• Title/Summary/Keyword: Proximal surface

검색결과 183건 처리시간 0.025초

Investigating the Impact of Different Resisted Lateral Band Walking Strategies on Hip Abductor Muscle Activity

  • Sin Sil Kim;Sungbae Jo;Seung-gu Lee;Changho Song
    • Physical Therapy Rehabilitation Science
    • /
    • 제12권1호
    • /
    • pp.1-11
    • /
    • 2023
  • Objective: This study aimed to investigate the effects of squat posture, band position, and contraction type on the muscle activity of the hip abductors during resisted lateral band walking. Design: A cross-sectional survey study Methods: 24 healthy male subjects were recruited, and surface electromyography was used to measure the muscle activity of the gluteus maximus, gluteus medius, and tensor fascia lata of the dominant leg during lateral walking exercises. Resistance bands were applied to the knees, ankles, and feet in semi-squat and squat postures, and exercises were randomly performed under six different conditions. Results: The results showed significant differences in muscle activity in the gluteus maximus, gluteus medius, and tensor fascia lata according to posture, band position, and contraction type (p<0.05). The muscle activity of the hip abductors increased in the squat posture and with the band placed on the distal joint compared to the proximal joint (p<0.05). Additionally, muscle activity was higher in the eccentric contraction phase than in the concentric contraction phase (p<0.05). Contrary to previous studies, moving the resistance band from the ankle to the foot increased the muscle activity of the tensor fascia lata while the activity of the gluteus maximus and gluteus medius also increased. Conclusions: According to the results, squat posture with a resistance band placed on the feet and using an eccentric contraction phase were found to be the most effective methods for strengthening the hip abductors.

강화재의 사용 방법이 복합 레진 인레이 브릿지의 파괴 강도에 미치는 영향 (The effect of reinforcing methods on fracture strength of composite inlay bridge)

  • 변창원;박상혁;박상진;최경규
    • Restorative Dentistry and Endodontics
    • /
    • 제32권2호
    • /
    • pp.111-120
    • /
    • 2007
  • 본 연구는 복합레진 인레이 브릿지에서 강화재의 표면 처리와 사용 방법이 파괴 강도에 미치는 영향을 평가하였다. 본 연구에서 사용한 강화재료는 I Beam, U Beam, 1 + U Beam이었으며, 표면처리 방법은 Silane, Sandblast, Hole형성 (U beam)이었다. 강화 재료의 구성과 표면 처리 방법에 따라 총 11개의 실험군을 설정하였다. 상악 인공치 모형에서 제2소구치의 발거 상태를 가정하고 복합레진 인레이 브릿지 제작을 위하여 인접한 제1소구치에 DO, 제1대구치에 MO 와동을 형성하였다. 와동이 형성된 인공치 모형을 고무 인상체를 이용하여 석고로 제작하고, 각 실험군 별로 강화재료와 강화 재료의 표면 처리 방법에 따라 Tescera ATL (BISCO Inc. IL, USA) 복합레진을 사용하여 복합레진 인레이 브릿지를 제작하였다 그 후 시편을 복제모형에 인산아연시멘트로 합착하고 Universal testing machine (EZ Test, Shimadzu, Japan)을 이용하여 flexural stress를 가하여 파괴 강도를 측정하였으며 95% 유의 수준에서 one-way ANOVA/ Scheffes post-hoc test를 시행하여 통계 분석하였다. 다음과 같은 결론을 얻을 수 있었다. 1. 내부 강화재 I beam을 사용한 실험군이 유의성 있게 높은 파괴 강도 값을 보였다 (P<0.05). 2. 표면 처리 방법에 따른 차이는 나타나지 않았다 (P>0.05). 3. 복합레진 인레이 브릿지의 파괴는 강화 재료를 사용 시에는 복합레진과 강화 재료간에 분리 파괴가 나타났으며 사용하지 않은 경우에는 수직파괴 경향이 나타났다. 4. U beam에 유지 hole을 형성한 경우 파괴 강도 증가를 시키지 않았다.

