• Title/Summary/Keyword: Proton exchange membrane fuel cell (PEMFC)

Search Result 262, Processing Time 0.024 seconds

Analysis of R&D Investment for Hydrogen and Fuel Cell (수소.연료전지 연구개발 투자현황 분석)

  • Park, No-Eon;Kim, Hyung-Wook
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.21 no.2
    • /
    • pp.143-148
    • /
    • 2010
  • Research and Development (R&D) investment of hydrogen and fuel cell, funded by government from 2007 to 2008 in Korea, has been analyzed. R&D investment of hydrogen and fuel cell in 2008 would see 9% and 29% of total budget in the field of renewable energy, respectively. It was found that R&D investment is mainly dependent on mission of Ministry in Korea. Basic and apply research would be mainly invested by Ministry of Education, Science and Technology (MEST), while development research would be conducted by Ministry of Knowledge Economy (MKE). In R&D investment by performer, hydrogen technology would be conducted by government-funded institute and university. It was also shown that funds for hydrogen production have been much supported than hydrogen storage. Meanwhile, fuel cell would be mainly conducted by major companies. It was also shown that funds for proton exchange membrane fuel cell (PEMFC) have been much invested than other technology in fuel cell.

Synthesis of Crosslinkable m-Aramid Ionomer Containing Sulfonated Ether Sulfone and Their Characterization for PEMFC Membrane (Sulfonated Ether Sulfone을 포함한 Crosslinkable m-Aramid계 Ionomer의 합성과 연료전지 막으로의 이용)

  • Jung, Hyun-Jin;Kim, Jung-Min;Cho, Chang-Gi
    • Polymer(Korea)
    • /
    • v.34 no.3
    • /
    • pp.202-209
    • /
    • 2010
  • Aromatic copolyamides were prepared and their applicability to proton exchange membrane wasstudied. The copolymer contains thermally stable and mechanically strong poly(m-phenylene isophthalamide) segments, and easily processable and good film forming polysulfone segments. For the copolymer, amineterminated sulfonated ether sulfone monomer, m-phenylene diamine, and isophthaloyl chloride were reacted, and the obtained copolymer was transformed into crosslinkable prepolymer by the reaction with acryloyl chloride. The prepolymer was thermally cured and converted into proton exchange membranes for fuel cell application. Each reaction step and the molecular characteristics of precursor copolymers were monitored and confirmed by $^1H$ NMR, FTIR, and titration. The performance of the membranes was measured in terms of water uptake, proton conductivity, and thermal stability. The water uptake, ion exchange capacity (IEC), and proton conductivity of the membranes increased with the increase of sulfonated ether sulfone segment content. Membrane containing 30 mol% sulfonic acid sulfone segment showed 1.57 meq/g IEC value. Water uptake was limited less than 44 wt% and the highest proton conductivity up to $3.93{\times}10^{-2}S/cm$ ($25^{\circ}C$, RH= 100%) was observed.

Fuel Cell Modeling with Output Characteristics of Boost Converter (연료전지 모델링 및 부스트 컨버터 출력 특성)

  • Park, Bong-Hee;Choi, Ju-Yeop;Choy, Ick;Lee, Sang-Cheol;Lee, Dong-Ha
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.1
    • /
    • pp.91-97
    • /
    • 2014
  • This paper proposes a modeling of fuel cell which replaces dc source during simulation. Fuel cells are electrochemical devices that convert chemical energy in fuels into electrical energy. This system has high efficiency and heat, no environmental chemical pollutions and noise. Proton exchange membrane fuel cells (PEMFC) are commonly used as a residential generator. These fuel cells have different electrical characteristics such as a low voltage and high current compared with solar cells. And there are different behaviors in the V-I curve in the temperature and pressure. Therefore, the modeling of fuel cell should consider wide voltage range and slow current response and the resulting electrical model is applied to boost converter with fuel cell as an input source.

