• Title/Summary/Keyword: Protection methods

Search Result 2,532, Processing Time 0.028 seconds

ESD Protection Circuits with Low-Voltage Triggered SCR for RF Applications

  • Kim, San-Hong;Park, Jae-Young;Kim, Taek-Soo
    • Proceedings of the IEEK Conference
    • /
    • 2008.06a
    • /
    • pp.24-25
    • /
    • 2008
  • An Electrostatic discharge (ESD) protection has been a very important reliability issue in microelectronics, especially for RF (Radio Frequency) integrated circuits (ICs). This paper reviews design and analysis of on-chip ESD (electrostatic discharge) protection circuits for RF applications. Key issues in RF ESD protection, design methods, and RF ESD protection solutions are discussed.

  • PDF

Methods of Improving Operational Reliability of Oil Well Casing

  • Sergey A. Dolgikh;Irek I. Mukhamatdinov
    • Corrosion Science and Technology
    • /
    • v.23 no.1
    • /
    • pp.1-10
    • /
    • 2024
  • Oil well casing leak is caused by contact of casing outer surface with formation electrolyte. It is usually associated with an aquifer with a high salt content or absence of a cement ring behind the casing. The only way to reduce external casing corrosion is through cathodic protection. Through cathodic polarization of casing structure, electron content in crystal lattice and electron density will increase, leading to a potential shift towards the cathodic region. At Tatneft enterprises, cathodic protection is carried out according to cluster and individual schemes. The main criterion for cathodic protection is the size of protective current. For a casing, the protective current is considered sufficient if measurements with a two-contact probe show that the electric current directed to the casing has eliminated all anode sites. To determine the value of required protective current, all methods are considered in this work. In addition, an analysis of all methods used to determine the minimum protective current of the casing is provided. Results show that the method of measuring potential drop along casing is one of the most reliable methods for determining the value of protective current.

Protection Coordination Strategy of Microgrid Demonstration Site (마이크로그리드 실증사이트의 보호협조 전략)

  • Jin, Dae-Geun;Choi, Won-Jun;Won, Dong-Jun;Lee, Hak-Ju;Chae, Woo-Kyu;Park, Jung-Sung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.7
    • /
    • pp.966-973
    • /
    • 2012
  • In microgrid demonstration site, distributed generations can make bidirectional power flows on the system. If an accident occurs, the fault current from the inverter based distributed generation is small. However, the conventional protection scheme in distribution network is designed to operate at high fault current. This means that the traditional protection of distribution network is no longer applicable and new protection methods must be developed. In this paper, for two cases, algorithms for protection coordination of demonstration site is proposed and verified through PSCAD/EMTDC simulation. In first case, protection devices are assumed to have the abilities of directional relaying and communication. In second case, protection devices do not have those abilities. Proposed protection coordination algorithms detect the fault locations and protect the microgrid fairly well.

A Study on Improvement of Ballistic Testing Method for Combat Helmet (방탄헬멧의 방탄시험방법 개선에 관한 연구)

  • Gu, Seung Hwan;Kim, Kyung Min;Park, Jung Hwa;Song, Seung Hwan
    • Journal of Korean Society for Quality Management
    • /
    • v.47 no.2
    • /
    • pp.283-294
    • /
    • 2019
  • Purpose: Although the development of bulletproof helmets continues to be carried out, little has been improved in testing methods. Therefore, in this study, we studied the improvement of the test method of the domestic bulletproof helmet. Methods: The causes of head damage in the battlefield and the trends of bulletproof helmet development in developed countries were analyzed. In addition, improvements were derived by comparing the test methods of bulletproof helmet in Korea and the United States. Results: The results of the improvement by comparing the test methods of bulletproof helmet in Korea and the United States are as follows First, it is an addition to the scope of environmental treatment. Second, it is an addition to the level of protection. Third, the addition of the level of protection by impact. Conclusion: This study considered testing methods to prevent head injuries to shocks that cannot be identified by conventional methods. In addition, it considered testing methods for various threats by improving protection performance to advanced countries' levels.

A study on the thermal reponsivenes of automatic sprinklers (스프링클러 소화설비의 열감지에 관한 연구)

  • Son, Bong-Se
    • Fire Protection Technology
    • /
    • s.10
    • /
    • pp.9-12
    • /
    • 1991
  • As the present idustry is devolping rapidly, automatic sprinklers continue to play a key role in modern fire protection. But the technical basis and methods of measurement of the thermal response of sprinklers are not studying in our country. Therefore, the purpose of this paper is to analyze the thermal response characteristics and condition parameters of automatic sprinkler head.

