been applied for the proposed measurement system. The time of flight of sound wave between the transmitted signal and received signal have been used for a respiration measurement from abdominal area. Respiration rates measured with the ultrasonic proximity sensor were compared with those measured with standard techniques on 5 human subjects. Accurate measurement of respiration rate is shown from the 50 cm measurement distance. The data from the method comparison study is used to confirm the performance of the proposed measurement system. The current version of respiratory rate detection system using ultrasonic can successfully measure respiration rate. The proposed measurement method could be used for monitoring unconscious persons from a relatively close range, avoiding the need to apply electrodes or other sensors in the correct position and to wire the subject to the monitor. Monitoring respiration using ultrasonic sensor offers a promising possibility of non-contact measurement of respiration rates. Especially, this technology offers a potentially inexpensive implementation that could extend applications to consumer home-healthcare and mobile-healthcare products. Further advances in the sensor design, system design and signal processing can increase the range of the measurement and quality of the rate-finding for broadening the potential application areas of this technology.