• Title/Summary/Keyword: Protection Zones

Search Result 119, Processing Time 0.022 seconds

Comparative Analysis of Marine Accidents in Fishing Activity Protection Zones and Port and Navigation Zones to Improve Fishing Vessel Security (어선 통항 안전 확보를 위한 어업활동보호구역과 항만·항행구역의 해양사고 비교분석)

  • Hyundong Kim;Sangwon Park;Young-soo Park;Dae-won Kim;Gokhan Camliyurt
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.29 no.2
    • /
    • pp.118-126
    • /
    • 2023
  • In accordance with the increased demand for ocean use, the Marine Spatial Planning system was introduced to rationally allocate ocean space, under which fishing activity protection zones have been designated to protect fishery activities and promote fishery resource protection. However, fishing vessels that mainly sail in fishing activity protection zones are exposed to risk, such that they account for about 70% of marine accidents that occur in Korea, Proper risk management is thus required. This study aims to analyze marine accidents in fishing activities protection zones and port and navigation zones to secure the safety of fishing vessels passing within fishing activity protection zones. To this end, the traffic volume in marine use zones was investigated, and marine accidents were investigated by ship type, accident type, tonnage, accident cause, and loss of life. Analysis determined that most of the marine accidents per unit area of each type occurred in port and navigation zones, but overall most marine accidents occurred in fishing activity protection zones. In particular, it was found that traffic safety management was necessary because many human accidents occurred.

Status and Improvement Plans for Sidewalk Safety Facilities (Barrier) in Child Protection Area (어린이보호구역 내 보도안전시설(방호울타리) 설치 현황 및 개선 방안)

  • Bong-Chul Joo
    • Journal of Korean Society of Disaster and Security
    • /
    • v.16 no.4
    • /
    • pp.137-145
    • /
    • 2023
  • Accidents involving deaths of children and pedestrians continue to occur in child protection zones, also known as school zones. Over the three years from 2019 to 2021, 11 child deaths occurred in school zones in Korea. In December 2022, a fatal accident occurred among an elementary school student in a school zone near an elementary school in Gangnam-gu, Seoul. In April 2023, an accident occurred in which an elementary school student died in a school zone near Seo-gu Middle School in Daejeon and an elementary school in Yeongdo-gu, Busan. Until recently, child deaths continued to occur on sidewalks in child protection zones. It is time to closely review the status of safety facilities installed in school zones and related regulations. We investigated and analyzed the current status of safety facilities and related regulations installed on sidewalks in child protection zones in Korea, and identified matters necessary for institutional improvement regarding safety facilities for sidewalks in child protection zones.

Designation and Management of Water Source Protection Areas for Indirect Intakes

  • Choi, Ji-Yong;Hwang, Dae-Ho
    • Environmental Engineering Research
    • /
    • v.15 no.4
    • /
    • pp.231-237
    • /
    • 2010
  • With increased chemical and economic development activities in upstream areas, the amounts of pollutants released have increased, and as such, so has the need for positive management of water supply source areas. Although more than 90% of the water supply sources in Korea depend on direct intake from surface water, the interest in indirect intake, such as riverbank filtration water, has recently risen, with some local governments currently undertaking indirect intake. Even in cases of indirect intake, water supply source protection zones need to be assigned for the comprehensive control of pollutants. To establish water quality protection zones for indirect intake, the scope of the protection zones needed to reflect the hydrological features of the water-bearing deposits of each site. Water source protection areas were estimated and presented as the 1st (within a 100 m radius from an intake well) and 2nd (within a 2 km radius from an intake well) zones. The 1st zone was more sensitive; hence, the installation of various facilities should be prohibited, and the area should be regarded as off-limits. For the 2nd zone, appropriate management should prohibit and restrict activities already present in the water source protection zone.

Significance and Future Direction for Designation and Management of Landslide-Prone Zones (산사태 취약지역 지정·관리 제도의 의의와 향후 과제)

  • Kim, Suk Woo;Chun, Kun Woo;Kim, Kyoung Nam;Kim, Min Sik;Kim, Min Seok;Lee, Sang Ho;Seo, Jung Il
    • Journal of Forest and Environmental Science
    • /
    • v.29 no.3
    • /
    • pp.237-248
    • /
    • 2013
  • The legal basis for the systematic prevention and response to landslide hazards, and the rehabilitation of landslide-hit areas, was established through the amendment of the Forest Protection Act in August 2012. The most noticeable amendment to the Act is the inclusion of clauses associated with the designation and management of landslide-prone zones (including debris flow-prone zones). In this paper, we (1) introduce the clauses related to the designation and management of landslide-prone zones that were included in the amended Forest Protection Act, (2) examine their significance by reviewing the present status of related domestic laws and structural countermeasures such as sediment check dams for sediment-related disaster prevention, and (3) suggest the future directions of the procedure for the designation and cancellation of such zones, and their maintenance and institutional aspects. The establishment of an institutional device for the designation and management of landslide-prone zones has great significance in the aspect of (1) the establishment of a comprehensive management and prevention system for potential landslide-prone zones in forested areas where the hazard risk has been poorly recognized as compared with the flood risks in lowlands, and (2) the establishment of the basis for overcoming the limits of structural countermeasures according to limited budgets. To develop the designation and management system for landslide-prone zones, not only must present problems be addressed, but a cooperation system between the administration and local residents must also be established.

