• Title/Summary/Keyword: Protocols

Search Result 3,973, Processing Time 0.034 seconds

Suggested Protocol for Efficient Medical Image Information Exchange in Korea: Breast MRI (효율적 의료영상정보교류를 위한 프로토콜 제안: 유방자기공명영상)

  • Park, Ji Hee;Choi, Seon-Hyeong;Kim, Sungjun;Yong, Hwan Seok;Woo, Hyunsik;Jin, Kwang Nam;Jeong, Woo Kyoung;Shin, Na-Young;Choi, Moon Hyung;Jung, Seung Eun
    • Journal of the Korean Society of Radiology
    • /
    • v.79 no.5
    • /
    • pp.254-258
    • /
    • 2018
  • Purpose: Establishment of an appropriate protocol for breast magnetic resonance imaging (MRI) in the study of image quality standards to enhance the effectiveness of medical image information exchange, which is part of the construction and activation of clinical information exchange for healthcare informatization. Materials and Methods: The recommended protocols of breast and MRI scans were reviewed and the questionnaire was prepared by a responsible researcher. Then, a panel of 9 breast dedicated radiologists was set up in Korea. The expert panel conducted a total of three Delphi agreements to draw up a consensus on the breast MRI protocol. Results: The agreed breast MRI recommendation protocol is a 1.5 Tesla or higher device that acquires images with prone position using a breast dedicated coil and includes T2-weighted and pre-contrast T1-weighted images. Contrast enhancement images are acquired at least two times, and include 60-120 seconds between images and after 4 minutes. The contrast enhancement T1-weighted image should be less than 3 mm in thickness, less than 120 seconds in temporal resolution, and less than $1.5mm^2$ in-plane pixel resolution. Conclusion: The Delphi agreement of the domestic breast imaging specialist group has established the recommendation protocol of the effective breast MRI.

A Study on the Methods of Mounting the Five Peaks Screen - With the focus on green bordering silk and gilt ornamentation (궁중 의례용 일월오봉도 병풍의 장황에 관한 고찰 - 초록색 회장 비단과 금박 장식을 중심으로 -)

  • PARK, Yoonhee
    • Korean Journal of Heritage: History & Science
    • /
    • v.55 no.1
    • /
    • pp.243-263
    • /
    • 2022
  • The royal court of Joseon had a tradition of mounting the Irworobongdo, a painting of the sun, the moon and the five sacred peaks, symbols of the king's immortal presence and authority, on a folding screen and placing it in special spaces within the palace that were reserved for the king. While the Irworobongdo is generally accepted as the important ceremonial object of the royal palaces of Joseon, there have been few studies on the various folding screens used in the royal palaces, largely because the official records about such screens do not match the remaining original relics. In this study, the main discussion is focused on the diversity of the shapes and mounting materials of the Irworobongdoused for various ceremonies held in the royal palaces of Joseon based on the Uigwe, the official records of the royal protocols of the Joseon dynasty. The discussion also extends to the theme rarely studied so far, namely the original form of the Irworobongdo and its evolution in the following period. The ceremonial "five peak" folding screens (Obongbyeong) used at a number of important palace buildings, including the crown hall (Jeongjeon), royal funerary hall (Binjeon), spirit hall (Honjeon) and portrait shrine (Jinjeon), differed in shape and size from the folding screens used in royal celebratory events such as banquets, although the paintings themselves and the style of mounting them were essentially the same. The paintings were mounted on screens bordered with green silk and ornamented with floral gilt designs. The folding screens used in royal ceremonies were produced according to strict guidelines that required the ceremonies and mounting materials to be graded on the basis of the status of each screen. It was not until the 1960s that these ceremonial folding screens of the Joseon dynasty, which had been neglected during the period of Japanese colonial rule of Korea, began to undergo conservation treatment provided as part of a heritage preservation program. Unfortunately, many of the screens repaired in this period lost some of their original features - largely due to the use of non-traditional mounting techniques. Considering, however, that significant achievements have since been made in the heritage preservation field based on the use of historical evidence, it is now necessary to systematically use the repair history of the information about the remaining royal ceremonial folding screens to ensure that they are preserved and managed more effectively in the future.

