• Title/Summary/Keyword: Protection measure

Search Result 598, Processing Time 0.024 seconds

Statistical Study of Failure-Modes around the Pibanryeong Region, Boeun-Gun, Chungbuk (충북 보은군 피반령 부근 절취사면의 파괴양상에 대한 통계학적 연구)

  • Cheong, Sang-Won;Choi, Byoung-Ryol
    • The Journal of Engineering Geology
    • /
    • v.19 no.4
    • /
    • pp.517-528
    • /
    • 2009
  • Statistical analyses of cut-slope stability were performed over approximately 5.7 km section along the National road No. 25, which cross-cuts in NW-SE direction the Cheongwon and Boeun-Gun area, Chungbuk. A measure of slope-stability was established by using direct reinforcement and indirect protection methods in whole section. Orientations(dip/dip direction) of the slopes, foliations(bedding), cleavages and joints were measured in total of 30 slope sites. The results analyzed using stereographic projection indicate that major directions of the slopes come out predominantly in three directions: 1) $58^{\circ}/095^{\circ}$, 2) $60^{\circ}/296^{\circ}$ and 3) $59^{\circ}/212^{\circ}$. In analyses of dip direction and frequency of cut-slopes established by reinforcement and protection methods, slopes with dip direction of $80-120^{\circ}$ and $280-320^{\circ}$ mostly occur. However, slopes with dip direction of $0-80^{\circ}$(N and NW) and $120-160^{\circ}$(SE) are not distributed in the study area. Failure aspects were analyzed for three major directions of the slopes, respectively. The results of failure aspects analyzed indicate that slopes in the study area could generate various failures as the results of intersection and/or intersection combination among joints, foliations(bedding) and cleavages. However, possibility of failure in a slope of major direction No. 3 is statistically very low because of low frequency in total number of slopes with the direction and of formation of small scale-slopes geographically, although the slope might generate all aspects of failure-modes.

A Study on the Characteristics Assessment and Fabrication of Distribution Board according to KEMC Standards (KEMC 규정에 의한 분전반의 제작 및 특성 평가에 관한 연구)

  • Lee, Byung-Seol;Choi, Chung-Seog
    • Fire Science and Engineering
    • /
    • v.31 no.3
    • /
    • pp.63-72
    • /
    • 2017
  • This study fabricated a low-voltage 10 circuit distribution board based on the KEMC (Korea Electrical Manufacturers Cooperative) 2102-610 standard and performed a characteristics assessment of the developed 10 circuit distribution board to secure product stability. The developed 10 circuit distribution board is designed to have the characteristics of insulation materials, as well as resistance to corrosion ultraviolet radiation and mechanical impact. The developed distribution board is fabricated to have an appropriate protection class of enclosure, electric shock prevention and protection circuits, switchgear and its components, internal electrical circuits and connectors, external conduct terminal, insulation characteristics, temperature rise test, heat resistance, etc. The developed 10 circuit distribution board consists of a single phase circuit and 3-phase circuits. It is possible to measure in real time the leakage current generated from the load distribution line by installing a sensor module at the load side of each of the branched switchgears. In addition, it is possible to increase a circuit according to the use and purpose of the load and to also manage and check the load in real time. Temperature rise tests were performed on the developed 10 circuit distribution board at 18 places including the inlet connection, main circuit and distribution circuit bus bars and bus bar supports, etc. The highest temperature of $65.3^{\circ}C$ was measured at the R-Phase of the connection of the MCCB power supply for the branch circuit bus bar and a temperature rise of $61.6^{\circ}C$ was measured at the T-Phase of the load side. When applying thermal stress to an MCCB for 6 hours at $180^{\circ}C$ using a heat resistant experimental device, it was found that the actuator lever was transformed and moved in the tripped state.

