• Title/Summary/Keyword: Protective System

Search Result 1,336, Processing Time 0.025 seconds

Fault Current Calculation and Coordination by IEC Standards (IEC 표준에 의한 고장전류 계산과 보호협조)

  • Son, Seok-Geum
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.12
    • /
    • pp.6-12
    • /
    • 2014
  • The safety and reliability of the power system short-circuit current, the short-circuit current depends on the failure to obtain the objective is to quickly eliminate the breaking capacity of the circuit-breaker selection of the cable, the insulation of electrical equipment and protective relay an important factor in determining the level correction and protective relay selection scheme to be meaningful. Standards used in the domestic circuit breaker is applied to the production of IEC standard, but the American National Standards (ANSI / IEEE) by NEMA specification of the fault current calculations and the application of the asymmetric coefficient Korea. Therefore, in this paper, the IEC 60909 standard IEC breaker fault current calculation method and the method for selection of system configurations reviewed and protection system for reviewing the configuration of various protective relays appropriate correction and the correction value is main protection, back-up protection the equipment so that the period of protection relay coordination to minimize accidents and accident protection to minimize interruptions proposed for cooperation.

Analysis on the Protective Coordination on Neutral Line of Main Transformer in Power Distribution Substation with Superconducting Fault Current Limiter (MTR 중성점 접지에 초전도 전류제한기 적용시 지락과전류계전기 동작 분석)

  • Kim, Jin-Seok;Lim, Sung-Hun;Moon, Jong-Fil;Kim, Jae-Chul;Hyun, Ok-Bae
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.11
    • /
    • pp.2089-2094
    • /
    • 2009
  • The fault current has increased due to growth of distributed generations for the large power demand in power distribution system. To solve some problem such as excess of the circuit breaker's cut-off ratings, the superconducting fault current limiter(SFCL) has been progressed. However, the operational characteristics of the relay is changed by SFCL. Therefore, the proper impedance for the SFCL should be selected to keep protective coordination with the SFCL when SFCL is introduced on the neutral line of main transformer in distribution system. In this paper, the proper normal conducting resistance was suggested to solve the problem in case of the protection coordination with SFCL.

A Study on the Overcurrent Relay Coordination in Power Systems (전력계통에서의 과전류계전기 보호협조에 관한 연구)

  • Choi, Hong-Kyoo;Kim, Kyung-Chul;Oh, Jung-Suk;Kim, Byung-Chul
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.351-358
    • /
    • 2004
  • When fault occur in power systems, the protective relay plays a roles of protecting power system according to its setting values. There, it is very important that the protective relay have high selectivity performance in power system by correct setting the relays. This paper analyzed protect device protect cooperation or Transient stability and apply to Overcurrent relay in the real power system operation environment by using EDSA Program.

  • PDF

Graphical Presentation on Operation Principle of Protective Relay According to Winding Type and Vector Group in Transformer (전력용 변압기에서 권선방식과 벡터그룹에 따른 보호계전기 동작원리의 그래픽 표현)

  • Lee, Jong-Beom
    • Proceedings of the KIEE Conference
    • /
    • 1999.07c
    • /
    • pp.1410-1412
    • /
    • 1999
  • Protective relay for transformer operates in general by comparing with the differential current and the restraint current. These kinds of currents are changed on magnitude and phasor during the fault according to winding type and vector group. This paper presents the differential and restraint currents and operational principle of differential protective relay for two-winding and three-winding transformer with graphical model. It is developed using MATLAB for an educational purpose on engineer related in power system and protection in university and power utility including large factory.

