• Title/Summary/Keyword: Proton shielding

Search Result 30, Processing Time 0.031 seconds

Comparison of Physics Model for 600 MeV Protons and 290 MeV·n-1 Oxygen Ions on Carbon in MCNPX

  • Lee, Arim;Kim, Donghyun;Jung, Nam-Suk;Oh, Joo-Hee;Oranj, Leila Mokhtari;Lee, Hee-Seock
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.2
    • /
    • pp.123-131
    • /
    • 2016
  • Background: With the increase in the number of particle accelerator facilities under either operation or construction, the accurate calculation using Monte Carlo codes become more important in the shielding design and radiation safety evaluation of accelerator facilities. Materials and Methods: The calculations with different physics models were applied in both of cases: using only physics model and using the mix and match method of MCNPX code. The issued conditions were the interactions of 600 MeV proton and $290MeV{\cdot}n^{-1}$ oxygen with a carbon target. Both of cross-section libraries, JENDL High Energy File 2007 (JENDL/HE-2007) and LA150, were tested in this calculation. In the case of oxygen ion interactions, the calculation results using LAQGSM physics model and JENDL/HE-2007 library were compared with D. Satoh's experimental data. Other Monte Carlo calculations using PHITS and FLUKA codes were also carried out for further benchmarking study. Results and Discussion: It was clearly found that the physics models, especially intra-nuclear cascade model, gave a great effect to determine proton-induced secondary neutron spectrum in MCNPX code. The variety of physics models related to heavy ion interactions did not make big difference on the secondary particle productions. Conclusion: The variations of secondary neutron spectra and particle transports depending on various physics models in MCNPX code were studied and the result of this study can be used for the shielding design and radiation safety evaluation.

A Study on Radiation Shielding for Grid-stiffened Multi-Functional Composite Structures (격자-강화된 다기능 복합재 구조체의 방사차폐에 관한 연구)

  • Jang, Tae Seong;Rhee, Juhun;Seo, Hyun-Suk;Hyun, Bum-Seok;Kim, Taig Young;Seo, Jung Ki
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.42 no.8
    • /
    • pp.629-639
    • /
    • 2014
  • This paper deals with an alternative multi-functional structures by using grid-stiffened composite structure with excellent bending stiffness and lightweight characteristics which is capable of easy embedding of electrical/electronic circuitry into structure. The enhancement of thermal conduction capability is made by the application of pitch-based carbon fiber. The lightweight radiation spot shielding technique is also proposed for multi-functional structures without conventional housing and the effectiveness of selective radiation shielding is validated through the proton irradiation test.

Radiation Exposure of an Astronaut subject to Various Space Radiation Environments and Shielding Conditions (다양한 우주방사선 환경과 차폐 조건에서 우주인이 받는 방사선 피폭량)

  • Chae, Myeong-Seon;Chung, Bum-Jin
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.38 no.10
    • /
    • pp.1038-1048
    • /
    • 2010
  • Radiation exposures of an astronaut during the space travels to the International Space Station(ISS) of the Soyuz and the Moon of the Apollo, were calculated considering the altitude, boarding time, period of stay, kinds of spaceships and space suits. The calculated radiation exposures decrease dramatically according to the thickness of the shielding by the wall of the spaceships and by the space suits. For the space travel to the ISS of Soyuz at Low Earth orbit, the thickness of the spaceship required to optimally reduce the radiation exposure is 3 cm. For the Extravehicle Mobility Unit(EMU) the exposures are minimized at 4 cm of the aluminized Mylar and 5 cm of the Demron, respectively. The aluminized Mylar showed better radiation shielding than the Demron which contains the high Z materials. The radiation exposures of an astronaut were $4.2\times10^{-6}$ Sv for the ISS travel and $4.3\times10^{-5}$ Sv for the Moon explore. The high concentration of the high energy proton flux at the surface of the Moon results in high radiation exposure. The calculation scheme and results of this study can be used in the design of the shielding performance of a spaceship and space suits.

400 MeV/nucleon 12C Ions Shielding Benchmark Calculations using MCNPX with Different Nuclear Data Libraries (400 MeV/nucleon 12C 이온의 MCNPX 와 핵자료를 이용한 차폐 벤치마킹 계산)

  • Shin, Yun Sung;Kim, yong min;Kim, dong hyun;Jung, nam suk;Lee, hee seock
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.5
    • /
    • pp.295-300
    • /
    • 2015
  • There are various type of particle accelerators such as Kyoungju 100-MeV proton beam accelerator in Korea. And Korea plans to build large particle accelerator such as heavy ion accelerator and 4th generation light source facility. The accelerated high energy particles of these facility produce 2nd neutron after nuclear reaction with target materials. And then these 2nd neutron activate structural materials and surrounding environment. Accordingly, it is important to consider the activation and shielding calculation on design of facility for safety operation. In this study, we tried to calculate and compare the neutron flux from the interaction $^{la}150$ beam with target material(Cu) according to thickness of iron and concrete shielding material by MCNPX 2.7 with nuclear library JENDL/HE 07and la150. To verify the properties of nuclear library, we compared computational results with experimental value. These results can be used for dose evaluation technology in planning of the shielding of large particle accelerator.

