• Title/Summary/Keyword: Protective facilities

검색결과 167건 처리시간 0.03초

반도체 소자를 이용한 테슬라 코일의 설계 및 제작 (A Study on Design and Implementation of the Tesla Coil using Semiconductor Device)

  • 김영선;김동진;이기식
    • 전기학회논문지
    • /
    • 제65권9호
    • /
    • pp.1571-1576
    • /
    • 2016
  • A Tesla coil is an electrical resonant transformer circuit invented by Nikola Tesla in 1891. It is used to produce high-voltage, low-current, high frequency alternating-current electricity. Tesla coil can generate a long streamer with several million volts of electricity as a high voltage device. It is basically consists of a voltage transformer, high voltage capacitor, spark gap, primary coil, secondary coil and toroid. It is difficult to appear in the output size of the streamer is controlled by the spark gap. The general decision method of the length of streamer is to display the electric output in accordance with the design specifications in initial development plan. Design specifications and the electric output is determined by the application of facilities. In this paper the spark gap is replaced with periodic switching semiconductor device to control output voltage easily in order to apply overvoltage protective circuit due to a secondary coil and a performance test. In these days, their main use is for entertainment and educational displays of the museum, although small coils are still used as leak detectors for high vacuum systems.

전통민속마을 소방방재 기본구상 - 아산 외암민속마을을 중심으로 - (A Study on the Basic Ideas for Fire Fighting Prevention System in Traditional Folk Village - Focused on Oeam Folk Village in Asan -)

  • 이정수;이왕기;오규형;신교영;권흥순
    • 건축역사연구
    • /
    • 제19권1호
    • /
    • pp.71-90
    • /
    • 2010
  • This research has set up the fire protection and early suppression plan for Asan Oeam folk village which is composed of traditional wooden building instinct or complex. The results of this study are as follows. 1. The traditional wooden buildings require attentive considerations about the fire property of the Waga and the straw roofed house. Especially, as the straw roofed house has property that the transfer and development of the fire is fast. Therefore we studied on the transferring possibilities of the fire dangerous instinct through measuring the distance from of the eaves edge and trees in neighboring house. 2. This research proposes the tools for the priority protective building through consideration of fire risk and cultural priority because the fire prevention for all is impossible at the same time. 3. The most important thing is preserve the cultural identities of traditional folk village in establishing the fire hydrant and fire prevention facilities. Traditional folk village landscape should be considered.

해양환경 중에서 Glass Flake 라이닝 강재의 부식과 캐비테이션 침식 방지에 관한 연구 (Study on the Corrosion and Cavitation Erosion Control of Glass Flake Lining for Mild Steel in Marine Environment)

  • 임우조;김성훈
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2000년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.359-365
    • /
    • 2000
  • Port facilities and marine structures used in marine environment were encountered to corrosion damages because of the influence of $Cl^-$. Generally, to protect these accidents, mainly applied anti-corrosion paint and epoxy coating. But it was still remained erosion-corrosion damage such as impingement erosion, cavitation erosion, deposit attack. There was needs to develope the new coating materials to protective those corrosion damages. This paper, polyester glass flake, vinylester glass flake lining and epoxy coating for SS were investigated electrochemical tests and cavitation erosion test for corrosion behaviour under sea water. The main results obtained are as follows, 1) Surface of epoxy coating appear erosion pin hole but surface of polyester glass flake and vinylester glass flake lining do not appear erosion pin hole after impingement-cavitation erosion test in sea water. 2) Weight loss of polyester glass flake and vinylester glass flake lining do not occur after impingement-cavitation erosion test in sea water. 3) Corrosion current density of polyester glass flake lining less drained than epoxy coating and substrate under corrosion potential.. 4) Corrosion current density of vinylester glass flake lining with three coating less drained than that of polyester glass flake lining with two coating.