Machined 티타늄 임플란트와 calcium phosphate coated 티타늄 임플란트의 조직형태계측학적 연구 (Histomorphometric study of machined titanium implants and calcium phosphate coated titanium implants)

  • 강현주;양재호
    • 대한치과보철학회지
    • /
    • 제48권2호
    • /
    • pp.122-127
    • /
    • 2010
  • 연구목적: 본 연구는 machined 임플란트와 골유도능이 있는 calcium phosphate를 electron-beam deposition으로 coating처리한 임플란트의 골/임플란트 접촉률을 조직형태계측학적으로 비교하는 것이다. 연구 재료 및 방법:여섯 마리의 수컷 New Zealand white rabbit과직경3.3 mm, 길이 5 mm의 임플란트 24개를 준비하였다. Machined 임플란트 (대조군)와 calcium phosphate coated 임플란트(실험군)를 좌, 우 경골에 2개씩 총 4개를 식립하고 임플란트 주위에 부하가 가해지지 않도록 하여 3주, 6주의 치유기간을 두었다. 식립 3주와 6주후, 각각 3마리의 토끼를 희생하여 조직시편을 제작하였다. 제작된 시편을 광학현미경 하에서 골/임플란트 접촉률 (BIC ratio)을 계산하고 paired t-test로 두 군을 비교하였다. 결과:골/임플란트 접촉률은 임플란트 식립 3주후, 대조군에서 평균과 표준편차는$44.1{\pm}16.5%$ 이었고 실험군은 $70.8{\pm}18.9%$로 실험군이 통계적으로 유의하게 높았다 (P= 0.0264). 6주후의경우, machined 임플란트는 $78.6{\pm}15.1%$, calcium phosphate coated 임플란트는 $79.0{\pm}26.0%$로 두 군 간 통계적으로 유의한 차이는 없었다. 결론: Calcium phosphate coated 임플란트는 machined 티타늄 임플란트에 비해 빠른 초기 골반응을 나타냈다. 그러므로, 임상적으로 calcium phosphate coated 임플란트를 사용했을 때, 수술 후 치유 기간을 단축하여 조기 부하가 가능할 것으로 사료된다.

치간삭제 후의 법랑질 표면조도와 치아우식 감수성에 관한 연구 (A Study on the Enamel Surface Texture and Caries Susceptibility in Interdentally Stripped Teeth)

  • 김경님;윤영주;김광원
    • 대한치과교정학회지
    • /
    • 제31권6호
    • /
    • pp.567-578
    • /
    • 2001
  • 본 연구는 metal stripper, diamond bur, cross-cut carbide bur을 이용한 기계적 삭제방법과 산을 이용한 화학적 삭제방법 등의 서로 다른 방법으로 삭제된 치아에서 삭제방법에 따른 법랑질 표면조도의 차이를 비교하고, 삭제된 법랑질 표면에 국소적 불소도포와 교정용 전색제를 적용시 치아우식 감수성에 미치는 영향을 알아보기 위해 교정적인 목적으로 발치된 100개의 소구치를 대상으로 주사전자현미경과 레이저 형광법을 이용하여 연구한 바 다음과 같은 결과를 얻었다. 1. 치간삭제방법에 관계없이 인접면 삭제 후 법랑질 표면에 형성된 열구는 세심한 연마과정을 통해서도 제거되지 않았다. 2. 기계적인 치간삭제 방법 중에 가장 활택한 법랑질 표면조도를 보이는 군은 crosscut tungsten carbide bur로 초기삭제 후 sof-$lex^{(r)}$ disk로 연마한 군이었다. 3. 기계적 방법이나 기계적과 화학적 방법을 동반하여 치간 삭제한 모든 군의 치아우식 감수성은 대조군보다 높았다. 그러나 치간삭제 방법에 따른 치아우식 감수성의 차이는 보이지 않았다(p<0.001). 4. APF-gel 이나 sealant을 도포한 군은 치간삭제 후 다른 처치를 하지 않은 군에 비해 치아우식 감수성이 낮았다(p<0.001). 5. APF-gel을 도포한 군이 sealant을 도포한 군보다 치아우식 감수성이 낮았다(P<0.05). 결론적으로, 치간삭제 후 활택한 법랑질 표면을 얻고자 하는 노력에도 불구하고 치간삭제를 실시한 치아는 그 삭제 방법에 관계없이 정상치아에 비해 치아우식 감수성이 높았다. 따라서 치간삭제 후 주기적인 불소의 사용이 치아우식을 예방하는 최선의 방법이라고 생각된다.

