• 제목/요약/키워드: Protective function test

검색결과 73건 처리시간 0.033초

태양광발전용 인버터 보호기능시험 성능평가 (Performance Evaluation with Protective Function test of Inverter for Solar Power Generation)

  • 윤용호
    • 전기학회논문지
    • /
    • 제67권11호
    • /
    • pp.1570-1575
    • /
    • 2018
  • The increased penetration of PV is impacting on grid operation and in particular the voltage within the local grid can be significantly influenced by the various PV systems. The increased penetration of PV is impacting on grid operation and in particular the voltage within the local grid can be significantly influenced by the various PV systems. This paper describes domestic technical standard of Photovoltaic(PV) PCS(Power Conditioning Systems)- Characteristics of the utility interface. Especially protective function test items of 1) Output overvoltage protection test, 2) Output undervoltage protection test, 3) Frequency rise protection test, 4) Frequency fall protection test, 5) System voltage's momentary interruptions, 6) System voltage distortion capability test. Therefore in this paper protective function test item of facilities evaluation detailed standards for new renewable energy, small, medium and large photovoltaic inverter standard is studied and analyzed and finally full tested by PV inverter performance function.

도시철도 직류 비접지 급전계통에서의 선택 지락보호시스템의 성능평가 (An Evaluation of Selective Grounding Fault Protective Relaying Technique Performance on the Ungrounded DC Traction Power Supply System)

  • 정호성;김주욱;신승권;김형철;안태풍;윤준석
    • 전기학회논문지
    • /
    • 제61권12호
    • /
    • pp.1964-1969
    • /
    • 2012
  • This paper presents to verify the selective grounding fault protective relaying technique for the ungrounded DC traction power supply system. This system selectively blocks fault section when grounding fault occurred. In order to perform this verification, field test facilities have been installed on Oesam substation and Worldcup-Stadium substation, and field test process has been suggested. Also, selective grounding fault protective relaying components and rail voltage reduction device have been tested with the various trial examinations. In order to compare and evaluate performance of the selective grounding fault protective relaying function, field test system was modeled and the system fault simulation results were compared and evaluated with the field test result. Performance of selective grounding fault protective relaying function was evaluated with the above-mentioned process, and the fact that the system recognizes fault section irrespective of insulation between rail and ground and fault resistance from grounding fault.

Development and Evaluation of Protective Clothing for Rose Farmers

  • Chae, Hyeseon;Kim, Sungchul;Oh, Youngsoon;Lee, Kyungsook;Kim, Hyocher;Park, Soonjee
    • 한국의류학회지
    • /
    • 제40권3호
    • /
    • pp.427-436
    • /
    • 2016
  • Protective clothing developed for rose flower farmers has been evaluated to improve the working conditions. The requirements of rose farmers were first identified to design protective clothing for farmers working with thorny plants. A fit test was conducted to assess the thermal comfort and protective function against thorn pricking to compare and evaluate the usability of developed experimental clothing with existing working clothes. Based on the survey results of rose farmers' requirements, protective clothing was designed in the form of an apron (which was the most preferred after gloves) with a pattern designed for the production of experimental clothing. For the developed protective clothing, the strap and buckle closure method was selected to open the back of the body as much as possible; in addition, sleeves were made in the attachable form of a half-sleeve to protect the arms from the thorns. The fit test of the developed protective clothing and existing working clothes revealed the temperature and humidity inside the developed protective clothing to be significantly different in the back compared to existing work clothes. In addition to thermal sensations, the subjective humidity sensations were statistically significant different in the developed protective clothing compared to existing work clothes. The subjective protective function for thorn pricking was also found to be satisfactory.

광두근(廣豆根) 분획물이 중대뇌동맥폐쇄(中大腦動脈閉鎖)에 의한 뇌허혈손상에 미치는 효과(I) - 행동평가를 기준으로 (Effect of Sophora Subprostrata Fractions on Focal Ischemic Brain Damage Induced by Middle Cerebral Artery Occlusion in Rats(I))

