• Title/Summary/Keyword: Protective solution

Search Result 293, Processing Time 0.026 seconds

Heuristic Search in Overcurrent Protection Coordination of Power Distribution Systems (경험적 탐색에 의한 배전계통 보호기기 정정협조)

  • 이승재;박영문;이정원
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.40 no.2
    • /
    • pp.135-143
    • /
    • 1991
  • The setting problem of protective devices in power distribution systems is a combinatorial search problem involving a lot of trial & errors to search for a proper solution which has a great impact for the system reliability. This paper discusses the nature of the problem and proposes a scheme to prune the decision tree achieving the efficient search for a setting solution by applying heuristic rules which utilize pattern informations of backup and primary devices. Its effectiveness is demonstrated through many tests on real systems.

  • PDF

Preparation of Spherical Nickel Powder by Hydrothemal Process (수열합성법을 이용한 구형 니켈분말 제조)

  • 원창환;배장호;이종현;김병범
    • Journal of Powder Materials
    • /
    • v.11 no.3
    • /
    • pp.217-223
    • /
    • 2004
  • Submicron nickel powders were prepared from aqueous solution under hydrothermal condition. The experimental conditions including the types of protective agents, concentration of the solution and the pH were studied in detail. Starting concentration of nickel ion is a dominant factor affecting particle size. It was shown that the subsequent addition of Poly Vinyl Pyrrolidone(PVP) and Sodium Dodecyle Sulfate(SDS) can help to disperse the nickel powder. X-ray diffraction and SEM were employed to characterize the products.

Study on the Characteristics of Crevice Corrosion Prevention of SS 400 in Marine Environment (해양환경 중에서 SS400강재의 간극부식방지 특성에 관한 연구)

  • 임우조;정기철;구영필;윤병두
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2001.05a
    • /
    • pp.152-157
    • /
    • 2001
  • This paper was studied on the characteristics of crevice corrosion prevention of SS 400 in marine environment. In NaCl solution, polarization behavior under the crevice corrosion was investigated. And Weight loss rate of SS 400 applied cathodic protection and non cathodic protection was measured according to the NaCl concentration. The main results obtained are as follows : The weight loss rate of Al-alloy galvanic anode was increased as the concentration of NaCl solution increased by 3.5% but the concentration increased over 3.5%, that of Al-alloy galvanic anode become decreased. The protective potential of SS 400 used Al-alloy galvanic anode becomes more cathodic polarization with increasing concentration of NaCl solution. Effects of oxygen on the weight loss rate of Al-alloy sacrificial anode for cathodic protection as the concentration of 3.5% NaCl solution become sensitive than that of 0% NaCl solution.

  • PDF

Corrosion Resistance of Galvanized Steel by Treating Modified Si Organic/Inorganic Hybrid Coating Solution (Si 변성 유/무기 하이브리드 코팅액에 의한 아연도금강판의 내식특성)

  • Seo, Hyun-Soo;Moon, Hee-Joon;Kim, Jung-Ryang;Kim, Jong-Soon;Ahn, Seok-Hwan;Moon, Chang-Kwon;Nam, Ki-Woo
    • Journal of Ocean Engineering and Technology
    • /
    • v.25 no.1
    • /
    • pp.32-38
    • /
    • 2011
  • Galvanized steel has gone through a chemical process to keep it from corroding. The steel gets coated in layers of zinc because rust will not attack this protective metal. For countless outdoor, marine, or industrial applications, galvanized steel is an essential fabrication component. The reduction of the corrosion rate of zinc is an important topic. In the past, a very popular way to reduce the corrosion rate of zinc was to use chemical conversion layers based on $Cr^{+6}$. However, a significant problem that has arisen is that the use of chromium salts is now restricted because of environmental protection legislation. Therefore, it is very important to develop new zinc surface treatments that are environmentally friendly to improve the corrosion resistance of zinc and adhesion with a final organic protective layer. In this study, a Urethane solution (only Urethane 20 wt.%; S-700) and an organic/inorganic solution with Si (Si polysilicate 10 wt.% + Urethane 10 wt.%; LRO-317) are used. Based on the salt spray test of 72 h, S-700 and LRO-317 had a superior effect for the corrosion resistance on EGI and HDGI, respectively.