Development and Testing of the Model of Health Promotion Behavior in Predicting Exercise Behavior

  • O'Donnell, Michael P.
    • Korean Journal of Health Education and Promotion
    • /
    • v.2 no.1
    • /
    • pp.31-61
    • /
    • 2000
  • Introduction. Despite the fact that half of premature deaths are caused by unhealthy lifestyles such as smoking tobacco, sedentary lifestyle, alcohol and drug abuse and poor nutrition, there are no theoretical models which accurately explain these health promotion related behaviors. This study tests a new model of health behavior called the Model of Health Promotion Behavior. This model draws on elements and frameworks suggested by the Health Belief Model, Social Cognitive Theory, the Theory of Planned Action and the Health Promotion Model. This model is intended as a general model of behavior but this first test of the model uses amount of exercise as the outcome behavior. Design. This study utilized a cross sectional mail-out, mail-back survey design to determine the elements within the model that best explained intentions to exercise and those that best explained amount of exercise. A follow-up questionnaire was mailed to all respondents to the first questionnaire about 10 months after the initial survey. A pretest was conducted to refine the questionnaire and a pilot study to test the protocols and assumptions used to calculate the required sample size. Sample. The sample was drawn from 2000 eligible participants at two blue collar (utility company and part of a hospital) and two white collar (bank and pharmaceutical) companies located in Southeastern Michigan. Both white collar site had employee fitness centers and all four sites offered health promotion programs. In the first survey, 982 responses were received (49.1%) after two mailings to non-respondents and one additional mailing to secure answers to missing data, with 845 usable cases for the analyzing current intentions and 918 usable cases for the explaining of amount of current exercise analysis. In the follow-up survey, questionnaires were mailed to the 982 employees who responded to the initial survey. After one follow-up mailing to non-respondents, and one mailing to secure answers to missing data, 697 (71.0%) responses were received, with 627 (63.8%) usable cases to predict intentions and 673 (68.5%) usable cases to predict amount of exercise. Measures. The questionnaire in the initial survey had 15 scales and 134 items; these scales measured each of the variables in the model. Thirteen of the scales were drawn from the literature, all had Cronbach's alpha scores above .74 and all but three had scores above .80. The questionnaire in the second mailing had only 10 items, and measured only outcome variables. Analysis. The analysis included calculation of scale scores, Cronbach's alpha, zero order correlations, and factor analysis, ordinary least square analysis, hierarchical tests of interaction terms and path analysis, and comparisons of results based on a random split of the data and splits based on gender and employer site. The power of the regression analysis was .99 at the .01 significance level for the model as a whole. Results. Self efficacy and Non-Health Benefits emerged as the most powerful predictors of Intentions to exercise, together explaining approximately 19% of the variance in future Intentions. Intentions, and the interaction of Intentions with Barriers, with Support of Friends, and with Self Efficacy were the most consistent predictors of amount of future exercise, together explaining 38% of the variance. With the inclusion of Prior Exercise History the model explained 52% of the variance in amount of exercise 10 months later. There were very few differences in the variables that emerged as important predictors of intentions or exercise in the different employer sites or between males and females. Discussion. This new model is viable in predicting intentions to exercise and amount of exercise, both in absolute terms and when compared to existing models.