Variation of Hydrogen Peroxide Concentration during Fenton Reaction for Test the Membrane Durability of PEMFC (PEMFC 고분자막 내구 평가를 위한 Fenton 반응에서 과산화수소 농도 변화에 관한 연구)

  • Oh, Sohyung;Kim, Jeongjae;Lee, Daewoong;Park, Kwonpil
    • Korean Chemical Engineering Research
    • /
    • v.56 no.3
    • /
    • pp.315-319
    • /
    • 2018
  • Fenton reaction is widely used as a out of cell method for evaluating the membrane electrochemical durability of Proton Exchange Fuel Cell (PEMFC). In this study, we investigated the factors affecting the Fenton reaction. In order to estimate the degree of the reaction, it is necessary to analyze the radicals as a product in the Fenton reaction. However, since the radicals are difficult to analyze, the degree of the reaction was measured by analyzing the concentration of hydrogen peroxide. The activation energy was calculated from the rate of hydrogen peroxide change with temperature. The activation energy was 24.9 kJ/mol at 180 min. The Fenton reaction rate was affected by the iron ion concentration. At $80^{\circ}C$, 200 rpm, and $Fe^{2+}$ 80 ppm, the concentration of hydrogen peroxide was decreased more than 20% even for 1 hour, which shows that frequent solution replacement increases the membrane degradation rate.

Comparison between CFD Analysis and Experiments According to Various PEMFC Flow-field Designs

  • Lee, Kang-In;Lee, Se-Won;Park, Min-Soo;Cho, Yong-Hun;Cho, Yoon-Hwan;Chu, Chong-Nam;Sung, Yung-Eun
    • Journal of the Korean Electrochemical Society
    • /
    • v.12 no.1
    • /
    • pp.61-67
    • /
    • 2009
  • Flow-field design has much influence over the performance of proton exchange membrane fuel cell (PEMFC) because it affects the pressure magnitude and distribution of the reactant gases. To obtain the pressure magnitude and distribution of reactant gases in five kinds of flow-field designs, computational fluid dynamics (CFD) analysis was performed. After the CFD analysis, a single cell test was carried out to obtain the performance values. As expected, the pressure differences due to different flow-field configurations were related to the PEMFC performance because the actual performance results showed the same tendency as the results of the CFD analysis. A large pressure drop resulted in high PEMFC performance. The single serpentine configuration gave the highest performance because of the high pressure difference magnitudes of the inlet/outlet. On the other hand, the parallel flow-field configuration gave the lowest performance because the pressure difference between inlet and outlet was the lowest.

Design Optimization of a 500W Fuel Cell Stack Weight for Small Robot Applications (소형로봇용 500W급 연료전지 스택무게 최적화 설계)

  • Hwang, S.W.;Choi, G.H.;Park, Sam.;Ench, R. Michael;Bates, Alex M.;Lee, S.C.;Kwon, O.S.;Lee, D.H.
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.spc3
    • /
    • pp.275-281
    • /
    • 2012
  • Proton Exchange Membrane Fuel Cells (PEMFC) are the most appropriate for energy source of small robot applications. PEMFC has superior in power density and thermodynamic efficiency as compared with the Direct Methaol Fuel Cell (DMFC). Furthermore, PEMFC has lighter weight and smaller size than DMFC which are very important factors as small robot power system. The most significant factor of mobile robots is weight which relates closely with energy consumption and robot operation. This research tried to find optimum specifications in terms of type, number of cell, active area, cooling method, weight, and size. In order to find optimum 500W PEMFC, six options are designed in this paper and studied to reduce total stack weight by applying new materials and design innovations. However, still remaining problems are thermal management, robot space for energy sources, and soon. For a thermal management, design options need to analysis of Computational Fluid Dynamics (CFD) for determining which option has the improved performance and durability.

