• Title/Summary/Keyword: Proximal humerus fracture

Search Result 74, Processing Time 0.021 seconds

Operative Treatment of Displaced Proximal Humerus Fractures with the Angular Stable Locking Compression Plate (각안정 잠김 압박 금속판을 이용한 전위된 근위 상완골 골절에 대한 수술적 치료)

  • Kim, Dong-Wook;Kim, Chong-Kwan;Jung, Sung-Won;Kim, Hyeon-Soo
    • Clinics in Shoulder and Elbow
    • /
    • v.14 no.1
    • /
    • pp.27-34
    • /
    • 2011
  • Purpose: We examined the clinical and radiological outcomes for displaced proximal humerus fractures that were treated with a PHILOS angular stable plate. Materials and Method: Forty four patients who underwent surgery between March 2007 and February 2010 were included in this study. All the cases were followed up for an average of 12 months. All the patients were examined and interviewed using the Visual Analog Scale (VAS) score, the Constant score and standardized X-rays to check the neck-shaft angle (NSA) and the presence of medial support. Results: The average Visual Analog Scale score was 2.8 points and the average Constant score was 70.5 points. The average neck shaft angle was $122.5^{\circ}$ and this was statistically significant between the good result group and the poor result group. There were 36 cases of the presence of medial support and 8 cases of the absence of medial support and the difference was statistically significant. Complications such as fixation failure happened in 12 cases. Conclusion: PHILOS angular stable plate fixation as an operative treatment for displaced proximal humerus fractures is a good and reliable treatment option.

Strut Support with Tricortical Iliac Allografts in Unstable Proximal Humerus Fractures: Surgical Indication and New Definition of Poor Medial Column Support

  • Lee, Seung-Jin;Hyun, Yoon-Suk;Baek, Seung-Ha
    • Clinics in Shoulder and Elbow
    • /
    • v.22 no.1
    • /
    • pp.29-36
    • /
    • 2019
  • Background: The execution of fibular allograft augmentation in unstable proximal humerus fractures (PHFs) was technically demanding. In this study, the authors evaluated the clinical and radiographic outcomes after tricortical iliac allograft (TIA) augmentation in PHFs. Methods: We retrospectively assessed 38 PHF patients treated with locking-plate fixation and TIA augmentation. Insertion of a TIA was indicated when an unstable PHF showed a large cavitary defect and poor medial column support after open reduction, regardless of the presence of medial cortical comminution in preoperative images. Radiographic imaging parameters (humeral head height, HHH; humeral neck-shaft angle, HNSA; head mediolateral offset, HMLO; and status of the union), Constant score, and range of motion were evaluated. Patients were grouped according to whether the medial column support after open reduction was poor or not (groups A and B, respectively); clinical outcomes were compared for all parameters. Results: All fractures healed radiologically (average duration to complete union, 5.8 months). At final evaluation, the average Constant score was 73 points and the mean active forward flexion was $148^{\circ}$. Based on the Paavolainen assessment method, 33 patients had good results and 5 patients showed fair results. The mean loss of reduction was 1.32 mm in HHH and 5.02% in HMLO. None of the parameters evaluated showed a statistically significant difference between the two groups (poor and not poor medial column support). Conclusions: In unstable PHFs, TIA augmentation can provide good clinical and radiological results when there are poor medial column support and a large cavitary defect after open reduction.

Operative treatment for Proximal Humeral Fracture (상완골 근위부 골절의 수술적 요법)

  • Park Jin-Young;Park Hee-Gon
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.2 no.2
    • /
    • pp.168-175
    • /
    • 2003
  • Fracture about proximal humerus may be classified as the articular segment or the anatomical neck, the greater tuberosity, the lesser tuberosity, and the shaft or surgical neck. Now, usually used, Neer's classification is based on the number of segments displaced, over 1cm of displaced or more than 45 degrees of angulation , rather than the number of fracture line . Absolute indication of a operative treatment a open fracture, the fracture with vascular injury or nerve injury , and unreductable fracture-dislocation . Inversely, the case that are severe osteoporosis, and eldly patient who can't be operated by strong internal fixation is better than arthroplasty used by primary prosthetic replacement and early rehabilitation program than open reduction and internal fixation. The operator make a decision for the patient who should be taken the open reduction and internal fixation, because it's different that anatomical morphology, bone density, condition of patient. The operator decide operation procedure. For example, percutaneous pinning, open reduction, plate & screws, wire tension bands combined with some intramedullary device are operation procedure that operator can decide . The poor health condition for other health problem, fracture with unstable vital sign and severe osteoporosis , are the relative contraindication. The stable fracture without dislocation is not the operative indication . The radiologic film of the prokimal humerus before the operation can not predict for fracture evaluation. It's necessary to good radiologic film for evaluation of fracture form. The trauma serise is better than the other radiologic film for evaluation. The accessary radiologic exam is able to help for evaluation of bone fragment and anatomy. The CT can be helpful in evaluating these injury, especially if the extract fracture type cannot be determined from plain roenterogram of the proximal humerus, bone of humerus head. If the dislocation is severe anatomically , we could consider to do three dimentional remodelling. The MRI doing for observing of bony morphology before the operation is not better than CT If we were suspicious of vascular injury, we could consider the angiography.

