Proton Therapy Review: Proton Therapy from a Medical

  • Lee, Se Byeong
    • 한국의학물리학회지:의학물리
    • /
    • 제31권3호
    • /
    • pp.99-110
    • /
    • 2020
  • With hope and concern, the first Korean proton therapy facility was introduced to the National Cancer Center (NCC) in 2007. It added a new chapter to the history of Korean radiation therapy. There have been challenging clinical trials using proton beam therapy, which has seen many impressive results in cancer treatment. Compared to the rapidly increasing number of proton therapy facilities in the world, only one more proton therapy center has been added since 2007 in Korea. The Samsung Medical Center installed a proton therapy facility in 2015. Most radiation oncology practitioners would agree that the physical properties of the proton beam provide a clear advantage in radiation treatment. But the expensive cost of proton therapy facilities is still one of the main reasons that hospitals are reluctant to introduce them in Korea. I herein introduce the history of proton therapy and the cutting edge technology used in proton therapy. In addition, I will cover the role of a medical physicist in proton therapy and the future prospects of proton therapy, based on personal experience in participating in proton therapy programs from the beginning at the NCC.

Feasibility Test of Flat-Type Faraday Cup for Ultrahigh-Dose-Rate Transmission Proton Beam Therapy

  • Sang-il Pak;Sungkoo Cho;Seohyeon An;Seonghoon Jeong;Dongho Shin;Youngkyung Lim;Jong Hwi Jeong;Haksoo Kim;Se Byeong Lee
    • 한국의학물리학회지:의학물리
    • /
    • 제33권4호
    • /
    • pp.108-113
    • /
    • 2022
  • Purpose: Proton therapy has been used for optimal cancer treatment by adapting its Bragg-peak characteristics. Recently, a tissue-sparing effect was introduced in ultrahigh-dose-rate (FLASH) radiation; the high-energy transmission proton beam is considered in proton FLASH therapy. In measuring high-energy/ultrahigh-dose-rate proton beam, Faraday Cup is considered as a dose-rate-independent measurement device, which has been widely studied. In this paper, the feasibility of the simply designed Faraday Cup (Poor Man's Faraday Cup, PMFC) for transmission proton FLASH therapy is investigated. Methods: In general, Faraday cups were used in the measurement of charged particles. The simply designed Faraday Cup and Advanced Markus ion chamber were used for high-energy proton beam measurement in this study. Results: The PMFC shows an acceptable performance, including accuracy in general dosimetric tests. The PMFC has a linear response to the dose and dose rate. The proton fluence was decreased with the increase of depth until the depth was near the proton beam range. Regarding secondary particles backscatter from PMFC, the effect was negligible. Conclusions: In this study, we performed an experiment to investigate the feasibility of PMFC for measuring high-energy proton beams. The PMFC can be used as a beam stopper and secondary monitoring system for transmission proton beam FLASH therapy.

두경부암의 양성자치료: 현재의 임상 적용 및 발전 방향 (Proton Therapy for Head and Neck Cancer: Current Clinical Applications and Future Direction)

  • 오동렬
    • 대한두경부종양학회지
    • /
    • 제37권1호
    • /
    • pp.1-10
    • /
    • 2021
  • Intensity-modulated radiation therapy (IMRT) using X-rays is a standard technique implemented for treating head and neck cancer (HN C). Compared to 3D conformal RT, IMRT can significantly reduce the radiation dose to surrounding normal tissues by using a highly conformal dose to the tumor. Proton therapy is a type of RT that uses positively charged particles named protons. Proton therapy has a unique energy deposit (i.e., Bragg peak) and greater biological effectiveness than that of therapy using X-rays. These inherent properties of proton therapy make the technique advantageous for HNC treatment. Recently, advanced techniques such as intensity-modulated proton therapy have further decreased the dose to normal organs with a higher conformal dose to the tumor. The usage of proton therapy for HNC is becoming widespread as the number of operational proton therapy centers has increased worldwide. This paper aims to present the current clinical evidence of proton therapy utility to HNC clinicians through a literature review. It also discusses the challenges associated with proton therapy and prospective development of the technique.