  • PDF

암석 자기 변수들을 이용한 제4기 고환경 복원-Fort Riley 캔사스 (Magnetic Parameters as Indicators of Late-Quaternary Environments on Fort Riley Kansas)

  • 박경
    • 한국제4기학회지
    • /
    • 제11권1호
    • /
    • pp.57-68
    • /
    • 1997
  • Climatic change of the late-Quaternary period has been record-ed in the loess deposits of the central Great plains and the record of such change is extractable using a number of approaches and parameters. The stratigraphy of loess deposits which have been investigated on Fort Riley exhibits the same sequence of loess units and intercalated buried soils as is found elsewhere in the re-gion but adds detail unique to the reservation Upland late-Qua-ternary composite stratigraphy preserved on the reservation con-sists of the basal Sangamon soil of the Last interglacial(c. 120-110ka), Gilman Canyon Formation(c. >40 -20ka), Peoria loess(c. 20 -10ka) Brady soil(c. 11 -10ka) Bignell loess(c. 9-\ulcornerka). and mod-ern surface soil. Application of magnetic analyses has provided proxy data sets that represent a time series of climatically regulated pedogenesis/weathering and botanical composition. magetic data have yielded an impression of the variation in climate from Sangamon time to the late Holocene through a reconstruction of the history of pedogenesis/weathering. Sangamon soil formation dominated the reservation durin the Last interglacial as indicated by magnetic parameters. During Gil-man Canyon time loess influx was usually sufficiently slow as to permit pedogenesis which appears to have been at a maximum twice during that time. Warm season grasses were important dur-ing soil formation but diminished in importance during the peri-ods of more rapid loess fall which were cooler and perhaps wet-ter. Peoria loess fall a function of the deterioration of climate during the last Glacial Maximum thinly blanketed the reservation with thickest accumulations occurring to the north-west(Bala Cemetery site)proximal to the source region. Long-term surface stability did not apparently occur within Peoria time but short-term stability may be indicaed by the presence of thin weathering zones(incipient soils) in the Peoria loess. Re-gional landscape stability prevailed during the environmental shift at the Pleistocene/Holocene transition resulting in forma-tion of the well expressed Brady soil. One or more weak soils developed in the Bignell loess as it ac-cumulated. A notable feature of the Bignell loess is the appear-ance of the Altithermal dry period: the loess experienced little weathering and was dominated by warm season grasses until the latter of the Holocene.

  • PDF

서남극 남 쉐틀랜드 군도 마리안 소만에서 바람 및 강수에 의한 여름철 수층 구조의 변화와 부유물질 분산 (Wind-and Rain-induced Variations of Water Column Structures and Dispersal Pattern of Suspended Particulate Matter (SPM) in Marian Cove, the South Shetland Islands, West Antarctica during the Austral Summer 2000)

