• 제목/요약/키워드: Protective Capacity

검색결과 259건 처리시간 0.03초

재투입 생산라인에서 방어적 생산능력의 효과성에 관한 연구 (A Study on the Effectiveness of Protective Capacity in a Re-entrant Line)

  • 김선민;강현곤
    • 경영과학
    • /
    • 제17권1호
    • /
    • pp.17-30
    • /
    • 2000
  • This paper addresses the effect of protective capacity on the lead time and throughput of a re-entrant line where statistical fluctuations exist in the form of variation in processing times and machine breakdowns. The specific framework employed in the paper is a five station re-entrant line structured as a closed network mode. This paper argues that protective capacity can be used in conjunction with WIP inventory in order to reduce the lead time and to increase the increase the throughput of a line. Simulation analyses are included to give insight into the effectiveness of protective capacity.

  • PDF

접적지역 대피소 방호수준 설정에 관한 연구 (A Study on the Protective Capacity of Military Shelters in the Contact Areas)

  • 박영준;박상진;엄홍섭;손기영
    • 한국군사과학기술학회지
    • /
    • 제18권4호
    • /
    • pp.402-408
    • /
    • 2015
  • Protection against direct projectiles has been adapted just to the main command posts in the existing protective facility standards. However, protective capacity for the shelters against direct projectiles is also required because the initial survivability as well as the operation sustainment of the shelters is critical during a couple of days from outbreak of war. In this study, the Russian artillery is used to determine the existing and future threat of the North Korean Armed Forces indirectly. And then, required protective capacity of military shelters in the contact areas is calculated along with UFC 3-340-02 and it is verified using modeling and simulation. Based on the assessed capacity, actual inspect of military facilities with contact areas on spot is performed whether military shelters have enough protection capacity against determined threats. According to the field study, it is verified that proper earth bermed shelter has enough protection capacity. The results in this study could be used how to retrofit the current shelters in the contact areas.

철근콘크리트조 박스형 포상의 방호성능 평가 (The Study on Assessment of Protective Capacity of the Reinforced Concrete Box-type Artillery Positions)

  • 백종혁;김석봉;손기영;박영준
    • 한국군사과학기술학회지
    • /
    • 제17권2호
    • /
    • pp.275-281
    • /
    • 2014
  • Although self-propelled artilleries are mobile equipment, they need their own covered-positions for survival against preemptive strikes. The most important military requirement is enough protective capacity against blast pressure caused by explosion. This paper aims to assess the protective capacity of the newly-placed concrete box-type artillery positions using accurate structural geometric models as well as soil-structure interaction analysis. The commercial program is used to model the structural geometry of the positions. In order to describe the correct wave propagation in the backfill along with soil-structure interaction, used parameters in shock equation of state are selected based on the related studies as well as theories and then their final results are verified with the ones calculated with empirical equations in the US Unified Facility Criteria. In sum, it could be concluded that the protective capacity of the newly-built positions satisfies the protective structural requirement.

휨과 전단을 고려한 철근콘크리트 방호벽 성능에 관한 연구 (Bending and Shear Capacity of Reinforced Concrete Protective Wall)

  • 권영범;박종일
    • 한국안전학회지
    • /
    • 제38권2호
    • /
    • pp.44-51
    • /
    • 2023
  • With the recent increase in gas energy use, risk management for explosion accidents has been emphasized. Protective walls can be used to reduce damage from explosions. The KOSHA GUIDE D-65-2018 suggests the minimum thickness and height of protective walls, minimum reinforcement diameter, and maximum spacing of reinforcements for the structural safety of the protective walls. However, no related evidence has been presented. In this study, the blast load carrying capacity of the protective wall was analyzed by the pressure-impulse diagrams while changing the yield strength of the reinforcement, concrete compressive strength, reinforcement ratio, protective wall height, and thickness, to check the adequacy of the KOSHA GUIDE. Results show that failure may occur even with design based on the criteria presented by KOSHA GUIDE. In order to achieve structural safety of protective walls, additional criteria for minimum reinforcement yield strength and maximum height of protective wall are suggested for inclusion in KOSHA GUIDE. Moreover, the existing value for minimum reinforcement ratio and the thickness of the protective wall should be increased.