  • PDF

Fracture of the Proximal Humerus (상완골 근위부 골절)

  • Park, Gyeong-Jin
    • The Academic Congress of Korean Shoulder and Elbow Society
    • /
    • 2008.11a
    • /
    • pp.212-214
    • /
    • 2008
  • 전위가 경미한 경우 대부분 보존적인 치료로 가능하고 좋은 결과를 얻을 수 있다는 것을 잊지 말자. 또한 전위나 각 형성 정도에 따른 수술의 결정도 환자의 나이와 활동 정도에 따라서 결정되어야 하겠다. 많은 경우에서 골다공증이 심하여 수술을 선택할 때 사전에 준비를 철저히 시행하고 세심한 주의를 기울일 필요가 있다. 아무리 복잡하고 고도의 술기를 요하는 골절이라도, 수술 전에 골절의 형태와 양상을 잘 이해하고 철저한 계획을 세운다면 기대보다 훌륭한 결과를 얻을 수 있다.

  • PDF

A surge in neglected shoulder dislocations and delayed surgical management due to the coronavirus disease 2019 lockdown in India

  • Sahu, Dipit;Gupta, Arun;Bansal, Samarjit S.
    • Clinics in Shoulder and Elbow
    • /
    • v.24 no.4
    • /
    • pp.265-271
    • /
    • 2021
  • Four patients with shoulder problems that were traumatic in etiology presented to us with delays in seeking care ranging from 6 to 12 weeks due to the coronavirus disease 2019 (COVID-19) lockdown. The care of three cases (a 3-month-old neglected anterior shoulder dislocation with a greater tuberosity fracture in a 30-year old man, a 3-month-old neglected anterior shoulder dislocation in a 17-year old boy, and a 2-month-old neglected greater tuberosity fracture in a 31-year old man) was delayed due to the lockdown and the ensuing travel restrictions, while that of one case (a 6-week-old fracture-dislocation of the proximal humerus in a 55-year-old woman) was delayed because the patient was undergoing treatment for COVID-19 at the time of injury. This report intends to present the exceptional circumstances around these cases. The unique treatment challenges and their outcomes are also described to advise the surgeons of the nuances and difficulties in treating these injuries.

The Incidence of Venous Thromboembolism Following Shoulder Surgery: A Pilot Study

  • Cho, Chul-Hyun;Jang, Hyung-Gyu;Park, Ui-Jun;Kim, Hyoung Tae
    • Clinics in Shoulder and Elbow
    • /
    • v.20 no.1
    • /
    • pp.18-23
    • /
    • 2017
  • Background: To assess the incidence of venous thromboembolism (VTE) following shoulder surgery and to evaluate the role of postoperative duplex ultrasonography. Methods: The study comprised a total of 224 patients who underwent shoulder surgery, including 180 shoulder arthroscopic surgeries, 28 shoulder arthroplasties, and 16 plate fixations for proximal humerus fracture between January 2014 and December 2014. The mean age of patients was 59.0 years, and there were 81 men and 143 women. Clinical data, including body mass index, blood tests, metabolic work-up for liver and renal function, previous, and present medical history, were evaluated. Duplex ultrasonography in the operative arm was performed on 2 to 4 days after surgery. Results: The overall incidence of VTE following shoulder surgery was 0.45% (1/224). One patient with open reduction and plate fixation for proximal humerus fracture had asymptomatic deep vein thrombosis that showed complete remission after anticoagulant medication during a 2-month period. Four patients had asymptomatic superficial cephalic vein thrombosis and complete remission without any treatment. There was no case of pulmonary embolism. Conclusions: The incidence of VTE following shoulder surgery was extremely low in Asians. Duplex ultrasonography may be not considered a routine follow-up of shoulder surgery and can be selectively performed in high-risk or symptomatic patients for VTE.