  • PDF

Research to Establish a Common Standard for Assent by Assessing the Current State of the Assent Process and Conducting Interviews with Pediatrician/Pediatric Neurologist (소아승낙 현황조사와 소아청소년과/소아신경과 전문의를 대상으로 면담조사를 통한 소아승낙서 공통기준 수립 연구)

  • Yoon Jin Lee;Sun Ju Lee;Su Jin Kang;Dae Ho Lee;Kyun-Seop Bae;Jong Woo Chung;Byung Soo Kim;Jin Seok Kim;Myung Ah Lee
    • The Journal of KAIRB
    • /
    • v.6 no.1
    • /
    • pp.5-16
    • /
    • 2024
  • Purpose: The purpose of this study is to investigate the current status of pediatric assent in nationwide hospitals and to assess the children's comprehension for pediatric assent by interviewing pediatricians/pediatric neurologists to determine whether children of the age (elementary and middle school students) can understand the purpose, risks, benefits, and concepts of voluntary participation in clinical research described in the assent form, and to help improve the administrative efficiency of multicenter clinical trials. Methods: The status of pediatric assent was surveyed online using Google Forms at 141 university hospitals with administrative staff who are members of the Institutional Review Board (IRB) administrative staff subcommittee with in Korean Association of Institutional Review Boards (KAIRB). Additionally, face-to-face interviews were conducted with 7 pediatricians/pediatric neurologists. Survey and interview responses were summarized using descriptive statistics. Results: Out of the 141 institutions surveyed, 35 institutions (24.8%) responded. Among them, 30 institutions (85.7%) reported having age criteria for acquiring pediatric assent forms in the case of children. The age range for pediatric assent acquisition have been from 7 years old to 12 years old (15 institutions, 50%), and from 7 years old to 15 years old (7 institutions, 23.3%). Nine institutions (25.7%) have had criteria for obtaining both parents' consent in cases involving the participation of children. Nineteen institutions (54.3%) have had checklists or guidelines available for use by IRB members in study protocols involving vulnerable research subjects. Three pediatricians/pediatric neurologists have believed that upper-grade elementary school students (5th-6th grade) could comprehensively understand informed consent forms. Two have believed that middle school students would be able to understand them if they included personal information. Two pediatricians/pediatric neurologists have believed that even lower-grade elementary school students (1st-4th grade) could understand the explanations if they were made simpler. Conclusion: It is suggested that not only elementary school students (7-12 years old) but also middle school students (13-15 years old) should receive pediatric assent forms, as it would facilitate a comprehensive understanding of the forms. To enhance the comprehension of assent form content, it is necessary to use age-appropriate words, language, and expressions in the forms hospital. It is also recommended to create comics or videos to make the content of the assent forms more accessible for children.

  • PDF

Generative Adversarial Network-Based Image Conversion Among Different Computed Tomography Protocols and Vendors: Effects on Accuracy and Variability in Quantifying Regional Disease Patterns of Interstitial Lung Disease

  • Hye Jeon Hwang;Hyunjong Kim;Joon Beom Seo;Jong Chul Ye;Gyutaek Oh;Sang Min Lee;Ryoungwoo Jang;Jihye Yun;Namkug Kim;Hee Jun Park;Ho Yun Lee;Soon Ho Yoon;Kyung Eun Shin;Jae Wook Lee;Woocheol Kwon;Joo Sung Sun;Seulgi You;Myung Hee Chung;Bo Mi Gil;Jae-Kwang Lim;Youkyung Lee;Su Jin Hong;Yo Won Choi
    • Korean Journal of Radiology
    • /
    • v.24 no.8
    • /
    • pp.807-820
    • /
    • 2023
  • Objective: To assess whether computed tomography (CT) conversion across different scan parameters and manufacturers using a routable generative adversarial network (RouteGAN) can improve the accuracy and variability in quantifying interstitial lung disease (ILD) using a deep learning-based automated software. Materials and Methods: This study included patients with ILD who underwent thin-section CT. Unmatched CT images obtained using scanners from four manufacturers (vendors A-D), standard- or low-radiation doses, and sharp or medium kernels were classified into groups 1-7 according to acquisition conditions. CT images in groups 2-7 were converted into the target CT style (Group 1: vendor A, standard dose, and sharp kernel) using a RouteGAN. ILD was quantified on original and converted CT images using a deep learning-based software (Aview, Coreline Soft). The accuracy of quantification was analyzed using the dice similarity coefficient (DSC) and pixel-wise overlap accuracy metrics against manual quantification by a radiologist. Five radiologists evaluated quantification accuracy using a 10-point visual scoring system. Results: Three hundred and fifty CT slices from 150 patients (mean age: 67.6 ± 10.7 years; 56 females) were included. The overlap accuracies for quantifying total abnormalities in groups 2-7 improved after CT conversion (original vs. converted: 0.63 vs. 0.68 for DSC, 0.66 vs. 0.70 for pixel-wise recall, and 0.68 vs. 0.73 for pixel-wise precision; P < 0.002 for all). The DSCs of fibrosis score, honeycombing, and reticulation significantly increased after CT conversion (0.32 vs. 0.64, 0.19 vs. 0.47, and 0.23 vs. 0.54, P < 0.002 for all), whereas those of ground-glass opacity, consolidation, and emphysema did not change significantly or decreased slightly. The radiologists' scores were significantly higher (P < 0.001) and less variable on converted CT. Conclusion: CT conversion using a RouteGAN can improve the accuracy and variability of CT images obtained using different scan parameters and manufacturers in deep learning-based quantification of ILD.