Enhanced Myocardial Protection by Addition of Creatine Phosphate to the St. Thomas Hospital Cardioplegic Solution -Studies in the rat - (St. Thomas Hospital 심정지액에 Creatine Phosphate 를 첨가한 후 심근 보호 효과)

  • 최순호
    • Journal of Chest Surgery
    • /
    • v.22 no.4
    • /
    • pp.580-588
    • /
    • 1989
  • The potential for enhancing myocardial protection by adding high-energy phosphate to cardioplegic solutions [St. Thomas Hospital solution] was investigated in a rat heart model of cardiopulmonary bypass and ischemic arrest. Creatine phosphate was evaluated as an additive to the St. Thomas Hospital cardioplegic solution. Creatine phosphate 10.0 mmol/L as the optimal concentration which improved recovery of aortic flow and cardiac output after a 30 minute period of normothermic [37oC] ischemic arrest. In comparing mechanical function in both groups the mean postischemic recoveries of aortic flow, cardiac output, stroke volume and stroke work [expressed as a percentage of its preischemic control] were significantly greater in STH-CP group than in CP- free control group. In addition to improving function and decreasing CK release, CP reduced reperfusion arrhythmias significantly decreasing the time between cross-clamp removal and return to regular rhythm from 81.8 * 13.9 [sec] in CP-free group to 35.9 * 6.8 [sec] in CP group [P< 0.05] so, exogenous CP exerts potent protective and antiarrhythmic effects when added to the St. Thomas Hospital cardioplegic solution. However, the mechanism of action remains to be elucidated.

  • PDF

Evaluation of Iron Nickel Oxide Nanopowder as Corrosion Inhibitor: Effect of Metallic Cations on Carbon Steel in Aqueous NaCl

  • Chaudhry, A.U.;Mittal, Vikas;Mishra, Brajendra
    • Corrosion Science and Technology
    • /
    • v.15 no.1
    • /
    • pp.13-17
    • /
    • 2016
  • The aim of this study was to evaluate the use of iron-nickel oxide ($Fe_2O_3$.NiO) nanopowder (FeNi) as an anti-corrosion pigment for a different application. The corrosion protection ability and the mechanism involved was determined using aqueous solution of FeNi prepared in a corrosive solution containing 3.5 wt.% NaCl. Anti-corrosion abilities of aqueous solution were determined using electrochemical impedance spectroscopy (EIS) on line pipe steel (API 5L X-80). The protection mechanism involved the adsorption of metallic cations on the steel surface forming a protective film. Analysis of EIS spectra revealed that corrosion inhibition occurred at low concentration, whereas higher concentration of aqueous solution produced induction behavior.

The Study of Protective Solution and People in Technology Outflow about SMEs (중소기업 기술유출 및 기술인력 방지제도에 관한 연구)

  • Chung, Jason
    • International Commerce and Information Review
    • /
    • v.17 no.3
    • /
    • pp.133-152
    • /
    • 2015
  • Cause of the technology leakage and trade secrets can be leaked to the lack of infrastructure, lack of coping skills of SMEs. In addition, small businesses can avoid technology outflow and re-experience the same half of the damage, even when the external leak developed after the fact and does not demonstrate such technology leakage time for the technology and situation which did not take any action, security, infrastructure investments difficult, work-related knowledge, lack of security, trade secret protection dedicated staff, inadequate legal and institutional measures have been identified as such complaints to date. For subcontracting, etc. mid-sized transactions, hinder the growth of SMEs, SME cross-technology leakage to the increase in unfair practices, including useful, and this has been accompanied by growth-based business-to-business it weakened.

