• Title/Summary/Keyword: Proton transport

Search Result 146, Processing Time 0.023 seconds

Performance of the PEMFC for the mobile devices according to cathode (Cathode에 따른 휴대용 PEM 연료전지의 성능 변화)

  • Lee, Se-Won;Lee, Kang-In;Park, Min-Soo;Chu, Chong-Nam
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.05a
    • /
    • pp.550-553
    • /
    • 2008
  • In this paper, experiments of air-breathing proton exchange membrane fuel cell (PEMFC) for mobile devices were carried out according to the cathode conditions. These conditions are defined by the cathode flow field plate type (the channel type, the open type) and the cathode surface direction. Single cell and 6-cell stack were used in this experiments. The experimental results showed that the open type cathode flow field plate gave better performance for small size PEMFCs because the open type cathode plate allowed better air convection than the channel type cathode plate. In the experiments related to the direction of the slits on the cathode flow field plate, the horizontal slit cell was better than the vertical slit cell. With respect to the cathode surface direction, when the cathode surface is placed in the direction normal to the ground, PEMFC generated more stable power in the mass transport loss region.

  • PDF

Dissolution of Protons in Oxides

  • Norby, Truls
    • The Korean Journal of Ceramics
    • /
    • v.4 no.2
    • /
    • pp.128-135
    • /
    • 1998
  • The paper gives a brief introduction to protonic defects and their chemistry, thermodynamics and transport in oxides. The temperature dependence of the equilibrium concentration of protons is illustrated and compared for different acceptor-doped oxides. The difficulties of saturating as well as emptying the oxides of protons are discussed. In order to illustrate the possibility of lattice relaxation of defects, a conceptual study is made of a case where the enthalpy of dissolution of protons(water) at the cost of oxygen vacancies is assumed dependent on the concentration of vacancies. It is shown how this changes the behavior of hydration curves vs temperature and water vapour pressure. finally, a discussion is given on the water uptake in heavily oxygen deficient oxides; how water uptake may affect order-disorder in the oxygen sublattice and eventually lead to defective, disordered or ordered oxyhydroxides or hydroxides of potential interest as intermediate temperature proton conductions.

  • PDF

The development of membranes for high temperature PEMFC

  • Lee, Doo-Yeon;Sun, Hee-Young;Cho, Chung-Kun;Lee, Myung-Jin;Seung, Do-Young
    • Proceedings of the Polymer Society of Korea Conference
    • /
    • 2006.10a
    • /
    • pp.184-184
    • /
    • 2006
  • We have succeeded in the preparation of high molecular weight polybenzimidazoles by solution polycondensation of 3,3'-diaminobenzidine tetrahydrochloride with isophthalic acid, terephthalic acid, or with their derivatives using polyphosphoric acid both as solvent and as condensing agent. Also, we modified phosphoric acid into fluoroalkyl-phosphonic acids[F-PA]. The main reasons are as follows, first of all F-PAs are stronger acids than PA and alkylphosphonic acids which should promote proton hopping and transport. In addition, F-PA has weaker adsorption onto Pt which help to prevent electrocatalyst poisoning and promote higher oxygen reduction activity. The ionic conductivity of 85%-H3PO4 doped membranes show $10^{-2}\;Scm^{-1}\;to\;3{\times}10^{-2}\;Scm^{-1}\;at\;150^{\circ}C$ MEA with 2 %-added electrolyte shows slightly higher cell voltage than the others.

  • PDF

Rotaxane/Nafion Composite Membranes for Direct Methanol Fuel Cells (직접 메탄올 연료전지용 Rotaxane/Nafion 전해질막)

  • Cho Hyun Dong;Won Jongok;Kang Yong Soo;Ha Heung Yong
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 2004.11a
    • /
    • pp.146-148
    • /
    • 2004
  • Rotaxane/Nafion composite membranes were prepared and characterized. Proton conductivity was .01 S/cm and the methanol ($10\;wt\%$) premeability was $7.88{\times}10^{-7}\;cm^2/sec$ at 5 $wt\%$ of rotaxane/Nafion composite membranes. The characterization of the status of retaxane inside of Nafion membranes is under study.