Comparison of In Vitro, Ex Vivo, and In Vivo Antibacterial Activity Test Methods for Hand Hygiene Products (손 위생 제품에 대한 in vitro, ex vivo, in vivo 항균 시험법 비교)

  • Daeun Lee;Hyeonju Yeo;Haeyoon Jeong
    • Journal of Food Hygiene and Safety
    • /
    • v.39 no.1
    • /
    • pp.35-43
    • /
    • 2024
  • Numerous methods have been applied to assess the antibacterial effectiveness of hand hygiene products. However, the different results obtained through various evaluation methods have complicated our understanding of the real efficacy of the products. Few studies have compared test methods for assessing the efficacy of hand hygiene products. In particular, reports on ex vivo pig skin testing are limited. This study aimed to compare and characterize the methodologies applied for evaluating hand hygiene products, involving in vitro, ex vivo, and in vivo approaches, applicable to both leave-on sanitizers and wash-off products. Our further aim was to enhance the reliability of ex vivo test protocols by identifying influential factors. We performed an in vitro method (EN1276) and an in vivo test (EN1499 and ASTM2755) with at least 20 participants, against Serratia marcescens or Escherichia coli and Staphylococcus aureus. For the ex vivo experiment, we used pig skin squares prepared in the same way as those used in the in vivo test method and determined the optimal treated sample volumes for sanitizers and the amount of water required to wash off the product. The hand sanitizers showed at least a 5-log reduction in bacterial load in the in vitro test, while they showed little antibacterial activity in the in vivo and ex vivo tests, particularly those with a low alcohol content. For the hand wash products, the in vitro test was limited because of bubble formation or the high viscosity of the products and it showed low antibacterial activity of less than a 1-log reduction against E. coli. In contrast, significantly higher log reductions were observed in ex vivo and in vivo tests, consistently demonstrating these results across the two methods. Our findings revealed that the ex vivo and in vivo tests reflect the two different antibacterial mechanisms of leave-on and wash-off products. Our proposed optimized ex vivo test was more rapid and more precise than the in vitro test to evaluate antibacterial results.