  • PDF

Depressive stress related symptoms and associated factors among marriage immigrant women: Focused on risk factors and protective factors (결혼이주여성의 우울 스트레스 증상과 그 영향 요인: 위험 요인과 보호 요인을 중심으로)

  • Cho, Wonsup;Yoo, Seunghyun
    • Korean Journal of Health Education and Promotion
    • /
    • v.34 no.1
    • /
    • pp.47-65
    • /
    • 2017
  • Objectives: This paper aims to identify depressive or stress related symptoms and its associated risk and protective factors among marriage immigrant women in Korea. Methods: The study participants were 490 immigrant wives from '2012 Survey of Foreign Residents in Korea'. The participants completed self-administered questionnaires on socio-demographics, health status, family members' related factors, and other environmental factors. Results: Difficulties on child nursing, finance, family conflict, and experience of physical or verbal violence were significant risk variables to the depressive stress related symptoms. Family life satisfaction, discussion about troubles with Koreans, healthy status, social trust, and discussion about troubles with people from home country were the significant protective variables to mental health. However economic activities were not protective factors but risk factors. Conclusions: Mental Health promotion programs for marriage immigrant women and their family members need to consider the family and community related protective mental health factors and develop supportive system with pre-existing programs and policy modification.

Enhanced Electrochemical Properties of Dye-sensitized Solar Cells Using Flexible Stainless Steel Mesh Electrodes with Ti Protective Layer (Ti 보호층이 형성된 스테인레스 스틸 메쉬 전극을 이용한 염료감응형 태양전지의 전기 화학적 특성 개선)

  • Jung, Haeng-Yun;Ki, Hyun-Chul;Gu, Hal-Bon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.28 no.3
    • /
    • pp.180-184
    • /
    • 2015
  • Stainless steel (SS) mesh was used to fabricate photoelectrode for flexible dye-seisitzed solar cells (DSSCs) in order to evaluate them as replacements for more expensive transparent conductive oxide(TCO). We fabricated the DSSCs with new type of photoelectrode, which consisted of flexible SS mesh coated with 100 nm thickness titanium (Ti) protective layer deposited using electron-beam deposition system. SS mesh DSSCs with protective layer showed higher efficiency than those without a protective layer. The best cell property in the present study showed the open circuit voltage (Voc) of 0.608 V, short-circuit current density (Jsc) of $5.73mA\;cm^{-2}$, fill factor (FF) of 65.13%, and efficiency (${\eta}$) of 2.44%. Compared with SS mesh based on DSSCs (1.66%), solar conversion of SS mesh based on DSSCs with protective layer improved about 47%.

Protective effect of Samultang and its four herbal plants against reactive oxygen species in vitro and cellular system

  • Nam, Mi Na;Lee, Ah Young;Sin, Seung Mi;Goo, Young-Min;Cho, Eun Ju
    • Korean Journal of Agricultural Science
    • /
    • v.46 no.3
    • /
    • pp.427-437
    • /
    • 2019
  • Oxidative stress and overproduction of free radicals have been reported to be a major pathological hallmark of neurodegenerative diseases. Samultang has been known as a beneficial agent to treat liver disease and cardiovascular diseases. However, the anti-oxidant activities and neuro-protective effects of Samultang against oxidative stress still have not been evaluated yet. The aim of the present study was to investigate the anti-oxidant and protective effects of Samultang and its four herbal plants, Paeonia lactiflora (PL), Ligusticum striatum (LS), Rehmannia glutinosa (RG), and Angelica gigas (AG), in vitro system and in SH-SY5Y neuronal cells. The extracts of Samultang strongly increased the radical scavenging activities of 1,1-diphenyl-2-picrylhydrazyl (DPPH), hydroxyl radical (${\cdot}OH$), and nitric oxide (NO) in a concentration-dependent manner. Furthermore, we investigated the protective effects of Samultang on cellular damage against oxidative stress induced by hydrogen peroxide ($H_2O_2$) in SH-SY5Y cells. Treatment with Samultang alleviated the oxidative stress from $H_2O_2$ by increasing the cell viability and decreasing the intracellular reactive oxygen species levels. Based on these results, we further investigated the radical scavenging effects of PL, LS, RG, and AG. In our results, PL had the highest DPPH, ${\cdot}OH$, and NO radical scavenging activities. Thus, PL has a crucial role in Samultang, which has anti-oxidative and neuro-protective effects. The present research suggests that Samultang and PL have protective roles against oxidative stress from $H_2O_2$-induced neuronal cell death.