바리스터와 LC필터를 조합한 뇌써-지보호장치 (The Ligthning Surge Protective Devices with Combination of Varistor and LC Filter)

  • 김지훈;이경옥;이복희;이영근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 C
    • /
    • pp.1873-1875
    • /
    • 1996
  • This paper deals with the lightning surge protective devices with combination of varistor and LC filter. UP to now, the varistor alone were used as overvoltage protection devices fer the AC power mains. In this work, in order to improve the cutoff performance of surge protective device, the hybrid circuit surge protective device for an AC single phase mains was designed and investigated. The first stage of hybrid circuit is to remove most of any large surge energy and protect the second stage components. The purpose of the second is to protect the load and increase the cutoff capacity of surge protective devices. Also LC filter attenuates the remnant that travels downstream from the first stage component and the high frequency noises. As a consequence, it was found that the proposed hybrid surge protective device for AC power mains has a variety of advantages such as low and tight clamping voltage, high frequency noise reduction and large cutoff capacity.

  • PDF

전력계통에 초전도한류기 적용시 차단용량 확보를 위한 초전도한류기 적용방안 연구 (Analysis on the Application Capacity of the Superconducting Fault Current Limiter considering Reclosing and Fault Current)

  • 김진석;임성훈;김재철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.592-593
    • /
    • 2015
  • Recently, the fault current has increased to exceed the rated breaking capacity of protective device due to the growth of the power demand on the power system where is changed into the loop-, mesh-, network grid. To limit fault current, the superconducting fault current limiter (SFCL) is announced with various methods. In many researches, the current limiting effect with the SFCL has been analyzed considering the rated breaking capacity of the CB with one fault condition. However, the power system has various short circuit and operation conditions. In order to select the capacity of the SFCL with reclosing operation and burden of the fault current on the protective device, the characteristics of the power system were investigated. Through the analysis, the evaluation method of the current rate was improved.

  • PDF

아치형 조립식 PC 탄약고 설계 및 방호성능 평가 (The Design and Protective Capacity Assessment of the Prefabricated PC Arch Ammo Magazines)

  • 박장권;임철원;류동우;손기영;백종혁;박영준
    • 한국건축시공학회지
    • /
    • 제14권6호
    • /
    • pp.615-621
    • /
    • 2014
  • 본 연구는 수치해석과 폭발 실증시험을 통해 조립식 PC 아치 탄약고의 설계 및 시공도면을 제시하였다. 제안된 탄약고의 방호성능은 미군의 UFC 3-340-02와 한국군의 국방 군사시설 설계기준(탄약고 설계지침)에서 제시된 최대 회전각도로 판별하였다. 아치형 탄약고의 기초설계를 위해 곡면형태인 반원형과 오발형에 대하여 폭발하중에 대한 방호성능을 수치해석을 통해 살펴본 결과 오발형이 타원형에 비하여 지점회전각이 적어 전반적으로 방호성능이 뛰어남을 확일 할 수 있었다. 이를 통해 아치형 조립식 PC 탄약고의 설계안 및 시공도를 제안하였으며, TNT 133.75kg을 구조체 벽체로부터 00m 이격하여 폭발시켜 실제 시공된 탄약고에 대한 방호성능을 검증하였다. 결론적으로, 본 연구에서 제안된 탄약고는 충분한 방호 여유력을 확보하고 있는 것으로 확인할 수 있었다. 향후 이러한 방호 여유력을 고려하여 재료의 절감을 통한 보다 경제적인 탄약고 설계도 가능할 것으로 사료된다.