  • 최문석;김연섭
    • 동의생리병리학회지
    • /
    • 제19권3호
    • /
    • pp.760-764
    • /
    • 2005
  • This research was performed to investigate protective effect of Sophora Subprostrata fractions against focal ischemic brain damage after middle cerebral artery(MCA) occlusion. Rats were divided into six groups: MCA-occluded group(Control); each administered groups with Sophora Subprostrata total phase(Total), Sophora Subprostrata Aqueous phase (Aqueous), Sophora Subprostrata BuOH phase(BuOH), and Sophora Subprostrata Alkaloid phase(Alkaloid) after MCA-occlusion; sham-operated group(Sham). The right MCA was occluded by A poly-L-lysine coated 4-0 nylon suture thread through the internal carotid artery permanently. Sophora Subprostrata and fractions were administered orally(5mg/ml) for 7 days after MCA-occlusion. The behavior of ischemic rats were examined at 24 hours, 3, 5 and 7 days after MCA-occlusion from the views of 4 different aspects: posture & balance tests(4 subtests), reflex tests(6 subtests), muscle-tone tests(3 subtests), and foot-fault test. The results showed that 1) in muscle tone test, Sophora Subprostrata total phase only increased reduced muscle tone function from 3 to 7 days, 2) in reflex test, Sophora Subprostrata total and Aqueous phase increased fast recovery from 24 hours and 3 days, 3) in posture & balance test, Sophora Subprostrata total and Aqueous phase increased fast recovery from 24 hours, and Sophora Subprostrata BuOH and Alkaloid phase increased posture & balance function from 3 days, but 4) in motor function test, Sophora Subprostrata did not show effective recovery compared with control group. In conclusion, Sophora Subprostrata has protective effects against brain damage at the early stage of focal cerebral ischemia. Sophora Subprostrata total and Aqueous phase produced more pronounced protective effect against focal ischemic brain damage.

가정용 연료전지시스템 계통연계형 전력변환장치의 보호기능 성능평가에 관한 연구 (A Study on the Protective Function Performance Evaluation of Grid-Connected Power Conditioning System for Residential Fuel Cell System)

  • 이정운;서원석;김영규
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 춘계학술대회 논문집
    • /
    • pp.341-344
    • /
    • 2009
  • In this paper, protective function evaluation was conducted to determine the performance and safety of a power conditioning system(PCS) for 1kW residential fuel cell system. It is essential to have a power quality, grid-connection and safety of PCS. Even though it is under 500ms by KGS-A410 standard, it is shown a rapid response time of 25ms from input under-voltage test. In terms of output over/under-voltage test, it is shown 29.15 and 79.4ms. Especially using anti-islanding test, it is shown all times under 100ms for combination cases of real and reactive power. We confirmed a rapid response characteristics and safety of PCS. The results of this evaluation are being used to develop a new test protocols of PCS.

  • PDF

Evaluation of Corrosion Protection for Epoxy and Urethane Coating by EIS under Various Cyclic Corrosion Tests

  • Hyun, Jonghun;Shon, Minyoung
    • Corrosion Science and Technology
    • /
    • 제10권3호
    • /
    • pp.95-100
    • /
    • 2011
  • Protective coatings play an important role in the protection of metallic structures against corrosive environment. The main function of anticorrosive coating is to prevent the materials from corrosive agents, such as water, oxygen and ions. In the study, the corrosion protection properties of urethane and epoxy coating systems were evaluated using EIS methods exposed to the corrosion acceleration test such as Norsok M501, Prohesion and hygrothermal cyclic test. AFM analysis of the coating systems was carried out to monitor the change of roughness of coatings. Urethane coating system was more stable than the epoxy coating under given cyclic conditions. Water uptake into the urethane coatings was less than that into the epoxy coating. The urethane coating system showed better corrosion protection than epoxy coating system based on the changes of the impedance modulus at low frequency region with exposure time. Consequently, the corrosion protection properties of the epoxy and urethane coatings was well correspond with their surface roughness changes and water uptakes.

비닐하우스용 작업복의 자외선 차단 성능과 착용감 연구 (UV ray protective function and wear sensation of garment for plastichouse worker)

  • 최정화;백윤정
    • 한국농촌생활과학회지
    • /
    • 제6권1호
    • /
    • pp.25-30
    • /
    • 1995
  • This study was designed to obtain the basic data developing the UV ray protective garments for the plastichouse workers. Two subjects were volunteered for 1hr. wear test in plastic house, and the ensembles was composed of one of three kinds blouse (UV blocking blouse, polyester/cotton 47/53 blouse, and polyester blouse), shorts, sleeveless undershirts, pants and socks. The measurements were rectal temperature, skin temperature, microclimate inside clothing, subjective sensation, and the colour difference of UV sensor. The results were as follows: 1. Microclimate especially, temperature inside clothing of polyester blouse was the highest among the garments. And UV-proof polyester blouse showed the lower mean skin temperature and microclimate than others. Showing the highest sweat volume. 2. No significant difference on UV ray blocking function among 3 kinds of garment was shown. 3. We could conform that in spring for the plastic house wぉw s garment low thermal insulating value and wide covering area were more important factors than UV blocking function of fabric.