Improved Coordination Method for Back-up Protection Schemes Based on IEC 61850 (IEC 61850 기반 후비보호계전시스템 보호협조 개선방안)

  • Kim, Hyung-Kyu;Kang, Sang-Hee
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.1
    • /
    • pp.43-49
    • /
    • 2011
  • A distance relay scheme is commonly used for backup protection. This scheme, called a step distance protection, is comprised of 3 steps for graded zones having different operating time. As for the conventional step distance protection scheme, Zone 2 can exceed the ordinary coverage excessively in case of a transformer protection relay especially. In this case, there can be overlapped protection area from a backup protection relay and, therefore, malfunctions can occur when any fault occurs in the overlapped protection area. Distance relays and overcurrent relays are used for backup protection generally, and both relays have normally this problem, the maloperation, caused by a fault in the overlapped protection area. Corresponding to an IEEE standard, this problem can be solved with the modification of the operating time. On the other hand, in Korea, zones are modified to cope with this problem in some specific conditions. These two methods may not be obvious to handle this problem correctly because these methods, modifying the common rules, can cause another coordination problem. To overcome this problem clearly, this paper describes an improved backup protection coordination scheme using an IEC 61850-based distance relay for transformer backup protection. IEC 61850-based IED(Intelligent Electronic Device) and the network system based on the kernel 2.6 LINUX are realized to verify the proposed method. And laboratory tests to estimate the communication time show that the proposed coordination method is reliable enough for the improved backup protection scheme.

Development of Asynchronous Blocking Algorithm through Asynchronous Case Study of Steam Turbine Generator (스팀터빈 발전기 비동기 투입 사례연구를 통한 비동기 방지 알고리즘 개발)

  • Lee, Jong-Hweon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.10
    • /
    • pp.1542-1547
    • /
    • 2012
  • Asynchronous phenomenon occurs on the synchronous generators under power system when a generator's amplitude of electromagnetic force, phase angle, frequency and waveform etc become different from those of other synchronous generators which can follow instantly varying speed of turbine. Because the amplitude of electromagnetic force, phase frequency and waveform differ from those of other generators with which are to be put into parallel operation due to the change of excitation condition for load sharing and the sharing load change, if reactive current in the internal circuit circulates among generators, the efficiency varies and the stator winding of generators are overheated by resistance loss. When calculation method of protection settings and logic for protection of generator asynchronization will be recommended, a distance relay scheme is commonly used for backup protection. This scheme, called a step distance protection, is comprised of 3 steps for graded zones having different operating time. As for the conventional step distance protection scheme, zone 2 can exceed the ordinary coverage excessively in case of a transformer protection relay especially. In this case, there can be overlapped protection area from a backup protection relay and, therefore, malfunctions can occur when any fault occurs in the overlapped protection area. Distance relays and overcurrent relays are used for backup protection generally, and both relays have normally this problem, the maloperation, caused by a fault in the overlapped protection area. Corresponding to an IEEE standard, this problem can be solved with the modification of the operating time. On the other hand, in Korea, zones are modified to cope with this problem in some specific conditions. These two methods may not be obvious to handle this problem correctly because these methods, modifying the common rules, can cause another coordination problem. To overcome asynchronizing protection, this paper describes an improved backup protection coordination scheme using a new logic that will be suggested.

A Study on Protection of Generator Asynchronization by Impedance Relaying (임피던스 계전기를 이용한 발전기 비동기 투입 보호 연구)

  • Lee, Jong-Hweon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.11
    • /
    • pp.2000-2006
    • /
    • 2011
  • Asynchronous phenomenon occurs on the synchronous generators under power system when a generator's amplitude of electromagnetic force, phase angle, frequency and waveform etc become different from those of other synchronous generators which can follow instantly varying speed of turbine. Because the amplitude of electromagnetic force, phase frequency and waveform differ from those of other generators with which are to be put into parallel operation due to the change of excitation condition for load sharing and the sharing load change, if reactive current in the internal circuit circulates among generators, the efficiency varies and the stator winding of generators are overheated by resistance loss. Where calculation method of protection settings and Logic for Protection of Generator Asynchronization will be recommended, A distance relay scheme is commonly used for backup protection. This scheme, called a step distance protection, is comprised of 3 steps for graded zones having different operating time. As for the conventional step distance protection scheme, Zone 2 can exceed the ordinary coverage excessively in case of a transformer protection relay especially. In this case, there can be overlapped protection area from a backup protection relay and, therefore, malfunctions can occur when any fault occurs in the overlapped protection area. Distance relays and overcurrent relays are used for backup protection generally, and both relays have normally this problem, the maloperation, caused by a fault in the overlapped protection area. Corresponding to an IEEE standard, this problem can be solved with the modification of the operating time. On the other hand, in Korea, zones are modified to cope with this problem in some specific conditions. These two methods may not be obvious to handle this problem correctly because these methods, modifying the common rules, can cause another coordination problem. To overcome asynchronizing protection this paper describes an improved backup protection coordination scheme using a new Logic that will be suggested.