  • PDF

Clothing Management in the Rural Household - In Sihung-Si Gyonggi-Do Province - (농촌가정의 의생활 관리 실태 조사연구 - 경기도 시흥시를 대상으로 -)

  • 염희경;최정화
    • Korean Journal of Rural Living Science
    • /
    • v.6 no.1
    • /
    • pp.1-10
    • /
    • 1995
  • To lead rural clothing management in the rural household, we assessed in terms of the wearing of pesticide protective clothing and care methods of contaminated clothing, consumer consciousness, the discard method of clothing et al. in rural areas of Gyonggi-Do by sampling 122 households. The results are as following ; 1. The behavior for laundering management didn't appropriate in view of certification of label about laundry method, frequency of laundry and quantitative use of detergent. Also family's cooperative attitude wasn't insufficient. 2. Reasons of dissatisfaction about retained clothing were decreased in order of discoloration, shrink or breakage after laundry, breakage of seam or cloth, unlabel, allergy from cloth. The solution of trouble was acted passively. 3. Reasons of hoarding of clothing were high because of change on size, fashion, and low because of wornout. Still-wearable garments were discarded in proportion of one to one. 4. The ratio of putting on the fatigue cap which the Once of Rural Development has propagated was under 10 percent. 5. Protective clothes against agricultural chemicals had not been prepared and contaminated clothing was often washed with regular family wash.

  • PDF

An experimental study on the myocardial protection effect of the steroid mixed cardioplegic solution (Steroid를 첨가한 Cardioplegic solution의 심근보호효과에 관한 실험적 연구)

  • 유시원
    • Journal of Chest Surgery
    • /
    • v.17 no.4
    • /
    • pp.565-573
    • /
    • 1984
  • The increasing use of cardioplegic solution for the reduction of ischemic tissue injury requires that all cardioplegic solution be carefully assessed for any protective or damaging properties. This study describes functional assessment of the efficiency of steroid in cardioplegic solution by using a Langendorffs perfusion model. Isolated rat heart were subject to a 2 minute period of coronary infusion with the steroid mixed cold cardioplegic solution immediately before and also at the midpoint of a 60 minutes period of hypothermic [10\ulcorner\ulcorner] ischemic arrest. The result of this study were as follows: 1.Spontaneous heart beat after ischemic arrest occurred 14 second later Langendorffs reperfusion in the steroid mixed Young & GIK group and 16 second later in the control group. [Young & GIK without steroid] A good recovery state of spontaneous heart beat was shown in both groups. 2.The percentage of recoveries of heart rate during the 30 minute after postischemic Langendorffs reperfusion was; at first 5 minute 106.3\ulcorner.7% [P<0.05] in the steroid mixed Young & GIK group. This percentage of recovery of steroid mixed Young & GIK group was significantly greater than the control group during the first 5 minute course. 3.The percentage of recovery of coronary flow during the 30 minute after postischemic Langendorffs reperfusion was; at first 5 minute 101\ulcorner.2% in the steroid mixed Young & GI K group. This percentage of recovery of the steroid mixed Young & GIK group was not significantly than the control group during the first 5 minute.

  • PDF

Corrosion Characteristics of hot rolled and thermo-mechanically treated steel rebar in concrete pore solution (콘크리트 기공 솔루션에서의 열간 압연 및 열 기계 처리 철근의 부식 특성)

  • Lee, Han-Seung;Singh, Jitendra Kumar
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.05a
    • /
    • pp.202-203
    • /
    • 2018
  • Chemistry and microstructure of steel reinforcement bars play an important role to control the corrosion in concrete environments. In present study, we have chosen two different microstructure of steel rebars produced from companies and assessed their corrosion characteristics in simulated concrete pore (SCP) solution with prolonged exposure periods. Hot rolled steel rebar showed more corrosion resistance compare to thermo-mechanically treated (TMT) one. The growth of passive is greater in hot rolled (A) than TMT (B) due to orientation of microstructure. TMT steel rebar exhibit distorted microstructure with many micro cells which enhances the galvanic coupling and induce the deterioration while on the other hand hot rolled rebars exhibit fine grain boundary which responsible in growth of uniform, adherent and protective passive film resultant improved impedance was observed.

  • PDF