Thermal Characteristics of Permeable Block Pavements for Landscape Construction (조경용 투수성 블록포장의 열특성)

  • Han, Seung-Ho;Ryu, Nam-Hyong;Yoon, Yong-Han;Kim, Won-Tae;Kang, Jin-Hyoung
    • Journal of Environmental Science International
    • /
    • v.17 no.5
    • /
    • pp.573-580
    • /
    • 2008
  • This study aims to measure and to analyze the characteristics of thermal environment of the various permeable pavement materials such as a break stone pavement (Green block cubic), soil protection pavement (Soil tector), soil cement pavement and ceramic brick pavement under the summer outdoor environment. The thermal environment characteristics measured in the study includes the changes of surface temperature during the day, and long and short wave radiation of each pavement surface. The experimental condition is based on the data on the hottest temperature (August 9, 2006, $37.1^{\circ}C$) of the year. The albedo was the highest on the break stone pavement(0.8) from 12:00 to 14:00. The albedo of the ceramic brick pavement, a soil tector pavement and soil cement pavement were 0.35, 0.29 and 0.27 from 12:00 to 14:00, respectively. The peak surface temperature and long wave radiation was the highest on the soil protection pavements($56.6^{\circ}C$/627 W/$m^2$). The peak surface temperatures and long wave radiation on the ceramic brick pavement, a stone brick pavement and soil cement pavement were $51.7^{\circ}C$/627 W/$m^2$, $48.8^{\circ}C$/607 W/$m^2$ and $45.9^{\circ}C$/582 W/$m^2$, respectively. The heat environment was better on the break stone pavement than on the other pavements. This is mainly due to the high albedo of the break stone pavement(0.8) while the albedo value of a ceramic brick pavement, a soil tactor pavement and soil cement pavement were 0.35. 0.29 and 0.27. Large heat capacity($2,629kJ/m^3{\cdot}K$) of the stone brick pavements also contributes to this difference. The heat environment was better on the soil cement pavement than the soil tector pavement. This is mainly due to the evaporation of the soil cement pavement while the active evaporation of the soil tactor pavement was not continued after two days from the rainfall event. To improve the thermal environments in the urban area, it is recommended to raise the albedo of the pavements by brightening the surface color of the pavement materials. Further studies on the pavement materials and the construction methods which can enhance the continuous evapotranspiration from the pavements surface are needed.

A Performance Evaluation of Diagnostic X-ray Unit Depends on the Hospitals Size (병원 규모별 진단용 X선 발생장치의 성능 평가)

  • Park, Ju-Hun;Im, In-Chul;Dong, Kyung-Rae;Kang, Se-Sik
    • Journal of Radiation Protection and Research
    • /
    • v.34 no.1
    • /
    • pp.31-36
    • /
    • 2009
  • The purpose of this study is to measure the tube voltage, the tube current/volume, exposure time and exposure dose of diagnostic X-ray unit in each doctor offices, hospitals and general hospitals for evaluating the performance of such device, to learn the method and technology of its measurement and to suggest its importance. Research subjects were total 30 X-ray units and divided into groups of 10 X-ray units each. The tube voltage, the tube current/volume, exposure time and exposure dose were measured using percentage average error, and then reproducibility of exposure dose was measured through calculating coefficient of variation. The results are like followings; The tube voltage correctness examination showed that incongruent devices among total 30 X-ray units were 5 devices (16.7%). The tube current correctness examination showed that incongruent X-ray units were 3 devices (10.0%). The tube current volume correctness examination showed that incongruent X-ray units were 4 devices (13.3%). Finally, according to exposure time correctness examination, incongruent X-ray units were 5 devices (16.7%) and according to reproducibility examination of exposure dose, incongruent X-ray units were 7 devices (23.3%). Above results showed serious problem in performance management based on management regulation of diagnostic X-ray unit; it means that regular checkout and safety management are required, and as doing so, patients will be able to receive good quality of medical service by the reduction of radiation exposure time, image quality administration, unnecessary retake and etc. Therefore, this study suggests that the performance of diagnostic X-ray units should be checked regularly.

Measurement of Growth Delay and the Oxygen Enhancement Ratio of Fast Neutron Beam Using Mouse Model System (마우스모델을 이용한 고속중성자선의 성장지연 및 산소증강비의 측정)