Recent Status of Commercial PET Cyclotron and KOTRON-13 (KOTRON-13과 상용 PET 사이클로트론의 최근 기술 동향)

  • Chai, Jong-Seo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.1
    • /
    • pp.1-8
    • /
    • 2005
  • This paper is described on the development of KOTRON-13 and recent status of PET cyclotron by commercial cyclotron companies. KIRAMS has developed medical cyclotron which is KIRAMS-13. Samyoung Unitech produces KOTRON-13 with transfered technology by KIRAMS. As a part of Regional Cyclotron Installation Protect, KOTRON-13 cyclotrons and $[18F]FDG$ production modules are being installed at regional cyclotron centers in Korea. The medical concern with radiation technology has been growing for the last several years. Early cancer diagnosis through the cyclotron and PET-CT have been brought to public attention by commercial cyclotron models in the world. The new commercial cyclotron models are introduced compact low energy cyclotrons developed by CTI, GE, Sumitomo in recent. It produces different short-lived radioisotopes, such as $[^{18}F],\;[^{11}C],\;[^{13}N]\;and\;[^{15}O]$. For the better reliability acceleration particle is proton only. The characteristics of new model cyclotrons are changed to lower energy corresponding to less 13 MeV. New models have self-shielding and low power consumption. Design criteria for the different types of commercial cyclotrons are described with reference to hospital demands.

ESTIMATION OF SEU THRESHOLD ENERGY FROM KITSAT-1 DATA USING AP-8 MODEL (AP-8 모델을 이용한 우리별 1호 SEU 문턱에너지 추정)

  • 김성준;신영훈;김성수;민경욱
    • Journal of Astronomy and Space Sciences
    • /
    • v.18 no.2
    • /
    • pp.109-118
    • /
    • 2001
  • KITSAT-1, launched in 1992, passes through Inner Van Allen Radiation Belt in which high energy Protons cause single event upsets(SBUs) in the main memory of KITSAT-1 OBC(On-Board Computer) 186. The present paper compares SEU data from the OBC186 with the AP-8 model of NASA/NSSDC using the Chi-Square method to estimate the SEU threshold energy. Shielding effect by the satellite body has been taken into account to model the proton fluxes at the position of OBC186, and SEUs recorded during the high solar activities have been removed to avoid the spurious result. The result shows that the SEU threshold energy of the main memory of KITSAT-1 OBC186 is estimated to be about $110{pm}10MeV$.

  • PDF

JASMIN: Shielding Studies on High Energy Neutron Produced By 120 GeV Protons

  • Lee, Hee-Seock;Sanami, Toshiya;Iwamoto, Yosuke;Kajimoto, Tsuyoshi;Shigyo, Nobuhiro;Saito, Kiwamu;Hagiwara, Masayuki;Yashima, Hiroshi;Kasugai, Yoshimi;Ramberg, Erik;Coleman, Richard;;Meyhoefer, Aria;Mokhov, Nikolai V.;Leveling, Anthony F.;Boehnlein, David J.;Vaziri, Kamran;Sakamoto, Yukio;Nakashima, Hiroshi
    • 대한방사선방어학회:학술대회논문집
    • /
    • 2010.04a
    • /
    • pp.94-95
    • /
    • 2010
  • The accuracy of typical dosimeters used around high energy accelerator were proved by dose rate measurements. The experimental neutron spectrum were useful for improving high energy Monte Carlo codes by validating the implemented models. In series of this joint research the experimental data will be upgrade successively. This research program is opened to experts and students in Korea, too.

  • PDF

Study on the design of GEO Satellite System in Space Radiation Environment (우주방사능 환경에서 정지궤도 위성시스템 설계에 관한 고찰)

  • Hong, Sang-Pyo;Heo, Jong-Wan
    • Journal of the Korea Society for Simulation
    • /
    • v.19 no.4
    • /
    • pp.123-128
    • /
    • 2010
  • The space radiation/total ionizing Dose(TID) and its effects, and the GEO satellite system design considerations in space radiation environment are studied in this paper using Spenvis(Space Environment Information System). The GEO satellite system in space environment is simulated by NASA AP8/AE8, JPL91 and NRL CREME models, repectively for trapped particle, solar proton and cosmic-ray. The total ionizing Dose which is accumulated continuously to spacecraft electronics has been expressed as the function of aluminum thickness. These values can be used as the criteria for the selection of electronic parts and shielding thickness of the Digital Channel Amplifier(DCAMP) structure.