The Significance of Hyperlipidemia as a Predictive Factor of Relapse in Corticosensitive Nephrotic Syndrome (스테로이드에 반응을 보인 신증후군 환아에서 재발 예측인자로서 고지혈증의 중요성)

  • Jung, Soon-Pil;Hong, Soon-Cheul;Lim, Seong-Joon;Lim, In-Seok;Choi, Eung-Sang
    • Childhood Kidney Diseases
    • /
    • v.5 no.2
    • /
    • pp.136-146
    • /
    • 2001
  • Purpose : One of the most difficult problems in the care of children with nephrotic syndrome remains the occurrence of relapses, despite initial response to steroids. Constantinescu reported that rapidity of initial response to steroid therapy could predict fewer relapses in the first year. So we evaluated the changes in serum lipid abnormalities in children with corticosensitive nephrotic syndrome before steroid treatment and the correlation between serum lipid levels and renal function, days to remission. Methods . We analyzed the Medical records of children who were managed by us between October 1994 and August 2000. In 33 patients with corticosensitive nephrotic syndrome, we evaluated the correlation between serum lipid levels and renal function [Creatinine clearance(Ccr)] and proteinuria before steroid treatment, and days to remission defined as the third day when the patient's urine becomes protein free. Results : There were 21 males and 12 females. Median age at presentation was 6.4 years (range: 1.8-17.3 years). Median days to remission were 15.4 days (range 4-42 days) on Prednisolone $60mg/m^2$ daily. The increased levels of triglyceride, total cholesterol, LDL cholesterol, apolipoprotein B, total cholesterol/HDL cholesterol, Lipoprotein(a) were observed. But the level of HDL cholesterol was not increased. Serum albumin was decreased a]id proteinuria was increased before steroid treatment. But Ccr was not decreased. There were negative correlation between serum albumin and total cholesterol (r = -0.5157, P<0.005), LDL cholesterol (r = -0.5543, P<0.005), total cholesterol/HDL cholesterol (r = -0.4506, P<0.01), lipoprotein(a) (r = -0.4570, P<0.025), apolipoprotein B (r = -0.5297, P<0.025), apolipoprotein B/apolipoprotein Al (r = -0.5851, P<0.01), apolipoprotein B/HDL cholesterol (r = -0.4961, P<0.05) before steroid treatment. There was no correlation between proteinuria and serum lipid profiles. Also Ccr and serum lipid profiles were not correlated. There was positive correlation between days to remission and HDL cholesterol (r = +0.4511, P<0.05), apolipoprotein B (r = +0.5190, P<0.05), apolipoprotein B/HDL cholesterol (r = +0.7169, P<0.005). Conclusions : This results reveal that HDL cholesterol, apolipoprotein B and apolipoprotein B/HDL cholesterol can be used as a predictive factor in corticosensitive nephrotic syndrome. We could not determine the significant level of these lipids for insufficient patients number, but these level may predict future relapses of corticosensitive nephrotic syndrome patients and thus may allow to better management and treatment protocols. More data and long term follow up studies should be needed. (J Korean Soc Pediatr Nephrol 2001;5 : 136-46)

  • PDF

A Study on an Effective Decellularization Technique for a Xenograft Cardiac Valve: the Effect of Osmotic Treatment with Hypotonic Solution (이종 심장 판막 이식편에서 효과적인 탈세포화 방법에 관한 연구; 저장성 용액(hypotonic solution)의 삼투압 처치법 효과)