  • Eom, Keun-Yong;Park, Hye-Jin;Kwon, Eun-Kyung;Ye, Sung-Joon;Lee, Dong-Han;Wu, Hong-Gyun
    • Journal of Radiation Protection and Research
    • /
    • v.32 no.4
    • /
    • pp.178-183
    • /
    • 2007
  • Neutrons are high LET (linear energy transfer) radiation and cause more damage to the target cells than x-rays or gamma rays. The damage from neutrons is generally considered fatal to a cell and neutrons have a greater tendency to cause cell death through direct interaction on DNA. We performed experiments to measure growth delay ratio and oxygen enhancement ratio (OER) in mouse model system. We inoculated EMT-6 cells to the right hind leg of BALB-c mouse and X-rays and neutron beams were given when the average volume of tumors reached $200-300mm^3$. We irradiated 0, 11, 15.4 Gy of X-ray and 0, 5, 7 Gy of fast neutron beam at normoxic and hypoxic condition. The volume of tumors was measured 3 times per week. In x-ray experiment, growth delay ratio was 1.34 with 11 Gy and 1.33 with 15.4 Gy in normoxic condition compared to in hypoxic condition, respectively. In neutron experiment, growth delay ratio was 0.94 with 5 Gy and 0.98 with 7 Gy, respectively. The OER of neutron beam was 0.97. The neutron beam was more effective than X-ray in the control of hypoxic tumors.

Analysis of Magnitude and Behavior of Rockfall for Volcanic Rocks in Ulleung-Do (울릉도 화산암류의 낙석 규모 및 거동 분석)

  • Moon, Gi-Bong;You, Young-Min;Yun, Hyun-Seok;Suh, Young-Ho;Seo, Yong-Seok;Baek, Yong
    • The Journal of Engineering Geology
    • /
    • v.24 no.3
    • /
    • pp.373-381
    • /
    • 2014
  • It is difficult to predict the magnitude of a rockfall with respect to the shape, volume, and weight of the rock mass, as a rockfall exhibits erratic behavior that depends on the slope geometry, such as the height and dip of the slope. In this study, a field survey was conducted on the slopes of Ulleung-Do, South Korea, where rockfalls frequently occur along coastal roads, to classify the mode of rockfalls and estimate their magnitude. This study also analyzed the effects of rockfall behavior on roads by applying a simulation technique. Agglomerate and trachytic rocks distributed across the study area produce rockfalls in a differential weathering rockfall mode and a toppling rockfall mode. In terms of rockfall weight, trachytic rockfalls were 2-3 times heavier than agglomerate rockfalls. An analysis of rockfall behavior from the simulation indicates that the impact energy on the road exceeded the absorbing energy of a standard rockfall protection fence; however, the rockfall was secured when a ring-net was applied.

A Study on the Over-current Characteristics of IV Insulated Wire Sheath According to Accelerated Degradation (가속열화에 따른 IV절연전선 피복의 과전류 특성에 관한 연구)

  • Kim, Si-Kuk;Choi, Su-Gil
    • Fire Science and Engineering
    • /
    • v.32 no.2
    • /
    • pp.48-56
    • /
    • 2018
  • This paper reports the results of a study on the over-current characteristics of IV insulated wire sheath according to accelerated degradation. In order to examine the degradation of a IV insulated wire sheath through insulation, acceleration degradation experiments were performed using the Arrhenius equation of acceleration life test models; test samples with equivalent lives of 0, 10, 20, 30 and 40 years were prepared. Then allowed currents with over-current of 100%~500% were introduced to measure the times of first generation of smokes and carbonization in the wire sheath, and it was found that the times of first generation of smokes and carbonization in the wire sheath decreased as the equivalent life increased. In more detail, when 270% over-current is applied, the electrical fire risk of equivalent life of 40 years increased by approximately 3.2 times based on equivalent life of 0 years. Also, when the over-current was 255% and 260%, carbonization occurred only in the equivalent life of 40 years, and the fire risk according to the accelerated degradation was increased dramatically. In addition, FT-IR and SEM analyzes were used to confirm the characteristics and surface changes of IV insulated wire sheath according to the equivalent life.

A Critical Review on Complementary and Alternative Medicine/Pseudo-medicine/Quackery: Implication on Health Policy (유사의료/보완의료에 대한 보건의료정책학적 고찰)

