• Title/Summary/Keyword: Protective device

Search Result 272, Processing Time 0.031 seconds

Operational characteristics analysis of protective relay for utility application of HTS power cable (초전도 전력케이블의 계통 적용을 위한 보호계전기의 동작특성 분석)

  • Kim, Jae-Ho;Kim, Jin-Geun;Sim, Ki-Deok;Cho, Jeon-Wook;Yoon, Jae-Young;Lee, Seung-Ryul;Park, Min-Won;Yu, In-Keun
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.57-58
    • /
    • 2008
  • Recently, several kinds of superconductivity applications are implemented and evaluated in the utility power networks. The protection system for HTS(High Temperature Superconducting) power devices safe operation has not been established yet. For the protection of the HTS apparatus, a better understanding of the quench properties against fault current and appropriate protection devices are required. In this study, an algorithm of protection system is developed with respect to HTS power cable. The protection system of HTS power cable was analyzed in the simulated power system. Results obtained from simulation will provide much more decisive data in order to design a certain superconducting power device, and can give a good information for the installation in power system.

  • PDF

The study on the characteristics of transient recovery voltage of electromagnetic contactor (전자기 접촉기의 과도회복전압 특성에 대한 연구)

  • Kim, Geun-Yong;Ryu, Jae-Nam
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.834-835
    • /
    • 2008
  • 전자기 접촉기(electromagnetic contactor)는 교류 또는 직류 저압의 전로(電路)에 사용되는 부하개폐기의 한 종류로 전자석 코일(electromagnet coil)의 여자(勵磁)에 의하여 주 접촉자를 개폐시키는 기기이다. 일반적으로 전자기 접촉기는 단락전류를 차단하도록 설계되어 있지는 않다. 그러므로 설치 시 적절한 단락 보호가 이루어져야 하며, 반드시 접촉기의 일부분일 필요는 없다. 차단기와 퓨즈 등을 단락보호장치(SCPD, Short-Circuit Protective Device)로 많이 사용한다. 전자기 접촉기는 특히 고빈도 개폐를 목적으로 사용되는 개폐기로, 농형모터(squirrel-cage motors)의 시동, 운전 중의 정지, 플러깅(plugging, 모터가 운전하고 있는 중에 모터의 1차측 접속을 역으로 바꿔서 모터를 급격히 정지시키거나 역 회전시키는 것) 및 인칭(inching, 모터를 짧은 기간 동안 1회 또는 반복 여자해서 피동기구를 조금 이동시키는 것)에 많이 쓰인다. 이러한 기기의 개폐특성을 평가하기 위한 부하는 과도회복 전압의 진동 주파수(oscillatory frequency)와 진폭율 ${\gamma}$를 얻을 수 있도록 조정되어야 한다. 본 논문에서는 고빈도 개폐능력을 갖고 있는 전자기 접촉기의 과도회복 전압 특성과 그 특성을 얻기 위한 부하 회로의 조정방법에 대해 고찰하였다.

  • PDF

A Study on the ICCP Control and Monitoring System for Ship (선박용 ICCP 제어 감시 시스템에 관한 연구)

  • 이지영;오진석
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.28 no.4
    • /
    • pp.667-674
    • /
    • 2004
  • This thesis is about the Impressed Current Cathodic Protection (ICCP) control and monitoring system. which brings protection against the corrosion of the ship's hull in the sea environments. The ICCP system is composed of a power supply. anode. reference electrode and controller. AC sources from the ship's generator are converted to DC sources in terms of power supply, and a protection current is sent to ship's hull though anode. The controller fully senses whether or not the detected potential is within a range of protection of ship's hull and then it is automatically controlled to increase or decrease the amount of protective current to be sent to the anode. The monitoring system with RS 232/485 communication is also studied in order to check the normal state of the system at a long period. because an operator does not always watch over this system and thus the system cannot operate well because of his or her negligent management. Since the vessel always navigates in the sea. an characteristics experiment of the ICCP system is conducted by introducing various corrosive environmental factors such as velocity, resistivity, dissolved oxygen, PH, temperature and contamination degree. These results must be referred to when the ICCP system is set up. In short. the ICCP is a multi-system for use on ships and on land structures because it includes a safety device. It is suggested that this system can accomodate a ship's automation and will be very useful.

