• Title/Summary/Keyword: Proton induced X-ray emission (PIXE)

Search Result 10, Processing Time 0.019 seconds

Oprimization Study for the CRC PIXE System Beam Transport Line

  • Jeong, Cheol-Ki;Lee, Goung-Jin
    • Journal of Radiation Industry
    • /
    • v.8 no.1
    • /
    • pp.59-63
    • /
    • 2014
  • Proton Induced X-ray Emission (PIXE) is a MeV ion beam analysis method for use with particle accelerators. PIXE uses low-energy charged particles as an excitation mechanism to generate characteristic x-ray emission from each element in a target. In PIXE analysis, the beam current used is from a few nA to several tens of nA. Chosun University (Cyclotron Research Center) designed a $50{\mu}A$ beam line from the 13 MeV cyclotron for use with a PIXE analysis system, as well as performing beam transport line optimization research. In this study, the beam line operation conditions for the optimization process of beam transport and beam characteristics are shown.

A Study on PIXE Spectrum Analysis for the Determination of Elemental Contents (원소별 함량결정을 위한 PIXE 스펙트럼 분석에 관한 연구)

  • Jong-Seok OH;;Hae-ILL Bak
    • Nuclear Engineering and Technology
    • /
    • v.22 no.2
    • /
    • pp.101-107
    • /
    • 1990
  • The PIXE (Proton Induced X-ray Emission) method is applied to the quantitative analysis of trace elements in tap water, red wine, urine and old black powder samples. Sample irradiations are performed with a 1.202 MeV proton beam from the SNU 1.5-MV Tandem Van de Graaff accelerator, and measurements of X-ray spectra are made by the Si(Li) spectrometer To increase the sensitivity of analysis tap water is preconcentrated by evaporation method. As an internal standard, Ni powder is mixed with black powder sample and yttrium solution is added to the other samples. The analyses of the PIXE spectra are carried out by using the AXIL (Analytical X-ray Analysis by Iterative Least-squares) computer code, in which the routine for least-squares method is based on the Marquardt algorithm. The elements such as Mg, Al, Si, Ti, Fe and Zn are analyzed at sub-ppm levels in the tap water sample. In the red wine sample prepared without preconcentration. the element Ti is detected in the amount of 3ppm. In conclusion, the PIXE method is proved to be appropriate for the analysis of liquid samples by relative measurements using the internal standard. and is expected to be improved by the use of evaluated X-ray production cross-sections and the development of sample preparation techniques.

  • PDF

Measurment of Gold Coating Thickness by PIXE (양성자 유발 X-선 발생법에 의한 금 박막의 두께 측정)

  • Kim, N.B.;Woo, H.J.;Kim, Y.S.;Kim, D.K.;Kim, J.K.;Choi, H.W.;Park, K.S.
    • Analytical Science and Technology
    • /
    • v.7 no.4
    • /
    • pp.471-476
    • /
    • 1994
  • The capability of PIXE (Proton Induced X-ray Emission) method for the precision measurement of coating thickness has been tested by measuring several gold coated copper plates. Two different experimental methods are applied and compared. The results are compared with those by the weight measurement and proton RBS (Rutherford Backscattering Spectrometry). The advantage of the method is that it can be also used for the nondestructive thickness measurement of this layers on large-scaled samples or archeological samples which cannot be placed in a vacuum chamber.

  • PDF

Elemental Analysis of Road Aerosols using by a PIXE Method (PIXE 분석법에 의한 도로변 분진의 원소분석)

  • 최금찬;임경택;조정구;김태형
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.12 no.5
    • /
    • pp.523-528
    • /
    • 1996
  • Aerosol Particles were collected in a heaby traffic region in pusan. Samples were collected in two size fractions with a two-stage sampler during the day and the night. Elemental concentrations of these aerosol particles were determined by a PIXE(Proton Induced X-ray Emission) analysis method. The results suggest that the elements originating mainly from natural sources such as Si, Ca, Fe, Cl, and K are dominent in the coarse fraction, but the elements such as S, Pb, Br, and Zn are dominent in the fine fraction. Br/Pb ratio are evaluated in both coarse and fine size fraction, and which are mainly emitted automobile sources. The study further also discussed other Br/Pb ratio related works described elsewhere. Sulfur in the fine fraction was continuously increased during the sampling period without time variation.