  • Sung, Si-Chan;Kim, Yong-Jin;Choi, Sun-Young;Park, Ji-Eun;Kim, Kyung-Hwan;Kim, Woong-Han
    • Journal of Chest Surgery
    • /
    • v.41 no.6
    • /
    • pp.679-686
    • /
    • 2008
  • Background: Cellular remnants in the bioprosthetic heart valve are known to be related to a host's immunologic response and they can form the nidus for calcification. The extracellular matrix of the decellularized valve tissue can also be used as a biological scaffold for cell attachment, endothelialization and tissue reconstitution. Thus, decellularization is the most important part in making a bioprosthetic valve and biological caffold. Many protocols and agents have been suggested for decellularization, yet there ave been few reports about the effect of a treatment with hypotonic solution prior to chemical or enzymatic treatment. This study investigated the effect of a treatment with hypotonic solution and the appropriate environments such as temperature, the treatment duration and the concentration of sodium dodecylsulfate (SDS) for achieving proper decellularization. Material and Method: Porcine aortic valves were decellularized with odium dodecylsulfate at various concentrations (0.25%, 0.5%), time durations (6, 12, 24 hours) and temperatures ($4^{\circ}C$, $20^{\circ}C$)(Group B). Same the number of porcine aortic valves (group A) was treated with hypotonic solution prior to SDS treatment at the same conditions. The duration of exposure to the hypotonic solution was 4, 7 and 14 hours and he temperature was $4^{\circ}C$ and $20^{\circ}C$, respectively. The degree of decellularization was analyzed by performing hematoxylin and eosin staining. Result: There were no differences in the degree of decellularization between the two concentrations (0.25% 0.5%) of SDS. Twenty four hours treatment with SDS revealed the best decellularization effect for both roups A and B at the temperature of $4^{\circ}C$, but there was no differences between the roups at $20^{\circ}C$. Treatment with hypotonic solution (group A) showed a better ecellularization effect at all the matched conditions. Fourteen hours treatment at $4^{\circ}C$ ith ypotonic solution prior to 80S treatment revealed the best decellularization effect. The treatment with hypotonic solution at $20^{\circ}C$ revealed a good decellularization effect, but his showed significant extracellular matrix destruction. Conclusion: The exposure of porcine heart valves to hypotonic solution prior to SDS treatment is highly effective for achieving decellularization. Osmotic treatment with hypotonic solution should be considered or achieving decellularization of porcine aortic valves. Further study should be carried out to see whether the treatment with hypotonic solution could reduce the exposure duration and concentration of chemical detergents, and also to evaluate how the structure of the extracellular matrix of the porcine valve is affected by the exposure to hypotonic solution.

The study of MDCT of Radiation dose in the department of Radiology of general hospitals in the local area (일 지역 종합병원 영상의학과 MDCT선량에 대한 연구)

  • Shin, Jung-Sub
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.4
    • /
    • pp.281-290
    • /
    • 2012
  • The difference of radiation dose of MDCT due to different protocols between hospitals was analyzed by CTDI, DLP, the number of Slice and the number of DLP/Slice in 30 cases of the head, the abdomen and the chest that have 10 cases each from MDCT examination of the department of diagnostic imaging of three general hospitals in Gyeongsangbuk-do. The difference of image quality, CTDI, DLP, radiation dose in the eye and radiation dose in thyroid was analyzed after both helical scan and normal scan for head CT were performed because a protocol of head CT is relatively simple and head CT is the most frequent case. Head CT was significantly higher in two-thirds of hospitals compared to A hospital that does not exceed a CTDI diagnostic reference level (IAEA 50mGy, Korea 60mGy) (p<0.001). DLP was higher in one-third of hospitals than a diagnostic reference level of IAEA 1,050mGy.cm and Korea 1,000mGy.cm and two-thirds exceeded the recommendation of Korea and those were significantly higher than A hospital that does not exceed a diagnostic reference level (p<0.001). Abdomen CT showed 119mGy that was higher than a diagnostic reference level of IAEA 25mGy and Korea 20mGy in one-third. DLP in all hospitals was higher that Korea recommendation of 700mGy.cm. Among target hospitals, C hospital showed high radiation dose in all tests because MPR and 3D were of great importance due to low pitch and high Tube Curren. To analyze the difference of radiation dose by scan methods, normal scan and helical scan for head CT of the same patient were performed. In the result, CTDI and DLP of helical CT were higher 63.4% and 93.7% than normal scan (p<0.05, p<0.01). However, normal scan of radiation dose in thyroid was higher 87.26% (p<0.01). Beam of helical CT looked like a bell in the deep part and the marginal part so thyroid was exposed with low radiation dose deviated from central beam. In addition, helical scan used Gantry angle perpendicularly and normal scan used it parallel to the orbitomeatal line. Therefore, radiation dose in thyroid decreased in helical scan. However, a protocol in this study showed higher radiation dose than diagnostic reference level of KFDA. To obey the recommendation of KFDA, low Tube Curren and high pitch were demanded. In this study, the difference of image quality between normal scan and helical scan was not significant. Therefore, a standardized protocol of normal scan was generally used and protective gear for thyroid was needed except a special case. We studied a part of CT cases in the local area. Therefore, the result could not represent the entire cases. However, we confirmed that patient's radiation dose in some cases exceeded the recommendation and the deviation between hospitals was observed. To improve this issue, doctors of diagnostic imaging or technologists of radiology should perform CT by the optimized protocol to decrease a level of CT radiation and also reveal radiation dose for the right to know of patients. However, they had little understanding of the situation. Therefore, the effort of relevant agencies with education program for CT radiation dose, release of radiation dose from CT examination and addition of radiation dose control and open CT contents into evaluation for hospital services and certification, and also the effort of health professionals with the best protocol to realize optimized CT examination.

