• Title/Summary/Keyword: Protection measure

Search Result 598, Processing Time 0.025 seconds

Monte Carlo Study of MOSFET Dosimeter Dose Correction Factors Considering Energy Spectrum of Radiation Field in a Steam Generator Channel Head (원전 증기발생기 수실 내 에너지 스펙트럼을 고려한 MOSFET 방사선검출기 선량보정인자 결정에 관한 몬테칼로 전산모사 연구)

  • Cho, Sung-Koo;Choi, Sang-Hyoun;Kim, Chan-Hyeong
    • Journal of Radiation Protection and Research
    • /
    • v.31 no.4
    • /
    • pp.165-171
    • /
    • 2006
  • In Korea, a real-time effective dose measurement system is in development. The system uses 32 high-sensitivity MOSFET dosimeters to measure radiation doses at various organ locations in an anthropomorphic physical phantom. The MOSFET dosimeters are, however, mainly made of silicon and shows some degree of energy and angular dependence especially for low energy photons. This study determines the correction factors to correct for these dependences of the MOSFET dosimeters for accurate measurement of radiation doses at organ locations in the phantom. For this, first, the dose correction factors of MOSFET dosimeters were determined for the energy spectrum in the steam generator channel of the Kori Nuclear Power Plant Unit #1 by Monte Carlo simulations. Then, the results were compared with the dose correction factors from 0.652 MeV and 1.25 MeV mono-energetic photons. The difference of the dose correction factors were found very negligible $(\leq1.5%)$, which in general shows that the dose corrections factors determined from 0.662 MeV and 1.25 MeV can be in a steam general channel head of a nuclear power plant. The measured effective dose was generally found to decrease bit $\sim7%$ when we apply the dose correction factors.

Study on Preventing Retaliation against Crime Victims (범죄피해자에 대한 보복범죄 방지 대책에 관한 연구)

  • Choi, KeeNam
    • Convergence Security Journal
    • /
    • v.16 no.7
    • /
    • pp.129-137
    • /
    • 2016
  • The guarantee of citizens' safety from crime is the reason for a nation's existence according to the social contract, and it is also a salient task in securing the citizens' right to the pursuit of happiness, which is a constitutional right expressing the nation's duty to its citizens. First, a procedure must be made mandatory that corresponds to the Miranda rule applied during the arrest of criminal suspect, which verifies whether there exists a risk of retaliatory crime to the victim of crime, crime reporter, or witness following their report of a crime or testimony. A measure to punish those who violate this should be devised. The second is the improvement of related laws and systems, such as expanding the scope of persons subject to protection from retaliatory crimes under the current law and strengthening information protection. Third, a retaliatory crime risk evaluation index must be developed, and the evaluation results must be quantified to clearly state measures and responsibilities, in detail, for personal safety at each level of intensity. The fourth is the expanded implementation of proactive personal safety measures for victims of crime and witnesses, as well as the development and application of advanced techniques. The last is a change in the perception s of those working for the judicial body. From the initial investigation stage of the crime to the diagnosis regarding the possibility of retaliation perpetrated on an ex-convict through psychological tests, systems of general cooperation, and mutual assistance must be established.

