• Title/Summary/Keyword: Protective means

Search Result 135, Processing Time 0.033 seconds

Development of an Impedance Locus Model for a Protective Relay Dynamic Test with a Digital Simulator

  • Kim, Soo-Nam;Lee, Myoung-Soo;Lee, Jae-Gyu;Rhee, Sang-Bong;Kim, Kyu-Ho
    • Journal of Electrical Engineering and Technology
    • /
    • v.6 no.2
    • /
    • pp.167-173
    • /
    • 2011
  • This paper presents a method for the development of the impedance locus to test the dynamic characteristics of protective relays. Specifically, using the proposed method, the impedance locus can comprise three impedance points, and the speed of impedance trajectory can be adjusted by frequency deviation. This paper is divided into two main sections. The first section deals with the configuration of impedance locus with voltage magnitude, total impedance magnitude, and impedance angle. The second section discusses the control of the locus speed with the means of the deviation between two frequencies. The proposed method is applied to two machine equivalent systems with offline simulation (i.e., PSCAD) and real-time simulation (i.e., real-time simulation environment) to demonstrate its effectiveness.

Motor Protection and Control with Digital Protective Relays (디지털 보호 계전기를 이용한 모터 보호 및 제어)

  • 이성환;안인석
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.178-178
    • /
    • 2000
  • In this paper, intelligent methods using digital protection relay in power management and control system is developed in order to protect power systems by means of timely fault detection during operation and control at starting for induction motor which have various load environments and capacities in power systems. The digital protective relay was designed with DSP CPU(TMS320C31) to Protect and measure more quickly and precisely. The test result on the basis of KEMCl120 and IEC60255, show that the operation time error of the digital motor protection relay is improved within $\pm$5%. Also, we can control motors at starting according to starting types with simple method as programmable sequence editor. So we can improve the demerits of high cost and much manhour for rework.

  • PDF

Investigation of Influence of Pulse-periodical Laser Radiation Power on Stability of Liquid-metal Contacts between Powder Particles during Selective Laser Sintering

  • Beljavin, K.E.;Minko, D.V.;Bykov, R.P.;Kuznechik, O.O.
    • Proceedings of the Korean Powder Metallurgy Institute Conference
    • /
    • 2006.09a
    • /
    • pp.518-519
    • /
    • 2006
  • A connection between pulse-periodical laser radiation power and stability of liquid-metal contacts between powder particles during selective laser sintering (SLS) is determined based on analysis solving the problem of stability of liquid column in the gravity and capillary forces field. On the grounds of obtained relationships the optimization of pulse-periodical laser radiation power and SLS-process duration is realized, that allows to produce voluminous powder porous materials with pre-determined physical and mechanical properties and surface geometry. Results of metallographic investigations of powder porous materials of titanium powder produced with technological regimes calculated by means of obtained relationships are given in the work

  • PDF

Comparison of Thermal Protective Performance Test of Firefighter's Protective Clothing against Convection and radiation heat sources (대류와 복사 열원에 대한 특수방화복의 열보호 성능시험 비교)

  • Kim, Hae-Hyoung;Yoo, Seung-Joon;Park, Pyoung-Kyu;Kim, Young-Soo;Hong, Seung-Tae
    • Fire Science and Engineering
    • /
    • v.31 no.2
    • /
    • pp.17-23
    • /
    • 2017
  • The test methods using convection (flame) and radiation heat sources were compared to evaluate the thermal protective performance of the firefighter's protective clothing. In particular, the influence of the outer shell, mid-layer, and lining constituting the firefighter's protective clothing on the thermal protective performance was compared for convection and radiation heat sources. Tests for the thermal protective performance were carried out according to KS K ISO 9151 (convection), KS K ISO 6942 (radiation), and KS K ISO 17492 (convection and radiation). When tested under the same incident heat flux conditions ($80kW/m^2$), the heat transfer index ($t_{12}$ and $t_{24}$) for the radiation heat source was higher than that for the convection heat source. This means that radiation has a lesser effect than convection. For the convection heat source, the lining had the greatest effect on the thermal protective performance, followed by the mid-layer and the outer shell. On the other hand, for the radiation heat source, the effect on the thermal protective performance was great in the order of lining, outer shell, and mid-layer. Convection and radiation have fundamentally different mechanisms of heat transfer, and different heat sources can lead to different thermal protective performance results depending on the material composition. Therefore, to evaluate the thermal protective performance of the firefighter's protective clothing, it is important to test not only the convection heat source, but also the radiation heat source.

