• Title/Summary/Keyword: Protection system

Search Result 5,910, Processing Time 0.036 seconds

Operational characteristics analysis of protective relay for utility application of HTS power cable (초전도 전력케이블의 계통 적용을 위한 보호계전기의 동작특성 분석)

  • Kim, Jae-Ho;Kim, Jin-Geun;Sim, Ki-Deok;Cho, Jeon-Wook;Yoon, Jae-Young;Lee, Seung-Ryul;Park, Min-Won;Yu, In-Keun
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.57-58
    • /
    • 2008
  • Recently, several kinds of superconductivity applications are implemented and evaluated in the utility power networks. The protection system for HTS(High Temperature Superconducting) power devices safe operation has not been established yet. For the protection of the HTS apparatus, a better understanding of the quench properties against fault current and appropriate protection devices are required. In this study, an algorithm of protection system is developed with respect to HTS power cable. The protection system of HTS power cable was analyzed in the simulated power system. Results obtained from simulation will provide much more decisive data in order to design a certain superconducting power device, and can give a good information for the installation in power system.

  • PDF

The Simulation of Transmission Line Fault-Induced Noise Signals. (선로고장시 발생되는 잡음의 시뮬레이션)

  • Shin, Myung-Chul;Kim, Mu-Woong;Kim, Chul-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 1987.11a
    • /
    • pp.454-456
    • /
    • 1987
  • A more specialized area of transient evaluations is transmission line fault-detecting and protection system. During the first cycle or two following a power system fault, a high-speed protective relay is expected to make a decision as to the severity or location of the fault, usually based on 60 Hz information, i.e. the phase and magnitude of 60 Hz voltage or current signals. It is precisely at this time however that the signal is badly corrupted by noise, in the form of a de offset or frequencies above 50 Hz. One of several possible sources of transients in protection measuring signals is in the primary system for which protection is required in its response to the impact of short circuit fault on-set. Other sources are in the primary voltage and current transducers from which protection signals are derived, and, often of particular importance, in the interface circuits between the transducer secondaries and the comparator and measuring elements of the protection system. However, the noise signals that will be described in this paper are due to the main power system only and do not include errors due to current or voltage transducers.

  • PDF

A study of Automotive ESD Protection Circuit with improved Current Driving characteristics Using LVTSCR Structure (LVTSCR 구조를 이용한 향상된 전류구동 특성을 갖는 자동차용 ESD 보호회로 연구)

  • Bo-Bae Song;Young-Chul Kim
    • Journal of IKEEE
    • /
    • v.28 no.2
    • /
    • pp.204-208
    • /
    • 2024
  • In this paper, we propose an ESD protection circuit that applies structural changes to LVTSCR, a general low-voltage ESD protection circuit, to improve the current driving capability (IEC-ESD) characteristics of the ESD protection circuit. Power consumption was minimized by separating the area where the electric field and ESD current path are formed in the LVTSCR structure, and the electrical characteristics were analyzed and current driving characteristics were improved. Structural problems resulting from deterioration of system level characteristics were analyzed through simulation, and the characteristics were verified by reflecting this. The electrical characteristics of the proposed ESD protection circuit were verified using a TCAD simulator and analyzed through HBM modeling and system level modeling. In addition, silicon production and HBM 10kV characteristics were verified through DB-Hitek 0.18um BCD process.

The Personal Data Protection Mechanism in the European Union

  • Syroid, Tetiana L.;Kaganovska, Tetiana Y.;Shamraieva, Valentyna M.;Perederiі, Оlexander S.;Titov, Ievgen B.;Varunts, Larysa D.
    • International Journal of Computer Science & Network Security
    • /
    • v.21 no.5
    • /
    • pp.113-120
    • /
    • 2021
  • The adoption of the General Data Protection Regulation (EU) 2016/679 transformed approaches and concepts to the implementation of the personal data protection mechanism in the European Union. Within the EU, almost all countries have adapted a new protection mechanism, which requires a study of the specifics of its use. The article intends to assess the legal provisions of the current mechanism of personal data protection in the EU. The author studied the mechanism of personal data protection under the General Data Protection Regulation (EU) 2016/679 (GDPR) based on the concept of contextual integrity and analysis of EU legislation on personal data protection. The scientific publications for 2016-2020 were reviewed for the formation of ideas of a new personal data protection mechanism in the EU, informative and transparent analysis of legal provisions. The article notes that the personal data privacy and protection is increasing, there is an ongoing unification of the legal status of personal data protection and the formation of a digital market for dissemination, exchange, control, and supervision of data. Cross-border cooperation is part of the personal data protection mechanism. The author proved that the GDPR has changed approach to personal data protection: the emphasis is now shifting to the formation of a digital market, where the EU's role in ensuring regulation is crucial. The article identifies the emergence of a new protectionist legal system and strengthening of legal provisions regarding privacy. This legal system needs unification and harmonization in accordance with national legislation, is territorially fragmented and differentiated within the EU.