Optimization of a Fuel Cell Stack for Small Robot Systems (소형 로봇용 연료 전지 스택 설계 사양 최적화)

  • Hwang, S.W.;Choi, G.H.;Park, Sam.;Ench, R. Michael;Bates, Alex M.;Lee, S.C.;Kwon, O.S.;Lee, D.H.
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2012.03a
    • /
    • pp.211-216
    • /
    • 2012
  • Proton Exchange Membrane Fuel Cells (PEMFC) are the most appropriate for energy source of small robot applications. PEMFC has superior in power density and thermodynamic efficiency as compared with the Direct Methaol Fuel Cell (DMFC). Furthermore, PEMFC has lighter weight and smaller size than DMFC which are very important factors as small robot power system. The most significant factor of mobile robots is weight which relates closely with energy consumption and robot operation. This research tried to find optimum specifications in terms of type, number of cell, active area, cooling method, weight, and size. In order to find optimum 500W PEMFC, six options are designed in this paper and studied to reduce total stack weight by applying new materials and design innovations. However, still remaining problems are thermal management, robot space for energy sources, and so on. For a thermal management, design options need to analysis of Computational Fluid Dynamics (CFD) for determining which option has the improved performance and durability.

  • PDF

Study on Corrosion Problems in PEMFC Cooling System (PEMFC 냉각 시스템의 물부식 방지에 관한 연구)

  • Park, Kwang-Jin;Jeong, Jae-Hwa;Kim, Jung-Hyun;Bae, Joong-Myeon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.31 no.12
    • /
    • pp.1188-1193
    • /
    • 2007
  • This study focuses on the corrosion problems of STS316(stainless steel 316) tube for the cooling system of PEMFC (Proton Exchange Membrane Fuel Cell) operation. Deionized water which is highly corrosive is used especially for cooling agent of PEMFC to eliminate electrical conductivity, The tensile stress analysis was performed to check the change of mechanical strength of cooling line and pH of the water was monitored for the observation of extent of corrosion at simulated PEMFC operating condition. When STS316 tube was exposed to deionized water for 500 hours, substantial cracks were found on the surface and the pH of water was decreased from 6.8 to 5.8. For prevention of corrosion problems, the STS316 was coated by three kinds of fluororesin such as PTFE, FEP and ETFE. Among the coating materials, PTFE was the most protective in corrosive environment and was maintained the mechanical strength. To lower the cost, the same experimental analyses were carried out for iron tubes and the result will be discussed in detail.

First Principles Computational Study of Surface Reactions Toward Design Concepts of High Functional Electrocatalysts for Oxygen Reduction Reaction in a Fuel Cell System

  • Hwang, Jeemin;Noh, Seunghyo;Kang, Joonhee;Han, Byungchan
    • Journal of the Korean institute of surface engineering
    • /
    • v.50 no.1
    • /
    • pp.1-9
    • /
    • 2017
  • Design of novel materials in renewable energy systems plays a key role in powering transportation vehicles and portable electronics. This review introduces the research work of first principles-based computational design for the materials over the last decade to accomplish the goal with less financial and temporal cost beyond the conventional approach, especially, focusing on electrocatalyst toward a proton exchange membrane fuel cell (PEMFC). It is proposed that the new method combined with experimental validation, can provide fundamental descriptors and mechanical understanding for optimal efficiency control of a whole system. Advancing these methods can even realize a computational platform of the materials genome, which can substantially reduce the time period from discovery to commercialization into markets of new materials.

PSIM Model of a Single-Phase Fuel Cell Power Generator (단상 연료전지 발전장치의 PSIM 모델)

  • Oum, J.H.;Kim, J.H.;Lim, Y.C.;Jung, Y.G.
    • Proceedings of the KIPE Conference
    • /
    • 2008.06a
    • /
    • pp.304-307
    • /
    • 2008
  • 일반적으로 마이크로 전원으로 연료전지 발전장치는 100w ~수백kw의 용량을 가지며 종전의 대규모 전력설비와 비교하여 높은 신뢰도를 갖는 고품질의 전력을 공급할 수 있다. 본 연구에서는 소형 분산에너지원으로서 PEMFC(Proton Exchange Membrane Fuel Cell )연료전지를 사용하는 발전장치의 PSIM 모델을 설정하고 부하변화에 대한 연료전지 발전장치의 출력전압의 강인성을 살펴보았다. 연료전지 발전장치의 교류출력의 강인성은 선형 부하 및 비선형 부하가 급변하는 과도상태에서 파악하였다.

  • PDF