  • PDF

A Seasonal Variation of Elemental Composition of Fine Particles in Chongju Area using PIXE (PIXE를 이용한 청주지역 미세입자 중 원소의 계절 변동 특성)

  • 강병욱;이학성;김희강
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.13 no.4
    • /
    • pp.307-317
    • /
    • 1997
  • Samples of fine particle $(d_P<2.5 \mum)$ were taken in Chongju area using a dichotomous sampler. The data set was collected on fifty-eight different days with 24 hour sampling period from October 27, 1995 through August 25, 1996. The samples were analyzed using a proton induced x-ray emission (PIXE) for Na, Mg, Al, Si, S, Cl, K, Ca, Ti, V, Cr, M, Fe, Ni, Cu, Zn, Br and Pb. Values of Fe, Ca, Si, Cu, K and Cl exhibit marked seasonal variations. Mean concentrations for this study had the following order S > Cl > Si > K > Al > Fe on fine particle. Concentrations of Ca, Si and Fe were higher during the spring season compared with any other season. These phenomena may be attributable to soil dust. Cl and K were higher in the winter, which may be explained by combustion of fossil fuel. Higher values for Cu and Zn in the Winter may be due to the combustion and incineration.

  • PDF

A proton induced X-ray emission (PIXE) analysis of concentration of major/trace and toxic elements in broiler gizzard and flesh of Tehsil Gujar Khan area in Pakistan

  • Nadeem, Khawar;Hussain, Javaid;Haq, Noaman Ul;Haq, A. Ul;Akram, Waheed;Ahmad, Ishaq
    • Nuclear Engineering and Technology
    • /
    • v.51 no.8
    • /
    • pp.2042-2049
    • /
    • 2019
  • Ten gizzard and three flesh samples of the broiler were collected from different locations in Tehsil Gujar Khan District Rawalpindi, Pakistan. The samples were dried, crushed and ground. Pellets were prepared by pressing the powder of the samples and that of the Bovine liver 1577c reference material obtained from NIST, USA. Proton induced X-ray emission (PIXE) installed at National Center for Physics, Islamabad, Pakistan has been used as a reliable and improved technique to determine concentration of various major/trace and toxic elements e.g. S, Cl, K, Ca, Cl, Fe, Cu, Mn, Co, Zn, Ti, Cd, Ga, Cr, V and Ni, in the Gizzard and Flesh samples of the broiler. The concentrations of all the detected elements in the samples are statistically significant. The certified and measured values of the elements in the reference material were in agreement with each other within a deviation of 7%. S, Cl, K and Ca are within tolerable limits and are good for human consumption. Ti, V, Cr, Mn, Fe, Co, Ni, Cu and Zn were more than the acceptable limits of World Health Organization, WHO whereas Ga, As, Sn, Sb and Pb are not detected in most of the samples.

Analysis of Magnetic Multi-layers by RBS and PIXE (후방산란법(RBS)/양성자 여기 X-선 방출법(PIXE)을 이용한 다층자성박막의 두께 및 조성 정량분석)

  • 송종한;김태곤;전기영;황정남;신윤하;김영만;장성호;김광윤
    • Journal of the Korean Magnetics Society
    • /
    • v.11 no.6
    • /
    • pp.272-277
    • /
    • 2001
  • A spin valve structure of Ta/NiFe/CoFe/Cu/CoFe/Ru/CoFe/FeMn/Ta which has a synthetic antiferromagnet (CoFe/Ru/CoFe), was fabricated by using a magnetron sputtering system. The thickness and composition of magnetic free and pinned layers affect the magnetic properties such as exchange interaction strength of each layer and so on. Even though Rutherford Backscattering Spectrometry (RBS) has advantages of quantitative and non-destructive analysis, it is almost impossible to determine the thickness and composition of magnetic thin films using lBS because of its poor mass resolution for a higher atom number (Z>20). In this study, quantitative analysis of the element composition and thickness for the spin valve sample was performed by combining both Proton Induced X-ray Emission Spectrometry (PIXE), which is one of element specific analysis techniques, and grazing-exit RBS with a highly improved depth resolution and absolute quantitative analysis. For the quantitative analysis, standardization of PIXE was carried out with NiFe, CoFe, and FeMn layers, which are one of constituent layers of spin valve films. Through PIXE standardization and the aid of PHE experimental results of the spin valve sample, ire overlapped signal in a grazing-exit RBS spectrum were successfully resolved and the thickness of the Ru layer was determined with a resolution of ∼1 .