  • PDF

사지에서 유리 조직 이식술에 의한 감각 기능 회복 (Sensory Function Recovery by Free Tissue Transfer in the Extremities)

  • 이준모;김권일;황병연
    • Archives of Reconstructive Microsurgery
    • /
    • 제14권1호
    • /
    • pp.14-17
    • /
    • 2005
  • Purpose: Authors have performed free tissue transplantation in the upper and lower extremities with sensory flaps and evaluated the sensory function recovery. Materials and methods: Between 1992 through 2004, sensory free flap articles published in the journal of the Korean microsurgical society, were reviewed and recovery of sensory function was assessed by static two-point discrimination test. Results: Static two point discrimination test showed average 6.7 mm in the thumb, average 12 mm in the hand and 7 cm of the dorsalis pedis flap, 20.5 mm of the lateral arm flap and over 8 cm of the forearm flap in the foot. Conclusion: Sensory flaps provide the protective and useful coverage in the upper and lower extremities and have benefit for activities for daily life in free tissue transferred patients.

  • PDF

Function Layer가 적용된 AC-PDP에서 지속방전으로 재형성 된 MgO 나노 입자의 음극선 분광 분석

  • 이경애;최준호;손창길;최은하
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2009년도 제38회 동계학술대회 초록집
    • /
    • pp.419-419
    • /
    • 2010
  • 최근 AC-PDP의 효율향상을 위해 MgO Protective Layer 위에 별도의 기능막(Functional Layer)을 적용하고 있으며 기능막의 재료로는 MgO 나노 입자를 사용하고 있다. 그러나 장시간 구동시 AC-PDP Panel 내에서 Plasma 방전에 의하여 MgO Protective Layer와 기능막이 방전 공간에 형성 된 이온에 의해 Sputtering 또는 재 증착 될 수 있다. 본 실험에서는 기능막이 적용된 AC-PDP Test Panel을 제작하여 장시간 구동 후 MgO Protective Layer와 기능막인 MgO 나노 입자의 재형성된 형태를 주사 전자 현미경(Scanning Electron Microscope)을 통해 Surface Profile 및 구조의 변화를 분석하고, 또한 음극선 분광 분석(Cathodoluminascence)을 통하여 방전 영역과 비방전 영역의 delay time, 방전전압 및 효율 등의 전기 광학적 특성과의 관계를 분석하고자 한다.

  • PDF

콘크리트 보호코팅재의 자기치유 기능의 시각화 (Visualization of Self-Healing Function of Protective Coating for Concrete)

  • 김동민;최주영;진승원;남경남;박형주;정찬문
    • 융합정보논문지
    • /
    • 제9권10호
    • /
    • pp.87-93
    • /
    • 2019
  • 치유 물질인 아마인유에 형광 물질을 소량 혼합한 혼합물을 코어 성분으로 하여 마이크로캡슐을 제조하였다. 이 마이크로캡슐을 코팅재 조성물에 균일하게 분산시켜 모르타르 표면에 도포함으로써 지기치유 보호코팅재를 제작하였다. 이 코팅재에 약 $100{\mu}m$ 폭의 스크래치 또는 균열 손상을 발생시킨 후 자외선을 조사하면서 관찰한 결과, 캡슐 함량이 증가할수록 형광 발광의 범위가 증가하였고, 20wt% 이상의 캡슐을 함유한 코팅재에서는 손상 부위가 치유물질로 거의 채워진 모습을 나타내었다. 물흡수도 시험 결과 20wt% 이상의 캡슐을 함유한 코팅재는 약 85%의 치유효율을 보였다. 손상 부위에서 나타나는 형광은 3m의 거리에서도 용이하게 식별되었다. 본 연구결과는 콘크리트 보호를 위한 마이크로캡슐형 자기치유 코팅재의 치유기능을 육안으로 용이하게 확인하는데 도움을 줄 것으로 기대된다.