An automatic excitation characteristics measurement system for the protective relaying current transformer(CT) with accuracy of about 1 % has been developed. The system can be used up to 2 kV and 10 A at power frequency. The developed system can calculate the voltage and current at knee points of $30^{\circ}$ and $45^{\circ}$ tangents in accordance with IEEE standard by the interpolation in log scale. The excitation curve of the CT is plotted in auto-scale simultaneously with measuring rms voltage and current at the secondary of the CT.
Park, Kyungwon;Kim, Min Jee;Shin, Chul Ho;Kim, Young-Geun
Proceedings of the KIEE Conference
/
2015.07a
/
pp.215-216
/
2015
The application of fault current limiter(FCL) reduces power system fault current for circuit breaker to operate properly due to reduced fault current. Also FCL reduces through fault current to the power system equipments. But FCL has changed power system parameters for short time, before application the magnitude of register, triggering current and protective relay coordination have to be studied. In this paper we will examine protective relay coordination with FCL. And propose better solution to assist improving of power system operation through the application of FCL.
The Transactions of the Korean Institute of Electrical Engineers A
/
v.52
no.2
/
pp.99-106
/
2003
In this paper, an intelligent fault location and diagnosis system is proposed. The proposed system identifies the fault location in two-step procedure. The first step identifies candidates of fault location using an fault distance calculation using an iterative method. The second step is diagnosis the actual fault location in the candidates by comparing the current waveform patterns with the expected operation of the protective devices and considering the interrupted load after the operation protective device. The simulations results in the case study demonstrates a good performance of the proposed fault location and diagnosis system.
The setting of protective relays, which is critical to the system security, requires a huge volume of data and a lot of repetitive calculations. Since an effective design of a database is essential. The relay setting database must accommodate a variety of protective devices. Also its information can be viewed and updated with easy by humans and by computer programs. This paper describes several existing database designs for power system protection, their advantages and disadvantages. Also this paper develops an effective database for power system protection with their advantages.
The Transactions of The Korean Institute of Electrical Engineers
/
v.61
no.8
/
pp.1107-1114
/
2012
In this paper, we propose protective coordination and automatic setting method using agents for distribution system with loop. The proposed protection scheme adopts an agent technology assuming communication among protection agents and auto-switch agents. Having exchanged fault-related information with each other, protection agents and auto-switch agents perform the primary and backup protection and fault section isolation, respectively. this proposed scheme using agents for distribution system with loop is implemented by matlab. Because of the various configuration of distribution system, It's difficult to find cooperative agents for each agent. This paper develops a program to automatically set the cooperative route for the agents.
Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
/
v.19
no.2
/
pp.77-86
/
2005
The DC protection and control device for the feeding system of a Light Rail Transit(LRT) system is developed. For the development, the short circuit characteristics in the system are analyzed. As a result a protection algorithm for the DC fault selective relay (50F) is newly proposed, and principles of the DC fault selective relay, Line Test Device (LTD), DC Over Current Relay (DC OCR) are introduced From the development, the specifications and codes used to be unclear have become clarified and summarized. Moreover, the methods to examine the protective characteristics and Electromagnetic Compatibility (EMC) are established Finally, the performance and the effectiveness of the developed protective relay have been verified with the test based on IEC. For the reliability of the system, the relay has been installed and is being operated at the test track of the LRT system at Gyeong-San.
The Transactions of the Korean Institute of Electrical Engineers P
/
v.62
no.4
/
pp.210-215
/
2013
This paper analyze the bus voltage sags in the power distribution system with a small scale cogeneration system when the superconducting fault current limiter was introduced. Among the solutions to decrease the short-circuit current considering the locations of the small scale cogeneration system, the superconducting fault current limiter (SFCL) has been announced as one of the promising methods to reduce the fault current because the installation of the small scale cogeneration system which increases the short-circuit current. According to the application locations of the small scale cogeneration system in a power distribution system, it has caused the variations of voltage sag and duration which depends on the change of the short-circuit current, which can make the operation of the protective device deviate from its original set value when the fault occurs. To investigate the voltage sag when a SFCL was applied into a power distribution system where the small scale cogeneration system was introduced into various locations, the SFCL, small scale cogeneration system, and power system are modeled using PSCAD/EMTDC. In this paper, the effects on voltage sags are assessed when the SFCL is installed in power distribution system with various locations of the small scale cogeneration system.