Dosimetric Impact of Ti Mesh on Proton Beam Therapy

  • Cho, Shinhaeng;Goh, Youngmoon;Kim, Chankyu;Kim, Haksoo;Jeong, Jong Hwi;Lim, Young Kyung;Lee, Se Byeong;Shin, Dongho
    • 한국의학물리학회지:의학물리
    • /
    • 제28권4호
    • /
    • pp.144-148
    • /
    • 2017
  • When a high density metallic implant is placed in the path of the proton beam, spatial heterogeneity can be caused due to artifacts in three dimensional (3D) computed tomography (CT) scans. These artifacts result in range uncertainty in dose calculation in treatment planning system (TPS). And this uncertainty may cause significant underdosing to the target volume or overdosing to normal tissue beyond the target. In clinical cases, metal implants must be placed in the beam path in order to preserve organ at risk (OARs) and increase target coverage for tumors. So we should introduce Ti-mesh. In this paper, we measured the lateral dose profile for proton beam using an EBT3 film to confirm dosimetric impact of Ti-mesh when the Ti-mesh plate was placed in the proton beam pathway. The effect of Ti-mesh on the proton beam was investigated by comparing the lateral dose profile calculated from TPS with the film-measured value under the same conditions.

Measurement of Proton Beam Dose-Averaged Linear Energy Transfer Using a Radiochromic Film

  • Seohyeon An;Sang-il Pak;Seonghoon Jeong;Soonki Min;Tae Jeong Kim;Dongho Shin;Youngkyung Lim;Jong Hwi Jeong;Haksoo Kim;Se Byeong Lee
    • 한국의학물리학회지:의학물리
    • /
    • 제33권4호
    • /
    • pp.80-87
    • /
    • 2022
  • Purpose: Proton therapy has different relative biological effectiveness (RBE) compared with X-ray treatment, which is the standard in radiation therapy, and the fixed RBE value of 1.1 is widely used. However, RBE depends on a charged particle's linear energy transfer (LET); therefore, measuring LET is important. We have developed a LET measurement method using the inefficiency characteristic of an EBT3 film on a proton beam's Bragg peak (BP) region. Methods: A Gafchromic EBT3 film was used to measure the proton beam LET. It measured the dose at a 10-cm pristine BP proton beam in water to determine the quenching factor of the EBT3 film as a reference beam condition. Monte Carlo (MC) calculations of dose-averaged LET (LETd) were used to determine the quenching factor and validation. The dose-averaged LETs at the 12-, 16-, and 20-cm pristine BP proton beam in water were calculated with the quenching factor. Results: Using the passive scattering proton beam nozzle of the National Cancer Center in Korea, the LETd was measured for each beam range. The quenching factor was determined to be 26.15 with 0.3% uncertainty under the reference beam condition. The dose-averaged LETs were measured for each test beam condition. Conclusions: We developed a method for measuring the proton beam LET using an EBT3 film. This study showed that the magnitude of the quenching effect can be estimated using only one beam range, and the quenching factor determined under the reference condition can be applied to any therapeutic proton beam range.

Progress on Proton Therapy Facility Project in National Cancer Center, Korea

  • Kim, Jong-Won;Park, Sung-Yong;Park, Dahl;Kim, Dae-Yong;Shin, Kyung-Hwan;Cho, Kwan-Ho
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.180-182
    • /
    • 2002
  • A Proton Therapy Center was established this year in National Cancer Center, Korea. We chose IBA of Belgium as the vendor of the equipment package. A 230 MeV fixed-energy cyclotron will deliver proton beams into two gantry rooms, one horizontal beam room, and one experimental station. The building for the equipment is currently under design with a special emphasis on radiation shielding. Installation of equipments is expected to begin in September next year starting with the first gantry, and the acceptance test will be performed about a year later. To generate therapeutic radiation fields the wobbling method will be a main treatment mode for the first gantry. A pencil beam scanning system on the other hand will be equipped for the second gantry relying on the availability at the time of installation. The beam scanning with intensity modulation adapted will be a most advanced form in radiation therapy known as IMPT. Some details on the project progress, scope of the system, and design of building are described.