A Study of Phosphate Adsorption on Kaolinite by $^{31}$P NMP Spectroscopy ($^{31}$P NMR을 이용한 카올리나이트에 흡착된 인산염의 연구)

  • 김영규
    • Journal of the Mineralogical Society of Korea
    • /
    • v.13 no.4
    • /
    • pp.186-195
    • /
    • 2000
  • To study phosphate adsorption on kaolinite, $^{31}$ P MAS NMR(magic angle spinning nuclear magnetic resonance spectroscopy)has been used for kaolinite reacted in 0.1 M phosphate solutions at pH’s from 3 to 11. There are at least 3 different forms of phosphate on kaolinite. One is the phosphate physically adsorbed on kaolinite surface (outer-sphere complexes) or species left after vacuum-filtering. The second is the phosphate adsorbed by ligand exchange (inner-sphere complexes), and the third is Al-phosphate precipitates which are pH dependent. Most of the inner-spherer complexes and surface precipitates are mainly on hydroxided Al(aluminol) rather than hydroxided Si(silanol). These are pertinent with the results obtained from the phosphate adsorption experiments on silica gel and ${\gamma}$-Al$_2$O$_3$ as model compounds, respectively. The two peaks with more negative chemical shifts(more shielded) than the ortho-phosphate peak (positive chemical shift) are assigned to be the inner-sphere complexes and surface precipitates. The $^{31}$ P chemical shifts of the Al-phosphate precipitates are more negative than those of inner-sphere complexes at a given pH due to the larger number of P-O-Al linkages per tetrahedron. The chemical shifts of both the inner-sphere complexes and surface precipitates are more negative than those of inner-sphere complexes at a given pH due to the larger number of P-O-Al linkages per tetrahedron. The chemical shifts of both the inner-sphere complexes and surface precipitates become progressively less shielded with increasing pH. For the inner-sphere complexes, decreasing phosphate protonation combined with peak averaging by rapid proton exchange among phosphate tetrahedra with different numbers of protons is though to be the reason for the peak change. The decreasing shielding with increasing pH for surface precipitates is probably due to the decreasing average number of P-O-Al linkages per tetrahedron combined with decreasing protonation like inner-sphere complexes.

  • PDF

Evaluation of Biological Characteristics of Neutron Beam Generated from MC50 Cyclotron (MC50 싸이클로트론에서 생성되는 중성자선의 생물학적 특성의 평가)

  • Eom, Keun-Yong;Park, Hye-Jin;Huh, Soon-Nyung;Ye, Sung-Joon;Lee, Dong-Han;Park, Suk-Won;Wu, Hong-Gyun
    • Radiation Oncology Journal
    • /
    • v.24 no.4
    • /
    • pp.280-284
    • /
    • 2006
  • $\underline{Purpose}$: To evaluate biological characteristics of neutron beam generated by MC50 cyclotron located in the Korea Institute of Radiological and Medical Sciences (KIRAMS). $\underline{Materials\;and\;Methods}$: The neutron beams generated with 15 mm Beryllium target hit by 35 MeV proton beam was used and dosimetry data was measured before in-vitro study. We irradiated 0, 1, 2, 3, 4 and 5 Gy of neutron beam to EMT-6 cell line and surviving fraction (SF) was measured. The SF curve was also examined at the same dose when applying lead shielding to avoid gamma ray component. In the X-ray experiment, SF curve was obtained after irradiation of 0, 2, 5, 10, and 15 Gy. $\underline{Results}$: The neutron beams have 84% of neutron and 16% of gamma component at the depth of 2 cm with the field size of $26{\times}26\;cm^2$, beam current $20\;{\mu}A$, and dose rate of 9.25 cGy/min. The SF curve from X-ray, when fitted to linear-quadratic (LQ) model, had 0.611 as ${\alpha}/{\beta}$ ratio (${\alpha}=0.0204,\;{\beta}=0.0334,\;R^2=0.999$, respectively). The SF curve from neutron beam had shoulders at low dose area and fitted well to LQ model with the value of $R^2$ exceeding 0.99 in all experiments. The mean value of alpha and beta were -0.315 (range, $-0.254{\sim}-0.360$) and 0.247 ($0.220{\sim}0.262$), respectively. The addition of lead shielding resulted in no straightening of SF curve and shoulders in low dose area still existed. The RBE of neutron beam was in range of $2.07{\sim}2.19$ with SF=0.1 and $2.21{\sim}2.35$ with SF=0.01, respectively. $\underline{Conclusion}$: The neutron beam from MC50 cyclotron has significant amount of gamma component and this may have contributed to form the shoulder of survival curve. The RBE of neutron beam generated by MC50 was about 2.2.