Isolation and Characterization of Vaccine Candidate Genes Including CSP and MSP1 in Plasmodium yoelii

  • Kim, Seon-Hee;Bae, Young-An;Seoh, Ju-Young;Yang, Hyun-Jong
    • Parasites, Hosts and Diseases
    • /
    • v.55 no.3
    • /
    • pp.255-267
    • /
    • 2017
  • Malaria is an infectious disease affecting humans, which is transmitted by the bite of Anopheles mosquitoes harboring sporozoites of parasitic protozoans belonging to the genus Plasmodium. Despite past achievements to control the protozoan disease, malaria still remains a significant health threat up to now. In this study, we cloned and characterized the full-unit Plasmodium yoelii genes encoding merozoite surface protein 1 (MSP1), circumsporozoite protein (CSP), and Duffy-binding protein (DBP), each of which can be applied for investigations to obtain potent protective vaccines in the rodent malaria model, due to their specific expression patterns during the parasite life cycle. Recombinant fragments corresponding to the middle and C-terminal regions of PyMSP1 and PyCSP, respectively, displayed strong reactivity against P. yoelii-infected mice sera. Specific native antigens invoking strong humoral immune response during the primary and secondary infections of P. yoelii were also abundantly detected in experimental ICR mice. The low or negligible parasitemia observed in the secondary infected mice was likely to result from the neutralizing action of the protective antibodies. Identification of these antigenic proteins might provide the necessary information and means to characterize additional vaccine candidate antigens, selected solely on their ability to produce the protective antibodies.

ISO/TC107 - Metallic and other inorganic coatings: Involvement, Activities and Standardization

  • Gyawali, Gobinda
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2017.05a
    • /
    • pp.85-85
    • /
    • 2017
  • ISO (International Organization for Standardization) is an independent, non-governmental international organization with a membership of 163 national standards bodies (NSB). The ISO standards are developed and processed within the technical committees (TC) or their subcommittees (SC) dealing with the different subject matters. The first technical committee, ISO/TC1, deals with screw threads and was created back in 1947. While, more recently, TC 309 was created to standardize organizational governance. The ISO technical committee in the field of metallic coatings was created in 1962 with the title ISO/TC107- Metallic and other inorganic coatings. This ISO/TC107 technical committee is dealing with the standardization of the characteristics of protective and decorative metallic coatings applied by electrolysis, fusion, vacuum or chemical means, mechanical deposition and ion plating. similarly, it also covers the standardization of the characteristics of protective and decorative non-metallic coatings (excluding paints and other organic coatings) on metal surface applied by electrolysis, fusion, vacuum or chemical means. Scope is further extended to the Standardization of the preparation of the substrates prior to the deposition of metallic and inorganic coatings. There are a total of 144 existing ISO standards published by this technical committee and has 19 participating countries (P-members) and 24 observing countries (O-members). Korean Agency for Technology and Standards (KATS), being the secretariat of ISO/TC107, is constantly supporting this technical committee for the development of standards and related activities.

  • PDF

Effects of Natural Extracts on the Radiation-induced Pink Mutations in Tradescantia Stamen Hair Cells

  • Kim, Jin-Kyu;Kim, Yeon-Ku;Lee, Byoung-Hun;Lee, Young-Il;Shin, Hae-Shick
    • Nuclear Engineering and Technology
    • /
    • v.31 no.5
    • /
    • pp.522-528
    • /
    • 1999
  • The effect of a water-soluble extract from natural materials on radiation-induced mutations was studied by means of TSH assay in Tradescantia 4430 stamen hair cells. Inflorescence cuttings, with or without pretreatments of natural extracts for 3 hours, were exposed to 1 Gy of gamma ray. Comparisons were made on the basis of pooled data during the peak interval between the mean pink mutation frequencies of the experimental groups. Pretreatments of FB or FB-I resulted in about two-fold increases of the pink mutation frequencies, compared to those of the control group. Synergism between certain fractions and radiation was a possible cause of the increased DNA damage. FB and FB-I had a radiosensitizing effects on the pink mutations in Tradescantia 4430 stamen hair cells (p<0.001). On the other hand, the extract PP in a proper concentration significantly reduced the pink mutation frequencies (p<0.05). The result means that PP has a protective effect on the radiation-induced cell damage.

