• Title/Summary/Keyword: Protective Capacity

Search Result 259, Processing Time 0.034 seconds

A Study on the Effectiveness of Protective Capacity in a Re-entrant Line (재투입 생산라인에서 방어적 생산능력의 효과성에 관한 연구)

  • 김선민;강현곤
    • Korean Management Science Review
    • /
    • v.17 no.1
    • /
    • pp.17-30
    • /
    • 2000
  • This paper addresses the effect of protective capacity on the lead time and throughput of a re-entrant line where statistical fluctuations exist in the form of variation in processing times and machine breakdowns. The specific framework employed in the paper is a five station re-entrant line structured as a closed network mode. This paper argues that protective capacity can be used in conjunction with WIP inventory in order to reduce the lead time and to increase the increase the throughput of a line. Simulation analyses are included to give insight into the effectiveness of protective capacity.

  • PDF

A Study on the Protective Capacity of Military Shelters in the Contact Areas (접적지역 대피소 방호수준 설정에 관한 연구)

  • Park, Young Jun;Park, Sangjin;Eom, Hong Seob;Son, Kiyoung
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.18 no.4
    • /
    • pp.402-408
    • /
    • 2015
  • Protection against direct projectiles has been adapted just to the main command posts in the existing protective facility standards. However, protective capacity for the shelters against direct projectiles is also required because the initial survivability as well as the operation sustainment of the shelters is critical during a couple of days from outbreak of war. In this study, the Russian artillery is used to determine the existing and future threat of the North Korean Armed Forces indirectly. And then, required protective capacity of military shelters in the contact areas is calculated along with UFC 3-340-02 and it is verified using modeling and simulation. Based on the assessed capacity, actual inspect of military facilities with contact areas on spot is performed whether military shelters have enough protection capacity against determined threats. According to the field study, it is verified that proper earth bermed shelter has enough protection capacity. The results in this study could be used how to retrofit the current shelters in the contact areas.

The Study on Assessment of Protective Capacity of the Reinforced Concrete Box-type Artillery Positions (철근콘크리트조 박스형 포상의 방호성능 평가)

  • Baek, Jonghyuk;Kim, Suk Bong;Son, Kiyoung;Park, Young Jun
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.17 no.2
    • /
    • pp.275-281
    • /
    • 2014
  • Although self-propelled artilleries are mobile equipment, they need their own covered-positions for survival against preemptive strikes. The most important military requirement is enough protective capacity against blast pressure caused by explosion. This paper aims to assess the protective capacity of the newly-placed concrete box-type artillery positions using accurate structural geometric models as well as soil-structure interaction analysis. The commercial program is used to model the structural geometry of the positions. In order to describe the correct wave propagation in the backfill along with soil-structure interaction, used parameters in shock equation of state are selected based on the related studies as well as theories and then their final results are verified with the ones calculated with empirical equations in the US Unified Facility Criteria. In sum, it could be concluded that the protective capacity of the newly-built positions satisfies the protective structural requirement.

Bending and Shear Capacity of Reinforced Concrete Protective Wall (휨과 전단을 고려한 철근콘크리트 방호벽 성능에 관한 연구)

  • Young Beom Kwon;Jong Yil Park
    • Journal of the Korean Society of Safety
    • /
    • v.38 no.2
    • /
    • pp.44-51
    • /
    • 2023
  • With the recent increase in gas energy use, risk management for explosion accidents has been emphasized. Protective walls can be used to reduce damage from explosions. The KOSHA GUIDE D-65-2018 suggests the minimum thickness and height of protective walls, minimum reinforcement diameter, and maximum spacing of reinforcements for the structural safety of the protective walls. However, no related evidence has been presented. In this study, the blast load carrying capacity of the protective wall was analyzed by the pressure-impulse diagrams while changing the yield strength of the reinforcement, concrete compressive strength, reinforcement ratio, protective wall height, and thickness, to check the adequacy of the KOSHA GUIDE. Results show that failure may occur even with design based on the criteria presented by KOSHA GUIDE. In order to achieve structural safety of protective walls, additional criteria for minimum reinforcement yield strength and maximum height of protective wall are suggested for inclusion in KOSHA GUIDE. Moreover, the existing value for minimum reinforcement ratio and the thickness of the protective wall should be increased.