  • 유규철;윤호일;오재경;강천윤;김예동;배성호
    • 한국해양학회지:바다
    • /
    • 제8권4호
    • /
    • pp.357-368
    • /
    • 2003
  • 남극 세종기지 앞에 위치한 마리안 소만의 여름 수층 구조과 부유물질 분산기작을 이해하기 위해 빙벽 앞에서 CTDT 연속측정을 하였으며, 측정기간 동안의 조석, 부유물질농도, 유속, 그리고 기상요인도 함께 분석되었다. 45 시간동안 1시간 간격으로 측정된 연속 수층 특성 분포에 의하면, 수심 0∼20 m에는 저온$.$저염$.$고탁도의 혼합 표층수가 존재하였고, 수심 20∼40 m에 고온$.$고염$.$저탁도의 최대수온층인 맥스웰 만 유입수가 나타난다. 그 아래의 수심 40∼70 m에는 주변 해수에 비해 저온$.$고탁도의 아빙하성 유출수인 중층 플름(빙하기저부)이 위치한다. 마지막으로 수심 70 m 이하에 나타나는 저층수는 저온$.$고염$.$저탁도의 특성을 보였다. 늦여름 (2 월초)에 연안의 높아진 설선에서 녹아 소만으로 유입하는 담수의 특성은 유입지역의 특성(지형, 빙하조건, 퇴적물의 구성 등)에 따라 수온과 부유물질농도에서 차이를 보였으며, 바람이 거의 불지 않는 측정시기 동안에는 저염$.$고탁도의 표층 플름이 유입지역에 제한적으로 나타났다. 지속적으로 강한 바람이 불 경우, 빙벽 앞에서 육성기원의 혼탁한 담수성 플름, 저온의 중빙하성 용승수/조수빙하 융빙수 그리고 맥스웰 만 유입수가 혼합되면서 표층에 혼합층(저온$.$저염$.$고탁도)이 발달하였다. 소만의 강수는 단기간 빙하성 유출 증가의 가장 큰 요인이며, 중빙하성 용승수의 발생은 조수빙하의 상태와 강수량이 크게 좌우하였다. 특히 많은 양의 강수로 인해 아빙하성 중층 플름의 유출량이 커지면서 중층 이하의 수심에 저염화를 초래하였다. 그러나 입자가 거의 없을 정도로 깨끗한 중앙 빙벽에서 나오는 중빙하성 용승수와 중층 플름의 유입량이 클지라도, 낮은 부유물질농도로 인해 육성기원 입자의 소만 퇴적율은 작을 것이다.

유전치 기성 크라운의 형태 및 치질 삭제량 비교 (Comparison of Crown Shape and Amount of Tooth Reduction for Primary Anterior Prefabricated Crowns)

  • 김소영;임유진;이상호;이난영;지명관
    • 대한소아치과학회지
    • /
    • 제46권1호
    • /
    • pp.64-75
    • /
    • 2019
  • 이 연구의 목적은 임상에서 많이 사용되고 있는 3종의 기성 크라운 즉, 레진관, 레진피복 금속관, 지르코니아 크라운의 크기와 형태를 3차원적으로 계측하여 자연치와 비교함으로써 기성 크라운의 크기 선택과 치질 삭제량에 대한 지침을 얻고자 하는데 있다. 300개의 유전치 석고모델과 3종의 기성 크라운을 대상으로 3D 스캐너와 컴퓨터 이미지 프로그램으로 3차원적 모델을 만들었다. 3차원 모델에서 치관의 근원심 너비, 치관 높이, 치관 ratio, 순면의 곡률반경 등 4가지 평가 척도에 의해 각 기성 크라운별로 한국인 자연치 표준모형과 가장 유사한 형태를 고르고 이를 기준으로 치질 삭제량을 비교, 평가하였다. 유중절치의 경우 기성 크라운별로 레진피복 금속관은 2번, 지르코니아 크라운은 1번, 레진관은 2번이, 유측절치의 경우 레진피복 금속관은 3번, 지르코니아 크라운은 2번, 레진관은 3번이 가장 유사한 형태를 보였다. 치아 삭제량은 상악 유중절치와 유측절치에서 같은 양상을 보였다. 절단연에서는 지르코니아 크라운의 삭제량이 가장 컸다. 인접면은 지르코니아 크라운과 레진관이 비슷한 삭제량을 보였으며 레진피복 금속관에 비해서 컸다. 순면 역시 지르코니아 크라운이 유중절치와 유측절치에서 삭제량이 가장 컸다. 설면의 경우 순면에 비해 전체적으로 삭제량이 적었으며 3종류의 기성 크라운 간에 삭제량 차이도 크지 않았다. 크라운의 형태를 비교하기 위한 4가지 평가 척도 중 치관의 근원심 너비가 기성 크라운의 크기를 선택하는데 가장 중요한 척도로 나타났다.