The Self-Fault Determination and Restoration Methodology based on the Ethernet Communication (이더넷 통신기반의 자율적 고장 판단 및 복구 방법론 연구)

  • Ko, Yun-Seok;Lee, Seo-Han;Choi, Hyun-Chul;Shin, Jae-Hyun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.9
    • /
    • pp.1674-1680
    • /
    • 2009
  • This paper proposes an autonomous fault determination, fault zone isolation and fault restoration strategy based on the ethernet communication as a new attempt to solve the problem the of the existing central control method. In proposed method, The FRTU(Feeder Remote Terminal Unit)s on the feeder determines autonomously where the faulted zone is by exchanging the voltage and current information with neighbor FRTUs based on the network communication, and then separates the faulted zone in an nil-voltage status to make the protective device to reclose successively. In particular, the minimization of outage time and relational load balancing is archived by each interconnection switch which determines autonomously the load zone to be allocated among those zones after the sound outage zones was separated individually. Finally, to show effectiveness of the proposed fault restoration strategy, the several fault cases are simulated for the test distribution system, and the load balancing index of the proposed solution is compared with all of feasible solutions.

Effects of distribution fault current limiting apparatus and emerging applications (배전급 전류제한 장치 효과 분석 및 도입 방안)

  • Lee, B.W.;Park, K.B.;Kim, H.M.;Oh, I.S.
    • Proceedings of the KIEE Conference
    • /
    • 2006.07c
    • /
    • pp.1540-1541
    • /
    • 2006
  • For limitation and interruption of short circuit currents from low voltage to extra high voltage applications, the electrical equipment including fuses and circuit breakers, are widely used today. But in order to anticipate increasing needs for effective and competitive device for limiting the growing fault current in electrical power systems, fault current limitation technologies and fault current limitation devices are widely introduced and investigated in these days. Fault current limiters are emerging electric equipment which is under development using various methods including superconducting fault current limiter, solid state fault current limiter, arc driving fault current limiters. And these various methods have some advantages and disadvantages to take into considerations In order to commercialize fault current limiters in the electrical networks, a lot of discussions should be given on the point that fault current limiting methods, need for fault current limiters, coordination with existing protective system, and field experience before commercialization. In this paper, recent trends of fault current limiting technologies will be reviewed and the key issues of superconducting fault current limiters will be dealt with. And finally, future applications of superconducting fault current limiters would be discussed.

  • PDF

Study on Improvement of Overcurernt Relay (OCR)'s Operation Due to Application of Superconducting Fault Current Limiter (SFCL) in Power Distribution System with a Dispersed Generation (분산전원이 도입된 배전계통에 초전도한류기 적용에 따른 과전류계전기 동작향상 연구)

  • Lim, Seung-Taek;Lim, Sung-Hun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.2
    • /
    • pp.300-304
    • /
    • 2017
  • Due to the introduction of various types of dispersed generations (DGs) with larger capacity in a power distribution system, the short-circuit current is expected to be increased, which more requires for the effective fault current limiting methods. As one of the promising countermeasures, the superconducting fault current limiter (SFCL) has been noticed. However, the decreased fault current by SFCL affects the operation of the overcurrent relay (OCR), representative protective device in a power distribution system. In this paper, the operation of the overcurrent relay due to the application of a SFCL in a power distribution system with DG linked by its bus line was analysed through the short-circuit tests. To analyze the effect of the SFCL application in a power distribution system with DG, the experimental simulated circuits were designed and the short-circuit tests for the power distributed system assembled with the DG, the OCR and the SFCL were carried out. Through the analysis on the short-circuit tests, the application of the SFCL in a power distribution system with DG could be confirmed to be contributed to the operational improvement of overcurrent relay.

A Study on Job Satisfaction, Working Environment and Turnover Intention of Dental Technicians in Daegu Area (대구지역 치과기공사의 직무만족 및 작업환경과 이직의도에 관한 연구)

  • Park, Hong-Ryurn;Moon, Seon-Jeong
    • The Korean Journal of Health Service Management
    • /
    • v.6 no.4
    • /
    • pp.191-204
    • /
    • 2012
  • The purpose of this study was to provide basic data necessary for improvement by closely examining factors of having influence upon dental technicians' turnover. Questionnaire survey was conducted of 204 dental technicians who work at dental hospitals, clinics and dental laboratory rooms in Daegu area. The following conclusions were obtained. The satisfaction with job was high in job position in more than co-representative, in the whole and other task, and in less than 9 hours as for working hours. In the satisfaction with working environment, dissatisfaction was high in women, in the working career with 7~9 years, in chief level as for the job position in charge, in being responsible for porcelain in case of the duty field, and in more than 10 people as for the number of employees. The higher satisfaction with job satisfaction and working environment led to the lower turnover intention. Turnover intention was low in case of having ventilation fan & dust collector desk and in case of being well ventilated inside the workshop. As the above results, it is considered to be necessary for arranging institutional device of protecting dental technicians' health and reducing turnover through improving working environment such as forming comfortable environment of using the dust-collecting facilities and the ventilation facilities, wearing suitable individual protective gear and arranging the rest space.