Possibility of Involvement of Porphyromonas gingivalis in Coronary Heart Disease

  • Lee, Jin-Yong;Park, Byung-Lae;Yun, Hyun-Kyung;Park, Eun-Ah;Shin, Eun-Ah;Jue, Seong-Suk;Shin, Je-Won
    • The Journal of the Korean Society for Microbiology
    • /
    • v.35 no.3
    • /
    • pp.203-214
    • /
    • 2000
  • Porphyromonas gingivalis has been implicated in periodontal diseases. Accumulating evidence suggests that cardiovascular disease is the most prevalent medical problem in patients with periodontal diseases. In order to check the possibility that P. gingivalis is involved in coronary heart disease, the present study was performed to observe P. gingivalis adherence and invasion of human coronary artery endothelial cells (HCAEC) and production of cytokines and growth factors by HCAEC upon P. gingivalis infection. $^3H$-labeled P. gingivalis 381 was incubated with HCAEC for 90 min. The radioactivity of the washed HCAEC was a measure of the absorbed (adhering and invading) P. gingivalis. The absorption radioactivity of the HCAEC infected by P. gingivalis was determined to be 59.58% of the input bacterial cells. In contrast, the absorption radioactivity of the cells infected by S. gordonii Challis which was employed as a control was negligible (0.59%). DPG3, a P. gingivalis mutant defective of fimbriae, appeared to be impaired to some extent in capability of adherence/invasion as compared to that of the parental strain 381, showing 43.04% of the absorption radioactivity. The absorption radioactivity of the HCAEC infected by P. gingivalis 381 in the presence of excessive fimbriae at the concentrations of $50\;{\mu}g$ and $100\;{\mu}g/ml$ was 57.27 and 45.44%, respectively. Invasion of HCAEC by P. gingivalis 381 was observed by an antibiotic (metronidazole) protection assay and transmission electron microscopy (TEM). In the antibiotic protection assay, invasion by the bacterium was measured to be 0.73, 1.09, and 1.51% of the input bacterial cells after incubation for 30, 60, and 90 min, respectively. Invasion by DPG3 was shown to be 0.16% after 90-min incubation. In comparison of invasion efficiency at 90 min of the incubation, the invasion efficiency of DPG3 was 0.37% while that of its parental strain 381 was 2.54%. The immunoblot analysis revealed fimbriae of P. gingivalis did not interact with the surface of HCAEC. These results suggest that fimbriae are not the major contribution to the adherence of P. gingivalis to HCAEC but may be important in the invasion of HCAEC by the bacterium. The presence of cytochalasin D ($1\;{\mu}g/ml$) and staurosporine ($1\;{\mu}M$) reduced the invasion of HCAEC by P. gingivalis 381 by 78.86 and 53.76%, respectively, indicating that cytoskeletal rearrangement and protein kinase of HCAEC are essential for the invasion. Infection of P. gingivalis induced HCAEC to increase the production of TNF-${\alpha}$. by 60.6%. At 90 min of the incubation, the HCAEC infected with P. gingivalis cells was apparently atypical in the shape, showing loss of the nuclear membrane and subcellular organelles. The overall results suggest that P. gingivalis may cause coronary heart disease by adhering to and invading endothelial cells, and subsequently damaging the cells.

  • PDF

Evaluation of Residual Radiation and Radioactivity Level of TRIGA Mark-II, III Research Reactor Facilities for Safe Decommissioning (TRIGA Mark-II, III 연구로 시절의 폐로를 위한 시설의 잔류 방사선/능 평가)

  • Lee, B.J.;Chang, S.Y.;Park, S.K.;Jung, W.S.;Jung, K.J.
    • Journal of Radiation Protection and Research
    • /
    • v.24 no.2
    • /
    • pp.109-120
    • /
    • 1999
  • Residual radiation and radioactivity level in TRIGA Mark-II, III research reactors and facilities at the KAERI Seoul site, which are to be decommissioned, have been measured, analyzed and evaluated to know the current status of radiation and radioactivity level and to establish and to provide the technical requirements for the safe decommissioning of the facilities which shall be applied in minimizing the radiation exposure for workers and in preventing the release of the radioactive materials to the environment. Radiation dose rate and surface radioactivity contamination level on the experimental equipments, floors, walls of the facilities, and the surface of the activated materials within the reactor pool structure were measured and evaluated. Radioactivity and radionuclides in the pool and cooling water were also analyzed. In case of the activated reactor pool structures which are very difficult to measure the radiation and radioactivity level, a computer code Fispin was additionally used for estimation of the residual radioactivity and radionuclides. The radiation and radioactivity data obtained in this study were effectively used as basic data for decontamination and dismantling plan for safe decommissioning of TRIGA Mark-II, III facilities.

  • PDF

Measurement of Skin Dose for Rectal Cancer Patients in Radiotherapy using Optically Stimulated Luminescence Detectors (OSLDs) (광자극발광선량계(OLSDs)를 이용한 직장암 방사선치료 환자의 피부선량 측정)

  • Im, In-Chul;Yu, Yun-Sik;Lee, Jae-Seung
    • Journal of Radiation Protection and Research
    • /
    • v.36 no.2
    • /
    • pp.86-92
    • /
    • 2011
  • This study used the optically stimulated luminescence dosimeters (OSLDs), recently, received the revaluation of usefulness in vivo dosimetry, and the diode detecters to measure the skin dose of patient with the rectal cancer. The measurements of dose delivered were compared with the planned dose from the treatment planning system (TPS). We evaluated the clinical application of OSDs in radiotherapy. We measured the calibration factor of OSLDs and used the percent depth dose to verified, also, we created the three point of surface by ten patients of rectal cancer to measured. The calibration factors of OSLD was 1.17 for 6 MV X-ray and 1.28 for 10 MV X-ray, demonstrating the energy dependency of X-ray beams. Comparison of surface dose measurement using the OSLDs and diode detectors with the planned dose from the TPS, The skin dose of patient was increased 1.16 ~ 2.83% for diode detectors, 1.36 ~ 2.17% for OSLDs. Especially, the difference between planned dose and the delivery dose was increased in the perineum, a skin of intense flexure region, and the OSLDs as a result of close spacing of measuring a variate showed a steady dose verification than the diode detecters. Therefore, on behalf of the ionization chamber and diode detecters, OSLDs could be applied clinically in the verification of radiation dose error and in vivo dosimety. The research on the dose verification of the rectal cancer in the around perineal, a surface of intense flexure region, suggest continue to be.

