• Title/Summary/Keyword: Protection of equipment

Search Result 751, Processing Time 0.022 seconds

Countermeasures for Flood Protection of Power Facility at Substation and Ground (수변전실 및 지상 전력기기 침수방지 대책에 관한 연구)

  • Kim, Gi-Hyun;Choi, Myeong-Il;Bae, Suk-Myong;Lee, Jae-Yong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.4
    • /
    • pp.78-84
    • /
    • 2008
  • Inundation of substation and ground power equipment broke out every summer season in low-lying downtown and low-lying shore by localized heavy rain, typhoon and tidal wave. In case inundation excluding the exchanging cost of equipment, it occurs a great economic and social loss owing to recovery time and events of electric shock occur by inundation electrical facility. So we researched the installation situation of substation and power equipment and inundation loss at Flood Danger Area. And we analyzed refutation or law relating to the flood protection counterplan of US, England Australia. We present flood protection countermeasures by survey and analyzing the internal standard and his paper will be used to resent a reform proposal of electrical feinted law about flood protection.

FAULT-TOLERANT DESIGN FOR ADVANCED DIVERSE PROTECTION SYSTEM

  • Oh, Yang Gyun;Jeong, Kin Kwon;Lee, Chang Jae;Lee, Yoon Hee;Baek, Seung Min;Lee, Sang Jeong
    • Nuclear Engineering and Technology
    • /
    • v.45 no.6
    • /
    • pp.795-802
    • /
    • 2013
  • For the improvement of APR1400 Diverse Protection System (DPS) design, the Advanced DPS (ADPS) has recently been developed to enhance the fault tolerance capability of the system. Major fault masking features of the ADPS compared with the APR1400 DPS are the changes to the channel configuration and reactor trip actuation equipment. To minimize the fault occurrences within the ADPS, and to mitigate the consequences of common-cause failures (CCF) within the safety I&C systems, several fault avoidance design features have been applied in the ADPS. The fault avoidance design features include the changes to the system software classification, communication methods, equipment platform, MMI equipment, etc. In addition, the fault detection, location, containment, and recovery processes have been incorporated in the ADPS design. Therefore, it is expected that the ADPS can provide an enhanced fault tolerance capability against the possible faults within the system and its input/output equipment, and the CCF of safety systems.

An Innovative Fast Relay Coordination Method to Bypass the Time Consumption of Optimization Algorithms in Relay Protection Coordination

  • Kheshti, Mostafa;Kang, Xiaoning;Jiao, Zaibin
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.2
    • /
    • pp.612-620
    • /
    • 2017
  • Relay coordination in power system is a complex problem and so far, meta-heuristic algorithms and other methods as an alternative approach may not properly deal with large scale relay coordination due to their huge time consuming computation. In some cases the relay coordination could be unachievable. As the urgency for a proper approach is essential, in this paper an innovative and simple relay coordination method is introduced that is able to be applied on optimization algorithms for relay protection coordination. The objective function equation of operating time of relays are divided into two separate functions with less constraints. As the analytical results show here, this equivalent method has a remarkable speed with high accuracy to coordinate directional relays. Two distribution systems including directional overcurrent relays are studied in DigSILENT software and the collected data are examined in MATLAB. The relay settings of this method are compared with particle swarm optimization and genetic algorithm. The analytical results show the correctness of this mathematical and practical approach. This fast coordination method has a proper velocity of convergence with low iteration that can be used in large scale systems in practice and also to provide a feasible solution for protection coordination in smart grids as online or offline protection coordination.

Analysis of Radiology Students' Behavior in Wearing Radiation Protection Equipment - based on the Theory of Planned Behavior (계획된 행위이론을 적용한 방사선학과 대학생들의 방사선 방어용 보호장구 착용에 대한 분석)

  • Noh, Ji-Sook;Lee, Byung-Hoon;Bea, Sang-Yul;Park, Hyung-Su;Ryu, So-Yen;Park, Jong
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.9
    • /
    • pp.443-452
    • /
    • 2011
  • This research aims at investigating the factors that affects the wearing of the nuclear protection equipment by radiology students. We measured the factors related to the wearing of the nuclear protection equipment based on the theory of planned behavior (TPB). We collected 192 survey records from 230 radiology students in Kwang-ju and Chun-nam providence who finished the clinical training. Based on Logistic Regression analysis, we found that the wearing of the nuclear protection equipment is statistically more probable as the level of study is lower, the scale of practicing hospital is smaller, the attitude rating is lower, and the rating of perceived behavioral control is higher. We argue that the development of educational program considering factors like the perceived behavioral control is required to enhance the degree of wearing the nuclear protection equipment in the clinical training of college students.

Privacy Protection from Unmanned Aerial Vehicle (무인항공기 사생활 보호 방안)

  • Lee, Bosung;Lee, Joongyeup;Park, Yujin;Kim, Beomsoo
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.26 no.4
    • /
    • pp.1057-1071
    • /
    • 2016
  • Privacy-right infringement using unmanned aerial vehicle (UAV) usually occurs due to the unregistered small UAV with the image data processing equipment. In this paper we propose that privacy protection acts, Personal Information Protection Act, Information and Communications Network Act, are complemented to consider the mobility of image data processing equipment installed on UAV. Furthermore, we suggest the regulations for classification of small UAVs causing the biggest concern of privacy-right infringement are included in aviation legislations. In addition, technological countermeasures such as recognition of UAV photographing and masking of identifying information photographed by UAV are proposed.