Comparative analysis of proximal humerus fracture management in elderly patients: complications of open reduction and internal fixation by shoulder surgeons and non-shoulder surgeons-a retrospective study

  • Rui Claro;Bianca Barros;Carlos Ferreira;Ana Ribau;Luis Henrique Barros
    • Clinics in Shoulder and Elbow
    • /
    • v.27 no.1
    • /
    • pp.32-38
    • /
    • 2024
  • Background: Open reduction and internal fixation (ORIF) with a locking plate is a popular surgical treatment for proximal humeral fractures (PHF). This study aimed to assess the occurrence of complications in elderly patients with PHF treated surgically using ORIF with a locking plate and to investigate the potential differences between patients treated by shoulder surgeons and non-shoulder surgeons. Methods: A retrospective study was conducted using a single-center database to identify patients aged ≥70 years who underwent ORIF for PHF between January 1, 2011, and December 31, 2021. Data on the Neer classification, follow-up, occurrence of avascular necrosis of the humeral head, implant failure, and revision surgery were also collected. Statistical analyses were performed to calculate the overall frequency of complications according to the Neer classification. Results: The rates of implant failure, avascular osteonecrosis, and revision surgery were 15.7%, 4.8%, and 15.7%, respectively. Complications were more common in patients with Neer three- and four-part fractures. Although the difference between surgeries performed by shoulder surgeons and non-shoulder surgeons did not reach statistical significance, the rate of complications and the need for revision surgery were nearly two-fold higher in the latter group. Conclusions: PHF are highly prevalent in the elderly population. However, the ORIF surgical approach, as demonstrated in this study, is associated with a considerable rate of complications. Surgeries performed by non-shoulder surgeons had a higher rate of complications and a more frequent need for revision surgery. Future studies comparing surgical treatments and their respective complication rates are crucial to determine the optimal therapeutic options. Level of evidence: III.

Arthroscopic Treatment of Greater Tuberosity fracture - Preliminary Report - (상완골 대결절 골절 손상에 대한 관절경적 치료 -예비 보고-)

  • Ji, Jong-Hoon;Kim, Young-Yul;Park, Sang-Eun;Ra, Ki-Hang;Do, Jeong-Hun;Kim, Weon-Yoo
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.6 no.1
    • /
    • pp.57-65
    • /
    • 2007
  • Purpose: The purpose of this study was to evaluate the clinical result of arthroscopic treatments by using suture anchors or suture anchors combined with cannulated screw in the greater tuberosity fracture of the proximal humerus fracture. Materials and Methods: From March 2004 to March 2006 we have used suture anchor or suture anchors combined with cannulated screw for 6 cases of the greater tuberosity fracture which include displaced fractures, comminuted fractures and minimally displaced fractures with comcomittent lesions such as rotator cuff tears, stiffness and labral lesion. In this retrospective study, we analyzed the clinical outcomes by using the range of motion, University of California at Los Angeles shoulder rating scale (UCLA) and the ASES shoulder index score (ASES) in the average 6 months follow up. Results: At the last follow up, average range of motion was improved to 154.3 degree, 145.8 degree, 32.6 degree and L1 vertebrae in each forward flexion, abduction, external rotation and internal rotation. Clinically the UCLA rating scales improved to 31.5 and the ASES shoulder index score (ASES) improved to 93.6 in the last follow up. Conclusion: Arthroscopic treatments by using suture anchor or suture anchors combined with cannulated screw in the greater tuberosity fracture of the proximal humerus fracture is an alternative treatment of the greater tuberosity fracture of the proximal humerus fracture.

  • PDF

Retrieval of an Intravascular Catheter Tip Fracture in a Dog

  • Na, Yeon-Joo;Ko, Hui-Yeon;Geum, MiGyeong;Jeon, Sukhyon;Kim, Se Eun;Kim, Ha-Jung
    • Journal of Veterinary Clinics
    • /
    • v.37 no.5
    • /
    • pp.270-272
    • /
    • 2020
  • An intravenous foreign body was retrieved from a 10-year-old Maltese. A 24 gauze of fracture intravenous (IV) catheter moved into the circulation to a Maltese (3.4 kg) dog through the upper cephalic vein. Radiography was performed to observe the fracture's moving path, followed by fluid therapy. It was found in the upper cephalic vein, moved about 10 cm up to dorsal and near the proximal humerus. Retrieval surgery was performed successfully without complications. The catheter fracture retrieval sometimes remains a challenge because of unknown complications in veterinary medicine. This case report describes that a fracture IV catheter moved to the systemic vein was removed successfully by a surgery.