  • PDF

A Circuit Model of PEMFC for Design and Analyze Fuel Cell Power System (연료전지 전원 시스템의 설계 및 분석을 위한 PEMFC의 회로 모델)

  • Lee S.H.;Lee H.W.;Kwon S.K.
    • Proceedings of the KIPE Conference
    • /
    • 2006.06a
    • /
    • pp.197-199
    • /
    • 2006
  • The Proton Exchange Membrane Fuel Cells (PEMFCs) are being used in a variety of applications including portable power generation, transportation and back-up power systems. In this paper presents a novel circuit model for a PEMFC that can be used to design and analyze fuel-cell power system. The Pspice-based model uses BJTs, L and C elements available in the Pspice library with some modification. The model includes the phenomena like activation polarization, ohmic polarization and mass transport effect present in a PEM fuel cell. Simulated characteristics of the fuel cell were compared with the experimental results obtained on a commercial fuel cell.

  • PDF

Son transport characteristics through random or block polymer electrolyte membranes (랜덤 및 블록 공중합에 따른 고분자 전해질막의 이온전도특성)

  • Park, Chi-Hoon;Lee, Chang-Hyun;Nam, Sang-Yong;Park, Ho-Bum;Lee, Young-Moo
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 2004.05b
    • /
    • pp.57-60
    • /
    • 2004
  • Polymer electrolyte membranes have been studied widely in chloro-alkali electrolysis, cationic exchange resins, and fuel cell applications. Especially, sulfonated polyimide membranes have been suggested as a potential polymer electrolyte in PEMFC due to their excellent thermal stability and high proton conductivity.(omitted)

  • PDF

KOMAC RFQ Vacuum System

  • Han, J.M.d;S.H.Jeong;Cho, Y.S.;Park, B.H.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.33-33
    • /
    • 1999
  • The design of a vacuum pumping system for the KOMAC (Korea Multipurpose Accelerator Complex) RFQ(Radio-Frequency Quadrupole) linac is described. [Fig] Resulted from the lost proton beam, gas streaming from the LEBT (Low Energy Beam Transport) and out-gassing from the surfaces of the RFQ cavity and vacuum plumbing, the total gas load will be on the order of 7.2$\times$10-4 Torr-liters/sec, consisting mainly of hydrogen. The system designed to pump on a continual basis with redundancy to ensure that the minimal operating vacuum level of 1.0$\times$10-6 Torr is maintained even under abnormal conditions. Details of the design, performance analysis and the preliminary test results of the cryogenic pumps are presented.

  • PDF

On the Chemical Diffusion Coefficient of H2O in AB1-xBxO(3-x/2)-type Perobskites

  • Baek, Hyun-Deok;Virkar, Anil V.
    • Journal of the Korean Ceramic Society
    • /
    • v.40 no.9
    • /
    • pp.827-831
    • /
    • 2003
  • In proton-conducting perovskites, oxygen ions and protons make a diffusion pair for a chemical diffusion and thus lead to the transport of $H_2O$ under its chemical potential gradient. The present manuscript develops relationships between the chemical diffusion coefficient of $H_2O$ and the diffusion coefficients of protons and oxygen vacancies with an emphasis on the thermodynamic behavior of the oxygen vacancies. Depending on the degree of hydration X, two different expressions of the chemical diffusion coefficient were obtained : equation omitted and equation omitted.

Evaluation on the Electro-electrodialysis for hydrogen production by thermochemical water-splitting IS process (열화학적 수소제조 IS 프로세스의 효율향상을 위한 전해-전기투석의 실험적 평가)

  • Hong, Seong-Dae;Kim, Jeong-Geun;Lee, Sang-Ho;Choi, Sang-Il;Bae, Ki-Kwang;Hwang, Gab-Jin
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.06a
    • /
    • pp.13-16
    • /
    • 2006
  • Electro-electrodialysis (EED) experiments were carried out for the HI concentration from HIx $(HI-H_2O-I_2)$ solution to improve the Hl decomposition reaction in the thermochemical water-splitting is (iodine-Sulfur) process. EED cell is composed of the collector electrode and electrolyte. Nafion 117 which was cation exchange membrane used as an electrolyte, and the activated carbon cloth used as an electrode. The HI concentration experiment was carried out using the HIx solution and molar ratio of the $I_2$ were varied from 1 to 3 mole. The cell voltages were decreased as temperature increase. And, membrane properties such as transport number of proton and electro-osmosis coefficient were decreased as temperature increase

  • PDF