  • PDF

A Study on the Improvement of the Subway Protective Guards System (지하철보안관제도의 활성화 방안에 관한 연구)

  • Lee, Sol-Ji;Lee, Ju-Lak
    • Korean Security Journal
    • /
    • no.49
    • /
    • pp.133-154
    • /
    • 2016
  • The Seoul subway system has one of the highest transport shares in the city of Seoul. A high number of passengers means that a high level of crimes of all kinds occur on the city's subway system. As such, Seoul Metro, created the Subway Protective Guards System in 2009, in an effort to enhance safety on the subway. But this innovative new system did not resolve problems. In fact, many citizens came to question the effectiveness of the new system, as it did not yield tangible results. This study seeks to deduce the problems and activation strategy of the Subway Protective Guards System. An in-depth study was conducted by interviewing subway protective guards who were squad leaders with five or more years of relevant work experience. Semi-structured interview analysis was utilized to evaluate their responses. Specifically, their responses were deduced to identify the strengths and weaknesses internal to the system and the opportunities and threats posed by the environment external to the system. This study presents measures to improve the system based on the aforementioned analysis. Measures for improvement focused on the following areas: the adoption of an education system in response to terror; recruitment and the possibility of becoming a permanent employee; obtaining partial judicial powers; improvement of work environment; and intensifying the promotion of the system.

  • PDF

Comparison of lymphocyte DNA damage levels and total antioxidant capacity in Korean and American diet

  • Lee, Min Young;Kim, Hyun A;Kang, Myung Hee
    • Nutrition Research and Practice
    • /
    • v.11 no.1
    • /
    • pp.33-42
    • /
    • 2017
  • BACKGROUND/OBJECTIVE: This study aims to measure the in vitro antioxidant capacity of Korean diet (KD) with American diet (AD) as a control group and to examine the ex vivo DNA damage reduction effect on human lymphocytes. MATERIALS/METHODS: The KD applied in this study is the standard one-week meals for Koreans (2,000 kcal/day) suggested by 2010 Dietary Reference Intakes for Koreans. The AD, which is the control group, is a one-week menu (2,000 kcal/day) that consists of foods that Americans would commonly take in according to the National Health and Nutrition Examination Survey. The antioxidant capacity of each menu was measured by means of the total phenolic assay and 3 in vitro antioxidant activity assays (2,2-diphenyl-1-picrylhydrazyl (DPPH) radical scavenging activity, trolox equivalent antioxidant capacity (TEAC), Oxygen radical absorbance capacity ($ORAC_{ROO{\cdot}}$)), while the extent of ex vivo lymphocyte DNA damage was measured by means of the comet assay. RESULTS: When measured by means of TEAC assay, the in vitro antioxidant capacity of the KD of the day was higher than that of the AD (P < 0.05) while there was no significant difference in total phenolic contents and DPPH and ORAC assays. The ex vivo lymphocyte DNA damage protective effect of the KD was significantly higher than that of the AD (P < 0.01). As for the one-week menu combining the menus for 7 days, the total phenolic assay (P < 0.05) and in vitro antioxidant capacity (P < 0.001, DPPH; P < 0.01, TEAC) of the KD menu were significantly higher than those of the AD menu. Likewise, the ex vivo DNA damage reduction rate of the Korean seven-day menu was significantly higher than that of the American menu (P < 0.01). CONCLUSION: This study demonstrates that the high antioxidant capacity and DNA damage protective effect of KD, which consists generally of various plant foods, are higher than those of typical AD.

Experimental Study on Temporary Overvoltage Characteristics of MOV Based Surge Protective Devices (MOV 기반 서지보호기의 일시과전압 특성에 대한 실험적 연구)

  • Shim, Hae-Sup;Jeon, Tae-Hyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.1
    • /
    • pp.71-77
    • /
    • 2010
  • Protection against lightning surge is an essential part of almost any electrical and electronic equipment today. Metal Oxide Varistor(MOV) is the single most important component in the overwhelming majority of the Surge Protective Devices(SPD) designated to provide such protection. In this paperr various types of MOV based SPD are inspected and experiments are carried out on the side effects of the low Measured Limiting Voltage(MLV) characteristics. Experiment results show that a lower MLV could cause a higher Temporary Overvoltage(TOV)-induced SPD failure rate in the field, and SPD are more likely to be victims rather than protectors in a TOV scenario. This means that from a safety perspective, the SPD should be specified with higher TOV withstand capability(UT) and faster SPD disconnector.