Clinical Apply of Dual Energy CT (kVp switching) : A Novel Approach for MAR(Metal Artifact Reduction) Method (듀얼에너지 CT(kvp switching)의 임상 적용: MAR(Metal Artifact Reduction) 알고리즘의 적용)

  • Kim, Myeong-Seong;Jeong, Jong-Seong;Kim, Myeong-Goo
    • Journal of Radiation Protection and Research
    • /
    • v.36 no.2
    • /
    • pp.79-85
    • /
    • 2011
  • OThe purpose of this article was to measure and compare the value of the metal artifact reduction (MAR) algorithm by Dual energy(kVp switching) CT (Computed Tomography) for non using MAR and we introduced new variable Dual energy CT applications through a clinical scan. The used equipment was GE Discovery 750HD with Dual-Energy system(kVp switching). CT scan was performed on the neck and abdomen area subject for patients. Studies were from Dec 20 2010 to Feb 10 2011 and included 25 subject patients with prosthesis. We were measured the HU (Hounsfield Unit) and noise value at metal artifact appear(focal loss of signal and white streak artifact area) according to the using MAR algorithm. Statistical analyses were performed using the paired sample t-test. In patient subject case, the statistical difference of showing HU was p=0.01 and p=0.04 respectively. At maximum black hole artifact area and white streak artifact area according to the using MAR algorithm. However noise was p=0.05 and p=0.04 respectively; and not the affected black hole and white streak artifact area. Dual Energy CT with the MAR algorithm technique is useful reduce metal artifacts and could improve the diagnostic value in the diagnostic image evaluation of metallic implants area.

Manufacture of Immobilization Device (Vac-lok) and the Usefulness of Evaluation for Reproducibility of Patients in the Radiotherapy (환자의 재현성을 위한 고정장치(Vac-lok) 제작과 방사선치료에서 유용성 평가)

  • Lee, Jae-Seung;Kim, Gyoung-Hee;Jeong, Kyu-Hwan;Kweon, Dae-Cheol;Goo, Eun-Hoe;Park, Cheol-Woo;Im, In-Chul;Dong, Kyung-Rae;Chung, Woon-Kwan
    • Journal of Radiation Protection and Research
    • /
    • v.36 no.1
    • /
    • pp.8-16
    • /
    • 2011
  • We manufactured the Vac-lok that can be applied to patient of special body shape and need to special set-up position and evaluated the usefulness in the radiation therapy. The manufacture Vac-lok, It was used EVA resin and biobeadform of a diameter 1.5 mm. carried out the test of functionality, structural and analyzed the relative reproducibility of phantoms and patients. During the total period of radiation therapy, Vacuum pressure bring variety to a very small amount in the test of functionality of the manufacture Vac-lok. But It was a negligible quantity. The manufacture Vac-lok improved the relative reproducibility of phantoms than the existing Vac-lok and tolerance has a confidence less than 4% error. Also, relative reproducibility of patient increased error than phantom in the antero-posterior and lateral plan. However, the maximum set-up error was less than ${\pm}\;2.3$ mm. In conclusion, If tolerance set-up error of radiotherapy is less than ${\pm}\;3$ mm, the manufacture Vac-lok was enough possible to use and improvement of reproducibility, considering supply with the Vac-lok made to measure of special patient that produced at a low price and without delay.