Performance Characteristics of 3D GSO PET/CT Scanner (Philips GEMINI PET/DT) (3차원 GSO PET/CT 스캐너(Philips GEMINI PET/CT의 특성 평가)

  • Kim, Jin-Su;Lee, Jae-Sung;Lee, Byeong-Il;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.4
    • /
    • pp.318-324
    • /
    • 2004
  • Purpose: Philips GEMINI is a newly introduced whole-body GSO PET/CT scanner. In this study, performance of the scanner including spatial resolution, sensitivity, scatter fraction, noise equivalent count ratio (NECR) was measured utilizing NEMA NU2-2001 standard protocol and compared with performance of LSO, BGO crystal scanner. Methods: GEMINI is composed of the Philips ALLEGRO PET and MX8000 D multi-slice CT scanners. The PET scanner has 28 detector segments which have an array of 29 by 22 GSO crystals ($4{\times}6{\times}20$ mm), covering axial FOV of 18 cm. PET data to measure spatial resolution, sensitivity, scatter fraction, and NECR were acquired in 3D mode according to the NEMA NU2 protocols (coincidence window: 8 ns, energy window: $409[\sim}664$ keV). For the measurement of spatial resolution, images were reconstructed with FBP using ramp filter and an iterative reconstruction algorithm, 3D RAMLA. Data for sensitivity measurement were acquired using NEMA sensitivity phantom filled with F-18 solution and surrounded by $1{\sim}5$ aluminum sleeves after we confirmed that dead time loss did not exceed 1%. To measure NECR and scatter fraction, 1110 MBq of F-18 solution was injected into a NEMA scatter phantom with a length of 70 cm and dynamic scan with 20-min frame duration was acquired for 7 half-lives. Oblique sinograms were collapsed into transaxial slices using single slice rebinning method, and true to background (scatter+random) ratio for each slice and frame was estimated. Scatter fraction was determined by averaging the true to background ratio of last 3 frames in which the dead time loss was below 1%. Results: Transverse and axial resolutions at 1cm radius were (1) 5.3 and 6.5 mm (FBP), (2) 5.1 and 5.9 mm (3D RAMLA). Transverse radial, transverse tangential, and axial resolution at 10 cm were (1) 5.7, 5.7, and 7.0 mm (FBP), (2) 5.4, 5.4, and 6.4 mm (3D RAMLA). Attenuation free values of sensitivity were 3,620 counts/sec/MBq at the center of transaxial FOV and 4,324 counts/sec/MBq at 10 cm offset from the center. Scatter fraction was 40.6%, and peak true count rate and NECR were 88.9 kcps @ 12.9 kBq/mL and 34.3 kcps @ 8.84 kBq/mL. These characteristics are better than that of ECAT EXACT PET scanner with BGO crystal. Conclusion: The results of this field test demonstrate high resolution, sensitivity and count rate performance of the 3D PET/CT scanner with GSO crystal. The data provided here will be useful for the comparative study with other 3D PET/CT scanners using BGO or LSO crystals.