  • PDF

Selection of concrete lining corrosion protection method for large sewer tunnels (하수터널의 콘크리트 라이닝 부식 방지공법 선정방법에 관한 고찰)

  • Moon, Joon-Shik;Lee, Sungjune
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.16 no.4
    • /
    • pp.347-360
    • /
    • 2014
  • Recently construction of large sewer tunnels used also as underground sluiceways/storages is increasing in order to prevent urban inundation, untreated sewage flow into rivers from combined sewer overflows and consequential river pollution due to climate change. Most of these large sewer tunnels are constructed with concrete and the concrete lining should be protected from corrosion caused by hydrogen sulfide($H_2S$). This paper introduced popular concrete corrosion protection methods for large sewer tunnels with 100-plus years of life cycle, and pros and cons of each corrosion protection methods were described by giving specific examples. However, it is difficult to objectively assess corrosion protection alternatives because of insufficient track record of corrosion protection methods applied to large sewer tunnels. In this paper, the evaluation process for selecting a corrosion protection alternative was introduced for large sewer tunnels using a case study.

Numerical analysis results of the cathodic protection for the underground steel pipe by anode installation method

  • Jeong, Jin-A;Choo, Yeon-Gil;Jin, Chung-Kuk;Park, Kyeong-Wan
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.10
    • /
    • pp.1212-1216
    • /
    • 2014
  • This study aims to find out the best anode location for buried pipelines. Numerical simulation program known as CATPRO (Elsyca, Belgium) were used for confirming the best location of anodes and the effects of impressed current cathodic protection system. Applied conditions for numerical simulation were similar to on-site environmental conditions for optimal application of cathodic protection system. Used criterion of cathodic protection was NACE SP 0169, which describes that minimum requirement for cathodic protection is -850mV vs. CSE. Various layouts for anodes' installation were applied, which were distance between anodes, anode installation location, and applied current. The areas where cathodic protection potential was lower than -850mV vs. CSE was limited up to 50m from anode installation locations. It was founded numerical analysis obtain cost-effective and efficient cathodic protection methods before design and application the impressed cathodic protection system to on-site environment.

Relationship between Information Security Education and Information Protection Practice of Hospital (의료기관의 정보보호교육과 정보보안생활과의 관련성)

  • Kim, Jongdeok;Hong, Hwayong;Kim, Jae-Hyun
    • Korea Journal of Hospital Management
    • /
    • v.24 no.2
    • /
    • pp.56-66
    • /
    • 2019
  • PURPOSE: To demonstrate that the training of information protection for members at medical institutions increases the information protection activities of employees. METHODS: We used the chi-square test and the logistic regression model to analyze the data of the "Healthcare Information and Communication Status Survey in 2017" (n = 2002) conducted by the Korea Health Industry Development Institute RESULTS: As a result of the analysis, the information protection activity increased when the education was received and the number of received more than the education was not received. Especially, when the management receives education, it affects the information protection activities of the employees. CONCLUSION: In order to protect medical information, medical institutions need to provide education on information protection for management and employees.

Rapid Detection of SdhBP225F and SdhBH272R Mutations in Boscalid Resistant Botrytis cinerea Strains by ARMS-PCR

  • Liu, Xin;Zeng, Rong;Gao, Shigang;Xu, Lihui;Dai, Fuming
    • The Plant Pathology Journal
    • /
    • v.35 no.1
    • /
    • pp.71-76
    • /
    • 2019
  • $SdhB^{P225F}$ and $SdhB^{H272R}$ mutations have been found associated with boscalid resistance in Botrytis cinerea from strawberry in Shanghai, China. For rapid detection of two mutations, tetra-primers were designed and optimized to gain the relatively high accuracy and specificity based on the ARMS-PCR technique, by which resistance can be identified with different lengths of products on agarose gels. The tetra-primer ARMS-PCR systems for $SdhB^{P225F}$ and $SdhB^{H272R}$ were validated by 9 SdhB-squenced strains repeatedly. Then, sensitivity of 30 more strains were also tested by the methods, which were accordant with genotypes by sequencing and the sensitivity of conidial germination to boscalid by 100%. Thus, the methods developed in this study are proved to be rapid, inexpensive, accurate and practical for resistance detection of Botrytis cinerea caused by $SdhB^{P225F}$ and $SdhB^{H272R}$ mutations.

Study on Propriety Evaluation for Protection of Rock Revetment (석축호안 보호공의 적정성 평가에 대한 연구)

  • Park, Moo-Jong;Choi, Sung-Wook;Baek, Chun-Woo
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.8 no.5
    • /
    • pp.111-117
    • /
    • 2008
  • Recent climate changes have increased flood damage on bank and revetment. However design standard for revetment that is the one of the most important facility for flood protection is not enough in Korea. In this study, destruction of rock revetment in Guryecity caused by the flood on Aug 2007 was inquired by analysis using 2D hydraulic simulation model SMS and the propriety of established plan for protection of rock revetment was evaluated. For this purpose, the ranges of protection facility for revetment was calculated by two methods. The one is normal method to calculate range of pier scour protection facility, and the other is a method of the standard for river design in Korea. The results of both methods are compared to evaluate the established plan.