Development of an Imaging Based Gang Protection System

  • Grimm, M.;Pelz, M.
    • International Journal of Railway
    • /
    • v.1 no.4
    • /
    • pp.149-156
    • /
    • 2008
  • During maintenance or construction works in or at the tracks of railways, high risks for passengers and railway staff, especially for the workers on the construction site exist. The high risks result out of the movement of rail vehicles, like trains or construction vehicles, which must be faced by using any available technical and operational technologies for securing them against the environment. Therefore, it is necessary to evaluate the level of protection continuously and to identify new and innovative methods and technologies for the protection of the gang (construction worker, machines and material). Especially on construction sites at line sections with two or more parallel tracks but also with single tracks, there are still a lot of incidents and accidents mostly with seriously injured persons or fatalities. These were mainly gang members that breach the railway-loading gage. By using proper warning or protection systems, the avoidance of such accidents must be achieved. The latest developments. in gang protection systems concern on the one hand fixed barriers in the middle between the construction site and the operated track and on the other hand construction vehicles equipped with automatic warning systems. The disadvantage of such protection methods is that the gang can be warned against an approaching train but a monitoring of the gang members cannot be performed. Only one part of a potential dangerous situation will be detected. If the gang members will overhear the acoustic warning signal of the security staff and the workers will not leave the danger zone in the track, the driver of the approaching train had no chance to react to the dangerous situation. An accident is often inevitable. While the detection of acoustic warning signals by the gang members working on a construction site is very difficult, the acoustical planning of an automatic warning system has to be designed for an acoustic short range level of one meter besides the construction vehicle. The decision about the use of today's technical warning system (fixed systems, automatic warning systems, etc.) must be geared to the technical feasibility and the level of safety which is needed. Criteria for decision guidance to block a track should be developed by danger estimation and economical variables. To realize the actual jurisdiction and to minimize the hazards of railway operations by the use of construction vehicles near the tracks further developments are needed. This means, that the warning systems have to be enhanced to systems for protection, which monitor the realization of the warning signal as a precondition for giving a movement authority to a train. This method can protect against accidents caused by predictable wrongdoing. The actual state of the art technique of using a collective warning combined with additional security staff is no longer acceptable. Therefore, the Institute of Transportation System of the German Aerospace Center in Braunschweig (Germany) will develop a gang warning and protection system based upon imaging methods, with optical sensors such as video in visible and invisible ranges, radar, laser, and other. The advantage of such a system based on the possibility to monitor both the gang itself and the railway-loading gauge either of the parallel track or of the same track still in use. By monitoring both situations, the system will be able to generate a warning message for the approaching train, that there are obstacles in the track, so that the train can be stopped to prevent an accident. And also the gang workers will be warned, while they breach their area.

  • PDF

Protection Assessment using Reduced Power System Fault Data

  • Littler, T.B.
    • Journal of Electrical Engineering and Technology
    • /
    • v.2 no.2
    • /
    • pp.172-177
    • /
    • 2007
  • Wavelet transforms provide basis functions for time-frequency analysis and have properties that are particularly useful for the compression of analogue point on wave transient and disturbance power system signals. This paper evaluates the compression properties of the discrete wavelet transform using actual power system data. The results presented in the paper indicate that reduction ratios up to 10:1 with acceptable distortion are achievable. The paper discusses the application of the reduction method for expedient fault analysis and protection assessment.

Derivation of Protection Ratio and its Calculation for Microwave Relay System Based upon Composite Fade Margin and Availability (합성 페이드 마진 및 가용율에 근거한 M/W 중계 시스템의 보호비 유도 및 계산)

  • Suh, Kyoung-Whoan;Lee, Joo-Hwan
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.18 no.3 s.118
    • /
    • pp.341-350
    • /
    • 2007
  • In this paper, the derivation of protection ratio is newly proposed for the detailed planning of frequency coordination in microwave relay networks, and computed results for protection ratio of co-channel and adjacent channel are illustrated over the actual system and its frequency. It is shown that the suggested method based upon availability prediction can be expressed in terms of composite fade margin, interference-to-noise ratio(I/N), net filter discrimination, and system parameters. According to results, for 6.7 GHz, 60 km, 64-QAM, and I/N= -6 dB at BER $10^{-6}$, composite fade margin and co-channel protection ratio provide 25.5 and 50.7 dB, respectively. Also, net filter discrimination and adjacent channel protection ratio are obtained as 26.3 and 24.4 dB, respectively, at the first adjacent channel of 40 MHz. The proposed method provides some merits in computing protection ratio for microwave relay networks in view of an easy extension and practical applications considering more detailed and various system parameters.