루테인과 후코이단 병용 처리에 의한 AAPH 유도 세포 손상 억제 (Protective Effect of Co-treatment of Lutein and Fucoidan Against AAPH-Induced Damage in THP-1 Cells)

  • 이경호;윤원호
    • 한국식품영양학회지
    • /
    • 제23권3호
    • /
    • pp.306-310
    • /
    • 2010
  • This study was designed to investigate the protective effect of the combination of fucoidan and lutein against AAPH-induced oxidative stress in THP-1 cells. The combination of fucoidan and lutein existed significant antioxidant effect on AAPH-damaged THP-1 cells by using lipid peroxidation and cellular antioxidant capacity assay. Fucoidan($1\;{\mu}g/m{\ell}$) and lutein($10\;{\mu}g/m{\ell}$) did not affect at all the viability of THP-1 cells, but protected the AAPH-damage of THP-1 cells at the same concentration. The viability of THP-1 cells was 0% with 1 mM AAPH alone, the protective effect of fucoidan($1\;{\mu}g/m{\ell}$) and lutein($10\;{\mu}g/m{\ell}$) was 37% and 36%, respectively. The combination of fucoidan($1\;{\mu}g/m{\ell}$) and lutein($10\;{\mu}g/m{\ell}$) exhibited significant inhibitory effect of lipid peroxidation using TBARS assay and cellular antioxidant capacity using DCFH-DA assay. In lipid peroxidation, the TBARS value of 1 mM AAPH alone was $0.8{\pm}0.03\;nM$ MDA, its of the combination of fucoidan($1\;{\mu}g/m{\ell}$) and lutein($10\;{\mu}g/m{\ell}$) was $0.2{\pm}0.05\;nM$ MDA. In cellular antioxidant capacity, the combination of fucoidan($1\;{\mu}g/m{\ell}$) and lutein($10\;{\mu}g/m{\ell}$) exhibited significant cellular antioxidant capacity of 76%, whereas quercetin($10\;{\mu}M$) as positive control exhibited the cellular antioxidant capacity of 32%. These results indicate that the cotreatment of fucoidan and lutein protects against AAPH-induced THP-1 cell damage by inhibiting lipid peroxidation, increasing cellular antioxidant capacity.

미끄럼운동을 하는 면에 윤활 조건에 따라 발생하는 보호막의 형성과 파괴에 관한 연구 (A Study on the Formation and the Loss of the Protective Layer the Sliding Surface According to the Lubricating Conditions)

  • 이영제
    • Tribology and Lubricants
    • /
    • 제7권1호
    • /
    • pp.16-27
    • /
    • 1991
  • The mechanism of failure of lubricated surfaces at high sliding speeds was investigated. Experiments were performed with the ball-on-flat and cylinder-on-flat geometries, using lubricants of four different chemical reactivities. Surface failure was found to not be predictable using the ratio, $\lambda$, of fluid film thickness to composite surface roughness except when chemically inert lubricants are used. Even then the influence of temperature rise on fluid film thickness does not adequately explain the low load carrying capacity of lubricants at high sliding speeds, which causes surface failure. The protective layers on sliding surfaces that form by chemical reaction with the lubricant were found to reduce the surface roughening and increase the load carrying capacity of surfaces to values of $\lambda$ as low as 0.03. Neither the surface roughening nor the formation of the protective layers have been incorporated into failure models for lubricated systems.

Characterization, Antioxidant Capacity and Protective Effect of Peptides from Cordyceps militaris Cultivated with Tussah Pupa on Oxidative Injured HepG2 Cells

  • Bingxin Li;Jinying Zhang;Yefei Liu;Ze Wang;Fangxu Xu
    • Journal of Microbiology and Biotechnology
    • /
    • 제34권5호
    • /
    • pp.1082-1091
    • /
    • 2024
  • The antioxidant capacity and protective effect of peptides from protein hydrolysate of Cordyceps militaris cultivated with tussah pupa (ECPs) on H2O2-injured HepG2 cells were studied. Results indicated ECP1 (<3 kDa) presented the strongest antioxidant activity compared with other molecular weight peptides. Pretreated with ECPs observably enhanced survival rates and reduced apoptosis rates of HepG2 cells. ECPs treatment decreased the ROS level, MDA content and increased CAT and GSH-Px activities of HepG2 cells. Besides, the morphologies of natural peptides from C. militaris cultivated with tussah pupa (NCP1) and ECP1 were observed by scanning electron microscopy (SEM). Characterization results suggested the structure of NCP1 was changed by enzymatic hydrolysis treatment. Most of hydrophobic and acidic amino acids contents (ACC) in ECP1 were also observably improved by enzymatic hydrolysis. In conclusion, low molecular weight peptides had potential value in the development of cosmetics and health food.