  • PDF

Upgrade of gamma electron vertex imaging system for high-performance range verification in pencil beam scanning proton therapy

  • Kim, Sung Hun;Jeong, Jong Hwi;Ku, Youngmo;Jung, Jaerin;Cho, Sungkoo;Jo, Kwanghyun;Kim, Chan Hyeong
    • Nuclear Engineering and Technology
    • /
    • 제54권3호
    • /
    • pp.1016-1023
    • /
    • 2022
  • In proton therapy, a highly conformal proton dose can be delivered to the tumor by means of the steep distal dose penumbra at the end of the beam range. The proton beam range, however, is highly sensitive to range uncertainty, which makes accurately locating the proton range in the patient difficult. In-vivo range verification is a method to manage range uncertainty, one of the promising techniques being prompt gamma imaging (PGI). In earlier studies, we proposed gamma electron vertex imaging (GEVI), and constructed a proof-of-principle system. The system successfully demonstrated the GEVI imaging principle for therapeutic proton pencil beams without scanning, but showed some limitations under clinical conditions, particularly for pencil beam scanning proton therapy. In the present study, we upgraded the GEVI system in several aspects and tested the performance improvements such as for range-shift verification in the context of line scanning proton treatment. Specifically, the system showed better performance in obtaining accurate prompt gamma (PG) distributions in the clinical environment. Furthermore, high shift-detection sensitivity and accuracy were shown under various range-shift conditions using line scanning proton beams.

양성자치료용 보상체의 영상기반 정도 관리 기반 프로그램 개발 (Image Based Quality Assurance of Range Compensator for Proton Beam Therapy)

  • 김진성;윤명근;김동욱;임영경;곽정원;박소아;신동호;신정욱;이세병;박성용;조관호
    • 한국의학물리학회지:의학물리
    • /
    • 제19권1호
    • /
    • pp.35-41
    • /
    • 2008
  • 양성자치료는 양성자의 물리적 특성으로 인해 인체 내의 특정범위에 모든 에너지를 전달하고 감쇠되어 타겟조직 뒤에 존재하는 정상조직에는 방사선이 조사되지 않는 큰 장점을 가진 치료법이다. 이 방법은 인체 내의 암 조직을 타겟으로 했을 때, 빔 방향에서의 타겟의 2차원적인 모양은 황동으로 제작된 블럭을 통해 정상조직에 들어가는 방사선을 차폐하고 마진을 주어서 GTV (eross Tumor Volume)에 90% 이상의 선량이 전달되도록 조절한다. 그리고, 양성자 빔의 날줄방향 (longitudinal)에서의 타겟의 3차원적인 모양을 고려하여 PMMA로 이루어진 보상체(compensator)를 밀링머신으로 조각하여 타겟에 방사선이 정확하게 분포되도록 한다. 이러한 보상체의 정확한 정도 관리를 위해 현재 사용되는 수동적인 방법을 보완하여 X선 영상으로 해당하는 보상체의 영상을 획득하여 이 영상을 기반으로 정도관리를 할 수 있는 방법을 제안하였고, 제안한 방법으로 보상체의 각각의 깎여진 평면의 모양과 두께를 정성적으로 비교 및 평가할 수 있었으며 두 영상의 차이가 80% 이상 맞는 것으로 확인되었다. 이를 바탕으로 영상을 이용한 정도관리 프로그램을 보완하여 추후 실제 양성자치료 정도관리에 사용될 예정이다.