  • Han, Dong-Woon;Hwang, Jung-Hye
    • The Korean Society of Law and Medicine
    • /
    • v.11 no.2
    • /
    • pp.113-145
    • /
    • 2010
  • Nowadays, it is surely the quack which stands as one of the most controversial, problematic. the quack has been a consistent target of contested public protection strategies in the past few centuries in many countries. Recently, complementary and alternative medicine (CAM) is increasingly utilized and accepted by patients and providers throughout the health care system in the world, most accounts attribute this growing acceptability to the shortcomings of conventional medicine, the appeal of CAM's core beliefs, and the growing body of research indicating that CAM actually works. However, the governments of western countries have called for measures to ensure that the public are protected from incompetent and dangerous practitioners. Common to these controversies has been a suggestion to ban, exclude or limit the medical practice of those deemed to be damaging rather than improving the health of individuals as a measure of public protection. This article describes the experiences of western counties' health care system which is moving in a more pluralistic direction. By examining the ways in which regulatory efforts in the countries have come to address what is invariably described as a growing interest in CAM, this study show how the problem of CAM/quackery today is increasingly located in an ethical field of practitioner competency, qualifications, conduct, responsibility and personal professional development, regardless of the form of therapy in question. Many countries developed a series of measures and strategies to contain the acceptance of CAM groups, such as insisting on scientific evidence of safety and efficacy, resisting integration of CAM with conventional medicine and opposing government support for research and education. In a sense, those countries' movements serve to protect not only patients, but the dominant position of medicine and its allied professions, and to maintain existing jurisdictional boundaries within the healthcare system. The popular support for CAM will require that health professional stakeholders continue to address the challenges this poses, and at the same time protect their position at healthcare system. To cope with the quack, professional body, public sector and health authorities should consider the safety of consumers of healthcare and responding to the demands of the community for CAM therapies as well as the claims of the established healthcare professions. Finally, some implications for future health care were suggested.

  • PDF

Induced Activity and Space Dose Distribution from Medical Linear Accelerator (의료용(醫療用) 선형가속기(線型加速器)에 의한 산난공간(散亂空間) 선량분포(線量分布)와 유도방사능(誘導放射能))

  • Chu, Sung-Sil;Park, Chang-Yun
    • Journal of Radiation Protection and Research
    • /
    • v.11 no.1
    • /
    • pp.51-56
    • /
    • 1986
  • It is important to measure and protect from the radiation space dose and induced activity at the high energy medical linear accelerator facilities. These are to consider the additional risk to patients undergoing treatment, machine operators and staff members. Measurements of the space dose distribution and induced radioactivity at the 18 MeV medical linear accelerator facility in the Yonsei Cancer Center. 1. Exposure space dose for 300 rads monitor doses of 18 MeV electron are measured as 50 mR at 1 meter from patients. 2. Exposure space dose for 300 rads monitor doses of 10 MV X-ray are detected as 350 mR at 1 meter from phantom. 3. Induced radioactivity by photonuclear reaction was measured as 0.65 mR/hr from collimater after 30 Gy(3,000 rads) irradiated. 4. Analyzing the decay curves and energy spectrum of induced radioactivity, detected a few materials to be activated by photoneutron reaction, $^{65}Cu({\gamma}{\cdot}n)\;^{64}Cu,\;^{186}W({\gamma}{\cdot}n)\;^{185}W,\;^{181}Ta({\gamma}{\cdot}n)\;^{180}Ta,\;^{199}Au({\gamma}{\cdot}n)\;^{198}Au$.

  • PDF

Air Density Correction of Ionization Chamber using $^{90}Sr$ Radioactive Check Device ($^{90}Sr$ 방사성 동위원소를 이용한 전리함의 대기 보정계수 측정)

  • Park, Sung-Y.;Kim, Woo-C.;Shin, Dong-O.;Ji, Young-H.;Kwon, Soo-I.;Lee, Kil-D.;Cho, Young-K.;Loh, John-J.
    • Journal of Radiation Protection and Research
    • /
    • v.23 no.4
    • /
    • pp.267-271
    • /
    • 1998
  • It is required to measure air density correction factor at the time of absorbed dose calibration or measurement. In general, thermometer and barometer are widely used for air density correction. However, this can be done using the radioactive check device with better accuracy. The measurements of air density correction were performed by using the radioactive check device, Unidos electrometer, and 0.6 cc Farmer-type ion chamber of PTW under the different environmental conditions. Above experiments were repeated with thermometer and barometer. By comparing the two methods, they were within the difference of 0.2 %. The overall uncertainty for the dose found in thermometer and barometer was 1.2 - 1.6 %, depending upon either one step or two, whereas the overall uncertainty for the radioactive check device was 1.02 %. This method may reduce the possible error which could occur when thermometer and barometer are not calibrated at regular basis.

  • PDF