  • PDF

고에너지 이온선을 이용한 분석 기술

  • 김효배;송종한;김희중
    • Journal of the Korean Magnetics Society
    • /
    • v.6 no.2
    • /
    • pp.122-129
    • /
    • 1996
  • Fig. 1에서 보는 바와 같이 수 MeV의 에너지를 가진 입사이온이 고체 시료표면과 충돌했을 때 여러 가지의 상호작용과 과정들이 일어난다. 입사 아온이 표적원자의 원자가전자나 내각전자와 상호작용을 하였을 때 원자를 여기시키거나 이온화시키게 되며 입사 이온이 표적 핵과 매우 가까이 접근했을 때 입사이온과 표적 핵사이에 쿨롱상호작용이나 핵 상호작용이 일어나게 된다. 이러한 여러가지 상호작용의 결과들로부터 분석하고자 하는 시료의 성분, 구조, 상호작용 과정에 대한 정보를 얻을 수 있다. 이러한 고에너지 이온선을 이용한 분석기술로는 Fig. 1에서 보는 바와 같이 후방산란법(BS : Backscattering Spectrometry), 전방산란법(FRS : Forward Recoil Spectrometry), 핵반응법(NRA : Nuclear Reaction Analysis), 양성자여기X선검출법(PIXE : Proton Induced X-ray Emission)등과 이러한 방법들과 같이 조합하여 사용하는 이온 채널링(ion channeling)등이 있다. 본 해설에서는 이러한 분석법중에서도 널리 사용되고 있는 후방산란법과 이온 채널링에 대하여 주로 기술하고자 한다.

  • PDF

Modelling and packed bed column studies on adsorptive removal of phosphate from aqueous solutions by a mixture of ground burnt patties and red soil

  • Rout, Prangya R.;Dash, Rajesh R.;Bhunia, Puspendu
    • Advances in environmental research
    • /
    • v.3 no.3
    • /
    • pp.231-251
    • /
    • 2014
  • The present study examines the phosphate adsorption potential and behavior of mixture of Ground Burnt Patties (GBP), a solid waste generated from cooking fuel used in earthen stoves and Red Soil (RS), a natural substance in fixed bed column mode operation. The characterization of adsorbent was done by Proton Induced X-ray Emission (PIXE), and Proton Induced ${\gamma}$-ray Emission (PIGE) methods. The FTIR spectroscopy of spent adsorbent reveals the presence of absorbance peak at $1127cm^{-1}$ which appears due to P = O stretching, thus confirming phosphate adsorption. The effects of bed height (10, 15 and 20 cm), flow rate (2.5, 5 and 7.5 mL/min) and initial phosphate concentration (5 and 15 mg/L) on breakthrough curves were explored. Both the breakthrough and exhaustion time increased with increase in bed depth, decrease in flow rate and influent concentration. Thomas model, Yoon-Nelson model and Modified Dose Response model were used to fit the column adsorption data using nonlinear regression analysis while Bed Depth Service Time model followed linear regression analysis under different experimental condition to evaluate model parameters that are useful in scale up of the process. The values of correlation coefficient ($R^2$) and the Sum of Square Error (SSE) revealed the Modified Dose Response model as the best fitted model to the experimental data. The adsorbent mixture responded effectively to the desorption and reusability experiment. The results of this finding advocated that mixture of GBP and RS can be used as a low cost, highly efficient adsorbent for phosphate removal from aqueous solution.

PIXE Analysis for Elemental Analysis in Aerosol (PIXE 분석법을 이용한 대기분진 중 함유원소 분석)

  • Kim, Duk-Kyung;Choi, Han-Woo;Woo, Hyung-Joo;Kim, Young-Suk;Hong, Wan;Kim, Nak-Bae;Lee, Jin-Hong
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.10 no.2
    • /
    • pp.90-97
    • /
    • 1994
  • PIXE( Proton Induced X- ray Emission ) analysis has been applied to the analysis of aerosol for the Purpose of pollution monitoring. Coarse and fine Particle fractions were sampled selectively, using Nuclepore filter in stacked filter units, once a month from February to September in 1993 at urban and rural sites. Concentration of 9 elements, Si, S, K, Ca, Mn, Fe, Cu, Zn and Pb was determined without Pretreatment of Samples. Comparison of data between urban and rural site revealed higher elemental concentration level in urban aerosol. From April to May aerosol sampling was carried out daily to observe the effect of Yellow Sand on the composition of aerosol in the Korean Peninsula. During the Yellow Sand period, Si, Ca, Fe content level in aerosol became more than 5 times higher than normal. The elemental concentration of the aerosol samples of Daejeon City was compared with that of two foreign cities. S and Pb( which are fuel- derived elements) levels in Daejeon City aerosol appeared to be lower than those of foreign cities. And it may be due to the leaded-fuel restriction policy of Korean government since 1987.

  • PDF