회전삽입로 국소의치를 이용한 심미적 상악 전치부 수복 증례 (An Esthetic Restoration of the Missing Maxillary Anterior Teeth with the Rotational Path RPD: A Case Report)

  • 이지혜;임소민;정혜은;박찬진;조리라;김대곤
    • 구강회복응용과학지
    • /
    • 제27권2호
    • /
    • pp.209-222
    • /
    • 2011
  • 상실된 상악 전치부는 고정성 보철물이나 가철성 보철물 또는 임플란트 보철 등 다양한 방법을 통하여 수복할 수 있다. 이 중 적절하게 제작된 회전삽입로 국소의치는 경제적, 해부학적 한계를 가진 환자에서 기능적, 심미적으로 우수한 결과를 보일 수 있다. 회전삽입로 국소의치는 일반적 국소의치의 일직선 삽입로와는 달리 국소의치의 한 쪽 유지장치부가 먼저 장착된 뒤 회전하면서 반대쪽의 유지부가 삽입되어 의치가 안착된다. 이 때 언더컷 속에 위치하는 견고한 부연결장치에서 유지력을 획득하고 회전삽입로와 평행하게 긴 수로형 혹은 구미형(dovetail) 레스트 시트에서 지지 및 파지를 얻으므로 일반적인 가요성 유지암 및 파지암을 생략할 수 있어 심미적으로 우수하고 위생 관리에도 유리하다. 그러나 회전삽입로 국소의치에서 한번 제작된 견고한 유지부는 정교한 조절이 불가능해 상대적으로 기공작업이 어렵고 정밀한 보철물 디자인이 필요하므로 임상적인 성공을 위해서는 회전삽입로 국소의치의 원리에 대한 깊은 이해가 필요하다. 이번 증례보고는 회전삽입로 국소의치를 장착한 후 장기적인 유지관리의 어려움을 겪은 증례를 소개하고 이를 예방할 수 있는 이론적, 기공적 주의사항을 보고하고자 한다.

폐색전증 진단에서 나선식 전산화 단층촬영 혈관조영술의 임상적 유용성 (The Clinical Usefulness of Spiral CT Angiography in the Diagnosis of Pulmonary Thromboembolism)