Protection Characteristics of Two-Stage Cascade SPD Systems (2단 종속 SPD시스템의 보호특성)

  • Lee, Bok-Hee;Shin, Hee-Kyung
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.5
    • /
    • pp.95-103
    • /
    • 2013
  • Protection of the electrical and electronic equipment against surges in low voltage AC power distribution systems is based on wide applications of surge protective devices(SPDs). Cascade application of SPDs located at the service entrance of a building and near sensitive equipment is intended to ensure the optimal voltage protection level and energy sharing among cascade SPDs. In this paper, when surges impinge at the service entrance of the building of interest, the protection characteristics of two-stage cascade SPD systems were investigated. The influence of the distance between the upstream and downstream SPDs on the voltage protection level and energy sharing of the two-stage cascade SPD systems were analyzed experimentally. It was found that the energy sharing of two-stage cascade SPD systems strongly depends on the distance between the two SPDs and the component of SPD. As the distance between the two SPDs increases, the energy absorbed by the upstream SPD increases while the energy absorbed by the downstream SPD decreases. Consequently, it is desirable to select the upstream and downstream SPDs having the proper energy capability with due consideration of the distance between the two SPDs.

An Analysis Measure for Cybersecurity linked Threat against Diverse Protection Systems (다양성보호계통 사이버보안 연계 위협 분석 방안)

  • Jung, Sungmin;Kim, Taekyung
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.17 no.1
    • /
    • pp.35-44
    • /
    • 2021
  • With the development of information technology, the cybersecurity threat continues as digital-related technologies are applied to the instrumentation and control system of nuclear power plants. The malfunction of the instrumentation and control system can cause economic damage due to shutdown, and furthermore, it can lead to national disasters such as radioactive emissions, so countering cybersecurity threats is an important issue. In general, the study of cybersecurity in instrumentation and control systems is concentrated on safety systems, and diverse protection systems perform protection and reactor shutdown functions, leading to reactor shutdown or, in the worst case, non-stop situations. To accurately analyze cyber threats in the diverse protection system, its linked facilities should be analyzed together. Risk analysis should be conducted by analyzing the potential impact of inter-facility cyberattacks on related facilities and the impact of cybersecurity on each configuration module of the diverse protection system. In this paper, we analyze the linkage of the diverse protection system and discuss the cybersecurity linkage threat by analyzing the availability of equipment, the cyber threat impact of the linked equipment, and the configuration module's cybersecurity vulnerability.

Analysis of IEC 61727 Photovoltaic (PV) systems Characteristics of the utility interface

  • Lee, Jeong Hyeon;Yoon, Yong Ho;Kim, Jae Moon
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.7 no.2
    • /
    • pp.90-95
    • /
    • 2015
  • This paper describes IEC 61727 standard of Photovoltaic (PV) systems -Characteristics of the utility interface. IEC 61727 standard tests include utility compatibility and personnel safety and equipment protection of PV inverter performance functions. Especially utility compatibility part includes test items of 1) voltage, current and frequency, 2) normal voltage operating range, 3) flicker, 4) DC injection, 5) normal frequency operating range, 6) harmonics and 7) waveform distortion, 8) power factor of PV inverter. Also personnel safety and equipment protection part includes test items 1)loss of utility voltage, 2)over/under voltage and frequency, 3)Islanding protection, 4)response to utility recovery, 5)earthing, 6)short circuit protection, 7)Isolation and switching of PV inverter. In this paper, each item of IEC 61727 standard test is studied and analyzed and finally full tested by PV inverter performance function.

A Study on the Response Characteristics of Fire Frequency 447 MHz and 2.4 GHz (소방용주파수 447 MHz와 2.4 GHz의 응답특성에 관한 연구)

  • Oh, Sae-Byeol;Kim, Si-Kuk;Jee, Seung-Wook;Lee, Chun-Ha;Kim, Hyeong-Gweon;SaKong, Seong-Ho
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.11a
    • /
    • pp.31-34
    • /
    • 2011
  • 본 논문은 소방용 무선주파수로 도입 예정인 447 MHz와 2.4 GHz의 응답특성을 확인하고자, 한국소방산업기술원에서 개발된 447 MHz 무선모듈과 2.4 GHz 무선모듈을 이용하여 건축물 내에서 무선통신 환경에 영향을 줄 수 있는 대표적 장애물인 벽체를 시료로 하여 두 주파수 간의 응답특성을 비교 분석하였다. 도출된 결과를 바탕으로 향후 도입될 소방용 무선주파수 선정을 위한 기초 자료로 활용하고자 한다.

  • PDF

A Study on the Transient Characteristic and Protection Schemes of Sheath Circulating Current Reduction Equipment (시스 순환전류 저감장치의 과도특성 및 보호방식에 관한 연구)

  • 강지원;한용희;정채균;이종범
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.52 no.7
    • /
    • pp.421-428
    • /
    • 2003
  • After the cable is installed, many geometric factors, such as bowing types of the cable and the length difference of the cable between each minor section will cause the impedance unbalance between cables. The impedance unbalance will increase or decrease the sheath circulating currents, which are critical to human safety and sustaining the capabilities of electric power. Accordingly, in this paper, a new method is also proposed to reduce the sheath circulating currents and an reduction equipment according to the theory of the new method is developed. The reduction equipment is tested when the cable is on service. The test results show that it can reduce the sheath circulating currents by up to 97.8[%]. This confirms the validation of the new method and the reduction equipment, and assures the safe operation of the transmission cables. In order to illustrate the safe operation of the cable with new current reduction equipment at transient state due to lightning and single line-to-ground fault, extensive simulations have been made. Then the protection scheme of sheath circulating currents reduction equipment is proposed by adopting the new device of RDP(Reduction Device Protector).