The Ligthning Surge Protective Devices with Combination of Varistor and LC Filter (바리스터와 LC필터를 조합한 뇌써-지보호장치)

  • Kim, J.H.;Lee, K.O.;Lee, B.H.;Lee, Y.K.
    • Proceedings of the KIEE Conference
    • /
    • 1996.07c
    • /
    • pp.1873-1875
    • /
    • 1996
  • This paper deals with the lightning surge protective devices with combination of varistor and LC filter. UP to now, the varistor alone were used as overvoltage protection devices fer the AC power mains. In this work, in order to improve the cutoff performance of surge protective device, the hybrid circuit surge protective device for an AC single phase mains was designed and investigated. The first stage of hybrid circuit is to remove most of any large surge energy and protect the second stage components. The purpose of the second is to protect the load and increase the cutoff capacity of surge protective devices. Also LC filter attenuates the remnant that travels downstream from the first stage component and the high frequency noises. As a consequence, it was found that the proposed hybrid surge protective device for AC power mains has a variety of advantages such as low and tight clamping voltage, high frequency noise reduction and large cutoff capacity.

  • PDF

Analysis on the Application Capacity of the Superconducting Fault Current Limiter considering Reclosing and Fault Current (전력계통에 초전도한류기 적용시 차단용량 확보를 위한 초전도한류기 적용방안 연구)

  • Kim, Jin-Seok;Lim, Sung-Hun;Kim, Jae-Chul
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.592-593
    • /
    • 2015
  • Recently, the fault current has increased to exceed the rated breaking capacity of protective device due to the growth of the power demand on the power system where is changed into the loop-, mesh-, network grid. To limit fault current, the superconducting fault current limiter (SFCL) is announced with various methods. In many researches, the current limiting effect with the SFCL has been analyzed considering the rated breaking capacity of the CB with one fault condition. However, the power system has various short circuit and operation conditions. In order to select the capacity of the SFCL with reclosing operation and burden of the fault current on the protective device, the characteristics of the power system were investigated. Through the analysis, the evaluation method of the current rate was improved.

  • PDF

The Design and Protective Capacity Assessment of the Prefabricated PC Arch Ammo Magazines (아치형 조립식 PC 탄약고 설계 및 방호성능 평가)

  • Park, Jang-Kweon;Lim, Chul-Won;Ryu, Dong-Woo;Son, Ki-Young;Baek, Jong-Hyuk;Park, Young-Jun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.14 no.6
    • /
    • pp.615-621
    • /
    • 2014
  • This study suggests the design and assembly drawing of the prefabricated precast concrete arch ammo magazines using the numerical analysis as well as the explosion verification test. The protective capacity of the proposed magazines is identified with the maximum support rotation angles measured by explosion verification tests according to the U.S. Unified Facility Criteria 3-340-02. Using numerical analysis, it is examined that oval-type members are better than the semi-circle ones in terms of protective capacity. Based on this numerical results, the design and assemble drawing for the prefabricated precast concrete arch ammo magazine are developed. It is identified that the structure constructed by invented design and assembly drawing has enough protective capacity against blast pressure caused by 133.75kg TNT explosion. The detonation point cannot be open due to the military security. In sum, it could be concluded that the ammo magazine proposed in this study has reliable protective capacity with enough redundancy. The redundancy means that there are more economic design approach with reducing the curved wall thickness.

Protective Effect of Co-treatment of Lutein and Fucoidan Against AAPH-Induced Damage in THP-1 Cells (루테인과 후코이단 병용 처리에 의한 AAPH 유도 세포 손상 억제)