Comparison of Thermal Protective Performance Test of Firefighter's Protective Clothing against Convection and radiation heat sources (대류와 복사 열원에 대한 특수방화복의 열보호 성능시험 비교)

  • Kim, Hae-Hyoung;Yoo, Seung-Joon;Park, Pyoung-Kyu;Kim, Young-Soo;Hong, Seung-Tae
    • Fire Science and Engineering
    • /
    • v.31 no.2
    • /
    • pp.17-23
    • /
    • 2017
  • The test methods using convection (flame) and radiation heat sources were compared to evaluate the thermal protective performance of the firefighter's protective clothing. In particular, the influence of the outer shell, mid-layer, and lining constituting the firefighter's protective clothing on the thermal protective performance was compared for convection and radiation heat sources. Tests for the thermal protective performance were carried out according to KS K ISO 9151 (convection), KS K ISO 6942 (radiation), and KS K ISO 17492 (convection and radiation). When tested under the same incident heat flux conditions ($80kW/m^2$), the heat transfer index ($t_{12}$ and $t_{24}$) for the radiation heat source was higher than that for the convection heat source. This means that radiation has a lesser effect than convection. For the convection heat source, the lining had the greatest effect on the thermal protective performance, followed by the mid-layer and the outer shell. On the other hand, for the radiation heat source, the effect on the thermal protective performance was great in the order of lining, outer shell, and mid-layer. Convection and radiation have fundamentally different mechanisms of heat transfer, and different heat sources can lead to different thermal protective performance results depending on the material composition. Therefore, to evaluate the thermal protective performance of the firefighter's protective clothing, it is important to test not only the convection heat source, but also the radiation heat source.

A Study on the Digital Protective Relay for Generator Fault Protection (발전기 고장보호를 위한 디지털 계전기에 관한 연구)

  • Jang, Nak-Won;Park, Jeong-Do;Lee, Sung-Hwan
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.33 no.8
    • /
    • pp.1232-1238
    • /
    • 2009
  • As power facilities are getting higher at capacity, the monitoring and diagnosis of generators for fault detection and protection has attracted intensive interest. In case of an after-fault in high capacity rotating machines, the recovering cost is usually very expensive and additional time is necessary for returning in a normal situation. In this paper, we developed the protection program for the generator fault protection system and each module of the digital protective relay H/W for loading the protection program. The protective relay H/W was designed to have EMC characteristics for prohibiting from fault operation in bad power systems.

Development of Integrity Evaluation Instrument for the Power Line Surge Protective Device (전원용 SPD의 건전성 평가 장치 개발)

  • Chang, Sughun;Kim, Youngjin;Kim, Sungju;Kim, Jaehyung
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.4
    • /
    • pp.39-45
    • /
    • 2015
  • This paper deals with development of integrity evaluation instrument for the power line surge protective device. A reliable power supply is an essential element in the developed information and communication society by highly advances in IT technology. However, the lightning incidence also increased with the recent extreme weather events. In Korea, in order to protect the electrical system from lightning surge, SPD(Surge Protective Device) has been used for these past 30 years. However, the method of diagnosing the safety of the SPD in the industry is insufficient. In this paper, SPD integrity evaluation system was composed of a variable DC power source unit, voltage-current sensor and the embedded controller. In order to measure V-I characteristics of MOV, 3 type samples were degraded by impulse current generator. After impulse tests, the varistor voltage of all samples and nonlinearity coefficient were decreased. It confirmed the utility of the developed equipment by this experimental test and the reliability of SPD is expected for surge accident prevention when applied to industrial plant.