Respiratory Protection for LASER Users

  • Lee, Sang Joon;Chung, Phil-Sang;Chung, Sang Yong;Woo, Seung Hoon
    • Medical Lasers
    • /
    • v.8 no.2
    • /
    • pp.43-49
    • /
    • 2019
  • The plume produced by vaporizing tissue with a laser contains a variety of contaminants called laser-generated air pollutants (LGACs). LGACs consist of a mixture of toxic gas components, biomicroparticles, dead and living cells, and viruses. Toxic odors and thick smoke from surgical incisions and the coagulation of tissues can irritate eyes and airways, as well as cause bronchial and pulmonary congestion. Because of the potential risk of the smoke, it is advisable to appropriately remove it from the surgical site. We recommend using a smoke evacuator to remove the smoke. Suction nozzles should be placed as close as possible to the surgical site in a range of 2 cm or less. In-line filters should be used between the inlet and outlet of the surgical site. All air filtration devices should be capable of removing particles below 0.1 microns in size. The filter pack should be handled according to infection control procedures in the operating room. The laser mask can be an auxiliary protective device if it is properly worn. Some smoke inhaled under the nose wrap or over the side of the mask will not be filtered. As in electrosurgical operations, a suitable mask should be worn while smoke is present.

A Study on the Countermeasure Algorithm for Power System Disturbance in Large Scale Fuel Cell Generation System (대용량 연료전지발전시스템의 계통외란방지알고리즘에 관한 연구)

  • Kim, Gi-Young;Oh, Yong-Taek;Kim, Byung-Ki;Kang, Min-Kwan;Rho, Dae-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.8
    • /
    • pp.5550-5558
    • /
    • 2015
  • Recently, fuel cell with high energy efficiency and low CO2 emission is energetically interconnected with power system. Especially, FCGS(Fuel Cell Generation System) which usually operates at high temperature, is being developed and installed in the form of large scale system. However, it is reported that power system disturbances related to surge, harmonic and EMI have caused several problems such as malfunction of protection device and damage of control device in the large scale FCGS. In order to solve these problems, this paper presents a modeling of operation characteristics of FCGS by PSCAD/EMTDC, ETAP, P-SIM software. And also, this paper proposes countermeasure algorithms to prevent power system disturbances. From the simulation results, it is confirmed that the proposed algorithm is useful method for the stable operation of large scale FCGS.

Electrical Fire Disaster Prevention Device of Double Protection using a High Precision Current Sensor in Low Voltage Distribution System (고정밀 전류센서를 이용한 저압배전계통 이중 보호용 전기화재 방재장치)

  • Kwak, Dong-Kurl;Jung, Do-Young
    • Fire Science and Engineering
    • /
    • v.23 no.3
    • /
    • pp.40-47
    • /
    • 2009
  • Nowadays the diversity and large-capacity of electric appliances are strong effect on electrical fires augment in an alarming way. But, as the inactive response characteristics of the existing RCD (Residual Current protective Device) used on low voltage power distribution system, so control of overload and electric short circuit faults, major causes of electrical fires, are not enough. Therefore, this paper is confirmed the unreliability of the existing RCD by electrical fault simulator and is proposed a Electrical Fire Disaster Prevention Device (EFDPD) by using a high precision current sensor (namely, reed switch) for the prevention of electrical disasters in low voltage power distribution system caused by overload or electric short circuit faults. The sensitive reed switch in the proposed EFDPD exactly detects the increased magnetic flux with the overload or the short current caused by a number of electrical faults, and the following, the EFDPD has double protection function which operates self circuit breaker or rapidly cuts off the existing RCD. The proposed EFDPD is confirmed the excellent characteristics in response velocity and accuracy in comparison with the conventional circuit breaker through various operation performance analysis. The proposed EFDPD can also prevent electrical disaster, like as electrical fires, which resulted from the malfunction and inactive response characteristics of the existing RCD.