  • PDF

도시에서 하이브리드 LID 침투관 설치에 따른 침투량 향상 (Improvement of Infiltration by Applying Hybrid Low Impact Development (LID) Infiltration Pipes in an Urban Area)

  • 한경수;박용순
    • Ecology and Resilient Infrastructure
    • /
    • 제3권2호
    • /
    • pp.126-129
    • /
    • 2016
  • 도시화로 인해 불투수 면적이 증가하면서 지하 침투량이 감소하고 강우 유출량이 증가하여 도시 침수 발생 가능성이 커지고 지하수 고갈 문제를 발생시키고 있다. 본 연구에서는 가로수 주위에 수분 및 영양을 공급할 수 있는 신개념 특수 가로수 보호판의 설치가 도시 내 침투량 개선에 미치는 효과를 평가하고, 시설의 배치에 따른 침투량 변화를 조사하였다. 침투관이 설치된 신개념 가로수 보호판은 토양으로는 빗물 침투량을 증가시키고 지면 위 수위 상승을 억제하였다. 따라서 개발된 신개념 가로수 보호판은 도시 도로변에서 저영향개발 (LID) 시설로서 효과적으로 적용될 수 있을 것으로 판단되었다.

진단영역 넓은 선속 X선 에너지에 대한 차폐물질의 투과 특성 (Broad Beam Transmission Properties of some Shielding Materials for Use in Diagnostic Radiology)

  • 정희원;김정민;임송수
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제27권4호
    • /
    • pp.23-29
    • /
    • 2004
  • 진단영역에서 사용하는 넓은 선속 X선 에너지에 대한 차폐물질의 투과 특성을 Archer의 수학적 모델을 적용하여 나타내었다. 인버터 방식의 고전압발생장치를 사용하는 X선 발생장치를 사용하여 관전압 60 kVp부터 140 kVp까지의 범위에서 납, 철, 콘크리트, 유리등의 차폐체의 투과 특성을 나타내었다. 이러한 인버터 방식의 고전압발생장치를 사용하는 진단영방사선발생장치의 관전압별 투과도는 진단방사선발생장치를 사용하는 작업공간에서의 차폐 설계 시 차폐물질의 종류와 두께의 설정에 도움이 될 것이다.

  • PDF

Effect of Surface Contaminants Remained on the Blasted Surface on Epoxy Coating Performance and Corrosion Resistance

  • Baek, Kwang Ki;Park, Chung Seo;Kim, Ki Hong;Chung, Mong Kyu;Park, Jin Hwan
    • Corrosion Science and Technology
    • /
    • 제5권1호
    • /
    • pp.27-32
    • /
    • 2006
  • One of the critical issues in the coating specification is the allowable limit of surface contaminant(s) - such as soluble salt(s), grit dust, and rust - after grit blasting. Yet, there is no universally accepted data supporting the relationship between the long-term coating performance and the amount of various surface contaminants allowed after grit blasting. In this study, it was attempted to prepare epoxy coatings applied on grit-blasted steel substrate dosed with controlled amount of surface contaminants - such as soluble salt(s), grit dust, and rust. Then, coating samples were subjected to 4,200 hours of cyclic test(NORSOK M-501), which were then evaluated in terms of resistance to rust creepage, blistering, chalking, rusting, cracking and adhesion strength. Additional investigations on the possible damage at the paint/steel interface were carried out using an Electrochemical Impedance Spectroscopy(EIS) and observations of under-film-corrosion. Test results suggested that the current industrial specifications were well matched with the allowable degree of rust, whereas the allowable amount of soluble salt and grit dust after grit blasting showed a certain deviation from the specifications currently employed for fabrication of marine vessels and offshore facilities.