Objectives : Polygalae Radix (PR) from Polygalae tenuifolia (Polygalaceae) has been clinically used as a sedative, anti-inflammatory, and anti-bacterial agent. To extend pharmacological effects of PR in the central nervous system (CNS) on the basis of its CNS protective effect, the present study was conducted to identify the effect of PR, whether it shows the neuroprotective action against excitatory neurotoxicity. Methods : To identify the protective effect of PR to excitatory neuro-toxic agent, the present study was focused on the PR effect on cell death, that was caused by applying NMDA to nerve cell, elevation of $(Ca^{2+})_i$, releasement of glutamate, and ROS generation. Result : 1. PR methanol extract, at the concentration range of 0.05 to 5 g/ml, significantly inhibited NMDA (1 mM)-induced neuronal cell death as well as MK-801 (non competitive NMDA antagonist). 2. PR methanol extract $(0.5\;{\mu}g/ml)$ inhibited NMDA (1 mM)-induced elevation of cytosolic calcium concentration $[Ca^{2+}]_i$. NMDA application in the presence of MK-801 $(10\;{\mu}M)$ failed to produce the increase of $[Ca^{2+}]_i$ through all the measurement time. 3. PR methanol extract $(0.5\;{\mu}g/ml)$ inhibited the NMDA-induced elevation of glutamate release. Also, MK-801 showed similar protective effects. 4. PR methanol extract $(0.5\;{\mu}g/ml)$ inhibited the NMDA-induced elevation of ROS generation. Also, MK-801 showed similar protective effects. Conclusion : The present study provides the availability of PR to exert its protective effect on the neuronal cell death in various neurodegenerative pathophysiological conditions.
Journal of the Korea Institute of Military Science and Technology
/
v.23
no.3
/
pp.294-301
/
2020
Man-In-Simulant Test(MIST) provides a test method to evaluate chemical protective equipments such as protective garments, gloves, footwear and gas mask. The MIST chamber is built to control concentration of chemical vapor that has a activity space for two persons. Non-toxic methyl-salicylate(MeS) is used to simulate chemical agent vapor. We carried out to measure inward leakage MeS vapors by using passive adsorbent dosimeter(PAD) which are placed on the skin at specific locations of the body while man is activity according to the standard procedure in MIST chamber. But more time is required for PADs and there is concern of contamination in PADs by recovering after experiment. Therefore detector for measuring in real time is necessary. In order to analyze in real time the contamination of the personal protective equipment inside the chemical environment, we have developed a wireless real-time gas detector. The detector consists of 8 gas-sensors and 1 control-board. The control-board includes a CPU for processing a signal, a power supply unit for biasing the sensor and Bluetooth-chipset for transmission of signals to external PC. All signals from gas-sensors are converted into digital signals simultaneously in the control-board. These digital signals are stored in external PC via Bluetooth wireless communication. The experiment is performed by using protective equipment worn on manikin. The detector is mounted inside protective equipment which is capable of providing a real-time monitoring inward leakage MeS vapor. Developed detector is demonstrated the feasibility as real-time detector for MIST.
Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
/
v.24
no.1
/
pp.56-62
/
2010
This paper describes the analysis of loop impedance characteristics by impedance alteration of protective conductors and operating characteristics of electric leakage circuit breaker by each earth systems(TT system, TN-S system and TN-C system) in IEC 60364. As a result, loop Impedance was affected by resistance & inductance. The current& voltage characteristics about earth system were identified that the TN-S system was high fault current & low touch voltage. TN-C system was almost same the TN-S system but TT system was low fault current & high touch voltage.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.