Analysis of Uranium Concentrations in Urine Samples Using Alpha Spectrometry and Dose Assessment (알파분광분석법을 이용한 소변시료 중 우라늄 농도 분석 및 선량평가)

  • Lee, Na-Rae;Han, Seung-Jae;Cho, Kun-Woo;Jeong, Kyu-Hwan;Lee, Dong-Myung
    • Journal of Radiation Protection and Research
    • /
    • v.38 no.3
    • /
    • pp.138-142
    • /
    • 2013
  • This study was conducted to measure the uranium concentrations in urine of some members of the general public in Busan and Daejeon and to assess the annual committed effective doses from uranium analysis of daily excretion. As a result, the ranges of total uranium concentrations in the urine for the residents in Busan and Daejeon were found to be 0.556 - 1.53 $mBq\;L^{-1}$ and 2.18 - 4.55 $mBq\;L^{-1}$, respectively. It was noted that the uranium concentrations for the residents in Daejeon were observed to be higher than those for the residents in Busan. This result assumes that the uranium concentrations in the urines for the residents in Daejeon are probably related to the high uranium concentrations contained in the drinking water of Daejeon city. The bedrock of Daejeon, known as granitic rocks formed in the Jurassic period of the Mesozoic Era, contains high uranium contents. Also, results showed no significant correlation with age or sex. The ranges of annual committed effective doses from ingestion of uranium for the residents in Busan and Daejeon were calculated to be 0.472-1.41 ${\mu}Sv$ and 1.99-4.15 ${\mu}Sv$, respectively.

Evaluation of Source Identification Method Based on Energy-Weighting Level with Portal Monitoring System Using Plastic Scintillator

  • Lee, Hyun Cheol;Koo, Bon Tack;Choi, Chang Il;Park, Chang Su;Kwon, Jeongwan;Kim, Hong-Suk;Chung, Heejun;Min, Chul Hee
    • Journal of Radiation Protection and Research
    • /
    • v.45 no.3
    • /
    • pp.117-129
    • /
    • 2020
  • Background: Radiation portal monitors (RPMs) involving plastic scintillators installed at the border inspection sites can detect illicit trafficking of radioactive sources in cargo containers within seconds. However, RPMs may generate false alarms because of the naturally occurring radioactive materials. To manage these false alarms, we previously suggested an energy-weighted algorithm that emphasizes the Compton-edge area as an outstanding peak. This study intends to evaluate the identification of radioactive sources using an improved energy-weighted algorithm. Materials and Methods: The algorithm was modified by increasing the energy weighting factor, and different peak combinations of the energy-weighted spectra were tested for source identification. A commercialized RPM system was used to measure the energy-weighted spectra. The RPM comprised two large plastic scintillators with dimensions of 174 × 29 × 7 ㎤ facing each other at a distance of 4.6 m. In addition, the in-house-fabricated signal processing boards were connected to collect the signal converted into a spectrum. Further, the spectra from eight radioactive sources, including special nuclear materials (SNMs), which were set in motion using a linear motion system (LMS) and a cargo truck, were estimated to identify the source identification rate. Results and Discussion: Each energy-weighted spectrum exhibited a specific peak location, although high statistical fluctuation errors could be observed in the spectrum with the increasing source speed. In particular, 137Cs and 60Co in motion were identified completely (100%) at speeds of 5 and 10 km/hr. Further, SNMs, which trigger the RPM alarm, were identified approximately 80% of the time at both the aforementioned speeds. Conclusion: Using the modified energy-weighted algorithm, several characteristics of the energy weighted spectra could be observed when the used sources were in motion and when the geometric efficiency was low. In particular, the discrimination between 60Co and 40K, which triggers false alarms at the primary inspection sites, can be improved using the proposed algorithm.

A Study on ASET Elongation & Notification Time to Fire Stations for the Escape Safety of Aged Bedridden Patients in Elderly Long-term Medical Care (노인의료복지시설 화재 시 와상노인의 피난안전성 제고를 위한 피난허용시간 연장과 소방기관으로의 통보시간 연구)

  • Park, Hyung-Joo;Lee, Young-Jae
    • Fire Science and Engineering
    • /
    • v.32 no.4
    • /
    • pp.50-59
    • /
    • 2018
  • Recently, huge life losses occurred in the elderly long-term medical care fires due to lack of escape safety. As part of the measures to enhance the effectiveness of fire escape safety, while they prolong the available safe egress time (ASET) of non fire compartments, a measure to shorten fire-fighter's arrival time by fire alarm notifying device should be implemented in these facilities. The four categories from the aspects of fire prevention/protection engineering were provided with the necessary component technologies for carrying out these helper-guided evacuations. Fire prevention engineered technology was presented by two provisions; one for ensuring small compartment sections by installing the fire rated wall between bed rooms and another for ensuring the fire retardant or/and non-flammable performance of finishing materials. Also fire protection engineered technology was presented by two items; one for imposing cooling effects by sprinklers and another for providing automatic fire alarm notifying functions to fire stations. In order to improve the escape safety of these facilities in Korea, alternative revisions may presented by considering insufficient provisions in the architectural/fire law provisions by analyzing the provisions of Japanese and domestic laws in detail.