  • 김우규;임병성;김미영;황홍곤
    • Tuberculosis and Respiratory Diseases
    • /
    • 제47권5호
    • /
    • pp.669-680
    • /
    • 1999
  • 연구배경: 폐색전증은 조기진단으로 신속한 치료를 요하는 치명적인 질환으로 관심여부에 따라서는 비슷한 조건의 병원규모라 하더라도 진단율이 상이한 차이를 나타내는 것으로 알려져있다. 폐색전증 진단에서 나선식 전산화 단층촬영 혈관조영술은 높은 민감도와 특이도를 나타낸다고 알려져있다. 저자들은 폐색전증에서 나선식 전산화 단층촬영 혈관조영술의 2, 3차원 영상소견과 진단적 가치를 평가하였고, 나선식 전산화 단층촬영 혈관조영술과 폐관류 스캔을 비교하였다. 방 법: 1997년 9월에서부터 1998년 8월까지 20명의 환자에서 나선식 전산화 단층촬영 혈관조영술을 시행하였고, 이 중 14명의 환자에서 폐관류 스캔을 동시에 시행하여 그 임상적 기록과 함께 분석하였다. 또한 색전의 위치에 따른 혈관 분포 및 동반된 폐실질의 변화를 분석하였다. 결 과: 폐색전증의 색전의 위치에 따른 분포양상을 보면, 좌측 혜(n=103) 보다 우측 폐(n=129)에, 좌 우측폐의 상엽과 중엽을 합친 것(n=101)보다 하엽(n=116)에 많은 빈도를 보였고, 세분절이하로 갈수록 많은 빈도를 보이는데 하엽에서는 5 번째에서 감소되는데, 이것은 세분절이하 혈관 색전에서 나선식 전산화 단층촬영 혈관조영술의 낮은 발견율 및 동반된 폐경색과 무기폐 등이 주로 하엽에 생기기 때문에 가려진 것으로 생각된다. 나선식 전산화 단층촬영 혈관조영술로 폐색전증 진단시, 1명에서 위음성을 보여 95%(19명/20명)의 발견율을 보였고, 급성 및 만성 소견이 각각 16명, 3명이었고, 폐경색, 무기폐, 흉막삼출이 각각 9명(45%), 4명(20%), 6명(30%)이었다. 결 론: 2, 3차원 영상이 포함된 나선식 전산화 단층촬영 혈관조영술은 폐색전증에서 비침습적인 진단 방법으로 1) 폐실질을 포함하여 색전의 전체적 분포를 용이하게 알 수 있으며, 2) 진단시 높은 발견율을 보이며, 3) 비교적 급성과 만성의 구분이 되고, 4) 동반된 폐실질의 변화와 흉막삼출을 보는데 유용한 진단방법이며, 5) 폐관류 스캔 소견과 높은 연관성을 보였다. 제한점으로는 세분절이하에서 인지 장애(perception error)가 있다. 또한, 만성 폐쇄성 폐질환, 천식, 결핵 등이 동반된 호흡기 질환에서는 색전이 나선식 전산화 단층촬영 혈관조영술에서 간과(missing) 될 수 있다.

  • PDF

고정원 강화를 위해 치면에 부착한 fiber-reinforced composite과 스테인리스강 와이어의 피로한도 비교 (Comparison of the fatigue limit of fiber-reinforced composites and stainless steel wires when attached to the tooth surface for anchorage reinforcement)

  • 김문정;박수병
    • 대한치과교정학회지
    • /
    • 제35권4호
    • /
    • pp.302-311
    • /
    • 2005
  • 본 연구는 고정원을 강화하는데 사용되는 fiber-reinforced composite (FRC)과 스테인리스강 와이어의 피로 한도를 치아의 생리적 동요도가 허용되는 조건에서 비교하여 FRC의 임상적 유용성을 알아보기 위해 시행되었다. 스테인리스강 와이어군은 각형과 원형 와이어군으로 나누고 FRC군은 uni-directional군과 woven군, 그리고 각각의 군에 있어서 치간 부위에 레진을 코팅한 군과 코팅하지 않은 군으로 나누었다 각 군간의 피로한도를 일반적인 교정치료기간을 재현한 $5{\times}10^5cycle$의 피로한도 내에서 측정하여 비교하였다. 그 결과 스테인리스강 와이어에서는 각형 와이어가 원형 와이어보다 피로한도가 더 높았지만 통계적으로 유의하지는 않았다 (p>0.05) 치간부위를 레진으로 코팅한 FRC와 코팅하지 않은 FRC 모두 uni-directional군이 woven군보다 피로한도가 더 높게 나타났으며 (p<0.05) 그 값은 치간 부위를 레진으로 코팅한 FRC가 코팅하지 않은 FRC보다 더 높게 나타났다(p<0.05). 스테인리스강 와이어와 FRC 모두 임상적으로 유용한 $5{\times}10^5cycle$의 피로한도 내에서는 파절되지 않았기 때문에 둘 다 고정원 강화를 위해 사용하여도 충분하며 또한 심미성이 요구되거나 부가적인 장치의 부착이 필요한 곳에서는 FRC를 사용하여도 충분하리라 생각된다.