  • Lee, Keyong-Ho;Yoon, Won-Ho
    • The Korean Journal of Food And Nutrition
    • /
    • v.23 no.3
    • /
    • pp.306-310
    • /
    • 2010
  • This study was designed to investigate the protective effect of the combination of fucoidan and lutein against AAPH-induced oxidative stress in THP-1 cells. The combination of fucoidan and lutein existed significant antioxidant effect on AAPH-damaged THP-1 cells by using lipid peroxidation and cellular antioxidant capacity assay. Fucoidan($1\;{\mu}g/m{\ell}$) and lutein($10\;{\mu}g/m{\ell}$) did not affect at all the viability of THP-1 cells, but protected the AAPH-damage of THP-1 cells at the same concentration. The viability of THP-1 cells was 0% with 1 mM AAPH alone, the protective effect of fucoidan($1\;{\mu}g/m{\ell}$) and lutein($10\;{\mu}g/m{\ell}$) was 37% and 36%, respectively. The combination of fucoidan($1\;{\mu}g/m{\ell}$) and lutein($10\;{\mu}g/m{\ell}$) exhibited significant inhibitory effect of lipid peroxidation using TBARS assay and cellular antioxidant capacity using DCFH-DA assay. In lipid peroxidation, the TBARS value of 1 mM AAPH alone was $0.8{\pm}0.03\;nM$ MDA, its of the combination of fucoidan($1\;{\mu}g/m{\ell}$) and lutein($10\;{\mu}g/m{\ell}$) was $0.2{\pm}0.05\;nM$ MDA. In cellular antioxidant capacity, the combination of fucoidan($1\;{\mu}g/m{\ell}$) and lutein($10\;{\mu}g/m{\ell}$) exhibited significant cellular antioxidant capacity of 76%, whereas quercetin($10\;{\mu}M$) as positive control exhibited the cellular antioxidant capacity of 32%. These results indicate that the cotreatment of fucoidan and lutein protects against AAPH-induced THP-1 cell damage by inhibiting lipid peroxidation, increasing cellular antioxidant capacity.

A Study on the Formation and the Loss of the Protective Layer the Sliding Surface According to the Lubricating Conditions (미끄럼운동을 하는 면에 윤활 조건에 따라 발생하는 보호막의 형성과 파괴에 관한 연구)

  • 이영제
    • Tribology and Lubricants
    • /
    • v.7 no.1
    • /
    • pp.16-27
    • /
    • 1991
  • The mechanism of failure of lubricated surfaces at high sliding speeds was investigated. Experiments were performed with the ball-on-flat and cylinder-on-flat geometries, using lubricants of four different chemical reactivities. Surface failure was found to not be predictable using the ratio, $\lambda$, of fluid film thickness to composite surface roughness except when chemically inert lubricants are used. Even then the influence of temperature rise on fluid film thickness does not adequately explain the low load carrying capacity of lubricants at high sliding speeds, which causes surface failure. The protective layers on sliding surfaces that form by chemical reaction with the lubricant were found to reduce the surface roughening and increase the load carrying capacity of surfaces to values of $\lambda$ as low as 0.03. Neither the surface roughening nor the formation of the protective layers have been incorporated into failure models for lubricated systems.

Characterization, Antioxidant Capacity and Protective Effect of Peptides from Cordyceps militaris Cultivated with Tussah Pupa on Oxidative Injured HepG2 Cells

  • Bingxin Li;Jinying Zhang;Yefei Liu;Ze Wang;Fangxu Xu
    • Journal of Microbiology and Biotechnology
    • /
    • v.34 no.5
    • /
    • pp.1082-1091
    • /
    • 2024
  • The antioxidant capacity and protective effect of peptides from protein hydrolysate of Cordyceps militaris cultivated with tussah pupa (ECPs) on H2O2-injured HepG2 cells were studied. Results indicated ECP1 (<3 kDa) presented the strongest antioxidant activity compared with other molecular weight peptides. Pretreated with ECPs observably enhanced survival rates and reduced apoptosis rates of HepG2 cells. ECPs treatment decreased the ROS level, MDA content and increased CAT and GSH-Px activities of HepG2 cells. Besides, the morphologies of natural peptides from C. militaris cultivated with tussah pupa (NCP1) and ECP1 were observed by scanning electron microscopy (SEM). Characterization results suggested the structure of NCP1 was changed by enzymatic hydrolysis treatment. Most of hydrophobic and acidic amino acids contents (ACC) in ECP1 were also observably improved by enzymatic hydrolysis. In conclusion, low molecular weight peptides had potential value in the development of cosmetics and health food.