직류철도 급전계통의 안전성 향상을 위한 차단기 동작 최적 설정의 실험적 고찰 (An Experimental Study on Operation Setting Optimization of Circuit Breaker for Improving Safety on DC Railroad Feeder System)

  • 이재봉;정노건;김재문
    • 전기학회논문지
    • /
    • 제65권3호
    • /
    • pp.526-531
    • /
    • 2016
  • This paper presents an experimental study on the optimal settings for the selected DC fault relay (50F) to improve the operating performance for the high-speed circuit breaker on DC feeding system which ensure safety within rolling stock maintenance depot. In this study, current supplied to overhead contact wire was calculated on 1 ms interval to analyze the correction values of DC fault selective relay for the operation of current supply cutout. Particularly, standards for the accurate detection of accidents between an electric railway vehicle and the electric power facilities are shown by investigating the optimal correction values for detection of fault current, and the results indicated that it takes about 213 ms for the DC fault selective relay(50F) to fully open. In the future, the correction values of DC fault selective relay suggested in this paper will be used as the reference values of protective relay for the safe operation of DC electric railroad system such as urban railway.

최적화 기법이 적용된 전력계통 안정화 시스템 개발 (Development of power system stabilization program using optimization method)

  • 안창한;백영식
    • 전기학회논문지
    • /
    • 제64권3호
    • /
    • pp.370-374
    • /
    • 2015
  • Various protective equiptments are used for the power system control and protection. Numerous facilities are monitored at the same time in real time and introduction of optimization method and analysis of the method are required for generation control and facility management considering the demand fluctuations. However, the existing system analysis programs are difficult to link with the other sw and there are some problems with user convenience. To solve these problems the present conditions of the system are figured out in real time and the equipment insert method was estimated by optimization method, and the system that showed the system analysis program is developed. PSS/E has been used as system anlysis program for stabilizing system development which applied the optimization. method and Python language is applied in order to link the input and output values with the DB automatically. Lastly, DLL of matlab has been made included in C++ for solving the objective function using opmization method.By linking this to DB, power flow was calculated in PSS/E and the result was represented by Intouch screen.

주요 정보통신기반시설의 평가컨설팅 방법론에 대한 연구 (A Study on the Evaluation Consulting Methodology of Important Information Communication Base Facility)

  • 이영로;조재완
    • 디지털융복합연구
    • /
    • 제5권1호
    • /
    • pp.55-68
    • /
    • 2007
  • It soaks but 2001 July information communication base step law enforcement and the Enforcement Ordinance are published to follow, in order to support the establishment of evaluation and protective measure in order the vulnerability analysis against the facility of the agency which manages an important information communication base hour opinion to designate information protection specialty enterprise. As information protection specialty enterprise being revealed evacuation laboratory back 12 enterprises from information communication department become designation as the consulting enterprise and they do an enterprise activity actively. It follows in diffusion of the IT and information reconciliation level the other side where our country belongs in the world-wide first group, the research against the disfunction plan of preparation comparison the fact that law it is come negligently all actuality. The network as it will give management coat fatal effect even at obstacle occurrence hour of instant for of case and IT facility of the cyber transactions which leads, in the future there to be to corporate management, there is a possibility the stable civil official of information Facilities for communications very seeing in the portion which is important. Present condition and important propulsion contents of information communication base step law enforcement after, against a vulnerability analysis of information protection relation field and evaluation consulting methodological application situation to sleep it researches from the dissertation which it sees consequently and it does.

  • PDF

누전차단기 폭로에 따른 동작 특성 및 재료 분석 (The Material Analyses and the Behavior Characteristics according to RCD Discloser)

  • 한운기;김향곤;길형준;이기연;최충석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 C
    • /
    • pp.2019-2021
    • /
    • 2005
  • This paper describes the cut off time and the current characteristics of virgin RCDs and deteriorated ones in the seashore. The RCDs(Residual Current Protective Devices) are used for protecting the human body from electrical shock and for preventing facility accidents. According to the Korean standards, the RCDs are installed in panel boards. When RCDs are installed outside, they must be enclosed inside waterproof cases. In the case that RCOs are employed at temporary power sites and electrical facilities on the road, they are exposed to the external environment. As a result, the RCDs deteriorated in the seashore for 3 months showed high failure rate, while the virgin RCDs all complied with Korean Standard. Considering that the RCDs are used under exposed condition outside, the reliance of RCDs must be ensured by modifying the related regulations and codes and by developing Improved models advanced in their performance.

  • PDF