Ground Improvement under Ship Collision Protection of Myodo-Gangyang Suspension Bridge Concerning of Sedimental Condition in Gyangyang Bay (광양만 퇴적이력을 고려한 묘도-광양간 현수교 충돌방지공 하부 지반보강)

  • Chang, Yong-Chai;Yoon, Tae-Seob;Kim, Kyung-Taek
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.10a
    • /
    • pp.660-671
    • /
    • 2008
  • The suspension bridge between Myodo and Gwangyang is located in the main navigation channel to Gwangyang Harbor. So, there is need for the collision protection against large vessels. As ship collision protection, artificial island with concrete block quay wall is planned. The risk analysis and non-linear numerical analysis are introduced to consider the ship collision effects. In the Gwangyang bay area, there are some different sedimental conditions in clayey stratums. For a desirable design, we classify into four zones and 2 layers in each zone, and then determine suitable soil properties considering these zones. As a ground improvement under artificial island, DCM and SCP methods are Planned.

  • PDF

Vascular Plants Distributed in the Berchemia berchemiaefolia of Special Protection Zones of Songnisan National Park (속리산국립공원 특별보호구인 망개나무 자생지에 분포하는 관속식물상)

  • Oh, Hyun-Kyung;Kim, Young-Ha;Yun, Sang-Gi
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.20 no.3
    • /
    • pp.33-44
    • /
    • 2017
  • This study investigated in the vascular plants of special protection zones (the native land of Berchemia berchemiaefolia in Sadam-ri and Gallon valley) of Songnisan National Park and identified the whole vascular plants. The numbers of vascular plants were summarized as 273 taxa including 82 families, 182 genera, 236 species, 3 subspecies, 28 varieties and 6 forms. Woody plants were identified as 124 taxa (45.4%) and herbaceous plants as 149 taxa (54.6%). A total of 107 taxa were identified in the area of Sadam-ri, and 246 taxa were found in the Gallon valley. A total of 8 taxa of rare plants were identified, each of which was divided into 1 taxa of endangered (EN; Daphne pseudomezereum var. koreana), 3 taxa of vulnerable (VU; Paeonia japonica, Berchemia berchemiaefolia and Iris minutiaurea), 3 taxa of least concern (LC; Aristolochia contorta, Syringa patula var. kamibayshii and Goodyera schlechtendaliana) and 1 taxa of data deficient (DD; Alangium platanifolium). The Korean endemic plants were 9 taxa (Clematis trichotoma, Thalictrum actaefolium var. brevistylum, Aster koraiensis, Cirsium setidens, etc.). In the specific plants by floristic region were 34 taxa, a degree I were 17 taxa (Chloranthus japonicus, Celastrus stephanotifolius, etc.), 9 taxa of a degree II (Euonymus pauciflorus, Acer triflorum, etc.), 4 taxa of a degree III (Aconitum longecassidatum, Angelica gigas, etc.), 2 taxa of a degree IV (Ulmus macrocarpa and Daphne pseudomezereum var. koreana), 2 taxa of a degree V (Berchemia berchemiaefolia and Alangium platanifolium). The naturalized plants were 5 taxa including Fallopia dumetorum, Trifolium repens, Ailanthus altissima, Oenothera biennis, Erigeron annuus. Naturalization rate (NR) was 1.8% of all 273 taxa of vascular plants and the invasive alien plants were not found. The purpose of this study is to identify the flora that grows in the special protection zones of Songnisan National Park and provide the basic data for the management of the special protection zone in the future.

Identifying Other Effective Area-based Conservation Measures for Expanding National Protected Areas (국가 보호지역 확대를 위한 기타 효과적인 지역 기반 보전 수단(OECMs)의 발굴)

  • Hong, Jin-Pyo;Shim, Yun-Jin;Heo, Hag-Young
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.20 no.6
    • /
    • pp.93-105
    • /
    • 2017
  • This study aims to establish the integrated system of national protected areas by identifying OECMs which are not officially recognized as protected areas, but effectively and enduringly deliver the conservation of biodiversity and ecosystem service to expand them up to the level recommended by the international community. In order to identify them, candidates for OECMs were listed and it was developed a three-step systematic screening tool based on preconditions, essential characteristics, and sustainable means for conservation outcome of them. As a result of using the tool that considers domestic conditions, seven areas which included Development Restriction Zones, Urban Natural Park Areas, Fishery Resources Protection Zones, Riparian Zones, Natural Recreation Forest Zones, Water Source Protection Areas, and Buffer Zones for Korea National Arboretum were selected as OECMs. And the system of national protected areas was built by integrating them with national protected areas(NPA). Compared with the NPA, the system has been expanded by them and has reached to 17.88%, exceeding the target of 17% for terrestrial and inland water protections. It was proven that they were very effective in enlarging these protections. However, it failed to contribute to the target for marine protections. The expansion of marine protected areas requires different approaches, such as discovering new types of marine protected areas or linking them to biologically important marine areas all over the world.